Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Opt Lett ; 49(3): 678-681, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38300088

RESUMEN

Characterizing laser frequency noise is essential for applications including optical sensing and coherent optical communications. Accurate measurement of ultra-narrow linewidth lasers over a wide frequency range using existing methods is still challenging. Here we present a method for characterizing the frequency noise of lasers using a high-finesse plano-concave optical microresonator (PCMR) acting as a frequency discriminator. To enable noise measurements at a wide range of laser frequencies, an array of PCMRs was produced with slight variations of thickness resulting in a series of discriminators operating at a series of periodical frequencies. This method enables measuring the frequency noise over a wide linewidth range (15 Hz to <100 MHz) over the 1440-1630 nm wavelength range. To assess the performance of the method, four different lasers were characterized, and the results were compared to the estimations of a commercial frequency noise analyzer.

2.
Opt Express ; 31(10): 16523-16534, 2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37157729

RESUMEN

Plano-concave optical microresonators (PCMRs) are optical microcavities formed of one planar and one concave mirror separated by a spacer. PCMRs illuminated by Gaussian laser beams are used as sensors and filters in fields including quantum electrodynamics, temperature sensing, and photoacoustic imaging. To predict characteristics such as the sensitivity of PCMRs, a model of Gaussian beam propagation through PCMRs based on the ABCD matrix method was developed. To validate the model, interferometer transfer functions (ITFs) calculated for a range of PCMRs and beams were compared to experimental measurements. A good agreement was observed, suggesting the model is valid. It could therefore constitute a useful tool for designing and evaluating PCMR systems in various fields. The computer code implementing the model has been made available online.

3.
Opt Express ; 30(26): 46404-46417, 2022 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-36558595

RESUMEN

A numerical model of Gaussian beam propagation in planar Fabry-Perot (FP) etalons is presented. The model is based on the ABCD transfer matrix method. This method is easy to use and interpret, and readily connects models of lenses, mirrors, fibres and other optics to aid simulating complex multi-component etalon systems. To validate the etalon model, its predictions were verified using a previously validated model based on Fourier optics. To demonstrate its utility, three different etalon systems were simulated. The results suggest the model is valid and versatile and could aid in designing and understanding a range of systems containing planar FP etalons. The method could be extended to model higher order beams, other FP type devices such as plano-concave resonators, and more complex etalon systems such as those involving tilted components.

4.
Opt Express ; 28(5): 7691-7706, 2020 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-32225991

RESUMEN

Fabry-Pérot (FP) etalons are used as filters and sensors in a range of optical systems. Often FP etalons are illuminated by collimated laser beams, in which case the transmitted and reflected light fields can be calculated analytically using well established models. However, FP etalons are sometimes illuminated by more complex beams such as focussed Gaussian beams, which may also be aberrated. Modelling the response of FP etalons to these beams requires a more sophisticated model. To address this need, we present a model that can describe the response of an FP etalon that is illuminated by an arbitrary beam. The model uses an electromagnetic wave description of light and can therefore compute the amplitude, phase and polarization of the optical field at any position in the system. It can also account for common light delivery and detection components such as lenses, optical fibres and photo-detectors, allowing practical systems to be simulated. The model was validated against wavelength resolved measurements of transmittance and reflectance obtained using a system consisting of an FP etalon illuminated by a focussed Gaussian beam. Experiments with focal spot sizes ranging from 30 µm to 250 µm and FP etalon mirror reflectivities in the range 97.2 % to 99.2 % yielded excellent visual agreement between simulated and experimental data and an average error below 10% for a range of quantitative comparative metrics. We expect the model to be a useful tool for designing, understanding and optimising systems that use FP etalons.

5.
Opt Lett ; 45(22): 6238-6241, 2020 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-33186959

RESUMEN

A miniature flexible photoacoustic endoscopy probe that provides high-resolution 3D images of vascular structures in the forward-viewing configuration is described. A planar Fabry-Perot ultrasound sensor with a -3dB bandwidth of 53 MHz located at the tip of the probe is interrogated via a flexible fiber bundle and a miniature optical relay system to realize an all-optical probe measuring 7.4 mm in outer diameter at the tip. This approach to photoacoustic endoscopy offers advantages over previous piezoelectric based distal-end scanning probes. These include a forward-viewing configuration in widefield photoacoustic tomography mode, finer spatial sampling (87 µm spatial sampling interval), and wider detection bandwidth (53 MHz) than has been achievable with conventional ultrasound detection technology and an all-optical passive imaging head for safe endoscopic use.


Asunto(s)
Endoscopios , Miniaturización/instrumentación , Fibras Ópticas , Técnicas Fotoacústicas/instrumentación , Cirugía Asistida por Computador/instrumentación , Diseño de Equipo , Fenómenos Mecánicos , Seguridad , Tomografía
6.
Opt Express ; 27(26): 37886-37899, 2019 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-31878562

RESUMEN

Photoacoustic imaging systems based on a Fabry Perot (FP) ultrasound sensor that is read-out by scanning a free-space laser beam over its surface can provide high resolution photoacoustic images. However, this type of free-space scanning usually requires a bulky 2-axis galvanometer based scanner that is not conducive to the realization of a lightweight compact imaging head. It is also unsuitable for endoscopic applications that may require complex and flexible access. To address these limitations, the use of a flexible, coherent fibre bundle to interrogate the FP sensor has been investigated. A laboratory set-up comprising an x-y scanner, a commercially available, 1.35 mm diameter, 18,000 core flexible fibre bundle with a custom-designed telecentric optical relay at its distal end was used. Measurements of the optical and acoustic performance of the FP sensor were made and compared to that obtained using a conventional free-space FP based scanner. Spatial variations in acoustic sensitivity were greater and the SNR lower with the fibre bundle implementation but high quality photoacoustic images could still be obtained. 3D images of phantoms and ex vivo tissues with a spatial resolution and fidelity consistent with a free-space scanner were acquired. By demonstrating the feasibility of interrogating the FP sensor with a flexible fibre bundle, this study advances the realization of compact hand-held clinical scanners and flexible endoscopic devices based on the FP sensing concept.

7.
Biomed Opt Express ; 14(8): 4052-4064, 2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37799692

RESUMEN

All-optical ultrasound (OpUS) is an imaging paradigm that uses light to both generate and receive ultrasound, and has progressed from benchtop to in vivo studies in recent years, demonstrating promise for minimally invasive surgical applications. In this work, we present a rapid pullback imaging catheter for side-viewing B-mode ultrasound imaging within the upper gastrointestinal tract. The device comprised an ultrasound transmitter configured to generate ultrasound laterally from the catheter and a plano-concave microresonator for ultrasound reception. This imaging probe was capable of generating ultrasound pressures in excess of 1 MPa with corresponding -6 dB bandwidths > 20 MHz. This enabled imaging resolutions as low as 45 µm and 120 µm in the axial and lateral extent respectively, with a corresponding signal-to-noise ratio (SNR) of 42 dB. To demonstrate the potential of the device for clinical imaging, an ex vivo swine oesophagus was imaged using the working channel of a mock endoscope for device delivery. The full thickness of the oesophagus was resolved and several tissue layers were present in the resulting ultrasound images. This work demonstrates the promise for OpUS to provide rapid diagnostics and guidance alongside conventional endoscopy.

8.
Biomed Opt Express ; 14(7): 3446-3457, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37497509

RESUMEN

All-optical ultrasound (OpUS) has emerged as an imaging paradigm well-suited to minimally invasive imaging due to its ability to provide high resolution imaging from miniaturised fibre optic devices. Here, we report a fibre optic device capable of concurrent laser interstitial thermal therapy (LITT) and real-time in situ all-optical ultrasound imaging for lesion monitoring. The device comprised three optical fibres: one each for ultrasound transmission, reception and thermal therapy light delivery. This device had a total lateral dimension of <1 mm and was integrated into a medical needle. Simultaneous LITT and monitoring were performed on ex vivo lamb kidney with lesion depth tracked using M-mode OpUS imaging. Using one set of laser energy parameters for LITT (5 W, 60 s), the lesion depth varied from 3.3 mm to 8.3 mm. In all cases, the full lesion depth could be visualised and measured with the OpUS images and there was a good statistical agreement with stereomicroscope images acquired after ablation (t=1.36, p=0.18). This work demonstrates the feasibility and potential of OpUS to guide LITT in tumour resection.

9.
Commun Eng ; 1(1)2022 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37033302

RESUMEN

All-optical ultrasound (OpUS) is an emerging high resolution imaging paradigm utilising optical fibres. This allows both therapeutic and imaging modalities to be integrated into devices with dimensions small enough for minimally invasive surgical applications. Here we report a dual-modality fibre optic probe that synchronously performs laser ablation and real-time all-optical ultrasound imaging for ablation monitoring. The device comprises three optical fibres: one each for transmission and reception of ultrasound, and one for the delivery of laser light for ablation. The total device diameter is < 1 mm. Ablation monitoring was carried out on porcine liver and heart tissue ex vivo with ablation depth tracked using all-optical M-mode ultrasound imaging and lesion boundary identification using a segmentation algorithm. Ablation depths up to 2.1 mm were visualised with a good correspondence between the ultrasound depth measurements and visual inspection of the lesions using stereomicroscopy. This work demonstrates the potential for OpUS probes to guide minimally invasive ablation procedures in real time.

10.
Biomed Opt Express ; 13(7): 4047-4057, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35991929

RESUMEN

All-optical ultrasound (OpUS), where ultrasound is both generated and received using light, has emerged as a modality well-suited to highly miniaturised applications. In this work we present a proof-of-concept OpUS transducer built onto a single optical fibre with a highly miniaturised lateral dimension (<0.8 mm). A key innovation was to use a dual-clad optical fibre (DCF) to provide multimode light for ultrasound generation and single mode light for ultrasound reception. The transducer comprised a proximal section of DCF spliced to a short section of single mode fibre (SMF). Multimode light was outcoupled at the splice joint and guided within a square capillary to provide excitation for ultrasound generation. Whilst single mode light was guided to the distal tip of the SMF to a plano-concave microresonator for ultrasound reception. The device was capable of generating ultrasound with pressures >0.4 MPa and a corresponding bandwidth >27 MHz. Concurrent ultrasound generation and reception from the transducer enabled imaging via motorised pull-back allowing image acquisition times of 4 s for an aperture of 20 mm. Image resolution was as low as ~50 µm and 190 µm in the axial and lateral extents, respectively, without the need for image reconstruction. Porcine aorta was imaged ex vivo demonstrating detailed ultrasound images. The unprecedented level of miniaturisation along with the high image quality produced by this device represents a radical new paradigm for minimally invasive imaging.

11.
Ultrasound Med Biol ; 48(3): 520-529, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34974926

RESUMEN

Accurate identification of the needle tip is a key challenge with ultrasound-guided percutaneous interventions in regional anaesthesia, foetal surgery and cardiovascular medicine. In this study, we developed an ultrasonic needle tracking system in which the measured needle tip location was used to set the electronic focus of the external ultrasound imaging probe. In this system, needle tip tracking was enabled with a fibre-optic ultrasound sensor that was integrated into a needle stylet, and the A-lines recorded by the sensor were processed to generate tracking images of the needle tip. The needle tip position was estimated from the tracking images. The dependency of the tracking image on the electronic focal depth of the external ultrasound imaging probe was studied in a water bath and with needle insertions into a clinical training phantom. The variability in the estimated tracked position of the needle tip, with the needle tip at fixed depths in the imaging plane across a depth range from 0.5 to 7.5 cm, was studied. When the electronic focus was fixed, the variability of tracked position was found to increase with distance from that focus. The variability with the fixed focus was found to depend on the the relative distance between the needle tip and focal depth. It was found that with dynamic focusing, the maximum variability of tracked position was below 0.31 mm, as compared with 3.97 mm for a fixed focus.


Asunto(s)
Agujas , Ultrasonido , Electrónica , Fantasmas de Imagen , Ultrasonografía , Ultrasonografía Intervencional/métodos
12.
Eur J Med Chem ; 229: 113996, 2022 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-34802837

RESUMEN

Established roles for PI3K and MAPK signaling pathways in tumorigenesis has prompted extensive research towards the discovery of small-molecule inhibitors as cancer therapeutics. However, significant compensatory regulation exists between these two signaling cascades, leading to redundancy among survival pathways. Consequently, initial clinical trials aimed at either PI3K or MEK inhibition alone have proven ineffective and highlight the need for development of targeted and innovative therapeutic combination strategies. We designed a series of PI3K inhibitor derivatives wherein a single morpholine group of the PI3K inhibitor ZSTK474 was substituted with a variety of 2-aminoethyl functional groups. Analogs with pendant hydroxyl or methoxy groups maintained low nanomolar inhibition towards PI3Kα, PI3Kγ, and PI3Kδ isoforms in contrast to those with pendant amino groups which were significantly less inhibitory. Synthesis of prototype PI3K/MEK bifunctional inhibitors (6r, 6s) was guided by the structure-activity data, where a MEK-targeting inhibitor was tethered directly via a short PEG linker to the triazine core of the PI3K inhibitor analogs. These compounds (6r, 6s) displayed nanomolar inhibition towards PI3Kα, δ, and MEK (IC50 ∼105-350 nM), and low micromolar inhibition for PI3Kß and PI3Kγ (IC50 ∼1.5-3.9 µM) in enzymatic inhibition assays. Cell viability assays demonstrated superior anti-proliferative activity for 6s over 6r in three tumor-derived cell lines (A375, D54, SET-2), which correlated with inhibition of downstream AKT and ERK1/2 phosphorylation. Compounds 6r and 6s also demonstrated in vivo tolerability with therapeutic efficacy through reduction of kinase activation and amelioration of disease phenotypes in the JAK2V617F mutant myelofibrosis mouse cancer model. Taken together, these results support further structure optimization of 6r and 6s as promising leads for combination therapy in human cancer as a new class of PI3K/MEK bifunctional inhibitors.


Asunto(s)
Quinasas de Proteína Quinasa Activadas por Mitógenos/antagonistas & inhibidores , Morfolinas/química , Fosfatidilinositol 3-Quinasas/química , Inhibidores de las Quinasa Fosfoinosítidos-3/química , Triazinas/química , Animales , Sitios de Unión , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Modelos Animales de Enfermedad , Humanos , Ratones , Ratones Transgénicos , Quinasas de Proteína Quinasa Activadas por Mitógenos/metabolismo , Simulación del Acoplamiento Molecular , Fosfatidilinositol 3-Quinasas/metabolismo , Inhibidores de las Quinasa Fosfoinosítidos-3/metabolismo , Inhibidores de las Quinasa Fosfoinosítidos-3/uso terapéutico , Mielofibrosis Primaria/tratamiento farmacológico , Isoformas de Proteínas/antagonistas & inhibidores , Isoformas de Proteínas/metabolismo , Relación Estructura-Actividad , Triazinas/metabolismo , Triazinas/uso terapéutico
13.
Nat Commun ; 13(1): 4730, 2022 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-35977945

RESUMEN

Activation of compensatory signaling nodes in cancer often requires combination therapies that are frequently plagued by dose-limiting toxicities. Intestinal lymphatic drug absorption is seldom explored, although reduced toxicity and sustained drug levels would be anticipated to improve systemic bioavailability. A potent orally bioavailable multi-functional kinase inhibitor (LP-182) is described with intrinsic lymphatic partitioning for the combined targeting of phosphoinositide 3-kinase (PI3K) and mitogen-activated protein kinase (MAPK) signaling pathways without observable toxicity. We demonstrate selectivity and therapeutic efficacy through reduction of downstream kinase activation, amelioration of disease phenotypes, and improved survival in animal models of myelofibrosis. Our further characterization of synthetic and physiochemical properties for small molecule lymphatic uptake will support continued advancements in lymphatropic therapy for altering disease trajectories of a myriad of human disease indications.


Asunto(s)
Antineoplásicos , Mielofibrosis Primaria , Animales , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Línea Celular Tumoral , Humanos , Sistema de Señalización de MAP Quinasas , Fosfatidilinositol 3-Quinasas/metabolismo , Mielofibrosis Primaria/tratamiento farmacológico , Inhibidores de Proteínas Quinasas/farmacología , Inhibidores de Proteínas Quinasas/uso terapéutico
14.
Ultrasonics ; 116: 106514, 2021 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-34280811

RESUMEN

All-optical ultrasound (AOUS) imaging, which uses light to both generate and detect ultrasound, is an emerging alternative to conventional electronic ultrasound imaging. To date, AOUS imaging has been performed using paradigms that either resulted in long acquisition times or employed bench-top imaging systems that were impractical for clinical use. In this work, we present a novel AOUS imaging paradigm where scanning optics are used to rapidly synthesise an imaging aperture. This paradigm enabled the first AOUS system with a flexible, handheld imaging probe, which represents a critical step towards clinical translation. This probe, which provides video-rate imaging and a real-time display, is demonstrated with phantoms and in vivo human tissue.

15.
Adv Mater Interfaces ; 8(20): 2100518, 2021 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-34777946

RESUMEN

Dual-modality imaging employing complementary modalities, such as all-optical ultrasound and photoacoustic imaging, is emerging as a well-suited technique for guiding minimally invasive surgical procedures. Quantum dots are a promising material for use in these dual-modality imaging devices as they can provide wavelength-selective optical absorption. The first quantum dot nanocomposite engineered for co-registered laser-generated ultrasound and photoacoustic imaging is presented. The nanocomposites developed, comprising CuInS2 quantum dots and medical-grade polydimethylsiloxane (CIS-PDMS), are applied onto the distal ends of miniature optical fibers. The films exhibit wavelength-selective optical properties, with high optical absorption (> 90%) at 532 nm for ultrasound generation, and low optical absorption (< 5%) at near-infrared wavelengths greater than 700 nm. Under pulsed laser irradiation, the CIS-PDMS films generate ultrasound with pressures exceeding 3.5 MPa, with a corresponding bandwidth of 18 MHz. An ultrasound transducer is fabricated by pairing the coated optical fiber with a Fabry-Pérot (FP) fiber optic sensor. The wavelength-selective nature of the film is exploited to enable co-registered all-optical ultrasound and photoacoustic imaging of an ink-filled tube phantom. This work demonstrates the potential for quantum dots as wavelength-selective absorbers for all-optical ultrasound generation.

16.
Biomed Opt Express ; 11(10): 5717-5727, 2020 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-33149981

RESUMEN

We present a minimally-invasive endoscope based on a multimode fiber that combines photoacoustic and fluorescence sensing. From the measurement of a transmission matrix during a prior calibration step, a focused spot is produced and raster-scanned over a sample at the distal tip of the fiber by use of a fast spatial light modulator. An ultra-sensitive fiber-optic ultrasound sensor for photoacoustic detection placed next to the fiber is combined with a photodetector to obtain both fluorescence and photoacoustic images with a distal imaging tip no larger than 250 µm. The high signal-to-noise ratio provided by wavefront shaping based focusing and the ultra-sensitive ultrasound sensor enables imaging with a single laser shot per pixel, demonstrating fast two-dimensional hybrid in vitro imaging of red blood cells and fluorescent beads.

17.
Head Neck ; 42(10): 2779-2781, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32621399

RESUMEN

Respiratory particle generation and dispersal during nasoendoscopy and swab testing is studied with high-speed video and laser light illumination. Video analysis reveals droplet formation in three manoeuvres during nasoendoscopy - sneezing, vocalization, and nasal decongestion spray. A capillary bridge of mucus can be seen when a nasoendoscope exits wet nares. No droplet formation is seen during oral and nasopharyngeal swab testing. We outline the following recommendations: pull the face mask down partially and keep the mouth covered, only allowing nasal access during nasoendoscopy; avoid nasal sprays if possible; if nasal sprays are used, procedurists should be in full personal protective equipment prior to using the spray; withdrawal of swabs and scopes should be performed in a slow and controlled fashion to reduce potential dispersion of droplets when the capillary bridge of mucus breaks up.


Asunto(s)
Prueba de COVID-19 , Endoscopía , Moco , Cavidad Nasal , Fonación/fisiología , Estornudo/fisiología , Administración Intranasal , Humanos , Control de Infecciones , Transmisión de Enfermedad Infecciosa de Paciente a Profesional , Rociadores Nasales , Equipo de Protección Personal
18.
Artículo en Inglés | MEDLINE | ID: mdl-31180849

RESUMEN

Planar glass-etalon Fabry-Pérot (FP) optical ultrasound sensors offer an alternative to piezoelectric sensors for the measurements of high-intensity focused ultrasound (HIFU) fields and other metrological applications. In this work, a model of the frequency-dependent directional response of the FP sensor was developed using the global matrix method, treating the sensor as a multilayered elastic structure. The model was validated against the experimentally measured directional response of an air-backed cover-slip FP sensor with well-known material properties. In addition, the model was compared with the measurements of an all-hard-dielectric sensor suitable for HIFU measurements. The model was then used to calculate modal dispersion curves for both glass-etalon sensors, allowing the features of the directional response to be linked to specific wave phenomena. The features in the directivity of the air-backed cover-slip sensor are due to guided Lamb waves. Symmetric Lamb modes give rise to regions of high sensitivity, whereas anti-symmetric modes cause regions of low sensitivity. For the all-hard-dielectric sensor, two features correspond to the water-substrate and water-spacer compressional and shear critical angles. A region of high sensitivity close to the shear critical angle is associated with a leaky-Rayleigh wave, which has a frequency-dependent phase speed. At higher frequencies, this feature is counteracted by a region of low sensitivity, which occurs when there is no difference in the vertical displacement of the mirrors forming the FP cavity. The model may be used to improve and optimize the design of FP sensors or could be used to assist with the accurate deconvolution of the directional response from array measurements in metrological and imaging applications.

19.
Sci Rep ; 9(1): 5576, 2019 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-30944379

RESUMEN

Miniaturised high-resolution imaging devices are valuable for guiding minimally invasive procedures such as vascular stent placements. Here, we present all-optical rotational B-mode pulse-echo ultrasound imaging. With this device, ultrasound transmission and reception are performed with light. The all-optical transducer in the probe comprised an optical fibre that delivered pulsed excitation light to an optical head at the distal end with a multi-walled carbon nanotube and polydimethylsiloxane composite coating. This coating was photoacoustically excited to generate a highly directional ultrasound beam perpendicular to the optical fibre axis. A concave Fabry-Pérot cavity at the distal end of an optical fibre, which was interrogated with a tuneable continuous-wave laser, served as an omnidirectional ultrasound receiver. The transmitted ultrasound had a -6 dB bandwidth of 31.3 MHz and a peak-to-peak pressure of 1.87 MPa, as measured at 1.5 mm from the probe. The receiver had a noise equivalent pressure <100 Pa over a 20 MHz bandwidth. With a maximum outer probe diameter of 1.25 mm, the probe provided imaging with an axial resolution better than 50 µm, and a real-time imaging rate of 5 frames per second. To investigate the capabilities of the probe, intraluminal imaging was performed in healthy swine carotid arteries. The results demonstrate that the all-optical probe is viable for clinical rotational ultrasound imaging.

20.
Light Sci Appl ; 7: 75, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30323927

RESUMEN

A miniature forward-viewing endoscopic probe that provides high-resolution 3D photoacoustic images is demonstrated. The probe is of outer diameter 3.2 mm and comprised of a transparent Fabry-Pérot (FP) polymer-film ultrasound sensor that is located at the distal end of a rigid optical fiber bundle. Excitation laser pulses are coupled simultaneously into all cores of the bundle and are transmitted through the FP sensor to provide wide-field tissue illumination at the distal end. The resulting photoacoustic waves are mapped in 2D by sequentially scanning the input end of the bundle with an interrogation laser beam in order to individually address different points on the FP sensor. In this way, the sensor acts as a high-density ultrasound array that is comprised of 50,000 individual elements, each of which is 12 µm in diameter, within the 3.2 mm diameter footprint of the probe. The fine spatial sampling that this affords, along with the wide bandwidth (f -3dB = 34 MHz) of the sensor, enables a high-resolution photoacoustic image to be reconstructed. The measured on-axis lateral resolution of the probe was depth-dependent and ranged from 45-170 µm for depths between 1 and 7 mm, and the vertical resolution was 31 µm over the same depth range. The system was evaluated by acquiring 3D images of absorbing phantoms and the microvascular anatomies of a duck embryo and mouse skin. Excellent image fidelity was demonstrated. It is anticipated that this type of probe could find application as a tool for guiding laparoscopic procedures, fetal surgery and other minimally invasive interventions that require a millimeter-scale forward-viewing 3D photoacoustic imaging probe.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA