Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Mikrochim Acta ; 191(5): 281, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38649632

RESUMEN

Two chiral covalent organic frameworks (CCOFs) core-shell microspheres based on achiral organic precursors by chiral-induced synthesis strategy for HPLC enantioseparation are reported for the first time. Using n-hexane/isopropanol as mobile phase, various kinds of racemates were selected as analytes and separated on the CCOF-TpPa-1@SiO2 and CCOF-TpBD@SiO2-packed columns with a low column backpressure (3 ~ 9 bar). The fabricated two CCOFs@SiO2 chiral columns exhibited good separation performance towards various racemates with high column efficiency (e.g., 19,500 plates m-1 for (4-fluorophenyl)ethanol and 18,900 plates m-1 for 1-(4-chlorophenyl)ethanol) and good reproducibility. Some effects have been investigated such as the analyte mass and column temperature on the HPLC enantioseparation. Moreover, the chiral separation results of the CCOF-TpPa-1@SiO2 chiral column and the commercialized Chiralpak AD-H column show a good complementarity. This study demonstrates that the usage of chiral-induced synthesis strategy for preparing CCOFs core-shell microspheres as a novel stationary phase has a good application potential in HPLC.

2.
Mikrochim Acta ; 191(8): 445, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38958767

RESUMEN

A novel CCOF core-shell composite material (S)-DTP-COF@SiO2 was prepared via asymmetric catalytic and in situ growth strategy. The prepared (S)-DTP-COF@SiO2 was utilized as separation medium for HPLC enantioseparation using normal-phase and reversed-phase chromatographic modes, which displays excellent chiral separation performance for alcohols, esters, ketones, and epoxides, etc. Compared with chiral commercial chromatographic columns (Chiralpak AD-H and Chiralcel OD-H columns) and some previously reported chiral CCOF@SiO2 (CC-MP CCTF@SiO2 and MDI-ß-CD-modified COF@SiO2)-packed columns, there are 4, 3, 13, and 15 tested racemic compounds that could not be resolved on the Chiralpak AD-H column, Chiralcel OD-H column, CC-MP CCTF@SiO2 column, and MDI-ß-CD-modified COF@SiO2 column, respectively, which indicates that the resolution effect of (S)-DTP-COF@SiO2-packed column can be complementary to the other ones. The effects of the analyte mass, column temperature, and mobile phase composition on the enantiomeric separation were investigated. The chiral column exhibits good reproducibility after multiple consecutive injections. The RSDs (n = 5) of the peak area and retention time were less than 1.5% for repetitive separation of 2-methoxy-2-phenylethanol and 1-phenyl-1-pentanol. The chiral core-shell composite (S)-DTP-COF@SiO2 exhibited good enantiomeric separation performance, which not only demonstrates its potential as a novel CSP material in HPLC but also expands the range of applications for chiral COFs.

3.
Anal Chem ; 95(35): 13289-13296, 2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37615071

RESUMEN

Metallacycles are a novel class of supramolecular materials with circular structures, internal cavities, and abundant host-guest chemical properties that have exhibited good application prospects in many fields. However, to the best of our knowledge, no research on the use of metallacycles as stationary phases for gas chromatographic (GC) separations has been published yet. In this work, we report for the first time the use of a homochiral metallacycle, [ZnCl2L]2, as a stationary phase for GC separations. [ZnCl2L]2 was synthesized by reaction of (S)-(1-isonicotinoylpyrrolidin-2-yl)methyl-isonicotinate (L) with ZnCl2 via coordination-driven self-assembly. The [ZnCl2L]2-coated column displayed an excellent separation performance not only of organic isomers but also of racemic compounds. Sixteen racemates (including alcohols, esters, amino acid derivatives, ethers, organic acids, and epoxides) and 21 isomeric compounds (including positional, structural, and cis/trans-isomers) were well separated on the [ZnCl2L]2-coated column. Impressively, some racemates were resolved with high resolution values (Rs), including 1,2-butanediol diacetate (Rs = 25.86), ethyl 3-hydroxybutyrate (Rs = 20.97), 1,3-butanediol diacetate (Rs = 18.09), and threonine derivative (Rs = 18.61). Compared with the commercial ß-DEX 120 column for separation of the tested racemates, the [ZnCl2L]2-coated column exhibited good enantioseparation complementarity, enabling separation of some racemates that could not be separated, or were not well resolved, by the ß-DEX 120 column. In addition, many organic mixtures, such as n-alkanes, alkylbenzenes, n-alcohols, and a Grob test mixture, were also well separated on the [ZnCl2L]2-coated column. The column also has good reproducibility and thermal stability on separation. This work not only reveals the great potential of metallacycles for GC separations but also opens up a new application of metallacycles in separation science.

4.
J Sep Sci ; 46(18): e2300376, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37525411

RESUMEN

A chiral pillar[3]trianglimine (C60 H72 N6 O6 ) with a deep cavity has been developed as a chiral selector and bonded to thiolated silica by thiol-ene click reaction to fabricate a novel chiral stationary phase for enantioseparation in high-performance liquid chromatography. The enantioseparation performance of the fabricated chiral stationary phase has been evaluated by separating various racemic compounds, including alcohols, esters, amines, ketones, amino acids, and epoxides, in both normal-phase and reversed-phase elution modes. In total, 14 and 17 racemates have been effectively separated in these two separation modes, respectively. In comparison with two widely used chiral columns (Chiralcel OD-H and Chiralpak AD-H), our novel chiral stationary phase offered good chiral separation complementarity, separating some of the tested racemates that could not be separated or were only partially separated on these two commercial columns. The influences of analyte mass, mobile phase composition, and column temperature on chiral separation have been investigated. Good repeatability, stability, and column-to-column reproducibility of the chiral stationary phase for enantioseparation have been observed. After the fabricated column had been eluted up to 400 times, the relative standard deviations (n = 5) of resolution (Rs) and retention time of the separated analytes were < 0.39% and < 0.20%, respectively. The relative standard deviations (n = 3) of Rs and retention time for column-to-column reproducibility were < 4.6% and < 5.2%, respectively. This study demonstrated that the new chiral stationary phase has great prospects for chiral separation in high-performance liquid chromatography.

5.
Mikrochim Acta ; 190(6): 238, 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37222823

RESUMEN

The manufacturing of chiral covalent triazine framework core-shell microspheres CC-MP CCTF@SiO2 composite is reported as stationary phase for HPLC enantioseparation. The CC-MP CCTF@SiO2 core-shell microspheres were prepared by immobilizing chiral COF CC-MP CCTF constructed using cyanuric chloride and (S)-2-methylpiperazine on the surface of activated SiO2 through an in-situ growth approach. Various racemates as analytes were separated on the CC-MP CCTF@SiO2-packed column. The experimental results indicate that 19 pairs of enantiomers were well separated on the CC-MP CCTF@SiO2-packed column, including alcohols, phenols, amines, ketones, and organic acids. Among them, there are 17 pairs of enantiomers that can achieve baseline separation with good peak shapes. Their resolution values on this chiral column are between 0.4 and 5.61. The influences of analyte mass, column temperature, and composition of the mobile phase on the resolution of enantiomers were studied. In addition, the chiral resolution ability of CC-MP CCTF@SiO2-packed column was compared with the commercial chiral chromatographic columns (Chiralpak AD-H and Chiralcel OD-H columns) and some CCOF@SiO2 chiral columns (ß-CD-COF@SiO2, CTpBD@SiO2, and MDI-ß-CD-modified COF@SiO2). The CC-MP CCTF@SiO2-packed column exhibited some unique advantages and can complement these chiral columns in chiral separations. The research results show that the CC-MP CCTF@SiO2 chiral column offered high column efficiency (e.g., 17680 plates m-1 for ethyl mandelate), low column backpressure (5-9 bar), high enantioselectivity, and excellent chiral resolution ability for HPLC enantioseparation with good stability and reproducibility. The relative standard deviations (RSD) (n = 5) of the retention time, and peak areas by repeated separation of ethyl mandelate are 0.23% and 0.67%, respectively. It demonstrates that the CC-MP CCTF@SiO2 core-shell microsphere composite has great potential in enantiomeric separation by HPLC.

6.
Molecules ; 28(7)2023 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-37049997

RESUMEN

Porous organic cages (POCs) are a new subclass of porous materials, which are constructed from discrete cage molecules with permanent cavities via weak intermolecular forces. In this study, a novel chiral stationary phase (CSP) has been prepared by chemically binding a [4 + 6]-type chiral POC (C120H96N12O4) with thiol-functionalized silica gel using a thiol-ene click reaction and applied to HPLC separations. The column packed with this CSP presented good separation capability for chiral compounds and positional isomers. Thirteen racemates have been enantioseparated on this column, including alcohols, diols, ketones, amines, epoxides, and organic acids. Upon comparison with a previously reported chiral POC NC1-R-based column, commercial Chiralpak AD-H, and Chiralcel OD-H columns, this column is complementary to these three columns in terms of its enantiomeric separation; and can also separate some racemic compounds that cannot be separated by the three columns. In addition, eight positional isomers (iodoaniline, bromoaniline, chloroaniline, dibromobenzene, dichlorobenzene, toluidine, nitrobromobenzene, and nitroaniline) have also been separated. The influences of the injection weight and column temperature on separation have been explored. After the column has undergone multiple injections, the relative standard deviations (RSDs) for the retention time and selectivity were below 1.0 and 1.5%, respectively, indicating the good reproducibility and stability of the column for separation. This work demonstrates that POCs are promising materials for HPLC separation.

7.
Anal Chem ; 94(12): 4961-4969, 2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35306818

RESUMEN

Porous organic cages (POCs) are an emerging class of porous materials that have aroused considerable research interest because of their unique characteristics, including good solubility and a well-defined intrinsic cavity. However, there have so far been no reports of chiral POCs as chiral stationary phases (CSPs) for enantioseparation by high-performance liquid chromatography (HPLC). Herein, we report the first immobilization of a chiral POC, NC1-R, on thiol-functionalized silica using a mild thiol-ene click reaction to prepare novel CSPs for HPLC. Two CSPs (CSP-1 and CSP-2) with different spacers have been prepared. CSP-1, with a cationic imidazolium spacer, exhibited excellent enantioselectivity for the resolution of various racemates. Twenty-three and 12 racemic compounds or chiral drugs were well enantioseparated on the CSP-1-packed column under normal-phase and reversed-phase conditions, respectively, including alcohols, diols, esters, ethers, ketones, epoxides, organic acids, and amines. In contrast, chiral resolution using CSP-2 (without a cationic imidazolium spacer)-packed column B was inferior to that of column A, demonstrating the important role of the cationic imidazolium spacer for chiral separation. The chiral separation capability of column A was also compared with that of two most popular commercial chiral columns, Chiralpak AD-H and Chiralcel OD-H, which exhibits good chiral recognition complementarity with the two commercial chiral columns. In addition, five positional isomers dinitrobenzene, nitroaniline, chloroaniline, bromoaniline, and iodoaniline were also well separated on column A. The effects of temperature, mobile phase composition, and injected analyte mass for separation on column A were investigated. Column A also showed good stability and reproducibility after repeated injections. This work demonstrates that chiral POCs are promising chiral materials for HPLC enantioseparation.


Asunto(s)
Química Clic , Compuestos de Sulfhidrilo , Aminas , Cationes , Cromatografía Líquida de Alta Presión/métodos , Porosidad , Reproducibilidad de los Resultados , Estereoisomerismo , Compuestos de Sulfhidrilo/química
8.
BMC Infect Dis ; 22(1): 663, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35915398

RESUMEN

BACKGROUND: China has experienced a continuous decreasing trend in the incidence of hepatitis A in recent years. Temporal trend analyses are helpful in exploring the reasons for the changing trend. Thus, this study aims to analyse the incidence trend of viral hepatitis A by region and age group in mainland China from 2004 to 2017 to evaluate the effectiveness of prevention and control measures. METHODS: Data on hepatitis A and population information were collected and analysed with a joinpoint regression model. Annual percentage changes (APCs) and average annual percentage changes (AAPCs) were estimated for the whole country and for each region and age group. RESULTS: From 2004 to 2017, the seasonality and periodicity of hepatitis A case numbers were obvious before 2008 but gradually diminished from 2008 to 2011 and disappeared from 2012-2017. The national incidence of hepatitis A (AAPC = - 12.1%) and the incidence rates for regions and age groups showed decreasing trends, with differences in the joinpoints and segments. Regarding regions, the hepatitis A incidence in the western region was always the highest among all regions, while a nonsignificant rebound was observed in the northeastern region from 2011 to 2017 (APC = 14.2%). Regarding age groups, the hepatitis A incidence showed the fastest decrease among children (AAPC = - 15.3%) and the slowest decrease among elderly individuals (AAPC = - 6.6%). Among all segments, the hepatitis A incidence among children had the largest APC value in 2007-2017, at - 20.4%. CONCLUSION: The national annual incidence of hepatitis A continually declined from 2004 to 2017 and the gaps in hepatitis A incidence rates across different regions and age groups were greatly narrowed. Comprehensive hepatitis A prevention and control strategies, including the use of routine vaccination during childhood in mainland China, especially the implementation of the national Expanded Program on Immunization (EPI) in 2008, resulted in substantial progress from 2004 to 2017. However, gaps remain. Regular monitoring and analysis of hepatitis A epidemic data and prompt adjustment of hepatitis A prevention and control strategies focusing on children, elderly individuals and those living in certain regions are recommended.


Asunto(s)
Hepatitis A , Poliposis Adenomatosa del Colon , Anciano , Niño , China/epidemiología , Hepatitis A/epidemiología , Humanos , Programas de Inmunización , Incidencia , Análisis de Regresión
9.
J Sep Sci ; 45(1): 51-77, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34729907

RESUMEN

Separations and analyses of chiral compounds are important in many fields, including pharmaceutical production, preparation of chemical intermediates, and biochemistry. High-performance liquid chromatography using a chiral stationary phase is regarded as one of the most valuable methods for enantiomeric separation and analysis because it is highly efficient, is broadly applicable, and has powerful separation capability. The focus for development of this method is the identification of novel chiral stationary phases with superior recognition performance and good stability. The present article reviews recent progress in the development of new chiral stationary phases for high-performance liquid chromatography between January 2018 and June 2021. These newly reported chiral stationary phases are divided into three categories: small organic molecule-based (cyclodextrin and its derivatives, macrocyclic antibiotics, cinchona alkaloids, and other low molecular weight chiral molecules), macromolecule-based (cellulose and amylose derivatives, chitin and chitosan derivatives, and synthetic helical polymers) and chiral porous material-based (chiral metal-organic frameworks, chiral covalent organic frameworks, and chiral inorganic mesoporous silicas). Each type of chiral stationary phase is discussed in detail.

10.
J Sep Sci ; 45(18): 3510-3519, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35880615

RESUMEN

Chiral metal-organic frameworks have shown great potential in enantioselective separation and asymmetric catalysis due to their diverse and adjustable structures with abundant chiral recognition sites. Herein, a new chiral post-synthetic modification was used for preparing an achiral@chiral metal-organic frameworks core-shell composite [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco] by a superficial chiral etching method. The [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco] composite was utilized as a novel chiral stationary phase for HPLC enantioseparation. Various racemates were separated on the [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco]-packed column (column A). It exhibited good chiral resolving ability toward many different kinds of racemates, especially chiral drugs. Among them, the highest resolution value for 1,2-diphenyl-1,2-ethanediol reaches 2.70. The relative standard deviations of retention time and peak area for repeated separation of 1,2-diphenyl-1,2-ethanol were 0.45% and 0.81%, respectively. Compared with the resolution ability of [Cu2 ((+)-Cam)2 Dabco]-packed column (column B), column A shows higher column efficiency and better separation performance than those of column B. The results indicated that the [Cu3 (Btc)2 ]@[Cu2 ((+)-Cam)2 Dabco] as a stationary phase can greatly improve the column efficiency and chiral resolution ability of chiral metal-organic frameworks, which demonstrated that the superficial chiral etching as an economic and efficient strategy opens up a new way for the application of metal-organic frameworks.


Asunto(s)
Estructuras Metalorgánicas , Compuestos de Bifenilo , Cromatografía Líquida de Alta Presión/métodos , Etanol , Glicol de Etileno , Estructuras Metalorgánicas/química , Estereoisomerismo
11.
Mikrochim Acta ; 189(9): 360, 2022 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-36042107

RESUMEN

A spherical chiral porous organic polymer (POPs) COP-1 is synthesized by the Friedel-Crafts alkylation reaction of Boc-3-(4-biphenyl)-L-alanine (BBLA) and 4,4'-bis(chloromethyl)-1,1'-biphenyl (BCMBP), which was used as a novel chiral stationary phase (CSPs) for mixed-mode high-performance liquid chromatography (HPLC) enantioseparation. The racemic compounds were resolved in normal-phase liquid chromatography (NPLC) using n-hexane/isopropanol as mobile phase and reversed-phase liquid chromatography (RPLC) using methanol/water as mobile phase. The COP-1-packed column exhibited excellent separation performance toward various racemic compounds including alcohols, amines, ketones, esters, epoxy compounds, organic acids, and amino acids in NPLC and RPLC modes. The effects of analyte mass and column temperature on the separation efficiency of racemic compounds were investigated. In addition, the chiral resolution ability of the COP-1-packed column not only can be complementary in RPLC/NPLC modes but also exhibit a good chiral recognition complementarity with Chiralpak AD-H column and chiral porous organic cage (POC) NC1-R column. The relative standard deviations (RSD) (n = 5) of the retention time, resolution value, and peak area by repeated separation of 1-(4-chiorophenyl)ethanol are all below 3.0%. The COP-1 column shows high column efficiency (e.g., 17,320 plates m-1 for 1-(4-chlorophenyl)ethanol on COP-1 column in NPLC), high enantioselectivity, and good reproducibility toward various racemates. This work demonstrates that chiral POPs microspheres are promising chiral materials for HPLC enantioseparation.


Asunto(s)
Aminas , Polímeros , Cromatografía Líquida de Alta Presión/métodos , Etanol , Porosidad , Reproducibilidad de los Resultados , Estereoisomerismo
12.
J Sep Sci ; 44(21): 3976-3985, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34490989

RESUMEN

The unique features of uniform and adjustable cavities, abundant chiral active sites, and high enantioselectivity make chiral metal-organic frameworks popular as an emerging candidate for enantioselective separation. However, the wide particle size distribution and irregular shape of as-synthesized metal-organic frameworks result in low column efficiency, undesired chromatographic peak shape, and high column backpressure of such metal-organic frameworks packed columns. Herein, we report the fabrication of chiral core-shell microspheres [Cu2 (d-Cam)2 (4,4'-bpy)]n @SiO2 composite for high-performance liquid chromatography enantioseparation to overcome the above-mentioned problems. The [Cu2 (d-Cam)2 (4,4'-bpy)]n @SiO2 packed column gave high-resolution separation of racemates under low column backpressure (10-22 bar), indicating its synergistic effect of the good column packing property of the SiO2 microspheres and the chiral recognition ability of [Cu2 (d-Cam)2 (4,4'-bpy)]n crystals. Thirteen kinds of chiral compounds including alcohols, amines, ketones, epoxides, and organic bases were well separated with good peak shapes and high column efficiency (18200 plates/m for 1-(9-anthryl)-2,2,2-trifluoroethanol) on the [Cu2 (d-Cam)2 (4,4'-bpy)]n @SiO2 packed column. Among them, seven pairs of enantiomers achieved baseline separation and the resolution value for 1-(9-anthryl)-2,2,2-trifluoroethanol reached 11.22. Some effects such as column temperature, and analytes mass on the enantioseparations have been investigated. In addition, the [Cu2 (d-Cam)2 (4,4'-bpy)]n @SiO2 packed column exhibited good stability and repeatability for the separation of chiral compounds. The relative standard deviations for five replicate separations of 1-phenylethanol were less than 1.0, 1.5, 3.0, and 2.0% for the retention time, peak area, number of theoretical plates, and resolution, respectively. The research results demonstrated the development of chiral metal-organic frameworks core-shell microspheres composite provide a promising platform for their practical application in chiral separation fields.

13.
Mikrochim Acta ; 188(9): 292, 2021 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-34363124

RESUMEN

The fascinating framework structures and unique properties of chiral covalent organic frameworks (COFs) make them promising candidates as novel separation medium for high-performance liquid chromatography (HPLC). However, the irregular morphology, inhomogeneous particle size, and low density of conventional COF particles will lead to a low column efficiency, undesirable chromatographic peak shape, and high column backpressure of such COF-packed columns. In this work, a chiral COF CTpBD was synthesized by the Schiff base reaction between benzidine (BD) and chiral organic monomer CTp obtained through the reaction of 1,3,5-triformylphoroglucinol (Tp) and (+)-diacetyl-L-tartaric anhydride ((+)-Ac-L-Ta). The chiral COF CTpBD was immobilized on the surface of amino functionalized silica (SiO2-NH2) by an in situ growth approach to prepare the chiral COF core-shell microsphere composite CTpBD@SiO2, which was used as a novel chiral stationary phase (CSP) for HPLC enantioseparation. Various kinds of racemates were separated on the CTpBD@SiO2-packed column with a low column backpressure (8-11 bar). Some effects such as the analyte mass and column temperature on the HPLC enantioseparation have been studied in detail. The fabricated CTpBD@SiO2-packed column exhibited high column efficiency (e.g., 16,800 plates m-1 for atenolol), high enantioselectivity, and good reproducibility toward various racemates. The highest resolution value, retention factor, and separation factor reach to 2.11, 2.85, and 3.73, respectively. The relative standard deviations (RSD) of peak area, peak height, half-peak width, and retention time of atenolol were all below 3.0%.

14.
Electrophoresis ; 41(1-2): 104-111, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31709552

RESUMEN

Since some metal-organic cages (MOCs) have been synthesized in past several years, the applications of MOCs such as drug delivery, molecular recognition, separation, catalysis, and gas storage, etc. have been witnessed with a significant increase. However, to the best of our knowledge, so far no one has used MOCs as chiral stationary phase to separate chiral compounds in CEC. In this study, three MOCs were developed as the stationary phase for CEC separation of enantiomers. The MOCs coated capillary column showed good chiral recognition ability for some chiral compounds, including amine, alcohols, ketone, etc. The influence of buffer concentration, applied voltage, pH of buffer solution on the chiral separations was also investigated. The RSDs of run-to-run, day-to-day, and column-to-column for retention time were 2.1-4.67%, 1.2-4.36%, and 3.62-6.43%, respectively. This work reveals that the chiral MOCs material is feasible for the enantioseparation in CEC.


Asunto(s)
Electrocromatografía Capilar/instrumentación , Compuestos Organometálicos/química , Electrocromatografía Capilar/métodos , Reproducibilidad de los Resultados , Estereoisomerismo , Zinc/química
15.
J Sep Sci ; 43(1): 134-149, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31587485

RESUMEN

Porous materials with well-defined pore structures have received considerable attention in the past decades due to their unique structures and wide applications. Most porous materials such as zeolites, metal-organic frameworks, covalent organic frameworks, and porous organic polymers are extended to infinite frameworks or networks by robust covalent or coordination bonds. Porous molecular cages composed of discrete molecules with permanent cavities are an emerging class of porous material and the discrete molecules assemble into solids by weak intermolecular interaction. In comparison to porous extended solids such as metal-organic frameworks and covalent organic frameworks, porous molecular cage solids are generally soluble in organic solvents thus allowing solution processing, making them more convenient to apply in many fields. This review mainly focuses on the recent advances of application of porous molecular cages (porous organic cages and metal-organic cages) for enantioselective recognition and separation from 2010 to present, including gas chromatography, capillary electrochromatography, chiral fluorescent recognition, chiral potentiometric sensing, and enantioselective adsorption. Furthermore, the two important family members of porous molecular cages, porous organic cages and metal-organic cages, are also discussed.

16.
BMC Musculoskelet Disord ; 21(1): 52, 2020 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-31996263

RESUMEN

BACKGROUND: Arthroscopic surgery procedures vary depending on the types of meniscus tear, including meniscectomy and meniscus repair. Among the several types of meniscus tear, the horizontal tear of the lateral meniscus at the popliteal hiatus region is a common injury, and its surgical treatment is still inconsistent. METHODS: Between January 2018 and October 2018, 20 patients who underwent all-inside repair with suture hook for the horizontal tear of the lateral meniscus at the popliteal hiatus region were recruited. Any operative complication was recorded, and postoperative MRI scans were conducted at the 6 months. The clinical results were graded based on the scale of the Lysholm knee score preoperatively and at follow-up. RESULTS: No operative complications were recorded. Postoperative MRIs at the 6 months showed that there was no re-tear for all patients, though signal intensity remained high in T2-weighted MRI in the lateral meniscus for nine cases. The average preoperative Lysholm knee score was 58.6 ± 10.1, which increased significantly to 89.3 ± 7.8 (t = - 11.01, p = 0.001) at the last follow-up. Recurrence or aggravation of symptoms was not noted at the final follow-up. CONCLUSION: All-inside repair with suture hook may be a good option for the horizontal tear of the lateral meniscus at the popliteal hiatus region which preserves the meniscus; avoids iatrogenic injury on the adjacent popliteal tendon, common peroneal nerve, and inferior lateral geniculate artery.


Asunto(s)
Artroscopía/métodos , Instrumentos Quirúrgicos , Técnicas de Sutura , Lesiones de Menisco Tibial/diagnóstico por imagen , Lesiones de Menisco Tibial/cirugía , Adulto , Artroscopía/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Meniscos Tibiales/diagnóstico por imagen , Meniscos Tibiales/cirugía , Persona de Mediana Edad , Técnicas de Sutura/instrumentación , Suturas
17.
BMC Musculoskelet Disord ; 21(1): 210, 2020 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-32252730

RESUMEN

BACKGROUND: When reconstructing a hip with developmental dysplasia and high dislocation, sub-trochanteric shortening osteotomy is typically needed for placing the acetabular component in the appropriate anatomical position. However, the procedure can result in complications such as non-union of the osteotomy. We evaluated the contact area and the coincidence rate between the proximal and distal fragments at different femoral osteotomy levels and lengths. We then determined the optimal location of subtrochanteric femoral shortening transverse osteotomy in patients with unilateral Crowe type IV developmental dysplasia of the hip (DDH). The consistency between the proximal and distal segments was assessed as a possible predictive indicator of the union at the osteotomy site. METHODS: We retrospectively reviewed 57 patients with unilateral Crowe type IV DDH who underwent X-ray imaging of both hip joints. We labelled the inner and outer diameters of the circular ring as N (mm) and M (mm), respectively. We defined the overlapped area between the proximal and distal ring as contact area S (mm2), and the ratio of contact area to distal ring area as coincidence rate R. RESULTS: N varied from 9.8-15.2 mm and M varied from 20.7-24 mm, both demonstrated a decreasing trend in the proximal to distal direction. At osteotomy lengths ranging from 0.5-2 cm, there were no differences in S between the different levels of osteotomy in each group. At osteotomy lengths ≤2.5 cm, a significant higher coincidence rate was noted from 2 cm below the lesser trochanter to other positions below the level. At osteotomy lengths from 3 to 5.5 cm, a significantly higher coincidence rate was observed from the level of 1.5 cm below the lesser trochanter to other positions below the level. CONCLUSIONS: Our findings suggest that femoral shortening transverse osteotomy at the optimal subtrochanteric level can predictably increase the contact area and coincidence rate, which may contribute to the union at the osteotomy site. Considering the stability of the prostheses, it appears appropriate that osteotomy location should be shifted slightly distally. TRIAL REGISTRATION: Retrospectively registered.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Luxación Congénita de la Cadera/cirugía , Osteotomía/métodos , Acetábulo/cirugía , Adulto , Anciano , Femenino , Humanos , Luxaciones Articulares , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Radiografía , Recuperación de la Función , Adulto Joven
18.
Mikrochim Acta ; 187(5): 269, 2020 04 14.
Artículo en Inglés | MEDLINE | ID: mdl-32291536

RESUMEN

A hydroxyl-functionalized homochiral porous organic cage (POC) was synthesized and characterized by FTIR, NMR, thermogravimetric analysis (TGA), MALDI-TOF-MS, and elemental analysis. The synthesized homochiral POC was used as stationary phase to prepare a capillary gas chromatography (GC) column by a static coating method. The fabricated column shows excellent selectivity not only for the separation of positional isomers but also for the resolution of various racemates. Thirty-nine racemates have been resolved on the column, including alcohols, diols, halohydrocarbons, epoxides, esters, lactones, ketones, ethers, and organic acids. Compared to the commercial ß-DEX 120 column and previously reported chiral POCs (CC3-R, CC9, and CC10)-coated columns, there are 11, 10, 24, and 15 tested racemates that cannot be resolved on ß-DEX 120 column, CC3-R column, CC9 column, and CC10 column, respectively. This reveals that the fabricated column has prominent complementarity or superior separation performance to these columns in enantioseparation. Besides, the fabricated column can achieve some enantioseparations which are not possible using all previously reported chiral POC-based columns. Some positional isomers (xylenes, dichlorobenzenes, dibromobenzenes, nitrochlorobenzenes, and nitrobromobenzenes) were also separated with high-resolution values. The column exhibits good repeatability, reproducibility, and stability. The relative standard deviation (RSD) values of retention times were 0.03-0.18%, 0.11-0.92%, and 2.1-6.6% for run-to-run (n = 5), day-to-day (n = 5), and column-to-column (n = 3), respectively. The experimental results demonstrate the great potential of POCs for practical application in GC. Graphical Abstract A hydroxyl-functionalized homochiral porous organic cage was used as stationary phase for gas chromatography separation of racemates and positional isomers. The resolution of racemates mainly depended on hydrogen bonding, π-interaction, host-guest inclusion, steric fit, etc., while separation of positional isomers by shape-selective guest binding.

19.
Chirality ; 31(12): 1053-1059, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31633239

RESUMEN

Chiral mesoporous silica (CMS) has attracted widespread attention because of some unique properties, such as high surface area, uniformly structured nanoscale cavities, and excellent chemical and thermal stability. In this work, we report the utilization of a CMS as the stationary phase for the separation of racemates in gas chromatography (GC). A CMS-coated capillary column was fabricated by a dynamic coating method. Eighteen racemates belonging to different classes of organic compounds were separated on this column, including chiral alcohols, aldehydes, ketones, organic acids, halohydrocarbons, alkenes, alcohol amines, epoxides, and amino acid derivatives. In addition, linear alkanes, alcohols, and aromatic hydrocarbons have also been resolved.

20.
Molecules ; 24(3)2019 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-30682770

RESUMEN

Porous organic cages (POCs) have attracted extensive attention due to their unique structures and tremendous application potential in numerous areas. In this study, an enantioselective potentiometric sensor composed of a polyvinyl chloride (PVC) membrane electrode modified with CC3-R POC material was used for the recognition of enantiomers of 2-amino-1-butanol. After optimisation, the developed sensor exhibited enantioselectivity toward S-2-amino-1-butanol ( log K S , R P o t = -0.98) with acceptable sensitivity, and a near-Nernstian response of 25.8 ± 0.3 mV/decade within a pH range of 6.0⁻9.0.


Asunto(s)
Amino Alcoholes/química , Técnicas Electroquímicas , Electrodos , Concentración de Iones de Hidrógeno , Membranas Artificiales , Estructura Molecular , Cloruro de Polivinilo/química , Porosidad , Potenciometría , Sensibilidad y Especificidad , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA