RESUMEN
PURPOSE: The objective of this study was to verify the influence of test environment on the flexural strength of dental porcelains with distinct microstructures. MATERIAL AND METHODS: Disk-shaped specimens from three dental porcelains with distinct leucite content (VM: zero; CE: 12; NS: 22 vol%) were manufactured and tested for biaxial flexural strength in air and immersed in artificial saliva. The results were analyzed by means of two-way ANOVA and Tukey's test (α= 0.05). RESULTS: The flexural strength (MPa) obtained for ambient air and artificial saliva environments, respectively, were: 110.0 ± 16.0 and 81.5 ± 10.8 for VM; 51.9 ± 4.0 and 42.0 ± 4.7 for CE; 72.0 ± 11.5 and 63.6 ± 5.8 for NS. A numerical decrease in the mean flexural strength was observed for all groups when specimens were tested under artificial saliva; however, the difference was only statistically significant for VM. CONCLUSIONS: The results indicate that the effect of water immersion on the flexural strength of dental porcelains varies according to their leucite content, as only the material without leucite in its microstructure (VM) showed significant strength degradation when tested under water.
Asunto(s)
Porcelana Dental/química , Análisis del Estrés Dental , Ensayo de Materiales/métodos , Silicatos de Aluminio , Cristalización , Módulo de Elasticidad , Docilidad , Saliva Artificial , Resistencia a la Tracción , Vibración , AguaRESUMEN
OBJECTIVES: To evaluate the effect of pH of storage medium on slow crack growth (SCG) parameters of dental porcelains. METHODS: Two porcelains were selected: with (UD) and without (VM7) leucite particles, in order to assess if the microstructure would affect the response of the material to the pH variation. Disc specimens were produced following manufacturers' instructions. Specimens were stored in artificial saliva in pHs 3.5, 7.0 or 10.0 for 10 days and after that the fatigue parameters (n: SCG susceptibility coefficient and sigma(0): scaling parameter) were obtained by the dynamic fatigue test using the same pH of storage. Microstructural analysis of the materials was also performed. RESULTS: For VM7, the values of n obtained in the different pHs were similar and varied from 29.9 to 31.2. The sigma(0) value obtained in pH 7.0 for VM7 was higher than that obtained in the other pHs, which were similar. For porcelain UD, n values obtained in pHs 7.0 and 10.0 were similar (40.8 and 39.6, respectively), and higher than that obtained in pH 3.5 (26.5). With respect to sigma(0), the value obtained for porcelain UD in pH 10.0 was lower than those obtained in pHs 3.5 and 7.0, which were similar. SIGNIFICANCE: The effect of pH on the stress corrosion susceptibility (n) depended on the porcelain studied. While the n value of VM7 was not affected by the pH, UD presented lower n value in acid pH. For both porcelains, storage in acid or basic pH resulted in strength degradation.
Asunto(s)
Porcelana Dental/química , Óxido de Aluminio/química , Silicatos de Aluminio/química , Análisis del Estrés Dental , Dureza , Humanos , Ácido Clorhídrico/química , Concentración de Iones de Hidrógeno , Procesamiento de Imagen Asistido por Computador , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Tamaño de la Partícula , Saliva Artificial/química , Hidróxido de Sodio/química , Espectrometría por Rayos X , Estrés Mecánico , Propiedades de Superficie , Difracción de Rayos XRESUMEN
OBJECTIVES: To determine the stress corrosion susceptibility coefficient, n, of seven dental porcelains (A: Ceramco I; B: Ceramco-II; C: Ceramco-III; D: d.Sign; E: Cerabien; F: Vitadur-Alpha; and G: Ultropaline) after aging in air or artificial saliva, and correlate results with leucite content (LC). METHODS: Bars were fired according to manufacturers' instructions and polished before induction of cracks by a Vickers indenter (19.6N, 20s). Four specimens were stored in air/room temperature, and three in saliva/37 degrees C. Five indentations were made per specimen and crack lengths measured at the following times: approximately 0; 1; 3; 10; 30; 100; 300; 1000 and 3000 h. The stress corrosion coefficient n was calculated by linear regression analysis after plotting crack length as a function of time, considering that the slope of the curve was [2/(3n+2)]. Microstructural analysis was performed to determine LC. RESULTS: LC of the porcelains were 22% (A and B); 6% (C); 15% (D); 0% (E and F); and 13% (G). Except for porcelains A and D, all materials showed a decrease in their n values when stored in artificial saliva. However, the decrease was more pronounced for porcelains B, F, and G. Ranking of materials varied according to storage media (in air, porcelain G showed higher n compared to A, while in saliva both showed similar coefficients). No correlation was found between n values and LC in air or saliva. SIGNIFICANCE: Storage media influenced the n value obtained for most of the materials. LC did not affect resistance to slow crack growth regardless of the test environment.
Asunto(s)
Silicatos de Aluminio/química , Porcelana Dental/química , Aire , Algoritmos , Silicatos de Aluminio/análisis , Apatitas/análisis , Apatitas/química , Porcelana Dental/análisis , Vidrio/análisis , Vidrio/química , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Saliva Artificial/química , Estrés Mecánico , Propiedades de Superficie , Temperatura , Factores de TiempoRESUMEN
OBJECTIVE: To evaluate the effect of two aging methods (mechanical cycling and autoclave) on the mechanical behavior of veneer and framework ceramic specimens with different configurations (monolithic, two and three-layers). METHODS: Three ceramics used as framework for fixed dental prostheses (YZ-Vita In-Ceram YZ; IZ-Vita In-Ceram Zirconia; AL-Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs: monolithic, two layers (porcelain-framework) and three layers (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. Three different experimental conditions were evaluated (n=10): control; mechanical cycling (2Hz, 37°C artificial saliva); and autoclave aging (134°C, 2 bars, 5h). Bi-layered specimens were tested in both conditions: with porcelain or framework ceramic under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy. Results were statistically analyzed using Kruskal-Wallis and Student-Newman-Keuls tests. RESULTS: Only for AL group, mechanical cycling and autoclave aging significantly decreased the flexural strength values in comparison to the control (p<0.01). YZ, AL, VM7 and VM9 monolithic groups showed no strength degradation. For multi-layered specimens, when the porcelain layer was tested in tension (bi and tri-layers), the aging methods evaluated also had no effect on strength (p≥0.05). Total and partial failure modes were identified. SIGNIFICANCE: Mechanical cycling and autoclave aging protocols had no effect on the flexural strength values and failure behavior of YZ and IZ ceramic structures. Yet, AL monolithic structures showed a significant decrease in flexural strength with any of the aging methods.
Asunto(s)
Óxido de Aluminio , Cerámica , Porcelana Dental , Coronas con Frente Estético , Análisis del Estrés Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Estrés Mecánico , Propiedades de Superficie , CirconioRESUMEN
OBJECTIVES: To determine the correlation between fracture toughness and leucite content in dental porcelains. The mechanisms by which leucite influences the fracture toughness of dental porcelains were also investigated. METHODS: Six porcelains were tested: A (Ceramco I/Dentsply), B (Ceramco II/Dentsitply), C (Finesse/Dentsply), D (d.Sign/Ivoclar), Cb (Cerabien/Noritake) and V (Vitadur Alpha/Vita). Bar-shaped specimens were produced, and their fracture toughness was determined by means of the single-edge precracked beam (SEPB) method. The test consisted of fracturing the specimen after a precrack was generated by a bridge-anvil device. KIc was calculated based on fracture force and size of the precrack. Microstructural analysis and determination of the leucite volume fraction were performed on polished specimens etched with 2% HF for 15s by means of scanning electron microscopy. Fractographic analysis was performed on fracture surfaces. RESULTS: Porcelains A and B presented the highest leucite contents (22%) and similar KIc values (1.23 and 1.22 MPa m1/2, respectively), significantly higher than the other materials. Porcelains C and D presented similar K(Ic) values (0.81 and 0.93 MPa m1/2, respectively), but different leucite contents (6 and 15%, respectively). Porcelain D presented higher KIc compared to porcelains Cb and V (0.71 and 0.75 MPa m1/2, respectively), which presented similar values and the lowest leucite contents (0%). Fractographic analysis showed that porcelains with higher leucite content presented higher incidence of crack deflection. CONCLUSIONS: For the materials evaluated in this study, the leucite content was directly related to KIc. The main toughening mechanism observed was crack deflection around leucite particles and clusters.
Asunto(s)
Silicatos de Aluminio/química , Porcelana Dental/química , Dureza , Ensayo de Materiales/métodos , Estrés MecánicoRESUMEN
OBJECTIVE: Ceramic composites are promising materials for dental restorations. However, it is difficult to prepare highly translucent composites due to the light scattering that occurs in multiphase ceramics. The objective of this work was to verify the effectiveness of a systematic approach in designing specific glass compositions with target properties in order to prepare glass infiltrated ceramic composites with high translucency. METHODS: First it was necessary to calculate from literature data the viscosity of glass at the infiltration temperature using the SciGlass software. Then, a glass composition was designed for targeted viscosity and refractive index. The glass of the system SiO2-B2O3-Al2O3-La2O3-TiO2 prepared by melting the oxide raw materials was spontaneously infiltrated into porous alumina preforms at 1200°C. The optical properties were evaluated using a refractometer and a spectrophotometer. The absorption and scattering coefficients were calculated using the Kubelka-Munk model. RESULTS: The light transmittance of prepared composite was significantly higher than a commercial ceramic-glass composite, due to the matching of glass and preform refractive indexes which decreased the scattering, and also to the decrease in absorption coefficient. SIGNIFICANCE: The proposed systematic approach was efficient for development of glass infiltrated ceramic composites with high translucency, which benefits include the better aesthetic performance of the final prosthesis.
Asunto(s)
Cerámica/síntesis química , Materiales Dentales/síntesis química , Luz , Ensayo de Materiales , Porosidad , Espectrofotometría/métodosRESUMEN
OBJECTIVES: To evaluate the effect of the microstructure on the Weibull and slow crack growth (SCG) parameters and on the lifetime of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ - Vita In-Ceram YZ; IZ - Vita In-Ceram Zirconia; AL - Vita In-Ceram AL) and of two veneering porcelains (VM7 and VM9). METHODS: Bar-shaped specimens were fabricated according to the manufacturer's instructions. Specimens were tested in three-point flexure in 37°C artificial saliva. Weibull analysis (n=30) and a constant stress-rate test (n=10) were used to determine the Weibull modulus (m) and SCG coefficient (n), respectively. Microstructural and fractographic analyzes were performed using SEM. ANOVA and Tukey's test (α=0.05) were used to statistically analyze data obtained with both microstructural and fractographic analyzes. RESULTS: YZ and AL presented high crystalline content and low porosity (0.1-0.2%). YZ had the highest characteristic strength (σ(0)) value (911MPa) followed by AL (488MPa) and IZ (423MPa). Lower σ(0) values were observed for the porcelains (68-75MPa). Except for IZ and VM7, m values were similar among the ceramic materials. Higher n values were found for YZ (76) and AL (72), followed by IZ (54) and the veneering materials (36-44). Lifetime predictions showed that YZ was the material with the best mechanical performance. The size of the critical flaw was similar among the framework materials (34-48µm) and among the porcelains (75-86µm). SIGNIFICANCE: The microstructure influenced the mechanical and SCG behavior of the studied materials and, consequently, the lifetime predictions.
Asunto(s)
Porcelana Dental/química , Fracaso de la Restauración Dental , Óxido de Aluminio , Silicatos de Aluminio , Cristalización , Análisis del Estrés Dental , Coronas con Frente Estético , Dentadura Parcial Fija , Elasticidad , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Porosidad , Compuestos de Potasio , Espectrometría por Rayos X , Propiedades de Superficie , Análisis de Supervivencia , Resistencia a la Tracción , Itrio , CirconioRESUMEN
OBJECTIVE: To evaluate the effect of the specimen design on the flexural strength (σ(f)) and failure mode of ceramic structures, testing the hypothesis that the ceramic material under tension controls the mechanical performance of the structure. METHODS: Three ceramics used as framework materials for fixed partial dentures (YZ--Vita In-Ceram YZ; IZ--Vita In-Ceram Zirconia; AL--Vita In-Ceram AL) and two veneering porcelains (VM7 and VM9) were studied. Bar-shaped specimens were produced in three different designs (n=10): monolithic, two layers (porcelain-framework) and three layers (TRI) (porcelain-framework-porcelain). Specimens were tested for three-point flexural strength at 1MPa/s in 37°C artificial saliva. For bi-layered design, the specimens were tested in both conditions: with porcelain (PT) or framework ceramic (FT) layer under tension. Fracture surfaces were analyzed using stereomicroscope and scanning electron microscopy (SEM). Young's modulus (E) and Poisson's ratio (ν) were determined using ultrasonic pulse-echo method. Results were statistically analyzed by Kruskal-Wallis and Student-Newman-Keuls tests. RESULTS: Except for VM7 and VM9, significant differences were observed for E values among the materials. YZ showed the highest ν value followed by IZ and AL. YZ presented the highest σ(f). There was no statistical difference in the σ(f) value between IZ and IZ-FT and between AL and AL-FT. σ(f) values for YZ-PT, IZ-PT, IZ-TRI, AL-PT, AL-TRI were similar to the results obtained for VM7 and VM9. Two types of fracture mode were identified: total and partial failure. SIGNIFICANCE: The mechanical performance of the specimens was determined by the material under tension during testing, confirming the study hypothesis.
Asunto(s)
Cerámica/química , Porcelana Dental/química , Algoritmos , Óxido de Aluminio/química , Silicatos de Aluminio/química , Pulido Dental , Análisis del Estrés Dental/instrumentación , Coronas con Frente Estético , Módulo de Elasticidad , Calor , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Docilidad , Compuestos de Potasio/química , Saliva Artificial/química , Estrés Mecánico , Propiedades de Superficie , Temperatura , Ultrasonido , Vacio , Itrio/química , Circonio/químicaRESUMEN
OBJECTIVE: To investigate the processing induced particle alignment on fracture behavior of four multiphase dental ceramics (one porcelain, two glass-ceramics and a glass-infiltrated-alumina composite). METHODS: Disks (Ø12 mm x 1.1mm-thick) and bars (3 mm x 4 mm x 20 mm) of each material were processed according to manufacturer instructions, machined and polished. Fracture toughness (K(Ic)) was determined by the indentation strength method using 3-point bending and biaxial flexure fixtures for the fracture of bars and disks, respectively. Microstructural and fractographic analyses were performed with scanning electron microscopy, energy dispersive spectroscopy and X-ray diffraction. RESULTS: The isotropic microstructure of the porcelain and the leucite-based glass-ceramic resulted in similar fracture toughness values regardless of the specimen geometry. On the other hand, materials containing second-phase particles with high aspect ratio (lithium disilicate glass-ceramic and glass-infiltrated-alumina composite) showed lower fracture toughness for disk specimens compared to bars. For the lithium disilicate glass-ceramic disks, it was demonstrated that the occurrence of particle alignment during the heat-pressing procedure resulted in an unfavorable pattern that created weak microstructural paths during the biaxial test. For the glass-infiltrated-alumina composite, the microstructural analysis showed that the large alumina platelets tended to align their large surfaces perpendicularly to the direction of particle deposition during slip casting of green preforms. SIGNIFICANCE: The fracture toughness of dental ceramics with anisotropic microstructure should be determined by means of biaxial testing, since it results in lower values.
Asunto(s)
Cerámica/química , Materiales Dentales/química , Algoritmos , Óxido de Aluminio/química , Silicatos de Aluminio/química , Anisotropía , Apatitas/química , Fenómenos Químicos , Pulido Dental , Porcelana Dental/química , Microanálisis por Sonda Electrónica , Vidrio/química , Humanos , Compuestos de Litio/química , Ensayo de Materiales , Fenómenos Mecánicos , Microscopía Electrónica de Rastreo , Estrés Mecánico , Propiedades de Superficie , Difracción de Rayos XRESUMEN
The aim of this study was to test the hypothesis that the addition of continuous or milled GdAlO3/Al2O3 fibers to a dental porcelain increases its mechanical properties. Porcelain bars without reinforcement (control) were compared to those reinforced with long fibers (30 vol%). Also, disk specimens reinforced with milled fibers were produced by adding 0 (control), 5 or 10 vol% of particles. The reinforcement with continuous fibers resulted in significant increase in the uniaxial flexural strength from 91.5 to 217.4 MPa. The addition of varied amounts of milled fibers to the porcelain did not significantly affect its biaxial flexural strength compared to the control group. SEM analysis showed that the interface between the continuous fiber and the porcelain was free of defects. On the other hand, it was possible to note the presence of cracks surrounding the milled fiber/porcelain interface. In conclusion, the reinforcement of the porcelain with continuous fibers resulted in an efficient mechanism to increase its mechanical properties; however the addition of milled fibers had no significant effect on the material because the porcelain was not able to wet the ceramic particles during the firing cycle.
Asunto(s)
Óxido de Aluminio/química , Porcelana Dental/química , Gadolinio/química , Módulo de Elasticidad , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Soporte de PesoRESUMEN
OBJECTIVES: To determine the effect of ion exchange on slow crack growth (SCG) parameters (n, stress corrosion susceptibility coefficient, and sigma(f0), scaling parameter) and Weibull parameters (m, Weibull modulus, and sigma(0), characteristic strength) of a dental porcelain. METHODS: 160 porcelain discs were fabricated according to manufacturer's instructions, polished through 1 microm and divided into two groups: GC (control) and GI (submitted to an ion exchange procedure using a KNO3 paste at 470 degrees C for 15 min). SCG parameters were determined by biaxial flexural strength test in artificial saliva at 37 degrees C using five constant stress rates (n=10). 20 specimens of each group were tested at 1 MPa/s to determine Weibull parameters. The SPT diagram was constructed using the least-squares fit of the strength data versus probability of failure. RESULTS: Mean values of m and sigma(0) (95% confidence interval), n and sigma(f0) (standard deviation) were, respectively: 13.8 (10.1-18.8) and 60.4 (58.5-62.2), 24.1 (2.5) and 58.1 (0.01) for GC and 7.4 (5.3-10.0) and 136.8 (129.1-144.7), 36.7 (7.3) and 127.9 (0.01) for GI. Fracture stresses (MPa) calculated using the SPT diagram for lifetimes of 1 day, 1 year and 10 years (at a 5% failure probability) were, respectively, 31.8, 24.9 and 22.7 for GC and 71.2, 60.6 and 56.9 for GI. SIGNIFICANCE: For the porcelain tested, the ion exchange process improved strength and resistance to SCG, however, the material's reliability decreased. The predicted fracture stress at 5% failure probability for a lifetime of 10 years was also higher for the ion treated group.