Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 93(3): 1237-1241, 2021 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-33378151

RESUMEN

The development of three-dimensional (3D) single-cell imaging and protein quantitative methods can provide more comprehensive information for diagnoses. We report the design and synthesis of a multisignal nanoprobe (AuGdNC@BSA-CV) for single-cell 3D imaging and quantifying the integrin αIIbß3 using correlated synchrotron radiation soft X-ray tomography microscopy and an iterative tomographic algorithm termed equally sloped tomography for the first time. Moreover, on the basis of the Au or Gd content of our nanoprobe, the number of integrin αIIbß3 on a single cell also can be accurately quantified (1.5 × 107 per cell) via inductively coupled plasma mass spectrometry.


Asunto(s)
Imagenología Tridimensional , Integrinas/análisis , Nanopartículas/química , Análisis de la Célula Individual , Tomografía Computarizada por Rayos X , Línea Celular Tumoral , Gadolinio/química , Oro/química , Humanos , Albúmina Sérica Bovina/química , Sincrotrones
2.
Microsc Microanal ; 23(5): 938-944, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28789720

RESUMEN

Ring artifacts are undesirable and complicate the analysis and interpretation of microstructures in synchrotron X-ray microtomography. Here, we propose a new method to improve the image quality of an object by removing the ring artifacts and investigate the efficiency of this process with tomographic images of a dried Tenebrio molitor. In this method, before the tomographic reconstruction, ring artifacts were identified and located in the sinograms as line artifacts. Then, the identified line artifacts were corrected as single point noise via image processing of the original projections. Eventually, the corresponding line artifacts were removed, resulting in reduced ring artifacts in the reconstructed tomographic images. Simulations verified the efficiency of the proposed method. This method was successfully applied for the structural analysis of the insect T. molitor, showing superior performance in reducing ring artifacts in the tomographic image without noticeable loss of structural information.


Asunto(s)
Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Tenebrio/ultraestructura , Microtomografía por Rayos X/métodos , Animales , Sincrotrones
3.
Anal Chem ; 87(12): 5849-53, 2015 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-26006162

RESUMEN

Novel coherent diffraction microscopy provides a powerful lensless imaging method to obtain a better understanding of the microorganism at the nanoscale. Here we demonstrated quantitative imaging of intact unstained magnetotactic bacteria using coherent X-ray diffraction microscopy combined with an iterative phase retrieval algorithm. Although the signal-to-noise ratio of the X-ray diffraction pattern from single magnetotactic bacterium is weak due to low-scattering ability of biomaterials, an 18.6 nm half-period resolution of reconstructed image was achieved by using a hybrid input-output phase retrieval algorithm. On the basis of the quantitative reconstructed images, the morphology and some intracellular structures, such as nucleoid, polyß-hydroxybutyrate granules, and magnetosomes, were identified, which were also confirmed by scanning electron microscopy and energy dispersive spectroscopy. With the benefit from the quantifiability of coherent diffraction imaging, for the first time to our knowledge, an average density of magnetotactic bacteria was calculated to be ∼1.19 g/cm(3). This technique has a wide range of applications, especially in quantitative imaging of low-scattering biomaterials and multicomponent materials at nanoscale resolution. Combined with the cryogenic technique or X-ray free electron lasers, the method could image cells in a hydrated condition, which helps to maintain their natural structure.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Magnetospirillum/química , Microscopía , Algoritmos , Magnetospirillum/aislamiento & purificación , Relación Señal-Ruido , Difracción de Rayos X
4.
IUCrJ ; 5(Pt 2): 141-149, 2018 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-29765603

RESUMEN

Knowledge of the interactions between nanomaterials and large-size mammalian cells, including cellular uptake, intracellular localization and translocation, has greatly advanced nanomedicine and nanotoxicology. Imaging techniques that can locate nanomaterials within the structures of intact large-size cells at nanoscale resolution play crucial roles in acquiring this knowledge. Here, the quantitative imaging of intracellular nanomaterials in three dimensions was performed by combining dual-energy contrast X-ray microscopy and an iterative tomographic algorithm termed equally sloped tomography (EST). Macrophages with a size of ∼20 µm that had been exposed to the potential antitumour agent [Gd@C82(OH)22] n were investigated. Large numbers of nanoparticles (NPs) aggregated within the cell and were mainly located in phagosomes. No NPs were observed in the nucleus. Imaging of the nanomedicine within whole cells advanced the understanding of the high-efficiency antitumour activity and the low toxicity of this agent. This imaging technique can be used to probe nanomaterials within intact large-size cells at nanometre resolution uniformly in three dimensions and may greatly benefit the fields of nanomedicine and nanotoxicology.

5.
Biomed Opt Express ; 8(12): 5825-5833, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29296507

RESUMEN

Cardiovascular diseases are closely related to structural blood capillaries lesions. Herein, microscopic investigations of mouse blood capillaries were performed at multiple spatial resolution by using synchrotron X-ray in-line phase contrast tomography and scanning transmission X-ray microscopy (STXM). The chemically fixed blood capillaries without any contrast agents were selected. For the first time, a periodic bamboo-shaped structure was observed at nanoscale resolution by STXM, and the three-dimensional tomographic slices at sub-micrometer resolution further confirmed the periodic wave profile of the blood capillaries. Then, a periodic microstructural model was suggested based on the microscopic images. By using high-performance imaging techniques, this work provides a better understanding of the relationship between the structure and function of blood capillaries, will be helpful in elucidating the causes of cardiovascular system diseases.

6.
PLoS One ; 12(3): e0174057, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28296963

RESUMEN

Casting had symbolic significance and was strictly controlled in the Shang dynasty of ancient China. Vessel casting was mainly distributed around the Shang capital, Yin Ruins, which indicates a rigorous centralization of authority. Thus, for a casting mold to be excavated far from the capital region is rare. In addition to some bronze vessel molds excavated at the Buyao Village site, another key discovery of a bronze vessel mold occurred at Daxinzhuang. The Daxinzhuang site was a core area in the east of Shang state and is an important site to study the eastward expansion of the Shang. Here, combining synchrotron X-rays and other physicochemical analysis methods, nondestructive three-dimensional structure imaging and different elemental analyses were conducted on this mold sherd. Through high penetration X-ray tomography, we obtained insights on the internal structure and discovered some pores. We infer that the generation of pores inside the casting mold sherd was used to enhance air permeability during casting. Furthermore, we suppose that the decorative patterns on the surface were carved and not pasted onto it. Considering the previous compositional studies of bronze vessels, the copper and iron elements were analyzed by different methods. Unexpectedly, a larger amount of iron than of copper was detected on the surface. According to the data analysis and archaeological context, the source of iron on the casting mold sherd could be attributed to local soil contamination. A refined compositional analysis confirms that this casting mold was fabricated locally and used for bronze casting.


Asunto(s)
Aleaciones/química , China , Espectroscopía de Fotoelectrones , Espectrometría por Rayos X , Propiedades de Superficie
7.
Sci Rep ; 7: 43595, 2017 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-28240321

RESUMEN

When and under what circumstances domestication related traits evolved in soybean (Glycine max) is not well understood. Seed size has been a focus of archaeological attention because increased soybean seed weight/size is a trait that distinguishes most modern soybeans from their ancestors; however, archaeological seed size analysis has had limited success. Modern domesticated soybean has a significantly higher oil content than its wild counterpart so oil content is potentially a source of new insight into soybean domestication. We investigated soybean oil content using X-ray computed tomography (CT; specifically, synchrotron radiation X-ray CT or SRX-CT) of charred, archaeological soybean seeds. CT identified holes in the specimens that are associated with oil content. A high oil content facilitates the development of small holes, whereas a high protein content results in larger holes. The volume of small holes increased slowly from 7,500 to 4,000 cal B.P. We infer that human selection for higher oil content began as early as 7,500 cal B.P. and that high oil content cultivars were well established by 4,000 cal B.P.


Asunto(s)
Domesticación , Glycine max/química , Aceite de Soja/química , Arqueología , Evolución Biológica , China , Tomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA