Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Muscle Nerve ; 70(2): 210-216, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38828855

RESUMEN

INTRODUCTION/AIMS: The current diagnosis of ulnar neuropathy at the elbow (UNE) relies mainly on the clinical presentation and nerve electrodiagnostic (EDX) testing, which can be uncomfortable and yield false negatives. The aim of this study was to investigate the diagnostic value of conventional ultrasound, shear wave elastography (SWE), and superb microvascular imaging (SMI) in diagnosing UNE. METHODS: We enrolled 40 patients (48 elbows) with UNE and 48 healthy volunteers (48 elbows). The patients were categorized as having mild, moderate or severe UNE based on the findings of EDX testing. The cross-sectional area (CSA) was measured using conventional ultrasound. Ulnar nerve (UN) shear wave velocity (SWV) and SMI were performed in a longitudinal plane. RESULTS: Based on the EDX findings, UNE severity was graded as mild in 4, moderate in 10, and severe in 34. The patient group showed increased ulnar nerve CSA and stiffness at the site of maximal enlargement (CSA mean at the site of max enlargement [CSAmax] and SWV mean at the site of max enlargement [SWVmax]), ulnar nerve CSA ratio, and stiffness ratio (elbow-to-upper arm), compared with the control group (p < .001). Furthermore, the severe UNE group showed higher ulnar nerve CSAmax and SWVmax compared with the mild and moderate UNE groups (p < .001). The cutoff values for diagnosis of UNE were 9.5 mm2 for CSAmax, 3.06 m/s for SWVmax, 2.00 for CSA ratio, 1.36 for stiffness ratio, and grade 1 for SMI. DISCUSSION: Our findings suggest that SWE and SMI are valuable diagnostic tools for the diagnosis and assessment of severity of UNE.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Codo , Nervio Cubital , Neuropatías Cubitales , Ultrasonografía , Humanos , Masculino , Femenino , Persona de Mediana Edad , Adulto , Diagnóstico por Imagen de Elasticidad/métodos , Neuropatías Cubitales/diagnóstico por imagen , Neuropatías Cubitales/fisiopatología , Codo/diagnóstico por imagen , Ultrasonografía/métodos , Anciano , Nervio Cubital/diagnóstico por imagen , Nervio Cubital/fisiopatología , Microvasos/diagnóstico por imagen , Electrodiagnóstico/métodos
2.
Clin Hemorheol Microcirc ; 84(4): 399-411, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37334584

RESUMEN

OBJECTIVE: This study aims to analyze the performance of endorectal ultrasound (ERUS) combined with shear wave elastography (SWE) for rectal tumor staging. METHODS: Forty patients with rectal tumors who had surgery were enrolled. They underwent ERUS and SWE examinations before surgery. Pathological results were used as the gold standard for tumor staging. The stiffness values of the rectal tumor, peritumoral fat, distal normal intestinal wall, and distal perirectal fat were analyzed. The diagnostic accuracy of ERUS stage, tumor SWE stage, ERUS combined with tumor SWE stage, and ERUS combined with peritumoral fat SWE stage were compared and evaluated by receiver operating characteristic (ROC) curve to select the best staging index. RESULTS: From T1 to T3 stage, the maximum elasticity (Emax) of the rectal tumor increased gradually (p < 0.05). The cut-off values of adenoma/T1 and T2, T2 and T3 tumors were 36.75 and 85.15kPa, respectively. The diagnostic coincidence rate of tumor SWE stage was higher than that of ERUS stage. Overall diagnostic accuracy of ERUS combined with peritumoral fat SWE Emax restaging was significantly higher than that of ERUS. CONCLUSIONS: ERUS combined with peritumoral fat SWE Emax for tumor restaging can effectively distinguish between stage T2 and T3 rectal tumors, which provides an effective imaging basis for clinical decisions.


Asunto(s)
Adenoma , Diagnóstico por Imagen de Elasticidad , Neoplasias del Recto , Humanos , Diagnóstico por Imagen de Elasticidad/métodos , Ultrasonografía , Neoplasias del Recto/diagnóstico por imagen , Neoplasias del Recto/patología , Neoplasias del Recto/cirugía , Estadificación de Neoplasias , Adenoma/patología
3.
Front Neurol ; 13: 1079737, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36588903

RESUMEN

Introduction: Carpal tunnel syndrome (CTS) is a common compression neuropathy of the median nerve in the wrist. Early diagnosis of CTS is essential for selecting treatment options and assessing prognosis. The current diagnosis of CTS is based on the patient's clinical symptoms, signs, and an electromyography (EMG) test. However, they have some limitations. Recently, ultrasound has been adopted as an adjunct diagnostic tool for electromyography (EMG). Ultrasound is a non-invasive and cost-effective technique. It provides a dynamic display of morphological changes in the median nerve and an assessment of CTS etiology such as tenosynovitis, mass compression, and tendon disease. This study aimed to investigate the value of conventional ultrasound and real-time shear wave elastography (SWE) in evaluation of median neuropathy in patients with carpal tunnel syndrome (CTS) before and after surgery. Methods: First, the Boston Carpal Tunnel Questionnaire (BCTQ) was administered to patients with CTS. All subjects were measured at three levels: the distal 1/3 of the forearm, the carpal tunnel inlet, and the distal carpal tunnel using conventional ultrasound and SWE. Median nerve parameters were examined in patients with CTS 1 week after surgery. Results: The cross-sectional area (CSA) and stiffness of the median nerve at the carpal tunnel inlet and distal carpal tunnel were significantly higher in patients with CTS than in healthy controls (p < 0.001). The CSA and stiffness of the median nerve at the carpal tunnel inlet were statistically significantly significantly between pre- and postoperative patients with CTS (p < 0.001). The CSA and stiffness of the nerve in patients with CTS had a positive correlation with electrophysiology severity. Conclusions and discussion: Conventional ultrasound and elastography are valuable in the diagnosis of CTS and are useful in the clinical assessment of patient's nerve recovery after operation.

4.
Eur J Radiol ; 126: 108965, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32268245

RESUMEN

PURPOSE: To explore the application value of conventional ultrasound and real-time shear wave elastography (SWE) to the tibial nerve (TN) and the common peroneal nerve (CPN) in diabetic peripheral neuropathy (DPN). MATERIALS AND METHODS: Thirty-three healthy volunteers, 33 diabetic patients without DPN, and 30 diabetic patients with DPN were enrolled in this study. The anteroposterior diameter (APD), the cross-sectional area (CSA), and the perimeter of the TN and the CPN were measured by conventional ultrasound, and the stiffness of the nerves was measured by SWE. RESULTS: The conventional ultrasound parameters and stiffness of the TN in patients with DPN were significantly larger than those of the other two groups (P < 0.01). The conventional ultrasound parameters of the CPN were significantly higher in patients with DPN than in the other two groups (P < 0.01).The patients with DPN demonstrated a greater stiffness of the CPN compared to the control group (P < 0.05). The comparison of all parameters for the left and right TNs and CPNs among the three groups showed no significant difference. The area under the curve (AUC) of TN stiffness for the diagnosis of DPN was significantly greater than that of conventional ultrasound parameters. CONCLUSION: The conventional ultrasound parameters and the stiffness of the TN and the CPN were significantly higher in patients with DPN. The stiffness of the TN could better diagnose DPN than conventional ultrasound parameters. In short, conventional ultrasound and SWE of nerves are of good application value in the diagnosis of DPN.


Asunto(s)
Diabetes Mellitus Tipo 2/fisiopatología , Neuropatías Diabéticas/diagnóstico por imagen , Neuropatías Diabéticas/fisiopatología , Ultrasonografía/métodos , Área Bajo la Curva , Diabetes Mellitus Tipo 2/complicaciones , Neuropatías Diabéticas/etiología , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neuropatías Peroneas/diagnóstico por imagen , Neuropatías Peroneas/etiología , Neuropatías Peroneas/fisiopatología , Estudios Prospectivos , Nervio Tibial/diagnóstico por imagen , Nervio Tibial/fisiopatología
5.
Eur J Med Chem ; 157: 50-61, 2018 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-30075402

RESUMEN

Novel bioactive heterocycles containing a 3,4,5-trimethoxyphenyl fragment as antiproliferative agents by targeting tubulin were synthesized and their preliminary structure activity relationships (SARs) were explored. Among all these chemical agents, 2-(Benzo[d]oxazol-2-ylthio)-N-(4-methoxybenzyl)-N-(3,4,5-trimethoxyphenyl)acetamide (4d) exhibited the potent antiproliferative activity against MGC-803 cells with an IC50 value of 0.45 µM by induction of G2/M pahse arrest and cell apoptosis. In addition, 4d could change the membrane potential (ΔΨ) of the mitochondria against MGC-803 cells. Importantly, 4d acted as a novel tubulin polymerization inhibitor binding to colchicine site with an IC50 value of 3.35 µM.


Asunto(s)
Antineoplásicos/farmacología , Compuestos Heterocíclicos/farmacología , Microtúbulos/efectos de los fármacos , Antineoplásicos/síntesis química , Antineoplásicos/química , Apoptosis/efectos de los fármacos , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Compuestos Heterocíclicos/síntesis química , Compuestos Heterocíclicos/química , Humanos , Microtúbulos/metabolismo , Modelos Moleculares , Estructura Molecular , Polimerizacion/efectos de los fármacos , Relación Estructura-Actividad , Tubulina (Proteína)/efectos de los fármacos , Tubulina (Proteína)/metabolismo
6.
Ultrason Sonochem ; 17(1): 58-60, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19501010

RESUMEN

The allylation reactions of aromatic aldehydes and ketones were carried out in 31-86% yield using SnCl(2)-H(2)O system under ultrasound irradiation at r.t. for 5h. The reactions in the same system gave homoallyl alcohols in 21-84% yield with stirring at r.t. for 24h. Compared with traditional stirring methods, ultrasonic irradiation is more convenient and efficient.


Asunto(s)
Aldehídos/química , Hidrocarburos Aromáticos/química , Hidrocarburos Aromáticos/efectos de la radiación , Cetonas/química , Sonicación/métodos , Compuestos de Estaño/química , Compuestos de Estaño/efectos de la radiación , Agua/química , Aldehídos/efectos de la radiación , Cetonas/efectos de la radiación , Microfluídica/métodos , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA