Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 103(7): 1093-1100, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38690931

RESUMEN

BACKGROUND: As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates. AIMS: The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR. METHODS: PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups. RESULTS: The total patients' mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was -1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively. CONCLUSIONS: TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Estudios Retrospectivos , Factores de Tiempo , Factores de Riesgo , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Hemodinámica
2.
Catheter Cardiovasc Interv ; 103(2): 359-366, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38054354

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) with the self-expandable Venus P-valve system is a promising treatment for patients with pulmonary regurgitation (PR) and a native right ventricular outflow tract (RVOT). However, limited data is available regarding its midterm outcomes. This study assessed the midterm clinical and echocardiographic outcomes following Venus P-valve implantation. METHODS: From 2013 to 2018, 55 patients with moderate or severe PR after surgical RVOT repair with a transannular or RVOT patch were consecutively enrolled from six hospitals in China. Five-year clinical and echocardiographic outcomes were collected and evaluated. The primary endpoint was a freedom from all-cause mortality and reintervention. RESULTS: At 5 years, the primary endpoint was met for 96% of patients, corresponding to a freedom from all-cause mortality of 96% (95% confidence interval [CI]: 86%-99%) and freedom from reintervention of 98% (95% CI: 87%-100%). Endocarditis was reported in five patients (four patients within 1 year and one patient at 5 years) following PPVI. Transpulmonary gradient and stent orifice diameter remained stable compared to at discharge (p>0.05). No paravalvular leak was reported while only 1 patient gradually increased to moderate PR during follow-up. Significant improvement of RV diameter and LVEF (p<0.001) sustained over the 5-year follow-up, in consistent with remarked improved New York Heart Association(NYHA) functional class (p<0.001). CONCLUSION: The 5-year results of the China VenusP Study demonstrated the midterm benefits of Venus P-valve implantation in the management of patients with severe PR with an enlarged native RVOT by providing sustained symptomatic and hemodynamic improvement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Obstrucción del Flujo Ventricular Externo , Humanos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía
3.
Artículo en Inglés | MEDLINE | ID: mdl-38841867

RESUMEN

OBJECTIVES: The clinical efficacy and safety of a novel left atrial appendage (LAA) occluder of the SeaLA closure system in patients with nonvalvular atrial fibrillation (NVAF) were reported. BACKGROUND: Patients with NVAF are at a higher risk of stroke compared to healthy individuals. Left atrial appendage closure (LAAC) has emerged as a prominent strategy for reducing the risk of thrombosis in individuals with NVAF. METHODS: A prospective, multicenter study was conducted in NVAF patients with a high risk of stroke. RESULTS: The LAAC was successfully performed in 163 patients. The mean age was 66.93 ± 7.92 years, with a mean preoperative CHA2DS2-VASc score of 4.17 ± 1.48. One patient with residual flow >3 mm was observed at the 6-month follow-up, confirmed by TEE. During the follow-up, 2 severe pericardiac effusions were noted, and 2 ischemic strokes were observed. Four device-related thromboses were resolved after anticoagulation treatment. There was no device embolism. CONCLUSIONS: The LAAC with the SeaLA device demonstrates encouraging feasibility, safety, and efficacy outcomes.

4.
Catheter Cardiovasc Interv ; 103(4): 660-669, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38419402

RESUMEN

Transcatheter pulmonary valve replacement (TPVR), also known as percutaneous pulmonary valve implantation, refers to a minimally invasive technique that replaces the pulmonary valve by delivering an artificial pulmonary prosthesis through a catheter into the diseased pulmonary valve under the guidance of X-ray and/or echocardiogram while the heart is still beating not arrested. In recent years, TPVR has achieved remarkable progress in device development, evidence-based medicine proof and clinical experience. To update the knowledge of TPVR in a timely fashion, and according to the latest research and further facilitate the standardized and healthy development of TPVR in Asia, we have updated this consensus statement. After systematical review of the relevant literature with an in-depth analysis of eight main issues, we finally established eight core viewpoints, including indication recommendation, device selection, perioperative evaluation, procedure precautions, and prevention and treatment of complications.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Pulmonar , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Resultado del Tratamiento , Asia , Catéteres
5.
Eur Radiol ; 2024 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-38308681

RESUMEN

OBJECTIVES: The study aimed to investigate the prognostic value of pre-transcatheter aortic valve replacement (TAVR) computed tomography angiography (CTA) in assessing physiological stenosis severity (CTA-derived fractional flow reserve (CT-FFR)) and high-risk plaque characteristics (HRPC). MATERIALS AND METHODS: Among TAVR patients who underwent pre-procedure CTA, the presence and number of HRPCs (minimum lumen area of < 4 mm2, plaque burden ≥ 70%, low-attenuating plaques, positive remodeling, napkin-ring sign, or spotty calcification) as well as CT-FFR were assessed. The risk of vessel-oriented composite outcome (VOCO, a composite of vessel-related ischemia-driven revascularization, vessel-related myocardial infarction, or cardiac death) was compared according to the number of HRPC and CT-FFR categories. RESULTS: Four hundred and twenty-seven patients (68.4% were male) with 1072 vessels were included. Their mean age was 70.6 ± 10.6 years. Vessels with low CT-FFR (≤ 0.80) (41.7% vs. 15.8%, adjusted hazard ratio (HRadj) 1.96; 95% confidence interval (CI): 1.28-2.96; p = 0.001) or lesions with ≥ 3 HRPC (38.7% vs. 16.0%, HRadj 1.81; 95%CI 1.20-2.71; p = 0.005) demonstrated higher VOCO risk. In the CT-FFR (> 0.80) group, lesions with ≥ 3 HRPC showed a significantly higher risk of VOCO than those with < 3 HRPC (34.7% vs. 13.0%; HRadj 2.04; 95%CI 1.18-3.52; p = 0.011). However, this relative increase in risk was not observed in vessels with positive CT-FFR (≤ 0.80). CONCLUSIONS: In TAVR candidates, both CT-FFR and the presence of ≥ 3 HRPC were associated with an increased risk of adverse clinical events. However, the value of HRPC differed with the CT-FFR category, with more incremental predictability among vessels with negative CT-FFR but not among vessels with positive CT-FFR. CLINICAL RELEVANCE STATEMENT: In transcatheter aortic valve replacement (TAVR) candidates, pre-TAVR CTA provided the opportunity to assess coronary physiological stenosis severity and high-risk plaque characteristics, both of which are associated with worse clinical outcomes. KEY POINTS: • The current study investigated the prognostic value of coronary physiology significance and plaque characteristics in transcatheter aortic valve replacement patients. • The combination of coronary plaque vulnerability and physiological significance showed improved accuracy in predicting clinical outcomes in transcatheter aortic valve replacement patients. • Pre-transcatheter aortic valve replacement CT can be a one-stop-shop tool for coronary assessments in clinical practice.

6.
Cardiology ; : 1-8, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38626740

RESUMEN

INTRODUCTION: Atrial septal defect (ASD) is one of the most common congenital heart malformations. Although not recommended, a significant proportion of patients with aortic root defects receive ASD closure, some of whom have improved right ventricular function. The study aimed to investigate the safety of interventional therapy in ASD patients with complete aortic rim deficiency and explore the predictors of right atrial (RA) non-reverse remodeling. METHODS: 1,011 patients with ASD who underwent transcatheter closure in the Department of Cardiology, Zhongshan Hospital, affiliated to Fudan University from June 2017 to June 2023 were enrolled in the study. They were divided into a complete aortic rim deficiency group and without absent aortic rim group. Furthermore, patients who had an enlarged RA in the absent aortic rim group were divided into two subgroups according to whether their RA remodeling was reversed post-procedure. Multivariate logistic regression was used to determine the predictors of RA reverse remodeling. RESULTS: During the 1-year follow-up, no major operative complications occurred in all patients with the absence of an aortic rim and a normal edge. After the operation, the right heart remodeling was significantly reversed, multivariate logistic regression analysis was performed, and it was found that no coronary heart disease before an operation, lower plasma creatinine level, and larger RA and RV dimensions were the predictive factors for the reverse of RA remodeling after treatment. CONCLUSION: Transcatheter closure of ASD with complete aortic rim deficiency is safe and feasible. For patients without coronary heart disease, the lower the creatinine value and the lower the tricuspid regurgitation before an operation, the more improvement of RA remodeling after the operation.

8.
Crit Rev Eukaryot Gene Expr ; 33(7): 81-90, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37602455

RESUMEN

The development and progression of atherosclerosis represent a chronic process involving complex molecular interactions. Therefore, identifying the potential hub genes and pathways contributing to coronary artery disease (CAD) development is essential for understanding its underlying molecular mechanisms. To this end, we performed transcriptome analysis of peripheral venous blood collected from 100 patients who were divided into four groups according to disease severity, including 27 patients in the atherosclerosis group, 22 patients in the stable angina group, 35 patients in the acute myocardial infarction group, and 16 controls. Weighted gene co-expression network analysis was performed using R programming. Significant module-trait correlations were identified according to module membership and genetic significance. Metascape was used for the functional enrichment of differentially expressed genes between groups, and the hub genes were identified via protein-protein interaction network analysis. The hub genes were further validated by analyzing Gene Expression Omnibus (GSE48060 and GSE141512) datasets. A total of 9,633 messenger ribonucleic acids were detected in three modules, among which the blue module was highly correlated with the Gensini score. The hub genes were significantly enriched in the myeloid leukocyte activation pathway, suggesting its important role in the progression of atherosclerosis. Among these genes, the Mediterranean fever gene (MEFV) may play a key role in the progression of atherosclerosis and CAD severity.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Humanos , Enfermedad de la Arteria Coronaria/genética , Redes Reguladoras de Genes , Aterosclerosis/genética , Mapas de Interacción de Proteínas/genética , Pirina
9.
Hum Genomics ; 16(1): 36, 2022 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-36071494

RESUMEN

Bicuspid aortic valve (BAV) is the most common congenital heart defect in human beings, with an estimated prevalence in the general population of between 0.5 and 2%. Moreover, BAV is the most common cause of aortic stenosis in the pediatric population. Patients with BAV may have no symptoms for life, and some of them may progress to aortic stenosis. Genetic factors increase the susceptibility and development of BAV. However, the pathogenesis and BAV are still unclear, and more genetic variants are still needed for elucidating the molecular mechanism and stratification of patients. The present study carried out screening of variants implicated in disease in BAV patients. The whole-exome sequencing (WES) was performed in 20 BAV patients and identified 40 different heterozygous missense mutations in 36 genes (MIB2, FAAH, S100A1, RGS16, MAP3K19, NEB, TTN, TNS1, CAND2, CCK, KALRN, ATP10D, SLIT3, ROS1, FABP7, NUP205, IL11RA, NPR2, COL5A1, CUBN, JMJD1C, ANXA7, TRIM8, LGR4, TPCN2, APOA5, GPR84, LRP1, NCOR2, AKAP11, ESRRB, NGB, AKAP13, WWOX, KCNJ12, ARHGEF1). The mutations in these genes were identified as recurrent variants implicated in disease by in silico prediction tool analysis. Nine genes (MIB2, S100A1, TTN, CCK, NUP205, LGR4, NCOR2, ESRRB, and WWOX) among the 36 genes were identified as variants implicated in disease via unanimous agreement of in silico prediction tool analysis and sequenced in an independent cohort of 137 BAV patients to validate the results of WES. BAV patients carrying these variants demonstrated reduced left ventricular ejection fractions (LVEF) (63.8 ± 7.5% vs. 58.4 ± 5.2%, P < 0.001) and larger calcification volume [(1129.3 ± 154) mm3 vs. (1261.8 ± 123) mm3, P < 0.001]. The variants in TTN, NUP205 and NCOR2 genes are significantly associated with reduced LVEF, and the variants in S100A1, LGR4, ESRRB, and WWOX genes are significantly associated with larger calcification volume. We identified a panel of recurrent variants implicated in disease in genes related to the pathogenesis of BAV. Our data speculate that these variants are promising markers for risk stratification of BAV patients with increased susceptibility to aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Válvula Aórtica/anomalías , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/patología , Proteínas Portadoras/genética , Niño , Enfermedades de las Válvulas Cardíacas/genética , Enfermedades de las Válvulas Cardíacas/patología , Humanos , Histona Demetilasas con Dominio de Jumonji , Quinasas Quinasa Quinasa PAM/genética , Proteínas del Tejido Nervioso/genética , Oxidorreductasas N-Desmetilantes , Proteínas Tirosina Quinasas/genética , Proteínas Proto-Oncogénicas/genética , Ubiquitina-Proteína Ligasas , Secuenciación del Exoma
10.
Catheter Cardiovasc Interv ; 102(2): 301-309, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37471710

RESUMEN

BACKGROUND: The ValveClasp system is a novel transcatheter edge-to-edge repair (TEER) device with an arm-width-expandable clip that allows treatment of patients with only one clip more frequently. OBJECTIVES: This study aimed to evaluate the feasibility and safety of a novel TEER device in porcine models and patients. METHODS: Fourteen young adult pigs were enrolled. A clip with an expanded arm was implanted under epicardial echocardiography and fluoroscopy guidance. Five patients with at least moderate-to-severe mitral regurgitation underwent TEER using the ValveClasp system to test the safety and effectiveness of the device. RESULTS: The device success rate was 100% (14/14) in the animal experiments, and all clips were deployed at the A2P2 segments, forming a double-orifice mitral valve. Gross observations on day 180 showed a wide and continuous tissue bridge between the leaflets. The acute procedural success rate was 100% (5/5). Only one clip was required in all patients, and all achieved effective postoperative endpoints (grade ≤2+). During 30-day follow-up, no adverse events occurred. All patients' vena Contracta width (from 8.04 0.71 mm to 3.84 ± 1.18 mm, p = 0.012), mitral regurgitation area (from 12.75 ± 3.13 cm2 to 3.50 ± 1.66 cm2 , p = 0.008), and left ventricular end diastolic diameter (from 52.00 ± 2.92 mm to 46.00 ± 3.08 mm, p = 0.040) were considerably decreased, without obvious mitral stenosis. CONCLUSIONS: The novel arm-width-expandable ValveClasp device is safe for TEER for treating severe mitral regurgitation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Animales , Humanos , Cateterismo Cardíaco/efectos adversos , Ecocardiografía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Porcinos , Resultado del Tratamiento
11.
Surg Today ; 53(1): 90-97, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36088621

RESUMEN

PURPOSE: The ValveClamp system is a novel edge-to-edge mitral valve repair system designed for the ease of operation. We report the outcomes of our initial experience of treating functional mitral regurgitation (MR) with the ValveClamp system. METHODS: The subjects of this study were patients with symptomatic functional MR despite standard medical therapy, who were treated with transapical ValveClamp implantation. The patients were divided into an atrial functional mitral regurgitation (AFMR) group and a ventricular functional mitral regurgitation (VFMR) group. Clinical and echocardiographic outcomes were evaluated at baseline and then at the 3-month follow up. RESULTS: Twelve patients, with a median age of 71 years (range 65-78 years), were assigned to the AFMR group (n = 5) or the VFMR group (n = 7). The device implantation rate was 100%, and 10 (83.3%) patients required implantation of only one clamp. The catheter time was less than 10 min in half of the patients, the fastest time being 5 min. There were no procedure-related complications. At the 3-month follow up, all patients were free from all-cause mortality, surgery, and rehospitalization. MR improved to ≤ 2 + in all 12 patients with MR grade 3 + or 4 + at baseline, (100%) and to ≤ 1 + in 9 of these patients (75%), with a low-pressure gradient. The left atrial diameter and the left ventricular end diastolic diameter decreased significantly in both the AFMR and VFMR groups. The left ventricular eject fraction at the 3-month follow up showed a rising trend in both the AFMR and VFMR groups, whereas PASP decreased remarkably. All 12 patients with baseline NYHA functional class III/IV (100%) showed improvement of at least 1 class, and 2 of these patients (16.7%) showed improvement of at least 2 classes. CONCLUSIONS: The ValveClamp system is simple and effective for transapical transcatheter edge to edge repair in patients with functional MR.


Asunto(s)
Fibrilación Atrial , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Anciano , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Catéteres/efectos adversos
12.
Catheter Cardiovasc Interv ; 99(7): 2113-2116, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35419838

RESUMEN

Percutaneous balloon mitral valvuloplasty (PBMV) is not traditionally suitable for patients with mitral stenosis (MS) and left atrium (LA) thrombus. Moreover, PBMV cannot be performed in patients with LA thrombus not resolving after anti-coagulation treatment. Here we present a case of PBMV using a novel technique employing both a veno-arterial loop and neuro-embolic protection, in a patient with MS and LA thrombus resistant to warfarin therapy. The patient successfully underwent PBMV without any complications.


Asunto(s)
Valvuloplastia con Balón , Procedimientos Quirúrgicos Cardíacos , Embolia , Estenosis de la Válvula Mitral , Trombosis , Valvuloplastia con Balón/métodos , Humanos , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/terapia , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/terapia , Resultado del Tratamiento
13.
BMC Cardiovasc Disord ; 22(1): 540, 2022 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-36503424

RESUMEN

BACKGROUND: There is a lack of available data on specific prognostic comparisons between transcatheter aortic valve replacement (TAVR) using self-expandable valves (SEV) in patients with stenotic Type 0, Type 1 bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). OBJECTIVES: To evaluate the association between aortic valve morphology and outcomes following self-expandable TAVR. METHODS: Consecutive patients with aortic stenosis(AS) undergoing self-expandable TAVR were enrolled and categorized into three groups (Type 0/Type 1 BAV or TAV) according to the Sievers classification. The primary endpoint was a composite of all-cause mortality and rehospitalization for heart failure (HF) within 2 years. Secondary outcomes included procedural complications and major cardiovascular events observed in clinical follow-ups. Clinical outcomes at 2 years following TAVR were compared among three groups using Kaplan-Meier curve and multivariable Cox proportional hazards regression models. RESULTS: A total of 344 AS patients (Type 0: 86; Type 1: 109; TAV: 149) were enrolled. The presence of moderate or severe paravalvular leak (PVL) was significantly higher in patients with Type 0 and Type 1 BAV versus TAV (10.47% vs. 16.51% vs. 6.71%, p = 0.043). All-cause 30-day mortality (2.33% vs. 0.92% vs. 2.68%, p = 0.626) and 2-year mortality (3.49% vs. 5.50% vs. 6.71%, p = 0.657) was comparable among the three groups. However, rehospitalization for HF within 2 years was significantly higher in Type 1 BAV (11.63% vs. 20.18% vs. 8.72%, p = 0.020). Multivariate Cox analysis showed that a higher STS score, Type 1 BAV morphology and excess leaflet calcification (≥ median calcium volume (CV) of the entire population) were independent predictors for HF rehospitalization. Additional intragroup Kaplan‒Meier analysis showed that excess leaflet calcification could predict higher long-term mortality and rehospitalization risk for HF(HR (95% CI): 3.430 (1.166-10.090), log rank p = 0.017) in Type 1 BAV patients. CONCLUSION: Outcomes of self-expandable TAVR in BAV-AS patients might vary depending on valve subtypes. BAV patients with excess leaflet calcification and a raphe, especially calcified, had an increased risk of moderate PVL and HF readmission in mid-to-long term follow-ups.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis , Enfermedades de las Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Enfermedades de las Válvulas Cardíacas/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Calcinosis/cirugía
14.
J Thromb Thrombolysis ; 54(1): 123-131, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35279783

RESUMEN

The current study aimed to elucidate the efficacy of interatrial shunt device (IASD) for the treatment of acute pulmonary hypertensive crisis (PHC) and chronic pulmonary arterial hypertension (PAH). After establishing chronic PAH models using dehydrogenized monocrotaline (DHMCT), PAH dogs were implanted with IASDs (group A) or received no intervention (group B). One month later, DHMCT was injected again to establish an acute PHC. The prognosis, hemodynamics, ultrasound cardiography, electrocardiogram, and lung pathology of the dogs were observed. The baseline mean pulmonary arterial pressure increased from 12.70 ± 1.03 to 19.95 ± 1.75 mmHg and established a chronic PAH model 2 months after DHMCT injection (1.50 mg/kg). After an additional injection of DHMCT (1.50 mg/kg) in the chronic PAH model, acute PHC occurred. Mean PAP, sPAP, and pulmonary vascular resistance increased to 22.67 ± 1.80 mmHg, 35.70 ± 1.66 mmHg, and 12.50 ± 3.50 WOOD U, respectively. Cardiac output (CO) decreased to 1.31 ± 0.26 L/min, and the right-to-left shunt caused hypoxemia. The survival rates of the dogs with and those without IASD were 70.0% and 22.2% (P = 0.037), respectively. Six months after PHC, the CO between the dogs with and those without IASD were 1.44 ± 0.11 L/min and 1.18 ± 0.04 L/min (P = 0.028). The long-term survival rates were 50.0% and 22.2%, respectively (P = 0.21). IASD might be efficacious and beneficial for treating acute PHC and chronic PAH, as well as improving prognosis.


Asunto(s)
Hipertensión Pulmonar , Hipertensión Arterial Pulmonar , Animales , Perros , Hemodinámica , Pulmón , Monocrotalina
15.
Respirology ; 27(7): 517-528, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35293069

RESUMEN

BACKGROUND AND OBJECTIVE: Nationally representative reports on the characteristics and long-term survival of pulmonary arterial hypertension (PAH) from developing countries are scarce. The applicability of the current main risk stratifications and the longitudinal changes in goal-oriented treatments have yet to be elucidated in real-world settings. Therefore, we aimed to provide insights into the characteristics, goal-oriented treatments and survival of PAH in China and to explore the applicability of the main risk stratifications in our independent cohort. METHODS: PAH patients were consecutively enrolled from a national prospective multicentre registry. Data on baseline, follow-up re-evaluation and therapeutic changes were collected. RESULTS: A total of 2031 patients were enrolled, with congenital heart disease (CHD)-PAH (45.2%) being the most common aetiology. The mean age was 35 ± 12 years, and 76.2% were females. At baseline, approximately 20% of the patients with intermediate or high risk received combination treatment. At follow-up, approximately half of the re-evaluated patients did not achieve low-risk profiles, and even among patients who received combination therapy at baseline, 4% of them still worsened. The rate of combination therapy increased significantly from 6.7% before 2015 to 35.5% thereafter. The main risk assessment tools demonstrated good performance for predicting survival both at baseline and at follow-up. CONCLUSION: Chinese PAH patients show both similar and distinct features compared to other countries. Current main risk stratifications can significantly discriminate patients at different risk levels. There were still many patients not achieving low-risk profiles at follow-up, indicating more aggressive treatment should be implemented to optimize the goal-oriented treatment strategy.


Asunto(s)
Cardiopatías Congénitas , Hipertensión Arterial Pulmonar , Adulto , Hipertensión Pulmonar Primaria Familiar , Femenino , Objetivos , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Adulto Joven
16.
Int Heart J ; 63(1): 23-29, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35095072

RESUMEN

The ValveClamp system is a novel edge-to-edge mitral valve repair system that is designed for ease of operation. We aimed to report the 1-year outcomes of the early feasibility study of this system.Patients with severe degenerative mitral regurgitation (MR) at higher surgical risk and who received transapical ValveClamp implantation were followed for 1 year for clinical and echocardiographic outcomes.Twelve patients (mean age, 76.5 ± 6.3 years; mean Society of Thoracic Surgery score, 6.9 ± 1.9%) were enrolled at three sites in China. At 1 year, no patient died, received reoperation, or had long-term complications. Of the 12 patients with MR of 3+ or 4+ at baseline, 11 patients (91.67%) remained with MR ≤ 2+ at 1 year, and no patient had mitral stenosis. Significant reductions in maximum MR area (from 15.1 ± 6.51 cm2 to 4.45 ± 1.85 cm2, P < 0.001), effective orifice area (from 4.34 ± 0.34 cm2 to 2.38 ± 0.45 cm2, P < 0.001), and vena contracta width (from 8.03 ± 1.11 to 3.38 ± 2.11 mm, P < 0.001) were observed. The left cardiac dimensions were decreased, especially the mitral valve annulus diameter (from 34.79 ± 4.27 mm to 31.42 ± 2.81 mm, P < 0.05). Of the 12 patients with baseline New York Heart Association functional class III/IV, all patients experienced an improvement of at least one class (P < 0.05).Our study provides evidence that transapical ValveClamp implantation in high-risk patients with severe degenerative MR is safe and feasible, with good efficacy in the mid-long term.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Insuficiencia de la Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco , Ecocardiografía , Estudios de Factibilidad , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 97(1): 177-185, 2021 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-32497395

RESUMEN

OBJECTIVES: We sought to assess the acute intraprocedural effects of the ValveClamp system in DMR patients on the mitral valve (MV) three-dimensional (3D) geometry and the association of these effects with mitral regurgitation (MR) reduction. BACKGROUND: Few data are available about the specific impact of transcatheter edge-to-edge repair in patients with degenerative mitral regurgitation (DMR). METHODS: Thirty-five symptomatic patients (age 74.26 ± 6.61 years) with Grade 3 to 4+ degenerative MR underwent 3D transoesophageal echocardiography (TEE) during ValveClamp implantation. Volumetric data sets were retrospectively analyzed using mitral valve quantitative 3D modeling software. RESULTS: Mitral valve annular anterior-posterior (AP) diameter decreased from 33.24 ± 4.03 to 31.12 ± 3.66 mm (p < .001), and prolapse height from 4.78 ± 2.19 to 2.32 ± 1.92 mm (p < .001), and total exposed leaflet area from 1,110.29 ± 224.21 mm2 to 1,013.44 ± 228.71 mm (p = .004). Accordingly, we observed a significant reduction of MR severity after ValveClamp implantation. Multivariable analysis revealed postprocedural MR reduction was associated with shortening in anterior-posterior diameter (coefficient 0.427, p = .008) and reduction in prolapse height (coefficient 0.369, p = .021). CONCLUSIONS: ValveClamp implantation exerts an acute effect on the 3D MV geometry. Postprocedural reduction in AP diameter and reduction in prolapse height correlates with MR downgrading in patients with degenerative MR.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Anciano , Ecocardiografía Transesofágica , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
18.
J Interv Cardiol ; 2021: 6659261, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33976590

RESUMEN

MitraClip edge-to-edge (E2E) repair system is the only transcatheter device recommended in the current guidelines for treating mitral regurgitation (MR). The percutaneous femoral venous transseptal access of MitraClip requires a complex steerable delivery system and may thus be technically complex to optimally position and deploy the clip onto the mitral valve. A transapical approach for E2E repair has been devised to treat MR for the ease of operation (ValveClamp system, Hanyu Medical Technology, Shanghai). The first-in-human study of ValveClamp has demonstrated its early feasibility and effectiveness for the treatment of patients with degenerative MR. Transesophageal echocardiography (TEE) is the only imaging modality required for intraoperative guidance of ValveClamp implantation. Successful implantation depends on accurate localization and orientation of the clamp and efficient intraoperative communication between the echocardiographer and the intervention team. Thus, the focus of this review is on elaborating how two-dimensional (2D) and three-dimensional (3D) TEE are used in clinical practice to guide ValveClamp implantation and it may facilitate the understanding of simplicity and safety of this novel procedure. We also describe the implementation of several novel advancements in 3D TEE imaging, which improve the confidence of image interpretation for intraoperative guidance and expedite implantation times.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Mitral/cirugía , Cirugía Asistida por Computador/métodos , Ecocardiografía Tridimensional/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico
19.
Catheter Cardiovasc Interv ; 95(2): 332-338, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31020788

RESUMEN

OBJECTIVE: This study reports the 1-year clinical outcomes of the VitaFlow™ transcatheter aortic valve system in the treatment of severe aortic stenosis. BACKGROUND: The VitaFlow™ system (MicroPort®, Shanghai, China) was developed as a novel transcatheter aortic valve replacement system to mitigate or circumvent some of the challenges associated with heavily calcified valves and bicuspid valves. METHODS: From September 2014 to November 2017, a prospective, multicenter, single arm study was conducted in 11 centers in China. The primary end point was all cause mortality at 12 months. RESULTS: One hundred and ten symptomatic aortic stenosis patients (60 men, 50 women; mean age 77.73 ± 4.78 years) at prohibitive or high risk for surgery were enrolled. Mean society of thoracic surgeons score was 8.84 ± 5.58%. All-cause mortality was 2.7% at 1-year. Major stroke, major vascular complication, coronary artery obstruction, new pacemaker implantation occurred in 2.7, 2.7, 1.8, and 19.1% at 1-year follow-up, respectively. No patients had moderate or severe paravalvular leak at 1-year. At 1 year follow-up, 97% of patients had New York heart association ≤II. Patients with bicuspid valves had similar outcomes as those patients with tricuspid aortic valve stenosis. CONCLUSIONS: The 12-month clinical results support the safety and efficacy of VitaFlow™ in the treatment of patients with severe aortic stenosis, including patients with bicuspid aortic valve.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Válvula Aórtica/patología , Calcinosis/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , China , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/mortalidad , Enfermedades de las Válvulas Cardíacas/fisiopatología , Hemodinámica , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
20.
Echocardiography ; 37(11): 1828-1837, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33007129

RESUMEN

BACKGROUND: The aim of this study was to investigate the utility of perimeter-derived diameter (PDD) measured by three-dimensional (3D) transesophageal echocardiography (TEE) in predicting the size of left atrial appendage (LAA) occluder. METHODS AND RESULTS: Left atrial appendage landing zone diameter (LZD) was measured by two-dimensional (2D) TEE, 3DTEE, and digital subtraction angiography (DSA) as LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD, LZD-DSAmax, respectively, before and during transcatheter LAA closure with Watchman devices in 100 patients. A difference of one or more device size intervals between the predicted size and the size actually implanted was defined as mismatching. Seventy-eight patients were followed up by TEE to obtain occluder compression ratio. The correlation between LZD and the final implanted occluder size was 0.559, 0.641, 0.754, 0.760, 0.782, and 0.848 for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively (P < .001). Matching ratio between the size predicted by retrospective measurements of LZD and the device size actually implanted was 65%, 57%, 66%, 63%, 70%, and 83% for LZD-2Dmax, LZD-2Dmean, LZD-3Dmax, LZD-3Dmean, LZD-PDD and LZD-DSAmax, respectively. There was no significant difference in LZD value, matching ratio, and compression ratio between the patients with eccentric and noneccentric LAA landing zone (P > .05). Compression ratio of the mismatching subjects was higher than that in the matching subjects when evaluated by LZD-2Dmean, LZD-3Dmean, and LZD-PDD (P < .05). CONCLUSIONS: Landing zone diameter derived from LAA perimeter measured by preprocedure 3DTEE showed reference value for LAA occluder size selection, providing superior correlation and matching ratio with the final implanted size and indicating the adjustment of oversizing.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Tridimensional , Dispositivo Oclusor Septal , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Humanos , Valores de Referencia , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA