1.
Eur Radiol ; 34(4): 2699-2710, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37823922

RESUMEN

OBJECTIVES: MRI-derived extracellular volume (ECV) allows characterization of myocardial changes before the onset of overt pathology, which may be caused by cancer therapy cardiotoxicity. Our purpose was to review studies exploring the role of MRI-derived ECV as an early cardiotoxicity biomarker to guide timely intervention. MATERIALS AND METHODS: In April 2022, we performed a systematic search on EMBASE and PubMed for articles on MRI-derived ECV as a biomarker of cancer therapy cardiotoxicity. Two blinded researchers screened the retrieved articles, including those reporting ECV values at least 3 months from cardiotoxic treatment. Data extraction was performed for each article, including clinical and technical data, and ECV values. Pooled ECV was calculated using the random effects model and compared among different treatment regimens and among those who did or did not experience overt cardiac dysfunction. Meta-regression analyses were conducted to appraise which clinical or technical variables yielded a significant impact on ECV. RESULTS: Overall, 19 studies were included. Study populations ranged from 9 to 236 patients, for a total of 1123 individuals, with an average age ranging from 12.5 to 74 years. Most studies included patients with breast or esophageal cancer, treated with anthracyclines and chest radiotherapy. Pooled ECV was 28.44% (95% confidence interval, CI, 26.85-30.03%) among subjects who had undergone cardiotoxic cancer therapy, versus 25.23% (95%CI 23.31-27.14%) among those who had not (p = .003). CONCLUSION: A higher ECV in patients who underwent cardiotoxic treatment could imply subclinical changes in the myocardium, present even before overt cardiac pathology is detectable. CLINICAL RELEVANCE STATEMENT: The ability to detect subclinical changes in the myocardium displayed by ECV suggests its use as an early biomarker of cancer therapy-related cardiotoxicity. KEY POINTS: • Cardiotoxicity is a common adverse effect of cancer therapy; therefore, its prompt detection could improve patient outcomes. • Pooled MRI-derived myocardial extracellular volume was higher in patients who underwent cardiotoxic cancer therapy than in those who did not (28.44% versus 25.23%, p = .003). • MRI-derived myocardial extracellular volume represents a potential early biomarker of cancer therapy cardiotoxicity.


Asunto(s)
Cardiotoxicidad , Neoplasias , Humanos , Niño , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Cardiotoxicidad/diagnóstico por imagen , Cardiotoxicidad/etiología , Cardiotoxicidad/patología , Imagen por Resonancia Magnética , Miocardio/patología , Biomarcadores , Neoplasias/diagnóstico por imagen , Neoplasias/tratamiento farmacológico , Neoplasias/patología , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas
2.
J Clin Densitom ; 27(1): 101458, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38141277

RESUMEN

BACKGROUND: The FRAX® algorithm is a tool used to calculate the 10-year probability of fracture in patients with osteoporosis and is based the assessment of several risk factors. We assessed the performance and accuracy of the completion of the FRAX® anamnestic questionnaire by the radiographer without impact on the clinical workflow. METHODOLOGY: We evaluated the accuracy of fracture risk calculation by the radiographer using the FRAX® algorithm before and after specific training. A total of 100 women were enrolled in the study. The radiographer preliminarily administered the FRAX® questionnaire to all subjects before the execution of the DXA examination. After the end of the examination, a radiologist administered the questionnaire to the patient. Women were divided into two groups: group A (pre-training) and group B (post-training). The radiographer in group A completed the FRAX® questionnaire for the patients before training. For group B, the same radiographer completed the FRAX® questionnaire after training. The results of the FRAX® questionnaire completed by radiographer were compared with that completed by the referring physician. RESULTS: Before training, radiographer's accuracy ranged from 92% (question 7, alcohol consumption) to 36% (question 6, secondary osteoporosis). After training, accuracy values improved substantially, ranging from 100% to 92%. Analysis of the absolute values of FRAX® showed that in the pre-training group data tended to be overestimated by the radiographer, with both major and fractures probabilities being significantly higher when assessed by the radiographer (12% and 5.8%, respectively). After the training, there was a marked decrease in the variation between the FRAX® data calculated by the radiographer and the radiologist. CONCLUSIONS: The accuracy of fracture risk calculation by the radiographer using the FRAX® algorithm is significantly improved after a specific training period. This study demonstrates the importance of dedicated training radiographers on the FRAX® algorithm.


Asunto(s)
Fracturas Óseas , Osteoporosis , Fracturas Osteoporóticas , Humanos , Femenino , Absorciometría de Fotón , Densidad Ósea , Medición de Riesgo/métodos , Osteoporosis/complicaciones , Factores de Riesgo , Encuestas y Cuestionarios , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas Osteoporóticas/etiología
3.
Radiology ; 302(3): 568-581, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34904875

RESUMEN

Background Contrast-enhanced mammography (CEM) is a promising technique for breast cancer detection, but conflicting results have been reported in previous meta-analyses. Purpose To perform a systematic review and meta-analysis of CEM diagnostic performance considering different interpretation methods and clinical settings. Materials and Methods The MEDLINE, EMBASE, Web of Science, and Cochrane Library databases were systematically searched up to July 15, 2021. Prospective and retrospective studies evaluating CEM diagnostic performance with histopathology and/or follow-up as the reference standard were included. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Summary diagnostic odds ratio and area under the receiver operating characteristic curve were estimated with the hierarchical summary receiver operating characteristic (HSROC) model. Summary estimates of sensitivity and specificity were obtained with the hierarchical bivariate model, pooling studies with the same image interpretation approach or focused on the same findings. Heterogeneity was investigated through meta-regression and subgroup analysis. Results Sixty studies (67 study parts, 11 049 CEM examinations in 10 605 patients) were included. The overall area under the HSROC curve was 0.94 (95% CI: 0.91, 0.96). Pooled diagnostic odds ratio was 55.7 (95% CI: 42.7, 72.7) with high heterogeneity (τ2 = 0.3). At meta-regression, CEM interpretation with both low-energy and recombined images had higher sensitivity (95% vs 94%, P < .001) and specificity (81% vs 71%, P = .03) compared with recombined images alone. At subgroup analysis, CEM showed a 95% pooled sensitivity (95% CI: 92, 97) and a 78% pooled specificity (95% CI: 66, 87) from nine studies in patients with dense breasts, while in 10 studies on mammography-detected suspicious findings, CEM had a 92% pooled sensitivity (95% CI: 89, 94) and an 84% pooled specificity (95% CI: 73, 91). Conclusion Contrast-enhanced mammography demonstrated high performance in breast cancer detection, especially with joint interpretation of low-energy and recombined images. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Bahl in this issue.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Mamografía/métodos , Femenino , Humanos
4.
Neuroradiology ; 64(5): 905-913, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34647143

RESUMEN

PURPOSE: Imaging of brain involvement in infective endocarditis can drive the clinical management of this serious condition. MRI is very sensitive, but CT is more readily available. In this retrospective study, we compared the detection rates of CT and MRI. METHODS: After Ethics Committee approval, we retrospectively reviewed a series of 20 patients (13 males, median age 64 years) who underwent both CT and MRI either before or after cardiac surgery for definite infective endocarditis. Plain CT and MRI were evaluated for acute ischemic lesions, both punctuate and large, intraparenchymal hemorrhages, cerebral microbleeds, subarachnoid hemorrhages, abscesses, microabscesses, and meningitis. Qualitative assessment and McNemar test were performed. The value of contrast-enhanced scans (MRI, n = 14; CT, n = 9) and cognitive status were also assessed. RESULTS: A total of 166 lesions were identified on either technique: 137 (83%) on MRI only, 4 (2%) on CT only, and 25 (15%) on both techniques (p < 0.001). For these last 25 lesions, concordance on lesion type was only 16/25 (64%). MRI detected more microbleeds and ischemic lesions, while the 4 CT-only findings were false positives. Contrast-enhanced scans identified 68 enhancing lesions, mainly abscesses and microabscesses, and allowed a better characterization for 61/117 lesions (52%) with MRI, and for 11/81 (14%) with CT. Follow-up identified mild cognitive impairment in 6/13 and dementia in 3/13 patients. CONCLUSION: While CT rapidly excludes large hemorrhages in patients with infective endocarditis, MRI accurately distinguishes the whole spectrum of brain lesions, including small ischemic lesions, microbleeds, and microabscesses.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Endocarditis , Absceso/patología , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/patología , Endocarditis/diagnóstico por imagen , Endocarditis/patología , Endocarditis/cirugía , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
5.
J Magn Reson Imaging ; 53(6): 1732-1743, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33345393

RESUMEN

BACKGROUND: Although white matter hyperintensities (WMH) volumetric assessment is now customary in research studies, inconsistent WMH measures among homogenous populations may prevent the clinical usability of this biomarker. PURPOSE: To determine whether a point estimate and reference standard for WMH volume in the healthy aging population could be determined. STUDY TYPE: Systematic review and meta-analysis. POPULATION: In all, 9716 adult subjects from 38 studies reporting WMH volume were retrieved following a systematic search on EMBASE. FIELD STRENGTH/SEQUENCE: 1.0T, 1.5T, or 3.0T/fluid-attenuated inversion recovery (FLAIR) and/or proton density/T2 -weighted fast spin echo sequences or gradient echo T1 -weighted sequences. ASSESSMENT: After a literature search, sample size, demographics, magnetic field strength, MRI sequences, level of automation in WMH assessment, study population, and WMH volume were extracted. STATISTICAL TESTS: The pooled WMH volume with 95% confidence interval (CI) was calculated using the random-effect model. The I2 statistic was calculated as a measure of heterogeneity across studies. Meta-regression analysis of WMH volume on age was performed. RESULTS: Of the 38 studies analyzed, 17 reported WMH volume as the mean and standard deviation (SD) and were included in the meta-analysis. Mean and SD of age was 66.11 ± 10.92 years (percentage of men 50.45% ± 21.48%). Heterogeneity was very high (I2  = 99%). The pooled WMH volume was 4.70 cm3 (95% CI: 3.88-5.53 cm3 ). At meta-regression analysis, WMH volume was positively associated with subjects' age (ß = 0.358 cm3 per year, P < 0.05, R2  = 0.27). DATA CONCLUSION: The lack of standardization in the definition of WMH together with the high technical variability in assessment may explain a large component of the observed heterogeneity. Currently, volumes of WMH in healthy subjects are not comparable between studies and an estimate and reference interval could not be determined. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Asunto(s)
Sustancia Blanca , Adulto , Anciano , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Sustancia Blanca/diagnóstico por imagen
6.
Eur Radiol ; 31(8): 6248-6258, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33555356

RESUMEN

OBJECTIVES: To evaluate the diagnostic performance of dual-energy computed tomography (DECT) with regard to its post-processing techniques, namely linear blending (LB), iodine maps (IM), and virtual monoenergetic (VM) reconstructions, in diagnosing acute pulmonary embolism (PE). METHODS: This meta-analysis was conducted according to PRISMA. A systematic search on MEDLINE and EMBASE was performed in December 2019, looking for articles reporting the diagnostic performance of DECT on a per-patient level. Diagnostic performance meta-analyses were conducted grouping study parts according to DECT post-processing methods. Correlations between radiation or contrast dose and publication year were appraised. RESULTS: Seventeen studies entered the analysis. Only lobar and segmental acute PE were considered, subsegmental acute PE being excluded from analysis due to data heterogeneity or lack of data. LB alone was assessed in 6 study parts accounting for 348 patients, showing a pooled sensitivity of 0.87 and pooled specificity of 0.93. LB and IM together were assessed in 14 study parts accounting for 1007 patients, with a pooled sensitivity of 0.89 and pooled specificity of 0.90. LB, IM, and VM together were assessed in 2 studies (for a total 144 patients) and showed a pooled sensitivity of 0.90 and pooled specificity of 0.90. The area under the curve for LB alone, and LB together with IM was 0.93 (not available for studies using LB, IM and VM because of paucity of data). Radiation and contrast dose did not decrease with increasing year of publication. CONCLUSIONS: Considering the published performance of single-energy CT in diagnosing acute PE, either dual-energy or single-energy computed tomography can be comparably used for the detection of acute PE. KEY POINTS: • Dual-energy CT displayed pooled sensitivity and specificity of 0.87 and 0.93 for linear blending alone, 0.89 and 0.90 for linear blending and iodine maps, and 0.90 and 0.90 for linear blending iodine maps, and virtual monoenergetic reconstructions. • The performance of dual-energy CT for patient management is not superior to that reported in literature for single-energy CT (0.83 sensitivity and 0.96 specificity). • Dual-energy CT did not yield substantial advantages in the identification of patients with acute pulmonary embolism compared to single-energy techniques.


Asunto(s)
Embolia Pulmonar , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Embolia Pulmonar/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
7.
J Magn Reson Imaging ; 51(4): 1117-1127, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31515891

RESUMEN

BACKGROUND: MRI allows quantitatively assessing muscle quantity and quality. PURPOSE: To summarize the role of MRI as a noninvasive technique for the identification of in vivo surrogate biomarker of sarcopenia. STUDY TYPE: Systematic review. POPULATION: In April 2019, a systematic literature search (Medline/EMBASE) was performed to identify articles on the topic at issue. FIELD STRENGTH/SEQUENCE: No field strength or sequence restrictions. ASSESSMENT: After a literature search, study design, aim, sample size, demographics, magnetic field strength, imaged body region, MRI sequences, and imaging biomarker were extracted. STATISTICAL TESTS: Data are presented as frequencies and percentages. RESULTS: From 69 records identified through search query, 18 articles matched the inclusion criteria. All articles were published from 2012 and had a mainly prospective design (14/18, 78%). Sample size ranged from 9 to 284 subjects, for a total of 1706 enrolled subjects. Healthy subjects were enrolled or retrospectively selected in 8/18 (44%) articles, corresponding to 658 (39%) healthy subjects. Magnetic field strength was 1.5 or 3T in 14/18 (78%) studies. The most analyzed body regions were the thigh (7/18, 39%) and the trunk (6/18, 33%). Stratifying studies according to their aim, 13/18 (72%) studies focused on muscle quality and quantity, 3/18 (17%) studies on outcome prediction, and 2/18 articles (11%) addressed both aims. A wide set of MRI biomarkers have been proposed. Muscle cross-sectional area was the most used for muscle quantity estimation, while quantitative biomarkers of muscle fat content or fiber architecture were proposed to assess muscle quality. DATA CONCLUSION: The proposed biomarkers were assessed using different MRI sequences for different body regions in different subjects/patient cohorts, pointing out a lack of standardization on this topic. Future studies should test and compare the performance of proposed MRI biomarkers for sarcopenia characterization and quantification using a standardized experimental setup. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1117-1127.


Asunto(s)
Sarcopenia , Biomarcadores , Humanos , Imagen por Resonancia Magnética , Estudios Prospectivos , Estudios Retrospectivos , Sarcopenia/diagnóstico por imagen
8.
Eur Radiol ; 29(12): 7076-7077, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31278579

RESUMEN

The original version of this article, published on 02 May 2019, unfortunately contained a mistake. The following correction has therefore been made in the original: The presentation of Fig. 2 was incorrect. The corrected figure is given below. The original article has been corrected.

9.
Eur Radiol ; 29(12): 6620-6633, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31049734

RESUMEN

OBJECTIVES: To estimate the MRI-derived myocardial extracellular volume (ECV) in healthy subjects together with reference normality interval. METHODS: The study was registered on PROSPERO and reported according to PRISMA. In October 2017, a systematic search (MEDLINE/EMBASE) was performed for articles reporting MRI-derived ECV in healthy subjects. The pooled ECV (pECV) with 95% confidence interval (CI) was calculated using the random-effect model; the normality interval was calculated as pECV ± 2 root mean square of all study standard deviations. The Newcastle-Ottawa scale was used for assessing study quality, subgroup/meta-regression analyses for technical/biological covariates, and Egger test for publication bias risk. RESULTS: Of 282 articles, 56 were analyzed totaling 1851 subjects with age 16-68 years, body mass index 23-28 kg/m2, and left ventricular ejection fraction 58-74%. Contrast dose varied from 0.075 to 0.200 mmol/kg. Heterogeneity was high (I2 = 92%). The pECV was 25.6% (95% CI 25.2-26.0%) with a normality interval of 19.6-31.6%. pECV was slightly increasing with age (ß = 0.03%, p = 0.038) and slightly decreasing with the percentage of males (ß = - 0.02%, p = 0.053). Sequence type significantly (p = 0.003) impacted on pECV: the normal interval was 19.9-31.9% for MOLLI and 20.3-33.5% for ShMOLLI. Contrast type/dose, time of acquisition, and magnetic field strength did not significantly impact pECV (p > 0.093). Quality was moderate or high in 48/56 studies (86%). No risk of publication bias (p = 0.728). CONCLUSIONS: Myocardial pECV in healthy subjects was 25.6%, increasing by 0.03% for each year of age. The ECV normality interval was 19.9-31.9% for MOLLI and 20.3-33.5% for ShMOLLI. KEY POINTS: • The pooled estimate of normal MRI-derived ECV based on 1851 subjects was 25.6%, slightly increasing with age and slightly decreasing with the percentage of males. • MRI-derived ECV was independent of contrast type/dose and field strength but dependent on the imaging sequence. • The modeled normality reference interval of MRI-derived ECV was 19.9-31.9% for the MOLLI sequence and 20.3-33.5% for the ShMOLLI sequence.


Asunto(s)
Espacio Extracelular/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Miocardio/citología , Humanos , Valor Predictivo de las Pruebas , Valores de Referencia , Reproducibilidad de los Resultados
10.
Eur Spine J ; 27(11): 2781-2790, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30220040

RESUMEN

PURPOSE: To assess the methodologic quality of guidelines for the management of low back pain (LBP) and compare their recommendations. METHODS: No ethics committee approval was needed for this systematic review. In March 2017, a systematic search was performed using MEDLINE, EMBASE, National Guideline Clearinghouse, and National Institute for Health and Clinical Excellence to find practice guidelines of assessment and management of LBP. The evaluation of guidelines quality was performed independently by four authors using the AGREE II tool, and the results were compared with previous appraisals performed in 2004 and 2009. RESULTS: Of 114 retrieved guidelines, eight were appraised. All except one reached the level of "acceptable" in overall result, with two of them reaching the highest scores. Only two guidelines reached a level of "acceptable" in every domain; the others had at least one domain with low scores. The guidelines had the higher scores (range = 63-94%) on "Scope and purpose" and "Clarity of presentation" (47-89%). "Stakeholder Involvement" has the highest variability between the guidelines results (40-96%). "Rigor of Development" reached an intermediate mean result (34-90%), "Applicability" (42-70%), and "Editorial Independence" (38-85%). Only three guidelines had a radiologist among authors and reached higher scores compared to guidelines without a radiologist among the authors. Compared to previous assessments, low-level guidelines were 53% in 2004, 36% in 2009, and 13% in 2017. CONCLUSIONS: Considering all guidelines, only one had a "low" overall score, while half of them were rated as of "high" quality. Future guidelines might take this into account to improve clinical applicability.


Asunto(s)
Dolor de la Región Lumbar , Guías de Práctica Clínica como Asunto/normas , Humanos , Dolor de la Región Lumbar/diagnóstico , Dolor de la Región Lumbar/terapia
11.
Eur Radiol ; 27(7): 2989-2994, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27957643

RESUMEN

OBJECTIVES: To estimate the impact of endoaortic stents/mechanical heart valves on the output of an automatic exposure control (AEC) system and CT radiation dose. METHODS: In this phantom study, seven stents and two valves were scanned with varying tube voltage (80/100/120 kVp), AEC activation (enabled/disabled) and prosthesis (present/absent), for a total of 540 scans. For each prosthesis, the dose-length product (DLP) was compared between scans with the AEC enabled and disabled. Percentage confidence levels for differences due to the prosthesis were calculated. RESULTS: Differences between results with the AEC enabled and disabled were not statistically significant (p ≥ 0.059). In the comparison with and without the prosthesis, DLP was unchanged at 80 kVp and 100 kVp, while a slight increase was observed at 120 kVp. The radiation dose varied from 1.8 mGy to 2.4 mGy without the prosthesis and from 1.8 mGy to 2.5 mGy with the prosthesis (confidence level 37-100%). CONCLUSIONS: The effect of the prosthesis on the AEC system was negligible and not clinically relevant. Therefore, disabling the AEC system when scanning these patients is not likely to provide a benefit. KEY POINTS: • CT-AEC system is not impaired in patients with endoaortic prostheses/heart valves. • Negligible differences may be observed only at 120 kVp. • Disabling the AEC system in these patients is not recommended.


Asunto(s)
Prótesis Vascular , Prótesis Valvulares Cardíacas , Fantasmas de Imagen , Dosis de Radiación , Exposición a la Radiación/prevención & control , Stents , Tomografía Computarizada por Rayos X/instrumentación , Aorta/diagnóstico por imagen , Aorta/cirugía , Humanos
12.
Eur Radiol Exp ; 8(1): 35, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38418763

RESUMEN

OBJECTIVES: Energy consumption and carbon emissions from medical equipment like CT/MRI scanners and workstations contribute to the environmental impact of healthcare facilities. The aim of this systematic review was to identify all strategies to reduce energy use and carbon emissions in radiology. METHODS: In June 2023, a systematic review (Medline/Embase/Web of Science) was performed to search original articles on environmental sustainability in radiology. The extracted data include environmental sustainability topics (e.g., energy consumption, carbon footprint) and radiological devices involved. Sustainable actions and environmental impact in radiology settings were analyzed. Study quality was assessed using the QualSyst tool. RESULTS: From 918 retrieved articles, 16 met the inclusion criteria. Among them, main topics were energy consumption (10/16, 62.5%), life-cycle assessment (4/16, 25.0%), and carbon footprint (2/16, 12.5%). Eleven studies reported that 40-91% of the energy consumed by radiological devices can be defined as "nonproductive" (devices "on" but not working). Turning-off devices during idle periods 9/16 (56.2%) and implementing workflow informatic tools (2/16, 12.5%) were the sustainable actions identified. Energy-saving strategies were reported in 8/16 articles (50%), estimating annual savings of thousand kilowatt-hours (14,180-171,000 kWh). Cost-savings were identified in 7/16 (43.7%) articles, ranging from US $9,225 to 14,328 per device. Study quality was over or equal the 80% of high-quality level in 14/16 (87.5%) articles. CONCLUSION: Energy consumption and environmental sustainability in radiology received attention in literature. Sustainable actions include turning-off radiological devices during idle periods, favoring the most energy-efficient imaging devices, and educating radiological staff on energy-saving practices, without compromising service quality. RELEVANCE STATEMENT: A non-negligible number of articles - mainly coming from North America and Europe - highlighted the need for energy-saving strategies, attention to equipment life-cycle assessment, and carbon footprint reduction in radiology, with a potential for cost-saving outcome. KEY POINTS: • Energy consumption and environmental sustainability in radiology received attention in the literature (16 articles published from 2010 to 2023). • A substantial portion (40-91%) of the energy consumed by radiological devices was classified as "non-productive" (devices "on" but not working). • Sustainable action such as shutting down devices during idle periods was identified, with potential annual energy savings ranging from 14,180 to 171,000 kWh.


Asunto(s)
Huella de Carbono , Radiología , Humanos , Tomógrafos Computarizados por Rayos X , Imagen por Resonancia Magnética , Europa (Continente)
13.
Eur J Radiol ; 163: 110809, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37062205

RESUMEN

PURPOSE: To evaluate myocardial status through the assessment of extracellular volume (ECV) calculated at computed tomography (CT) in patients hospitalized for novel coronavirus disease (COVID-19), with regards to the presence of pulmonary embolism (PE) as a risk factor for cardiac dysfunction. METHOD: Hospitalized patients with COVID-19 who underwent contrast-enhanced CT at our institution were retrospectively included in this study and grouped with regards to the presence of PE. Unenhanced and portal venous phase scans were used to calculate ECV by placing regions of interest in the myocardial septum and left ventricular blood pool. ECV values were compared between patients with and without PE, and correlations between ECV values and clinical or technical variables were subsequently appraised. RESULTS: Ninety-four patients were included, 63/94 of whom males (67%), with a median age of 70 (IQR 56-76 years); 28/94 (30%) patients presented with PE. Patients with PE had a higher myocardial ECV than those without (33.5%, IQR 29.4-37.5% versus 29.8%, IQR 25.1-34.0%; p = 0.010). There were no correlations between ECV and patients' age (p = 0.870) or sex (p = 0.122), unenhanced scan voltage (p = 0.822), portal phase scan voltage (p = 0.631), overall radiation dose (p = 0.569), portal phase scan timing (p = 0.460), and contrast agent dose (p = 0.563). CONCLUSIONS: CT-derived ECV could help identify COVID-19 patients at higher risk of cardiac dysfunction, especially when related to PE, to potentially plan a dedicated, patient-tailored clinical approach.


Asunto(s)
COVID-19 , Cardiopatías , Embolia Pulmonar , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Miocardio , Tomografía Computarizada por Rayos X/métodos , Embolia Pulmonar/diagnóstico por imagen
14.
Eur Radiol Exp ; 7(1): 9, 2023 02 24.
Artículo en Inglés | MEDLINE | ID: mdl-36826698

RESUMEN

BACKGROUND: Our purpose was to evaluate the correlations between right ventricular (RV) late gadolinium enhancement (LGE) at cardiac magnetic resonance (CMR) in patients with tetralogy of Fallot (ToF) scheduled for pulmonary valve replacement (PVR) and post-PVR functional data. METHODS: We retrospectively reviewed ToF patients scheduled for PVR who underwent two CMR examinations at our institution, one before the procedure (CMR-0), including contrast-enhanced sequences, and one after the procedure (CMR-1). Functional left and RV data were obtained by segmenting short-axis stacks on both CMR examinations, and normalised variations were calculated by dividing differences between CMR-1 and CMR-0 by the intercurring time interval, whereas the RV scar burden was assessed on CMR-0 LGE sequences both semiquantitatively and quantitatively. Data were reported as median and interquartile range, differences were appraised with the Mann-Whitney U test, while correlations were assessed with Spearman's ρ. RESULTS: Fifteen patients with a median age of 25 years (16-29), including 9 (60%) males, with a median time interval between CMR-0 and CMR-1 of 17 months (12-23), were retrospectively reviewed. The semiquantitative LGE score at CMR-0 was 7 (6-9), and LGE volume was 4.49 mL (3.70-5.78), covering 5.63% (4.92-7.00) of the RV. RV LGE score showed a moderate positive correlation with the normalised variation of RV stroke volume (ρ = 0.662, p = 0.007) and a borderline moderate positive correlation with the normalised variation of RV end-diastolic indexed volume (ρ = 0.513, p = 0.050). CONCLUSIONS: The assessment of RV LGE before PVR may provide insights on post-PVR functional data, potentially facilitating a patient-tailored treatment pathway.


Asunto(s)
Válvula Pulmonar , Tetralogía de Fallot , Masculino , Humanos , Adolescente , Adulto Joven , Adulto , Femenino , Tetralogía de Fallot/cirugía , Válvula Pulmonar/cirugía , Medios de Contraste , Gadolinio , Estudios Retrospectivos
15.
Eur Radiol Exp ; 7(1): 27, 2023 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-37142839

RESUMEN

The potential enviromental impact of iodinated (ICAs) and gadolinium-based contrast agents (GBCAs) have recently come under scrutiny, considering the current nonselective wastewater treatment. However, their rapid excretion after intravenous administration could allow their potential recovery by targeting hospital sewage. The GREENWATER study aims to appraise the effective quantities of ICAs and GBCAs retrievable from patients' urine collected after computed tomography (CT) and magnetic resonance imaging (MRI) exams, selecting ICA/GBCA per-patient urinary excretion and patients' acceptance rate as study endpoints. Within a prospective, observational, single-centre, 1-year framework, we will enrol outpatients aged ≥ 18 years, scheduled to perform contrast-enhanced CT or MRI, willing to collect post-examination urine in dedicated canisters by prolonging their hospital stay to 1 h after injection. Collected urine will be processed and partially stored in the institutional biobank. Patient-based analysis will be performed for the first 100 CT and 100 MRI patients, and then, all analyses will be conducted on the pooled urinary sample. Quantification of urinary iodine and gadolinium will be performed with spectroscopy after oxidative digestion. The evaluation of the acceptance rate will assess the "environmental awareness" of patients and will aid to model how procedures to reduce ICA/GBCA enviromental impact could be adapted in different settings. Key points • Enviromental impact of iodinated and gadolinium-based contrast agents represents a growing point of attention.• Current wastewater treatment is unable to retrieve and recycle contrast agents.• Prolonging hospital stay may allow contrast agents retrieval from patients' urine.• The GREENWATER study will assess the effectively retrievable contrast agents' quantities.• The enrolment acceptance rate will allow to evaluate patients' "green sensitivity".


Asunto(s)
Medios de Contraste , Aguas Residuales , Humanos , Gadolinio/orina , Hospitales , Estudios Prospectivos , Sustancias Reductoras , Estudios Observacionales como Asunto
16.
Eur Radiol Exp ; 6(1): 42, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-35989400

RESUMEN

Magnetic resonance imaging (MRI) is an important part of breast cancer diagnosis and multimodal workup. It provides unsurpassed soft tissue contrast to analyse the underlying pathophysiology, and it is adopted for a variety of clinical indications. Predictive and prognostic breast MRI (P2-bMRI) is an emerging application next to these indications. The general objective of P2-bMRI is to provide predictive and/or prognostic biomarkers in order to support personalisation of breast cancer treatment. We believe P2-bMRI has a great clinical potential, thanks to the in vivo examination of the whole tumour and of the surrounding tissue, establishing a link between pathophysiology and response to therapy (prediction) as well as patient outcome (prognostication). The tools used for P2-bMRI cover a wide spectrum: standard and advanced multiparametric pulse sequences; structured reporting criteria (for instance BI-RADS descriptors); artificial intelligence methods, including machine learning (with emphasis on radiomics data analysis); and deep learning that have shown compelling potential for this purpose. P2-bMRI reuses the imaging data of examinations performed in the current practice. Accordingly, P2-bMRI could optimise clinical workflow, enabling cost savings and ultimately improving personalisation of treatment. This review introduces the concept of P2-bMRI, focusing on the clinical application of P2-bMRI by using semantic criteria.


Asunto(s)
Inteligencia Artificial , Neoplasias de la Mama , Mama/diagnóstico por imagen , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Pronóstico
17.
Otol Neurotol ; 43(10): 1108-1115, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36214510

RESUMEN

OBJECTIVES: The aim of this review is to assess the methodological quality of guidelines for the management of vertigo and dizziness and to compare their recommendations, with specific focus on neuroimaging. DATABASES REVIEWED: MEDLINE, EMBASE, National Guideline Clearinghouse, and National Institute for Health and Clinical Excellence database. METHODS: In March 2022, a systematic search was performed to find practice guidelines of management of vertigo and dizziness. The evaluation of guidelines quality was performed independently by four authors using the AGREE II tool. We excluded from the results those guidelines that were not primarily focused on vertigo and dizziness, such as national/international guidelines in which vertigo and dizziness were only briefly mentioned. RESULTS: Our strategy of literature search identified 161 studies, and 18 guidelines were selected for the appraisal. Only five guidelines reached the acceptance level in the overall result (at least 60%), with three of them reaching the highest scores (at least 80%). The highest scores were found in Domain 6 "Editorial Independence," Domain 1 "Scope and purpose," and Domain 4 "Clarity of presentation" (median value = 66%, 62%, and 61%, respectively). The remaining domains showed a low level of quality: Domain 2 "Stakeholder Involvement," Domain 3 "Rigor of development," and Domain 5 "Applicability" had median values of 27%, 27%, and 22%, respectively. The quality of these guidelines was very low, because of low involvement of multidisciplinary teams in writing guidelines recommendations. CONCLUSION: Considering all guidelines, only three had a "high" overall score, whereas 13 of 18 (72%) of them were rated as of "low" quality. Future guidelines might take this into account to improve clinical applicability.


Asunto(s)
Mareo , Vértigo , Humanos , Mareo/terapia , Bases de Datos Factuales , Vértigo/terapia
18.
J Med Imaging Radiat Sci ; 53(1): 58-64, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35115275

RESUMEN

INTRODUCTION: Radiation therapy technologists (RTTs) are exposed to high stress levels which may lead to burnout, which could be further increased by the current pandemic. The aim of our study was to assess burnout and stress among Italian RTTs before and during the pandemic. METHODS: The Italian Association of Radiation Therapy and Medical Physics Technologists (AITRO) and the Italian Federation of Scientific Radiographers Societies (FASTeR) proposed a national online survey, including the Maslach Burnout Inventory assessing emotional exhaustion (EE), depersonalisation (DP), and personal accomplishment (PA) to RTTs before and during the pandemic. Multivariate regression analyses and χ2 tests were used for data analysis. RESULTS: We obtained 367 answers, 246 before and 121 during the pandemic. RTTs before and during the pandemic showed high EE and DP, intermediate PA. Median EE was 37 (interquartile range [IQR] 31-46] before and 37 (IQR 30-43) during the pandemic, median DP was 16 (IQR 13-21) and 15 (IQR 12-20), respectively. PA was 31 (IQR 28-34) and 32 (IQR 28-34), respectively. Through multivariate analysis, being female and having children led to higher EE scores before and during the pandemic (p≤0.026). Only the presence of workplace stress management courses was related to lower DP before and being female was related to higher DP during the pandemic (p<0.001). Being female, having children, and working with paediatric patients were related to lower PA before and during the pandemic (p≤0.015). CONCLUSION: Our study highlighted high burnout levels for RTTs regardless of the pandemic. Future interventions aimed at preventing burnout should be implemented in their work environment, independently of the impact of exceptional events.


Asunto(s)
Agotamiento Profesional , COVID-19 , Agotamiento Profesional/epidemiología , Niño , Femenino , Humanos , Pandemias , SARS-CoV-2 , Encuestas y Cuestionarios
19.
Brain Imaging Behav ; 16(4): 1721-1731, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35266099

RESUMEN

Life expectancy in adults with congenital heart disease (ACHD) has increased. As these patients grow older, they experience aging-related diseases more than their healthy peers. To better characterize this field, we launched the multi-disciplinary BACH (Brain Aging in Congenital Heart disease) San Donato study, that aimed at investigating signs of brain injury in ACHD. Twenty-three adults with repaired tetralogy of Fallot and 23 age- and sex-matched healthy controls were prospectively recruited and underwent brain magnetic resonance imaging. White matter hyperintensities (WMHs) were segmented using a machine-learning approach and automatically split into periventricular and deep. Cerebral microbleeds were manually counted. A subset of 14 patients were also assessed with an extensive neuropsychological battery. Age was 41.78 ± 10.33 years (mean ± standard deviation) for patients and 41.48 ± 10.28 years for controls (p = 0.921). Albeit not significantly, total brain (p = 0.282) and brain tissue volumes (p = 0.539 for cerebrospinal fluid, p = 0.661 for grey matter, p = 0.793 for white matter) were lower in ACHD, while total volume (p = 0.283) and sub-classes of WMHs (p = 0.386 for periventricular WMHs and p = 0.138 for deep WMHs) were higher in ACHD than in controls. Deep WMHs were associated with poorer performance at the frontal assessment battery (r = -0.650, p = 0.012). Also, patients had a much larger number of microbleeds than controls (median and interquartile range 5 [3-11] and 0 [0-0] respectively; p < 0.001). In this study, adults with tetralogy of Fallot showed specific signs of brain injury, with some clinical implications. Eventually, accurate characterization of brain health using neuroimaging and neuropsychological data would aid in the identification of ACHD patients at risk of cognitive deterioration.


Asunto(s)
Enfermedades de los Pequeños Vasos Cerebrales , Tetralogía de Fallot , Adulto , Encéfalo/diagnóstico por imagen , Estudios de Casos y Controles , Enfermedades de los Pequeños Vasos Cerebrales/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tetralogía de Fallot/complicaciones , Tetralogía de Fallot/cirugía
20.
Eur J Radiol ; 136: 109521, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33450661

RESUMEN

PURPOSE: The aim of this study is to review the literature concerning myocardial late gadolinium enhancement (LGE) with cardiac magnetic resonance in patients with Tetralogy of Fallot (ToF), with regards to its prevalence, characteristics and clinical relevance. METHODS: We performed a systematic search, aiming to retrieve original articles that evaluated LGE in ToF, running a search string on MEDLINE and EMBASE in November 2019 and November 2020. Papers were then selected by two independent, blinded readers based on title and abstract, and then on full-text reading, and articles which did not include LGE evaluation were excluded. From each included paper two readers extracted descriptive data concerning technical parameters of LGE acquisition, LGE description and clinical significance. RESULTS: 18 articles were eventually included in our review. The included studies observed that a higher amount of right ventricular LGE relates with higher right ventricular volumes, lower ejection fraction and a higher pulmonary regurgitant fraction, thus acting as a marker of progressive impairment of myocardial function. Moreover, LGE in ToF patients correlated with the onset of arrhythmias, and with serum biomarkers indicative of myocardial stress and fibrosis. CONCLUSIONS: LGE could be used in the follow-up repaired ToF patients as its appraisal can provide information concerning cardiac dysfunction. Moreover, it may be ideal to aim towards a common framework for standardizing assessment and quantification of LGE in ToF patients.


Asunto(s)
Gadolinio , Tetralogía de Fallot , Medios de Contraste , Fibrosis , Ventrículos Cardíacos/patología , Humanos , Imagen por Resonancia Cinemagnética , Miocardio/patología , Valor Predictivo de las Pruebas , Tetralogía de Fallot/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS