Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am J Kidney Dis ; 60(6): 966-75, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22835900

RESUMEN

BACKGROUND: The benefits of biocompatible peritoneal dialysis (PD) fluids, particularly for residual renal function (RRF), are controversial. Moreover, the clinical effects of a PD regimen consisting of different biocompatible PD fluids have not been fully established. STUDY DESIGN: Prospective, randomized, controlled, open-label study. SETTING & PARTICIPANTS: Patients with end-stage kidney disease newly started on continuous ambulatory PD therapy (N = 150). INTERVENTION: A 12-month intervention with 3 biocompatible PD fluids (a neutral-pH, low glucose degradation product, 1.5% glucose solution; a solution with 1.1% amino acid; and a fluid with 7.5% icodextrin) or conventional PD fluid. OUTCOMES: The primary outcome was change in RRF and daily urine volume. Secondary outcomes were peritoneal transport and inflammation markers. MEASUREMENTS: RRF, daily urine volume, serum and dialysate cytokine levels. RESULTS: RRF(3.24 ± 1.98 vs 2.88 ± 2.43 mL/min/1.73 m(2); P = 0.9) and rate of decline in RRF (-0.76 ± 1.77 vs -0.91 ± 1.92 mL/min/1.73 m(2) per year; P = 0.6) did not differ between the biocompatible- and conventional-PD-fluid groups. However, patients using the biocompatible PD fluids had better preservation of daily urine volume (959 ± 515 vs 798 ± 615 mL/d in the conventional group, P = 0.02 by comparison of difference in overall change by repeated-measures analysis of variance). Their dialysate-plasma creatinine ratio at 4 hours was higher at 12 months (0.78 ± 0.13 vs 0.68 ± 0.12; P = 0.01 for comparison of the difference in overall change by repeated-measures analysis of variance). They also had significantly higher serum levels of adiponectin and overnight spent dialysate levels of cancer antigen 125, adiponectin, and interleukin 6 (IL-6). No differences between the 2 groups were observed for serum C-reactive protein and IL-6 levels. LIMITATIONS: Unblinded, relatively short follow-up; no formal sample-size calculations. CONCLUSIONS: Use of a combination of 3 biocompatible PD fluids for 12 months compared with conventional PD fluid did not affect RRF, but was associated with better preservation of daily urine volume. The biocompatible PD fluids also lead to changes in small-solute transport and an increase in dialysate cancer antigen 125, IL-6, adiponectin, and systemic adiponectin levels, but have no effect on systemic inflammatory response. The clinical significance of these changes, while of great interest, remains to be determined by further studies.


Asunto(s)
Materiales Biocompatibles/uso terapéutico , Soluciones para Diálisis/uso terapéutico , Mediadores de Inflamación/sangre , Fallo Renal Crónico/sangre , Fallo Renal Crónico/fisiopatología , Pruebas de Función Renal , Diálisis Peritoneal , Adulto , Anciano , Materiales Biocompatibles/farmacología , Transporte Biológico Activo/efectos de los fármacos , Transporte Biológico Activo/fisiología , Biomarcadores/sangre , Soluciones para Diálisis/farmacología , Femenino , Estudios de Seguimiento , Humanos , Mediadores de Inflamación/fisiología , Fallo Renal Crónico/terapia , Pruebas de Función Renal/métodos , Masculino , Persona de Mediana Edad , Diálisis Peritoneal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA