Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Radiol ; 29(7): 3617-3625, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30888484

RESUMEN

OBJECTIVES: The aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC). METHODS: This retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient. RESULTS: Line-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNRPankreas 32.5 vs. 15.7; SNRLesion 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement. CONCLUSION: MEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC. KEY POINTS: • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC.


Asunto(s)
Algoritmos , Carcinoma Ductal Pancreático/diagnóstico , Procesamiento de Imagen Asistido por Computador/métodos , Páncreas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Realidad Virtual , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
2.
Ann Vasc Surg ; 36: 290.e7-290.e10, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27395816

RESUMEN

The rupture of an extracranial vertebral artery aneurysm has only been rarely described in the literature and treatment options are therefore not standardized. Here we report the successful endovascular repair of a spontaneously ruptured extracranial left vertebral artery aneurysm using Onyx instillation. A 48-year-old woman was transferred to our clinic after having been intubated due to a massive hematoma of the left neck. A contrast-enhanced computed tomography (CT) showed a rupture of the left extracranial vertebral artery. Several issues complicated the therapeutic decision making in this rare case: first, the patient showed multiple aneurysms in CT angiography; therefore a connective tissue disease could not be excluded. Furthermore, as anamnestic work-up revealed that several episodes of postoperative bleeding and open surgery at this anatomic location are rarely performed, risks for postoperative complications were high. Therefore, the patient was hemodynamically stabilized and the ruptured aneurysm was treated in an endovascular approach with Onyx instillation and coil embolization. Complete exclusion of the aneurysm was achieved without periprocedural or neurological complications. Successful repair was confirmed by CT angiography on the first postoperative day as well as 12 months after the intervention. In conclusion, this case shows that endovascular Onyx embolization of ruptured vertebral aneurysms is a save and feasible method.


Asunto(s)
Aneurisma Roto/terapia , Dimetilsulfóxido/administración & dosificación , Embolización Terapéutica/métodos , Polivinilos/administración & dosificación , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/fisiopatología , Angiografía por Tomografía Computarizada , Femenino , Hemodinámica , Humanos , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/fisiopatología
3.
Cardiovasc Intervent Radiol ; 45(6): 744-751, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35391546

RESUMEN

PURPOSE: To compare bridging stent graft (BSG) implantation in downward oriented branches in branched endovascular aortic repair (bEVAR), using a commercially available steerable sheath from an exclusively femoral access (TFA) with traditional upper extremity access (UEA). METHODS: In a retrospective cohort study, 7 patients with 19 branches in the TFA cohort received BSG insertion using the Medtronic Heli FX steerable sheath from a femoral access, and 10 patients with 32 branches in the UEA cohort from a brachial approach. Technical success, total intervention time, fluoroscopy time, branch cannulation time, and complication rate were recorded. RESULTS: Technical success was 19/19 branches in the TFA and 31/32 in the UEA cohort. The mean branch cannulation time was considerably shorter in the TFA group (17 vs. 29 min, p = 0.003), and total intervention time tended to be shorter (169 vs. 217 min, p = 0.176). CONCLUSION: Using a commercially available steerable sheath allowed successful cannulation of all branches in this cohort and was associated with significantly shorter branch cannulation times. Potentially, this technique can lower the stroke and brachial puncture site complication risk as well as reduce total intervention time and radiation dose. LEVEL OF EVIDENCE: 2b, retrospective cohort study.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Stents , Resultado del Tratamiento , Extremidad Superior/irrigación sanguínea
4.
Cancers (Basel) ; 13(20)2021 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-34680232

RESUMEN

INTRODUCTION: Temporal bone paragangliomas are rare tumors with high vascularization and usually benign entity. A variety of modalities, including gross total resection, subtotal resection, conventional or stereotactic radiotherapy including gamma-knife, embolization, and wait-and-scan strategy can be considered. The aim of this study was to compare long-term outcomes of different primary treatment modalities in temporal bone paragangliomas. MATERIALS AND METHODS: Patients with temporal bone paragangliomas treated between 1976 and 2018 at a tertiary referral center were retrospectively analyzed in this study. Collected patient data of 42 years were analyzed and long-term results including interdisciplinary management were assessed. Patient outcomes were compared within the different therapy modalities according to tumor control rate and complications. Clinical characteristics, radiological imaging, tumor extent and location (according to Fisch classification), symptoms, and follow-up were evaluated and a descriptive analysis for each treatment modality was performed. Tumor recurrence or growth progression and respective cranial nerve function before and after therapy were described. RESULTS: A total of 59 patients were treated with a single or combined treatment modality and clinical follow-up was 7 (13) years (median, interquartile range). Of the included patients 45 (76%) were female and 14 (24%) male (ratio 3:1) with a patient age range from 18 to 83 years. Total resection was performed on 31 patients, while 14 patients underwent subtotal resection. Eleven patients were treated with conventional primary radiotherapy or gamma-knife radiosurgery. Pulsatile tinnitus (n = 17, 29%) and hearing impairment (n = 16, 27%) were the most common symptoms in our patient group. Permanent lower cranial nerve deficits were observed only in patients with large tumors (Fisch C and D, n = 14, 24%). Among the 45 patients who were treated surgically, 88% of patients with Fisch A and B paragangliomas had no recurrent disease, while no tumor growth was perceived in 83% of patients with Fisch C and D paragangliomas. CONCLUSION: In conclusion, we propose surgery as a treatment option for patients with small tumors, due to a high control rate and less cranial nerve deficits compared to larger tumors. Although patients with Fisch C and D temporal bone paraganglioma can be treated surgically, only subtotal resections are possible in many cases. Additionally, frequent occurrence of cranial nerve deficits in those patients and tumor growth progression in long-term follow-up examinations make a combination of the therapy modalities or a primary radiotherapy more suitable in larger tumors.

5.
PLoS One ; 15(2): e0228376, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32023294

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the impact of a 150kV spectral filtration chest imaging protocol (Sn150kVp) combined with advanced modeled iterative reconstruction (ADMIRE) on radiation dose and image quality in patients after lung-transplantation. METHODS: This study included 102 patients who had unenhanced chest-CT examinations available on both, a second-generation dual-source CT (DSCT) using standard protocol (100kVp, filtered-back-projection) and, on a third-generation DSCT using Sn150kVp protocol with ADMIRE. Signal-to-noise-ratio (SNR) was measured in 6 standardized regions. A 5-point Likert scale was used to evaluate subjective image quality. Radiation metrics were compared. RESULTS: The mean time interval between the two acquisitions was 1.1±0.7 years. Mean-volume-CT-dose-index, dose-length-product and effective dose were significantly lower for Sn150kVp protocol (2.1±0.5mGy;72.6±16.9mGy*cm;1.3±0.3mSv) compared to 100kVp protocol (6.2±1.8mGy;203.6±55.6mGy*cm;3.7±1.0mSv) (p<0.001), equaling a 65% dose reduction. All studies were considered of diagnostic quality. SNR measured in lung tissue, air inside trachea, vertebral body and air outside the body was significantly higher in 100kVp protocol compared to Sn150kVp protocol (12.5±2.7vs.9.6±1.5;17.4±3.6vs.11.8±1.8;0.7±0.3vs.0.4±0.2;25.2±6.9vs.14.9±3.3;p<0.001). SNR measured in muscle tissue was significantly higher in Sn150kVp protocol (3.2±0.9vs.2.6±1.0;p<0.001). For SNR measured in descending aorta there was a trend towards higher values for Sn150kVp protocol (2.8±0.6 vs. 2.7±0.9;p = 0.3). Overall SNR was significantly higher in 100kVp protocol (5.0±4.0vs.4.0±4.0;p<0.001). On subjective analysis both protocols achieved a median Likert rating of 1 (25th-75th-percentile:1-1;p = 0.122). Interobserver agreement was good (intraclass correlation coefficient = 0.73). CONCLUSIONS: Combined use of 150kVp tin-filtered chest CT protocol with ADMIRE allows for significant dose reduction while maintaining highly diagnostic image quality in the follow up after lung transplantation when compared to a standard chest CT protocol using filtered back projection.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Enfermedades Pulmonares/diagnóstico por imagen , Trasplante de Pulmón/métodos , Intensificación de Imagen Radiográfica/instrumentación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Femenino , Humanos , Enfermedades Pulmonares/cirugía , Masculino , Persona de Mediana Edad , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Estaño
6.
Trials ; 18(1): 594, 2017 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-29237489

RESUMEN

BACKGROUND: Self-expanding nitinol stents must be oversized at least by a minimal amount to ensure contact with the vessel wall and prevent migration. Once the stent is deployed it exerts a continuous force upon the vascular wall, termed chronic outward force (COF). Animal studies have found an increased neointimal hyperplasia in stents with high oversizing and thus high COF. Data about correlation between COF and neointimal hyperplasia in humans are currently lacking. The objective of the BIOFLEX-COF trial is to prospectively investigate differences in formation of intimal hyperplasia at 1 and 2 years after implantation of nitinol stents with high versus low COF in de novo femoropopliteal occlusive arterial lesions. METHODS: The BIOFLEX-COF trial is a prospective, quantitative, randomized study. Eighty subjects with symptomatic peripheral arterial lesions eligible for endovascular stent implantation will be enrolled and randomly assigned to either a high COF group (LifeStent Flexstar, Bard Peripheral Vascular Inc., Tempe, AZ, USA) or low COF group (Pulsar, Biotronik AG, Bülach, Switzerland) using an online randomization program to generate a random 1:1 group allocation (block randomization). After implantation and dilatation, COF at every 2 mm along the stent axis will be calculated from the actual stent diameter versus its nominal diameter. There will be two follow-up evaluations at 12 and 24 months. Primary endpoint is the amount of in-stent neointima at 1 year, assessed by contrast-enhanced CT angiography (CTA). In the control examinations, stent diameter and true lumen diameter will be measured on DICOM images every 2 mm along the stent axis to quantify the relative amount of in-stent restenosis. Secondary objectives are the amount of in-stent neointima at 2 years, device- and procedure-related adverse events and target lesion revascularization (TLR) rate. The scheduled time for recruitment is 2 years. Recruitment is expected to be complete in October 2017. DISCUSSION: This trial is the first to prospectively investigate the influence of COF on stent patency. If successful, the results will aid in a more precise selection of stent type and size in a given target vessel. The present study is challenging in that it compares two different self-expanding nitinol stents head-to-head against each other. To optimize the power of this study, traditional binary outcome parameters such as TLR and restenosis at Doppler ultrasound were dropped as primary endpoints. Instead, the amount of neointima inside the stent accessed by CTA was selected as (continuous) outcome parameter. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT03097679 . Date of registration: 14 March 2017 (retrospectively registered).


Asunto(s)
Aleaciones , Procedimientos Endovasculares/instrumentación , Arteria Femoral , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Stents Metálicos Autoexpandibles , Austria , Protocolos Clínicos , Angiografía por Tomografía Computarizada , Constricción Patológica , Procedimientos Endovasculares/efectos adversos , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Neointima , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Presión , Estudios Prospectivos , Diseño de Prótesis , Recurrencia , Proyectos de Investigación , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA