Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Br J Anaesth ; 133(3): 473-475, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39127482

RESUMEN

Out-of-hospital cardiac arrest (OHCA) is associated with very poor outcomes. Extracorporeal cardiopulmonary resuscitation (eCPR) for selected patients is a potential therapeutic option for refractory cardiac arrest. However, randomised controlled studies applying eCPR after refractory OHCA have demonstrated conflicting results regarding survival and good functional neurological outcomes. eCPR is an invasive, labour-intensive, and expensive therapeutic approach with associated side-effects. A rapid monitoring device would be valuable in facilitating selection of appropriate patients for this expensive and complex treatment. To this end, rapid diagnosis of hyperfibrinolysis, or premature clot dissolution, diagnosed by viscoelastic testing might represent a feasible option. Hyperfibrinolysis is an evolutionary response to low or no-flow states. Studies in trauma patients demonstrate a high mortality rate in those with established hyperfibrinolysis upon emergency room admission. Similar findings have now been reported for the first time in OHCA patients. Hyperfibrinolysis upon admission diagnosed by rotational thromboelastometry was strongly associated with mortality and poor neurological outcomes in a small cohort of patients treated with extracorporeal membrane oxygenation.


Asunto(s)
Reanimación Cardiopulmonar , Oxigenación por Membrana Extracorpórea , Fibrinólisis , Paro Cardíaco Extrahospitalario , Humanos , Oxigenación por Membrana Extracorpórea/métodos , Paro Cardíaco Extrahospitalario/terapia , Paro Cardíaco Extrahospitalario/mortalidad , Reanimación Cardiopulmonar/métodos , Tromboelastografía/métodos , Toma de Decisiones Clínicas/métodos , Inutilidad Médica
2.
Curr Opin Anaesthesiol ; 37(2): 131-138, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38390910

RESUMEN

PURPOSE OF REVIEW: Stress hyperglycaemia occur often in critically injured patients. To gain new consideration about it, this review compile current as well as known immunological and biochemical findings about causes and emergence. RECENT FINDINGS: Glucose is the preferred energy substrate for fending immune cells, reparative tissue and the cardiovascular system following trauma. To fulfil these energy needs, the liver is metabolically reprogrammed to rebuild glucose from lactate and glucogenic amino acids (hepatic insulin resistance) at the expenses of muscles mass and - to a less extent - fat tissue (proteolysis, lipolysis, peripheral insulin resistance). This inevitably leads to stress hyperglycaemia, which is evolutionary preserved and seems to be an essential and beneficial survival response. It is initiated by damage-associated molecular patterns (DAMPs) and pathogen-associated molecular patterns (PAMPs), intensified by immune cells itself and mainly ruled by tumour necrosis factor (TNF)α and catecholamines with lactate and hypoxia inducible factor (HIF)-1α as intracellular signals and lactate as an energy shuttle. Important biochemical mechanisms involved in this response are the Warburg effect as an efficient metabolic shortcut and the extended Cori cycle. SUMMARY: Stress hyperglycaemia is beneficial in an acute life-threatening situation, but further research is necessary, to prevent trauma patients from the detrimental effects of persisting hyperglycaemia.


Asunto(s)
Hiperglucemia , Resistencia a la Insulina , Humanos , Glucosa , Insulina , Lactatos
3.
ACS Omega ; 9(7): 8533-8542, 2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38405462

RESUMEN

Fibrinogen is a coagulation factor in human blood and the first one to reach critical levels in major bleeding. Hypofibrinogenemia (a too low fibrinogen concentration in blood) poses great challenges to first responders, clinicians, and healthcare providers since it represents a risk factor for exsanguination and massive transfusion requirements. Thus, the rapid assessment of the fibrinogen concentration at the point of care has gained considerable importance in preventing and managing major blood loss. However, in whole blood measurements, hematocrit variations affect the amount (volume fraction) of plasma that passes the detection zone. In an attempt to accurately determine realistic critical levels of fibrinogen (<1.5 mg/mL) in patients needing immediate treatment and medical interventions, we have developed novel diagnostic systems capable of estimating hematocrit and critical fibrinogen concentrations. A lateral flow assay (LFA) for the detection of fibrinogen has been developed by establishing a workflow employing rapid characterization methods to streamline LFA development. The integration of two detection lines enables (i) the identification of fibrinogen (first line) present in the sample and (ii) the determination of the clinically critical fibrinogen concentrations below 1.5 mg/mL (second line). Furthermore, the paper-based separation of blood cells from plasma provides a semiquantitative estimate of the hematocrit by analyzing the fractions. Initial validation of the point-of-care (PoC) hematocrit test revealed good comparability to a standard laboratory method. The developed diagnostic systems have the ability to accelerate decision-making in cases with major bleeding.

4.
J Clin Med ; 13(3)2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38337386

RESUMEN

Background: Viscoelastic hemostatic assays (VHAs) have become an integral diagnostic tool in guiding hemostatic therapy, offering new opportunities in personalized hemostatic resuscitation. This study aims to assess the interchangeability of ClotPro® and ROTEM® delta in the unique context of parturient women. Methods: Blood samples from 217 parturient women were collected at three timepoints. A total of 631 data sets were eligible for our final analysis. The clotting times were analyzed via extrinsic and intrinsic assays, and the clot firmness parameters A5, A10, and MCF were analyzed via extrinsic, intrinsic, and fibrin polymerization assays. In parallel, the standard laboratory coagulation statuses were obtained. Device comparison was assessed using regression and Bland-Altman plots. The best cutoff calculations were used to determine the VHA values corresponding to the established standard laboratory cutoffs. Results: The clotting times in the extrinsic and intrinsic assays showed notable differences between the devices, while the extrinsic and intrinsic clot firmness results demonstrated interchangeability. The fibrinogen assays revealed higher values in ClotPro® compared to ROTEM®. An ROC analysis identified VHA parameters with high predictive values for coagulopathy exclusion and yet low specificity. Conclusions: In the obstetric setting, the ROTEM® and ClotPro® parameters demonstrate a significant variability. Device- and indication-specific transfusion algorithms are essential for the accurate interpretation of measurements and adequate hemostatic therapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA