Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Sensors (Basel) ; 21(13)2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34209984

RESUMEN

Iodine is a trace chemical element fundamental for a healthy human organism. Iodine deficiency affects about 2 billion people worldwide causing from mild to severe neurological impairment, especially in children. Nevertheless, an adequate nutritional intake is considered the best approach to prevent such disorders. Iodine is present in seawater and seafood, and its common forms in the diet are iodide and iodate; most iodide in seawater is caused by the biological reduction of the thermodynamically stable iodate species. On this basis, a multisensor instrument which is able to perform a multidimensional assessment, evaluating iodide content in seawater and seafood (via an electrochemical sensor) and discriminating when the seafood is fresh or defrosted quality (via a Quartz Micro balance (QMB)-based volatile and gas sensor), is strategic for seafood quality assurance. Moreover, an electronic interface has been opportunely designed and simulated for a low-power portable release of the device, which should be able to identify seafood over or under an iodide threshold previously selected. The electrochemical sensor has been successfully calibrated in the range 10-640 µg/L, obtaining a root mean square error in cross validation (RMSECV) of only 1.6 µg/L. Fresh and defrosted samples of cod, sea bream and blue whiting fish have been correctly discriminated. This proof-of-concept work has demonstrated the feasibility of the proposed application which must be replicated in a real scenario.


Asunto(s)
Yoduros , Yodo , Animales , Niño , Humanos , Yodatos , Alimentos Marinos/análisis , Agua de Mar
2.
Sensors (Basel) ; 21(2)2021 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-33445599

RESUMEN

In this study, a novel approach was developed to quantify endocannabinoids (eCBs), and was based on the liquid biosensor BIONOTE. This device is composed of a probe that can be immersed in a solution, and an electronic interface that can record a current related to the oxy-reductive reactions occurring in the sample. The two most representative members of eCBs have been analysed in vitro by BIONOTE: anandamide (N-arachidonoylethanolamine, AEA) and 2-arachidonoylglycerol (2-AG). Bovine serum albumin was used to functionalize the probe and improve the sensibility of the whole analytical system. We show that BIONOTE is able to detect both AEA and 2-AG at concentrations in the low nanomolar range, and to discriminate between these eCBs and their moieties arachidonic acid, ethanolamine and glycerol. Notably, BIONOTE distinguished these five different molecules, and it was also able to quantify AEA in human plasma. Although this is just a proof-of-concept study, we suggest BIONOTE as a cheap and user-friendly prototype sensor for high throughput quantitation of eCB content in biological matrices, with an apparent diagnostic potential for tomorrow's medicine.


Asunto(s)
Técnicas Biosensibles/métodos , Endocannabinoides/análisis , Ácidos Araquidónicos/análisis , Ácidos Araquidónicos/sangre , Técnicas Biosensibles/instrumentación , Endocannabinoides/sangre , Glicéridos/análisis , Glicéridos/sangre , Humanos , Alcamidas Poliinsaturadas/análisis , Alcamidas Poliinsaturadas/sangre
3.
Sensors (Basel) ; 21(11)2021 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-34071694

RESUMEN

Cerebrospinal fluid (CSF) analysis supports diagnosis of neurodegenerative diseases (NDs), however a number of issues limits its potentialities in clinical practice. Here, a newly developed technique for fluid voltammetry, relying on a simple sensor (BIOsensor-based multisensorial system for mimicking Nose, Tongue and Eyes, BIONOTE), was used to test the applicability for CSF analysis. BIONOTE was initially calibrated on an artificial CSF-like solution and then applied on human CSF, either immediately after collection or after refrigerated storage. Following optimization, it was used to evaluate 11 CSF samples correlating the electrochemical dataset with CSF routine parameters and biomarkers of neurodegeneration. Multivariate data analysis was performed for model elaboration and calibration using principal component analysis and partial least squares discriminant analysis. BIONOTE presented a high capacity to predict both physiological and pathological constituents of artificial CSF. It differentiated distinct fresh human CSF samples well but lost accuracy after refrigerated storage. The electrochemical analysis-derived data correlated with either CSF routine cytochemical indexes or a biomarker of neurodegeneration. BIONOTE resulted as being a reliable system for electrochemical analysis of CSF. The CSF fingerprint provided by the sensor has shown itself to be sensitive to CSF modification, thus it is potentially representative of CSF alteration. This result opens the way to its testing in further study addressed at assessing the clinical relevance of the methodology. Because of its advantages due to the ease and rapidity of the methodology, a validation study is now required to translate the technique into clinical practice and improve diagnostic workup of NDs.


Asunto(s)
Técnicas Biosensibles , Enfermedades Neurodegenerativas , Biomarcadores , Análisis Discriminante , Humanos
4.
Sensors (Basel) ; 21(8)2021 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-33920787

RESUMEN

The use of wearable sensors for health monitoring is rapidly growing. Over the past decade, wearable technology has gained much attention from the tech industry for commercial reasons and the interest of researchers and clinicians for reasons related to its potential benefit on patients' health. Wearable devices use advanced and specialized sensors able to monitor not only activity parameters, such as heart rate or step count, but also physiological parameters, such as heart electrical activity or blood pressure. Electrocardiogram (ECG) monitoring is becoming one of the most attractive health-related features of modern smartwatches, and, because cardiovascular disease (CVD) is one of the leading causes of death globally, the use of a smartwatch to monitor patients could greatly impact the disease outcomes on health care systems. Commercial wearable devices are able to record just single-lead ECG using a couple of metallic contact dry electrodes. This kind of measurement can be used only for arrhythmia diagnosis. For the diagnosis of other cardiac disorders, additional ECG leads are required. In this study, we characterized an electronic interface to be used with multiple contactless capacitive electrodes in order to develop a wearable ECG device able to perform several lead measurements. We verified the ability of the electronic interface to amplify differential biopotentials and to reject common-mode signals produced by electromagnetic interference (EMI). We developed a portable device based on the studied electronic interface that represents a prototype system for further developments. We evaluated the performances of the developed device. The signal-to-noise ratio of the output signal is favorable, and all the features needed for a clinical evaluation (P waves, QRS complexes and T waves) are clearly readable.


Asunto(s)
Pierna , Dispositivos Electrónicos Vestibles , Arritmias Cardíacas , Electrocardiografía , Electrodos , Humanos
5.
Sensors (Basel) ; 20(3)2020 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-31991728

RESUMEN

In this work an array of chemical sensors for gas detection has been developed, starting with a commercial sensor platform developed by Microchip (GestIC), which is normally used to detect, trace, and classify hand movements in space. The system is based on electric field changes, and in this work, it has been used as mechanism revealing the adsorption of chemical species CO2 and O2. The system is composed of five electrodes, and their responses were obtained by interfacing the sensors with an acquisition board based on an ATMEGA 328 microprocessor (Atmel MEGA AVR microcontroller). A dedicated measurement chamber was designed and prototyped in acrylonitrile butadiene styrene (ABS) using an Ultimaker3 3D printer. The measurement cell size is 120 × 85 mm. Anthocyanins (red rose) were used as a sensing material in order to functionalize the sensor surface. The sensor was calibrated using different concentrations of oxygen and carbon dioxide, ranging from 5% to 25%, mixed with water vapor in the range from 50% to 90%. The sensor exhibits good repeatability for CO2 concentrations. To better understand the sensor response characteristics, sensitivity and resolution were calculated from the response curves at different working points. The sensitivity is in the order of magnitude of tens to hundreds of µV/% for CO2, and of µV/% in the case of O2. The resolution is in the range of 10-1%-10-3% for CO2, and it is around 10-1% for O2. The system could be specialized for different fields, for environmental, medical, and food applications.

6.
Sensors (Basel) ; 19(18)2019 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-31547403

RESUMEN

One of the basic needs of professional athletes is the real-time and non-invasive monitoring of their activities. The use of these kind of data is necessary to develop strategies for specific tailored training in order to improve performances. The sensor system presented in this work has the aim to adopt a novel approach for the monitoring of physiological parameters, and athletes' performances, during their training. The anaerobic threshold is herein identified with the monitoring of the lactate concentration and the respiratory parameters. The data collected by the sensor are used to build a model using a supervised method (based on the partial least squares method, PLS) to predict the values of the parameters of interest. The sensor is able to measure the lactate concentration from a sample of saliva and it can estimate a respiratory parameter, such as maximal oxygen consumption, maximal carbon dioxide production and respiratory rate from a sample of exhaled breath. The main advantages of the device are the low power; the wireless communication; and the non-invasive sampling method, which allow its use in a real context of sport practice.


Asunto(s)
Atletas , Ejercicio Físico , Ácido Láctico/análisis , Monitoreo Fisiológico/métodos , Pruebas Respiratorias , Ejercicio Físico/fisiología , Humanos , Análisis de los Mínimos Cuadrados , Monitoreo Fisiológico/estadística & datos numéricos , Consumo de Oxígeno/fisiología , Prueba de Estudio Conceptual , Saliva
7.
J Transl Med ; 16(1): 17, 2018 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-29370807

RESUMEN

BACKGROUND: Dipstick test is widely used to support the diagnosis of urinary tract infections (UTI). It is effective in ruling out UTI, but urine culture is needed for diagnosis confirmation. In this study we compared the accuracy of voltammetric analysis (VA) with that of DT to detect UTI (diagnosed using urine culture), and its usefulness as a second-stage test in people with positive DT. METHODS: 142 patients were enrolled with no exclusion criteria. VA was performed using the BIONOTE device. Partial Least Square Discrimination Analysis was used to predict UTI based on VA data; diagnostic performance was evaluated using sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively), positive and negative likelihood ratios (LR), accuracy, diagnostic odds ratio (DOR). RESULTS: Mean age was 76.6 years (SD 12.6), 57% were male. VA had a better overall performance respect to DT in detecting UTI with accuracy 81.7% vs 75.9%, specificity 90.8% vs 82.5%, PPV 75% vs 61.4%, positive LR 6.68 vs 3.5, DOR 17.7 vs 7.47; sensibility, NPV and negative LR of the two tests were similar. VA had an accuracy of 82.4% in discriminating bacterial from fungal infections. When added as a second-stage test, VA identified 9 of the 17 false positive patients, with a net specificity of 91.7%, sensitivity 54%, PPV 75% and NPV 81%. CONCLUSIONS: VA is a quick and easy method that may be used as a second stage after DT to reduce the number of urine culture and of inappropriate antibiotic prescriptions.


Asunto(s)
Técnicas Electroquímicas/métodos , Infecciones Urinarias/diagnóstico , Anciano , Femenino , Humanos , Masculino , Infecciones Urinarias/microbiología , Infecciones Urinarias/orina
8.
Liver Int ; 37(2): 242-250, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27496750

RESUMEN

BACKGROUND & AIMS: The spectrum of volatile organic compounds in the exhaled breath (breath-print, BP) has been shown to characterize patients with cirrhosis and with worse hepatic function. However, the association of different BPs with clinically relevant outcomes has not been described yet. Hence, we aimed to evaluate the association between BPs, mortality and hospitalization in cirrhotic patients and to compare it with that of the "classical" prognostic indices (Child-Pugh Classification [CPC] and MELD). METHODS: Eighty-nine cirrhotic patients (M/F 59/30, mean age 64.8 ± 11.3, CPC A/B/C 37/33/19) were recruited and followed up for a median time of 23 months. Clinical and biochemical data were collected. Breath collection and analysis were obtained through Pneumopipe® and BIONOTE e-nose respectively. RESULTS: Four different BP clusters (A, B, C, D) were identified. BP clusters A and D were associated with a significantly increased risk of mortality (HR 2.9, 95% confidence intervals [CI] 1.5-5.6) and hospitalization (HR 2.6, 95% CI 1.4-4.6), even in multiple adjusted models including CPC and MELD score (adjusted [a]HR 2.8, 95% CI 1.1-7.0 for mortality and aHR 2.2, 95% CI 1.1-4.2 for hospitalization). CPC C maintained the strongest association with both mortality (aHR 17.6, 95% CI 1.8-174.0) and hospitalization (aHR 12.4, 95% CI 2.0-75.8). CONCLUSIONS: This pilot study demonstrates that BP clusters are associated with significant clinical endpoints (mortality and hospitalization) even independently from "classical" prognostic indices. Even though further studies are warranted on this topic, our findings suggest that the e-nose may become an adjunctive aid to stratify the risk of adverse outcomes in cirrhotic patients.


Asunto(s)
Pruebas Respiratorias/instrumentación , Nariz Electrónica , Cirrosis Hepática/diagnóstico , Pruebas de Función Hepática/instrumentación , Anciano , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Medición de Riesgo , Índice de Severidad de la Enfermedad , Análisis de Supervivencia , Factores de Tiempo , Compuestos Orgánicos Volátiles/análisis
9.
Sensors (Basel) ; 17(11)2017 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-29143768

RESUMEN

The aim of this work is the development of a contactless capacitive sensory system for the detection of (Electrocardiographic) ECG-like signals. The acquisition approach is based on a capacitive coupling with the patient body performed by electrodes integrated in a front-end circuit. The proposed system is able to detect changes in the electric charge related to the heart activity. Due to the target signal weakness and to the presence of other undesired signals, suitable amplification stages and analogue filters are required. Simulated results allowed us to evaluate the effectiveness of the approach, whereas experimental measurements, recorded without contact to the skin, have validated the practical effectiveness of the proposed architecture. The system operates with a supply voltage of ±9 V with an overall power consumption of about 10 mW. The analogue output of the electronic interface is connected to an ATmega328 microcontroller implementing the A/D conversion and the data acquisition. The collected data can be displayed on any multimedia support for real-time tracking applications.


Asunto(s)
Electrocardiografía , Electrodos , Diseño de Equipo , Humanos , Procesamiento de Señales Asistido por Computador
10.
Sensors (Basel) ; 15(9): 21660-72, 2015 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-26404285

RESUMEN

Methods for the chemical and sensorial evaluation of olive oil are frequently changed and tuned to oppose the increasingly sophisticated frauds. Although a plethora of promising alternatives has been developed, chromatographic techniques remain the more reliable yet, even at the expense of their related execution time and costs. In perspective of a continuous increment in the number of the analyses as a result of the global market, more rapid and effective methods to guarantee the safety of the olive oil trade are required. In this study, a novel artificial sensorial system, based on gas and liquid analysis, has been employed to deal with olive oil genuineness and authenticity issues. Despite these sensors having been widely used in the field of food science, the innovative electronic interface of the device is able to provide a higher reproducibility and sensitivity of the analysis. The multi-parametric platform demonstrated the capability to evaluate the organoleptic properties of extra-virgin olive oils as well as to highlight the presence of adulterants at blending concentrations usually not detectable through other methods.


Asunto(s)
Técnicas Biosensibles/instrumentación , Contaminación de Alimentos/análisis , Aceite de Oliva/química , Análisis Discriminante , Análisis de los Mínimos Cuadrados
11.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38473033

RESUMEN

Ovarian cancer (OC) is the eighth most common cancer in women. Since screening programs do not exist, it is often diagnosed in advanced stages. Today, the detection of OC is based on clinical examination, transvaginal ultrasound (US), and serum biomarker (Carbohydrate Antigen 125 (CA 125) and Human Epididymis Protein 4 (HE4)) dosage, with a sensitivity of 88% and 95%, respectively, and a specificity of 84% for US and 76% for biomarkers. These methods are clearly not enough, and OC in its early stages is often missed. Many scientists have recently focused their attention on volatile organic compounds (VOCs). These are gaseous molecules, found in the breath, that could provide interesting information on several diseases, including solid tumors. To detect VOCs, an electronic nose was invented by a group of researchers. A similar device, the e-tongue, was later created to detect specific molecules in liquids. For the first time in the literature, we investigated the potential use of the electronic nose and the electronic tongue to detect ovarian cancer not just from breath but also from urine, blood, and plasma samples.

12.
J Thorac Oncol ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38762120

RESUMEN

INTRODUCTION: Electronic nose (E-nose) technology has reported excellent sensitivity and specificity in the setting of lung cancer screening. However, the performance of E-nose specifically for early-stage tumors remains unclear. Therefore, the aim of our study was to assess the diagnostic performance of E-nose technology in clinical stage I lung cancer. METHODS: This phase IIc trial (NCT04734145) included patients diagnosed with a single greater than or equal to 50% solid stage I nodule. Exhalates were prospectively collected from January 2020 to August 2023. Blinded bioengineers analyzed the exhalates, using E-nose technology to determine the probability of malignancy. Patients were stratified into three risk groups (low-risk, [<0.2]; moderate-risk, [≥0.2-0.7]; high-risk, [≥0.7]). The primary outcome was the diagnostic performance of E-nose versus histopathology (accuracy and F1 score). The secondary outcome was the clinical performance of the E-nose versus clinicoradiological prediction models. RESULTS: Based on the predefined cutoff (<0.20), E-nose agreed with histopathologic results in 86% of cases, achieving an F1 score of 92.5%, based on 86 true positives, two false negatives, and 12 false positives (n = 100). E-nose would refer fewer patients with malignant nodules to observation (low-risk: 2 versus 9 and 11, respectively; p = 0.028 and p = 0.011) than would the Swensen and Brock models and more patients with malignant nodules to treatment without biopsy (high-risk: 27 versus 19 and 6, respectively; p = 0.057 and p < 0.001). CONCLUSIONS: In the setting of clinical stage I lung cancer, E-nose agrees well with histopathology. Accordingly, E-nose technology can be used in addition to imaging or as part of a "multiomics" platform.

13.
J Alzheimers Dis ; 95(3): 1067-1075, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37638437

RESUMEN

BACKGROUND: Recent studies have shown that oxidative stress plays a relevant role in Alzheimer's disease (AD), and in the pathogenesis of vascular dementia (VaD). New diagnostic methods look for biological samples with non-invasive sampling methods. Among these, saliva shows an increase in oxidative stress products, thus a corresponding reduction in antioxidant products were found in dementia cases compared to healthy controls. Compounds identified in saliva include some hydrocarbons whose production has been related to the presence of reactive oxygen species. OBJECTIVE: The hypothesis is that the voltammetric analysis performed on saliva could be a useful test for diagnosing dementia, potentially discriminating between AD and VaD. METHODS: A single-center observational study was conducted on patients referred to the dementia clinic in the Neurology area and healthy controls recruited in the Orthopedics area of the Campus Bio-Medico Hospital in Rome. The study was aimed at evaluating the discriminative properties of salivary voltammetric analysis between healthy subjects and patients with dementia and, as a secondary outcome, between AD and VaD. A total of 69 subjects were enrolled, including 29 healthy controls, 20 patients with AD, and 20 patients with VaD. The degree of cognitive impairment was classified on the basis of the Mini-Mental State Examination score. RESULTS: The results obtained are promising, with an accuracy of 79.7%, a sensitivity of 82.5%, and a specificity of 75.8%, in the discrimination of dementia versus controls. CONCLUSIONS: The methods tested demonstrate to be relevant in the discrimination between dementia and controls. A confirmatory study is already running.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Demencia Vascular , Humanos , Saliva , Enfermedad de Alzheimer/diagnóstico , Demencia Vascular/diagnóstico , Estrés Oxidativo
14.
Micromachines (Basel) ; 13(9)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36144063

RESUMEN

The need for accurate information and the availability of novel tool and technological advances in agriculture have given rise to innovative autonomous systems. The aim is to monitor key parameters for optimal water and fertilizer management. A key issue in precision agriculture is the in situ monitoring of soil macronutrients. Here, a proof-of-concept study was conducted that tested two types of sensors capable of capturing both the electrochemical response of the soil and the electrical potential generated by the interaction between the soil and plants. These two sensors can be used to monitor large areas using a network approach, due to their small size and low power consumption. The voltammetric sensor (BIONOTE-L) proved to be able to characterize different soil samples. It was able, indeed, to provide a reproducible voltammetric fingerprint specific for each soil type, and to monitor the concentration of CaCl2 and NaCl in the soil. BIONOTE-L can be coupled to a device capable of capturing the energy produced by interactions between plants and soil. As a consequence, the functionality of the microsystem node when applied in a large-area monitoring network can be extended. Additional calibrations will be performed to fully characterize the instrument node, to implement the network, and to specialize it for a particular application in the field.

15.
Micromachines (Basel) ; 13(9)2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36144148

RESUMEN

A plant biological system is exposed to external influences. In general, each plant has its characteristics and needs with specific interaction mechanisms adapted to its survival. Interactions between systems can be examined and modeled as energy exchanges of mechanical, chemical or electrical variables. Thus, each specific interaction can be examined by triggering the system via a specific stimulus. The objective of this work was to study a specific stimulus (mechanical stimulation) as a driver of plants and their interaction with the environment. In particular, the experimental design concerns the setting up and testing of an automatic source of mechanical stimuli at different wavelengths, generated by an electromechanical transducer, to induce a micro-interaction in plants (or in parts of them) that produces a specific behavior (hypothesis) of plants. Four different experimental setups were developed for this work, each pursuing the same objective: the analysis of the germination process induced by stimulation by sound waves in the audible range. It can be said that the introduction of sound waves as a stimulant or a brake for the growth of plants can offer significant advantages when used on a large scale in the primary sector, since these effects can be used instead of polluting chemical solutions.

16.
Front Med (Lausanne) ; 8: 655474, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34350192

RESUMEN

Background: Intestinal dysbiosis might play a pathogenetic role in subjects with symptomatic uncomplicated diverticular disease (SUDD), but the effect of rifaximin therapy has been scantly explored with regard to gut microbiota variations in patients with SUDD. Aims: To verify to which extent rifaximin treatment affects the gut microbiota and whether an electronic multisensorial assessment of stools and breath has the potential for detecting these changes. Methods: Breath and stool samples were collected from consecutive patients with SUDD before and after a 7 days' therapy with rifaximin. Stool microbiota was assessed, and the electronic multisensorial assessment was carried out by means of the BIONOTE electronic (e-)tongue in stools and (e-)nose in breath. Results: Forty-three subjects (female 60%, median age 66 years) were included, and 20 (47%) reported clinical improvement after rifaximin therapy. Alpha and beta diversity of stool microbiota did not significantly change after treatment, while a significant variation of selected taxa was shown (i.e., Citrobacter, Coprococcus, Anaerotruncus, Blautia, Eggerthella lenta, Dehalobacterium, SMB53, and Haemophilus parainfluenzae). Overall, the electronic multisensorial system suboptimally mirrored microbiota changes, but it was able to efficiently predict patients' clinical improvement after rifaximin with accuracies ranging from 0.81 to 0.98. Conclusions: In patients with SUDD, rifaximin administration is associated with significant variation of selected taxa. While inaccurate in predicting gut microbiota change, an electronic multisensorial system, made up of e-tongue and e-nose, was able to predict clinical improvement, thus potentially qualifying as an easy and cheap tool to forecast subjects taking most likely benefit from rifaximin therapy.

17.
Sci Rep ; 10(1): 15222, 2020 09 16.
Artículo en Inglés | MEDLINE | ID: mdl-32938981

RESUMEN

Pleural effusion is very common, but an etiologic diagnosis is often difficult. We used three unconventional diagnostic techniques (voltammetric analysis, protein electrophoresis and pH measurement) performed on pleural effusion to do a preliminary distinction between a neoplastic and a non-neoplastic origin. Pleural fluid samples were collected through thoracentesis, thoracoscopy, or post-surgery pleural drainage of 116 patients admitted to acute care wards. Samples were analyzed with the three unconventional techniques: voltammetric analysis using the BIONOTE system, capillary electrophoresis and pH measurement using a potentiometric method. The BIONOTE system is an innovative system that performs a cyclic voltammetric analysis of a biological liquid sample. The final output of the electrochemical analysis is an electrical pattern that represents a fingerprint of the analyzed sample and each sample has a different fingerprint. Data from the three unconventional diagnostic techniques were analyzed using partial least squares discriminant analysis to discriminate neoplastic from non-neoplastic effusions; we also evaluated sensitivity, specificity and percentage of correct classification. The mean age was 68 years (SD: 12); 78 (67.24%) participants were men. Results obtained from all the unconventional techniques employed showed that neoplastic and non-neoplastic pleural effusions were correctly classified in 80.2% of cases, with a sensitivity of 77% and specificity of 83%. The combined use of voltammetric analysis, protein electrophoresis and pH measurement of pleural fluid can easily and quickly distinguish a neoplastic from a non-neoplastic pleural effusion with reliable accuracy and represents an innovative diagnostic approach. In fact, this protocol can be executed in just few minutes directly in the patient's bed and it holds great promise to improve the prognosis and therapeutic chances.


Asunto(s)
Derrame Pleural/diagnóstico , Proteínas/metabolismo , Toracocentesis/métodos , Toracoscopía/métodos , Anciano , Anciano de 80 o más Años , Drenaje , Electroforesis , Femenino , Humanos , Concentración de Iones de Hidrógeno , Análisis de los Mínimos Cuadrados , Masculino , Persona de Mediana Edad , Derrame Pleural/metabolismo , Derrame Pleural/patología , Derrame Pleural/cirugía , Prueba de Estudio Conceptual , Estudios Prospectivos , Sensibilidad y Especificidad
18.
J Breath Res ; 13(3): 036007, 2019 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-30965288

RESUMEN

E-noses provide potential non-invasive metabolic biomarkers for diagnosing and monitoring pulmonary diseases. The primary aim of the present study was to assess the within-day and between-day repeatability of a modern breath sampling system (Pneumopipe® plus an array of e-nose sensors) in asthmatic and healthy children. The secondary aim was to compare the repeatability of the breath sampling system, spirometry and exhaled nitric oxide (eNO). Fifteen children (age 6-11 years) with asthma and thirty healthy children matched by age and gender (1:2 allocation) were recruited; of them, three healthy children did not complete the study. All measurements were collected twice during the baseline visit, 30 min apart, and once during the final visit, after 7 d. Repeatability was assessed through the intra-cluster correlation coefficient (ICC), and a significance test was performed to detect an at least 'fair' repeatability (ICC > 0.2). In asthmatic children, the within-day (0-30 min) ICCs for e-nose sensors (8 sensors × 4 desorption temperatures) ranged from 0.24 to 0.84 (median 0.57, IQR 0.47-0.71), while the between-day (0-7 d) ICCs ranged from 0.25 to 0.83 (median 0.66, IQR 0.55-0.72). In healthy children, the within-day ICCs for e-nose sensors ranged from 0.29 to 0.85 (median 0.58, IQR 0.49-0.63), while the between-day ICCs ranged from 0.33 to 0.82 (median 0.55, IQR 0.49-0.63). In both groups, most of the within-day and between-day ICCs for e-nose sensors were statistically significant. Moreover, the within-day and between-day ICCs for all spirometry parameters and eNO were significant and similar to those of the most reliable sensors. The modern breath sampling system showed more than acceptable within-day and between-day repeatability, in both asthmatic and healthy children. The present study was registered on the central registration system ClinicalTrials.gov (ID: NCT03025061).


Asunto(s)
Asma/diagnóstico , Pruebas Respiratorias/métodos , Espiración , Estudios de Casos y Controles , Niño , Análisis Factorial , Femenino , Humanos , Masculino , Óxido Nítrico/análisis , Reproducibilidad de los Resultados , Espirometría
19.
Micromachines (Basel) ; 9(7)2018 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-30424276

RESUMEN

The study of ladder networks made by sequences of directly coupled inductor⁻capacitor single cells has led us to discover a new property, which may be of certain interest in the sensor field. In the case of n cells, the n-frequencies vector characterizing each node may allow for the identification of that capacitor (sensor), which has experienced a variation of its nominal value. This localization is possible independently from the observable node of the ladder network as proven by the application of the following multivariate data analysis techniques: principal component analysis and partial least square discriminant analysis. This property can be applied on a large scale down to micrometric dimensions in agreement with the technologic ability to shrink the capacitive sensor dimensions.

20.
Front Chem ; 6: 327, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30148129

RESUMEN

This paper presents an advanced voltammetric system to be used as electronic tongue for liquid and gas analysis. It has been designed to be more flexible and accurate with respect to other existing and similar systems. It features improved electronics and additional operative conditions. Among others these include the possibility to optically excite the solution and to treat the output signal by a differentiation process in order to better evidence the existence of small details in the response curve. Finally by the same type of tongue preliminary results are shown dealing with O2 and CO2 concentration measurements in appropriate solutions.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA