Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Am J Orthod Dentofacial Orthop ; 162(1): 93-102.e1, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35772876

RESUMEN

INTRODUCTION: In this study, we aimed to evaluate and compare the bracket positioning accuracy of the indirect bonding (IDB) transfer tray fabricated in-clinic using the tray printing (TP) and marker-model printing methods (MP). METHODS: The TP group was further divided into 2 groups (single-tray printing [STP] and multiple-tray printing [MTP]) depending on the presence of a tray split created using the 3-dimensional (3D) software. Five duplicated plaster models were used for each of the 3 experimental groups, and a total of 180 artificial teeth, except the second molar, were evaluated in the experiment. The dental model was scanned using a model scanner (E3; 3Shape Dental Systems, Copenhagen, Denmark). Virtual brackets were placed on facial axis points, and the IDB trays were designed and fabricated using a 3D printer (VIDA; EnvisionTEC, Mich). The accuracy of bracket positioning was evaluated by comparing the planned bracket positions and the actual bracket positions using 3D analysis on inspection software. The main effects and first-order interaction effects were analyzed together by analysis for the analysis of variance. RESULTS: The mean distance and height errors were significantly lower in the STP group than those in the MP and MTP groups (P <0.05). The mean distance error was 0.06 mm in the STP group and 0.09 mm in the MP and MTP groups. The mean height error was 0.10 mm in the STP group and 0.15 mm and 0.18 mm in MP and MTP groups, respectively. However, no significant differences were observed in the angular errors among the 3 groups. CONCLUSIONS: The in-office-fabricated IDB system with computer-aided design and 3D printer is clinically applicable after considering the linear and angular errors. We recommend IDB trays fabricated using the STP method owing to the lower frequency of bracket positioning errors and ease of fabrication.


Asunto(s)
Recubrimiento Dental Adhesivo , Soportes Ortodóncicos , Diseño Asistido por Computadora , Recubrimiento Dental Adhesivo/métodos , Humanos , Modelos Dentales , Impresión Tridimensional
2.
Eur J Orthod ; 36(5): 557-62, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24355870

RESUMEN

OBJECTIVES: This study compared the stability of tapered miniscrews with cylindrical miniscrews. MATERIALS/METHODS: One hundred and five tapered and 122 cylindrical self-drilling miniscrews were placed into the maxillary and mandibular buccal alveolar areas of 132 patients (43 males and 89 females). The insertion torque and removal torque were measured and Periotest values (PTVs) were recorded at implantation. RESULTS: The success rates of the tapered and cylindrical miniscrews examined were similar. In the maxilla, the insertion torque of the tapered miniscrews (8.3 Ncm) was significantly higher than that of the cylindrical miniscrews (6.3 Ncm) (P < 0.05). The PTVs of the tapered miniscrews were statistically significantly lower in the maxilla (P < 0.05). The removal torque values showed no significant difference between the tapered and cylindrical miniscrews in the upper and lower buccal areas (P > 0.05). CONCLUSIONS: Tapered miniscrews had higher initial stability when compared to cylindrical miniscrews, whereas the clinical success rates and removal torques were similar between the two designs. The long-term stability is not directly affected by the miniscrew design.


Asunto(s)
Tornillos Óseos , Métodos de Anclaje en Ortodoncia/instrumentación , Diseño de Aparato Ortodóncico , Adulto , Femenino , Humanos , Masculino , Mandíbula/cirugía , Maxilar/cirugía , Oseointegración/fisiología , Torque
3.
J Periodontol ; 86(9): 1078-86, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25957054

RESUMEN

BACKGROUND: This study evaluates the effect of recombinant human bone morphogenetic protein-2 (rhBMP-2) on the quality and quantity of regenerated bone when injected into distracted alveolar bone. METHODS: Sixteen adult beagle dogs were assigned to either the control or rhBMP-2 group. After distraction was completed, an rhBMP-2 dose of 330 µg in 0.33 mL was injected slowly into the distracted alveolar crest of the mesial, middle, and distal parts of the alveolar bone in the experimental group. Histologic and microcomputed tomography analyses of regenerated bone were done after 2 and 6 weeks of consolidation. RESULTS: After 6 weeks of consolidation, the vertical defect height in the middle of the regenerated bone was significantly lower in the rhBMP-2 group (2.2 mm) than in the control group (3.4 mm) (P <0.05). Additionally, the width of the regenerated bone was significantly greater in the rhBMP-2 group (4.3 mm) than in the control group (2.8 mm) (P <0.05). The bone density and volume of regenerated bone in the rhBMP-2 group were greater than in the control group after 6 weeks of consolidation (P <0.001). CONCLUSION: Injection of rhBMP-2 into regenerated bone after a distraction osteogenesis procedure significantly increased bone volume in the dentoalveolar distraction site and improved both the width and height of the alveolar ridge and increased the bone density.


Asunto(s)
Proceso Alveolar/efectos de los fármacos , Proteína Morfogenética Ósea 2/uso terapéutico , Maxilar/cirugía , Osteogénesis por Distracción/métodos , Osteogénesis/efectos de los fármacos , Factor de Crecimiento Transformador beta/uso terapéutico , Proceso Alveolar/patología , Proceso Alveolar/cirugía , Animales , Densidad Ósea/efectos de los fármacos , Proteína Morfogenética Ósea 2/administración & dosificación , Regeneración Ósea/efectos de los fármacos , Hueso Esponjoso/efectos de los fármacos , Hueso Esponjoso/patología , Hueso Esponjoso/cirugía , Perros , Humanos , Inyecciones , Maxilar/efectos de los fármacos , Maxilar/patología , Tamaño de los Órganos , Proteínas Recombinantes/administración & dosificación , Proteínas Recombinantes/uso terapéutico , Factores de Tiempo , Factor de Crecimiento Transformador beta/administración & dosificación , Microtomografía por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA