Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Digit Imaging ; 36(1): 204-230, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36323914

RESUMEN

Magnetic resonance imaging (MRI) provides excellent soft-tissue contrast for clinical diagnoses and research which underpin many recent breakthroughs in medicine and biology. The post-processing of reconstructed MR images is often automated for incorporation into MRI scanners by the manufacturers and increasingly plays a critical role in the final image quality for clinical reporting and interpretation. For image enhancement and correction, the post-processing steps include noise reduction, image artefact correction, and image resolution improvements. With the recent success of deep learning in many research fields, there is great potential to apply deep learning for MR image enhancement, and recent publications have demonstrated promising results. Motivated by the rapidly growing literature in this area, in this review paper, we provide a comprehensive overview of deep learning-based methods for post-processing MR images to enhance image quality and correct image artefacts. We aim to provide researchers in MRI or other research fields, including computer vision and image processing, a literature survey of deep learning approaches for MR image enhancement. We discuss the current limitations of the application of artificial intelligence in MRI and highlight possible directions for future developments. In the era of deep learning, we highlight the importance of a critical appraisal of the explanatory information provided and the generalizability of deep learning algorithms in medical imaging.


Asunto(s)
Aprendizaje Profundo , Humanos , Inteligencia Artificial , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Aumento de la Imagen
2.
Sci Rep ; 13(1): 21183, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-38040835

RESUMEN

Low-field portable magnetic resonance imaging (MRI) scanners are more accessible, cost-effective, sustainable with lower carbon emissions than superconducting high-field MRI scanners. However, the images produced have relatively poor image quality, lower signal-to-noise ratio, and limited spatial resolution. This study develops and investigates an image-to-image translation deep learning model, LoHiResGAN, to enhance the quality of low-field (64mT) MRI scans and generate synthetic high-field (3T) MRI scans. We employed a paired dataset comprising T1- and T2-weighted MRI sequences from the 64mT and 3T and compared the performance of the LoHiResGAN model with other state-of-the-art models, including GANs, CycleGAN, U-Net, and cGAN. Our proposed method demonstrates superior performance in terms of image quality metrics, such as normalized root-mean-squared error, structural similarity index measure, peak signal-to-noise ratio, and perception-based image quality evaluator. Additionally, we evaluated the accuracy of brain morphometry measurements for 33 brain regions across the original 3T, 64mT, and synthetic 3T images. The results indicate that the synthetic 3T images created using our proposed LoHiResGAN model significantly improve the image quality of low-field MRI data compared to other methods (GANs, CycleGAN, U-Net, cGAN) and provide more consistent brain morphometry measurements across various brain regions in reference to 3T. Synthetic images generated by our method demonstrated high quality both quantitatively and qualitatively. However, additional research, involving diverse datasets and clinical validation, is necessary to fully understand its applicability for clinical diagnostics, especially in settings where high-field MRI scanners are less accessible.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Relación Señal-Ruido , Benchmarking , Carbono , Procesamiento de Imagen Asistido por Computador/métodos
3.
Neuroinformatics ; 20(4): 1105-1120, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35731372

RESUMEN

Parcellation of whole brain tractograms is a critical step to study brain white matter structures and connectivity patterns. The existing methods based on supervised classification of streamlines into predefined streamline bundle types are not designed to explore sub-bundle structures, and methods with manually designed features are expensive to compute streamline-wise similarities. To resolve these issues, we propose a novel atlas-free method that learns a latent space using a deep recurrent auto-encoder trained in an unsupervised manner. The method efficiently embeds any length of streamlines to fixed-size feature vectors, named streamline embedding, for tractogram parcellation using non-parametric clustering in the latent space. The method was evaluated on the ISMRM 2015 tractography challenge dataset with discrimination of major bundles using clustering algorithms and streamline querying based on similarity, as well as real tractograms of 102 subjects Human Connectome Project. The learnt latent streamline and bundle representations open the possibility of quantitative studies of arbitrary granularity of sub-bundle structures using generic data mining techniques.


Asunto(s)
Conectoma , Sustancia Blanca , Humanos , Sustancia Blanca/diagnóstico por imagen , Imagen de Difusión Tensora/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Conectoma/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen
4.
Gigascience ; 112022 04 30.
Artículo en Inglés | MEDLINE | ID: mdl-35488859

RESUMEN

BACKGROUND: "Functional" [18F]-fluorodeoxyglucose positron emission tomography (FDG-fPET) is a new approach for measuring glucose uptake in the human brain. The goal of FDG-fPET is to maintain a constant plasma supply of radioactive FDG in order to track, with high temporal resolution, the dynamic uptake of glucose during neuronal activity that occurs in response to a task or at rest. FDG-fPET has most often been applied in simultaneous BOLD-fMRI/FDG-fPET (blood oxygenation level-dependent functional MRI fluorodeoxyglucose functional positron emission tomography) imaging. BOLD-fMRI/FDG-fPET provides the capability to image the 2 primary sources of energetic dynamics in the brain, the cerebrovascular haemodynamic response and cerebral glucose uptake. FINDINGS: In this Data Note, we describe an open access dataset, Monash DaCRA fPET-fMRI, which contrasts 3 radiotracer administration protocols for FDG-fPET: bolus, constant infusion, and hybrid bolus/infusion. Participants (n = 5 in each group) were randomly assigned to each radiotracer administration protocol and underwent simultaneous BOLD-fMRI/FDG-fPET scanning while viewing a flickering checkerboard. The bolus group received the full FDG dose in a standard bolus administration, the infusion group received the full FDG dose as a slow infusion over the duration of the scan, and the bolus-infusion group received 50% of the FDG dose as bolus and 50% as constant infusion. We validate the dataset by contrasting plasma radioactivity, grey matter mean uptake, and task-related activity in the visual cortex. CONCLUSIONS: The Monash DaCRA fPET-fMRI dataset provides significant reuse value for researchers interested in the comparison of signal dynamics in fPET, and its relationship with fMRI task-evoked activity.


Asunto(s)
Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Glucosa , Humanos , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos
5.
Sci Data ; 8(1): 267, 2021 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-34654823

RESUMEN

Understanding how the living human brain functions requires sophisticated in vivo neuroimaging technologies to characterise the complexity of neuroanatomy, neural function, and brain metabolism. Fluorodeoxyglucose positron emission tomography (FDG-PET) studies of human brain function have historically been limited in their capacity to measure dynamic neural activity. Simultaneous [18 F]-FDG-PET and functional magnetic resonance imaging (fMRI) with FDG infusion protocols enable examination of dynamic changes in cerebral glucose metabolism simultaneously with dynamic changes in blood oxygenation. The Monash vis-fPET-fMRI dataset is a simultaneously acquired FDG-fPET/BOLD-fMRI dataset acquired from n = 10 healthy adults (18-49 yrs) whilst they viewed a flickering checkerboard task. The dataset contains both raw (unprocessed) images and source data organized according to the BIDS specification. The source data includes PET listmode, normalization, sinogram and physiology data. Here, the technical feasibility of using opensource frameworks to reconstruct the PET listmode data is demonstrated. The dataset has significant re-use value for the development of new processing pipelines, signal optimisation methods, and to formulate new hypotheses concerning the relationship between neuronal glucose uptake and cerebral haemodynamics.


Asunto(s)
Neuroimagen Funcional , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Corteza Visual/diagnóstico por imagen , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Corteza Visual/metabolismo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA