Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Lab Anal ; 36(2): e24238, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35034374

RESUMEN

OBJECTIVES: Even today, tuberculosis (TB) remains a leading public health problem; yet, the current diagnostic methods still have a few shortcomings. Lipoarabinomannan (LAM) provides an opportunity for TB diagnosis, and urine LAM detection seems to have a promising and widely applicable prospect. DESIGN OR METHODS: Four databases were systematically searched for eligible studies, and the quality of the studies was evaluated using the quality assessment of diagnostic accuracy studies-2 (QUADAS-2). Graphs and tables were created to show sensitivity, specificity, likelihood ratios, diagnostic odds ratio (DOR), the area under the curve (AUC), and so on. RESULTS: Based on the included 67 studies, the pooled sensitivity of urine LAM was 48% and specificity was 89%. In the subgroup analyses, the FujiLAM test had higher sensitivity (69%) and specificity (92%). Furthermore, among patients infected with human immunodeficiency virus (HIV), 50% of TB patients were diagnosed using a urine LAM test. Besides, the CD4+ cell count was inversely proportional to the sensitivity. CONCLUSIONS: Urine LAM is a promising diagnostic test for TB, particularly using the FujiLAM in HIV-infected adults whose CD4+ cell count is ≤100 per µl. Besides, the urine LAM test shows various sensitivities and specificities in different subgroups in terms of age, HIV infection status, CD4+ cell count, and testing method.


Asunto(s)
Lipopolisacáridos/orina , Tuberculosis/diagnóstico , Adulto , Recuento de Linfocito CD4 , Niño , Infecciones por VIH/complicaciones , Humanos , Mycobacterium tuberculosis , Sensibilidad y Especificidad , Tuberculosis/complicaciones , Tuberculosis/orina
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 30(3): 184-7, 223, 2006 May.
Artículo en Zh | MEDLINE | ID: mdl-16929775

RESUMEN

The portable gastrointestinal wireless endoscope image receiver is developed and based on TMS320C6211 DSP. It can receive and demodulate the modulated signal which is transmitted from the camera-capsule, and then output the video signal. The synchronizing signals offered by SAA7114H are made best of and are used to design the time logic circuit. The fitful video signal can be collected under the control of the time logic circuit. The circuit can automatically get rid of useless blank data and only collect effective and good-quality video signals, and storage them in CF card. In addition, the image signal can be processed and compressed by DSP, and thus the data storage space and the data- analyzing time can be saved.


Asunto(s)
Endoscopía Capsular/métodos , Endoscopios Gastrointestinales , Interpretación de Imagen Asistida por Computador/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Endoscopios en Cápsulas , Sistemas de Computación , Diseño de Equipo , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA