RESUMEN
INTRODUCTION: International guidelines recommend routine screening for syphilis (aetiological agent: Treponema pallidum subspecies pallidum) amongst key populations and vulnerable populations using tests detecting treponemal and non-treponemal antibodies. Whilst treponemal tests have high sensitivities and specificities, they differ regarding subjective or objective interpretation, throughput and workload. Chemiluminescence immunoassays (CLIAs) are cost- and time-effective automated methods for detecting treponemal antibodies. The Treponema pallidum particle agglutination assay (TPPA) has been considered the "gold standard" treponemal assay, however, this includes a highly manual procedure, low throughput and subjective interpretation. The present multi-country study evaluated the ADVIA Centaur® Syphilis CLIA (Siemens Healthcare) assay compared to the reference SERODIA-TP·PA® (Fujirebio Diagnostics) for the serodiagnosis of syphilis amongst men who have sex with men (MSM). METHOD: 1,485 MSM were enrolled in Brighton (UK), Malta, and Verona (Italy) as part of a larger WHO multi-country and multi-site ProSPeRo study. Ethical approval was obtained. Serum was tested with the ADVIA Centaur® Syphilis CLIA assay and SERODIA-TP·PA®, in accordance with the manufacturers' instructions, for a first round of validation. A second round of validation was carried out for discrepant results that were additionally tested with both Western Blot (Westernblot EUROIMMUN®) and an Immunoblot (INNO-LIA, Fujirebio Diagnostics). Sensitivity, specificity, positive and negative predictive value (PPV and NPV), likelihood ratios (positive/negative), and the Diagnostic Odds Ratio (DOR)/pre-post-test probability (Fagan's nomogram) were calculated. RESULTS: Out of 1,485 eligible samples analysed in the first phase, the SERODIA-TP·PA® identified 360 positive and 1,125 negative cases. The ADVIA Centaur® Syphilis CLIA assay (Siemens) identified 366 positives, missclassifying one TPPA-positive sample. In the second phase, the ADVIA Centaur® Syphilis CLIA resulted in 1 false negative and 4 false positive results. Considering the syphilis study prevalence of 24% (95% CI: 22-26.7), The sensitivity of the ADVIA Centaur® Syphilis CLIA assay was 99.7% (95% CI: 98.5-100), and the specificity was 99.4% (95% CI: 98.7-99.7). The ROC area values were 0.996 (95% CI: 0.992-0.999), and both the PPV and NPV values were above 98% (PPV 98.1%, 95% CI: 96.1-99.2; NPV 99.9%, 95% CI: 99.5-100). CONCLUSIONS: The ADVIA Centaur® Syphilis CLIA assay showed similar performance compared to the SERODIA-TP·PA®. Considering the study is based on QUADAS principles and with a homogeneous population, results are also likely to be generalisable to MSM population but potentially not applicable to lower prevalence populations routinely screened for syphilis. The automated CLIA treponemal assay confirmed to be accurate and appropriate for routine initial syphilis screening, i.e. when the reverse testing algorithm is applied.
Asunto(s)
Minorías Sexuales y de Género , Sífilis , Masculino , Humanos , Treponema pallidum , Homosexualidad Masculina , Anticuerpos Antibacterianos , Serodiagnóstico de la Sífilis/métodos , Pruebas Serológicas/métodos , Sensibilidad y Especificidad , Mediciones Luminiscentes/métodos , AglutinaciónRESUMEN
BACKGROUND: Sexually transmitted infections (STIs) such as syphilis and HIV remain to be a significant public health issue worldwide. Dual rapid point-of-care tests (POCTs) have shown promise for detecting antibodies to HIV and syphilis but have not been fully evaluated in the field. Our study supported the WHO ProSPeRo study on Sexually Transmitted Infection Point-of-Care Testing (STI POCT) by providing external quality assessment (EQA) for HIV and syphilis testing in reference laboratories and their associated clinical sites in seven countries. METHODS: HIV/syphilis serum liquid and dried tube specimen (DTS) panels were prepared by CDC. Liquid panels were distributed to the reference laboratories for three rounds of testing using commercially and locally available laboratory-based serological tests. DTS panels were sent to the clinical testing sites for 8 rounds of POC testing using the Abbott SD BIOLINE HIV/Syphilis Duo test (hereafter referred to as SD BIOLINE) and the Chembio Dual Path Platform (DPP) HIV-Syphilis assay. EQA panels were tested at CDC using the Rapid Plasma Reagin (RPR) test and the Treponema pallidum Particle Agglutination assay (TP-PA) for syphilis antibodies. Genetic Systems HIV-1/HIV-2 Plus O EIA, Geenius HIV Supplemental Assay and the Oraquick Advance HIV test were used to detect HIV antibodies in the EQA panels. Results from the reference laboratories and POCT sites were compared to those obtained at the CDC and a percentage agreement was calculated. RESULTS: Qualitative RPR and TP-PA performed at the reference laboratories demonstrated 95.4-100% agreement with CDC results while quantitative RPR and TP-PA tests demonstrated 87.7% and 89.2% agreement, respectively. A 93.8% concordance rate was observed for qualitative HIV testing in laboratories. EQA testing at clinical sites using dual tests showed 98.7% and 99.1% agreement for detection of HIV antibodies and eight out of 10 sites had > 95.8% agreement for syphilis testing. However, two clinical sites showed only 65.0-66.7% agreement for SD BIOLINE and 84.0-86.7% for DPP, respectively, for syphilis testing. CONCLUSIONS: Overall, laboratories demonstrated high EQA performance in this study. Both HIV/syphilis POCTs gave expected results in the clinic-based evaluations using DTS. However, testing errors were identified in a few testing sites suggesting the necessity for continuous training and monitoring the quality of POC testing.
Asunto(s)
Infecciones por VIH , VIH-1 , Sífilis , Humanos , Treponema pallidum , Anticuerpos Anti-VIH , Infecciones por VIH/diagnóstico , Sensibilidad y Especificidad , Anticuerpos Antibacterianos , Pruebas en el Punto de Atención , Serodiagnóstico de la Sífilis/métodos , VIH-2 , Organización Mundial de la Salud , Sistemas de Atención de PuntoRESUMEN
INTRODUCTION: Globally, the incidence of HIV and syphilis can be reduced by the use of validated point of care tests (POCTs). As part of the WHO PRoSPeRo Network, we aimed to evaluate the performance, acceptability, and operational characteristics of two dual HIV/syphilis POCTs (Bioline HIV/Syphilis Duo (Abbott) and DPP® HIV-Syphilis assay (Chembio) for the screening of HIV and syphilis amongst men who have sex with men (MSM). METHOD AND ANALYSES: A cross sectional study of 2,577 MSM in Italy, Malta, Peru, and the United Kingdom (UK) presenting to seven clinic sites, were enrolled. Finger prick blood was collected to perform POCTs and results compared with standard laboratory investigations on venepuncture blood. Acceptability and operational characteristics were assessed using questionnaires. Diagnostic meta-analysis was used to combine data from the evaluation sites. RESULTS: Based on laboratory tests, 23.46% (n = 598/2549) of participants were confirmed HIV positive, and 35.88% of participants (n = 901/2511) were positive on treponemal reference testing. Of all participants showing evidence of antibodies to Treponema pallidum, 50.56% (n = 455/900) were Rapid Plasma Reagin (RPR) test reactive. Of HIV positive individuals, 60.62% (n = 354/584) had evidence of antibodies to T. pallidum, and of these 60.45% (n = 214/354) exhibited reactive RPR tests indicating probable (co)infection. For Bioline POCT, pooled sensitivities and specificities for HIV were 98.95% and 99.89% respectively, and for syphilis were 73.79% and 99.57%. For Chembio pooled sensitivities and specificities for HIV were 98.66% and 99.55%, and for syphilis were 78.60% and 99.48%. Both tests can detect greater than 90% of probable active syphilis cases, as defined by reactive RPR and treponemal test results. These dual POCTs were preferred by 74.77% (n = 1,926) of participants, due to their convenience, and the operational characteristics made them acceptable to health care providers (HCPs). CONCLUSIONS: Both the Bioline and the Chembio dual POCT for syphilis and HIV had acceptable performance, acceptability and operational characteristics amongst MSM in the PRoSPeRo network. These dual POCTs could serve as a strategic, more cost effective, patient and healthcare provider (HCP) friendly alternative to conventional testing; in clinical and other field settings, especially those in resource-limited settings.
Asunto(s)
Infecciones por VIH , Minorías Sexuales y de Género , Sífilis , Masculino , Humanos , Sífilis/diagnóstico , Sífilis/epidemiología , Homosexualidad Masculina , Perú/epidemiología , Malta , Estudios Transversales , Treponema pallidum , Pruebas en el Punto de Atención , Serodiagnóstico de la Sífilis/métodos , Sensibilidad y Especificidad , Anticuerpos Antibacterianos , Infecciones por VIH/diagnóstico , Infecciones por VIH/epidemiologíaRESUMEN
BACKGROUND: Several viruses have been described as causes of acquired inflammatory myopathies; however, the mechanisms by which they cause muscle disease are still unclear. The aim of this study was to describe the laboratory features of benign acute myositis in a small case series. METHODS: A detailed pathological and serological analysis was performed in five African migrants who developed an acute viral myositis complicated by rhabdomyolysis. RESULTS: Muscle biopsies clearly documented an inflammatory myopathy with histological features similar to polymyositis including CD8+ T cells surrounding and invading nonnecrotic muscle fibers, CD68+ macrophages and major histocompatibility complex class I antigen upregulation. In addition, positivity for myositis-specific antibodies (MSA), in particular anti-aminoacyl tRNA synthetases, was found in the serum of two patients. CONCLUSIONS: Our study demonstrated that T-cell mediated injury occurs in muscle of patients with acute viral myositis, and that MSA may be present in the serum of these patients.
Asunto(s)
Autoanticuerpos/inmunología , Linfocitos T CD8-positivos/inmunología , Antígenos de Histocompatibilidad Clase I/inmunología , Macrófagos/inmunología , Miositis/inmunología , Virosis/inmunología , Adolescente , Aminoacil-ARNt Sintetasas/inmunología , Anticuerpos Antivirales/inmunología , Camerún/etnología , Côte d'Ivoire/etnología , Creatina Quinasa/sangre , Emigrantes e Inmigrantes , Ghana/etnología , Humanos , Inmunoglobulina G/inmunología , Inmunoglobulina M/inmunología , Italia , Masculino , Miositis/complicaciones , Miositis/patología , Miositis/fisiopatología , Nigeria/etnología , Rabdomiólisis/sangre , Rabdomiólisis/etiología , Partícula de Reconocimiento de Señal/inmunología , Virosis/complicaciones , Virosis/patologíaRESUMEN
OBJECTIVES: The incidence of HIV and syphilis among men who have sex with men (MSM) in Europe has recently increased. Rapid point-of-care tests (POCTs) for syphilis can improve access to screening. The purpose of this study was to evaluate the performance of two syphilis POCTs compared with laboratory tests among MSM. METHODS: The study was undertaken in Verona, Italy. Asymptomatic MSM, potentially exposed to syphilis, were enrolled prospectively. The POCTs evaluated were SD Bioline Syphilis 3.0 and Chembio DPP Syphilis Screen & Confirm Assay on both serum and fingerprick blood. The results of the POCTs were read by the naked eye by two independent readers and their concordance assessed. RESULTS: A total of 289 MSM were enrolled in the study. Based on laboratory tests, 35 MSM (12.1%) were TPPA-positive alone and 16 (5.5%) were both Treponema pallidum particle agglutination test (TPPA) and rapid plasma reagin (RPR)-positive. The specificities of both POCTs were above 99% on both serum and fingerstick blood specimens, while sensitivities varied considerably. The sensitivity of the SD Bioline test was lower on fingerprick blood (51.4% and 54.3%, readers 1 and 2, respectively) compared with that on serum (80.0% and 82.9%). In contrast, the Chembio test exhibited similar sensitivity values for serum and fingerprick samples (57.7% and 64.0% on serum vs 65.4% and 69.2% on fingerprick for the treponemal component; 63.6% on both samples by both readers for the non-treponemal component). The positive predictive value ranged between 100% and 93.9% for the treponemal component of both syphilis POCTs, but was lower (76.3%-100%)%) for the non-treponemal component of the Chembio POCT. The negative predictive value surpassed 90% for both tests on both samples. The agreement between readers was very high (>99%). CONCLUSION: The diagnostic performance of the syphilis POCTs was lower than expected; however, considering the prevalence of syphilis among MSM, POCTs should be recommended to improve syphilis detection among MSM.
Asunto(s)
Sistemas de Atención de Punto , Pruebas en el Punto de Atención , Minorías Sexuales y de Género , Sífilis/diagnóstico , Treponema pallidum/aislamiento & purificación , Adulto , Anticuerpos Antibacterianos/análisis , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y Especificidad , Sífilis/microbiología , Sífilis/transmisiónRESUMEN
INTRODUCTION: In 2016, WHO estimated there were roughly 374 million new infections among adults of the following four curable sexually transmitted infections (STIs): chlamydia (caused by Chlamydia trachomatis (CT)), gonorrhoea (Neisseria gonorrhoeae (NG)), syphilis (Treponema pallidum) and trichomoniasis (Trichomonas vaginalis (TV)). Accurate point-of-care tests (POCTs) for screening of genital and extragenital CT, NG and TV infections are of great value and have been developed during recent decade. Several tests are commercially available and have shown encouraging performance compared with 'gold-standard' reference tests in laboratory-based studies. However, there is limited data on their clinical performance, including at the POC. Key populations, such as men who have sex with men (MSM), are at higher risk of these STIs at genital and extragenital sites and these STIs are often asymptomatic, especially in extragenital sites and in women. We will conduct a clinical-based evaluation to assess the performance characteristics and acceptability to end-users of molecular-based diagnostic technology for POC/near patient use of the Xpert CT/NG (Cepheid, Sunnyvale, California, USA) test for screening of genital, anorectal and pharyngeal CT and NG infections in MSM and the Xpert CT/NG and Xpert TV (Cepheid, Sunnyvale, California, USA) for screening of genital CT, NG and TV among women at risk for these STIs compared with gold-standard reference nucleic acid amplification tests. This master protocol outlines the overall research approach that will be used in seven countries. METHOD AND ANALYSES: Consecutive MSM and women at risk presenting at the clinical sites in high, and low- and middle-income countries will be enrolled. The POCTs to be evaluated are Xpert CT/NG and Xpert TV. All procedures will be carried out by trained healthcare staff and tests performed in strict accordance with the manufacturer's instructions. The sensitivity, specificity, positive and negative predictive values for each POCT will be calculated. The study is ongoing with recruitment expected to be completed in all countries by mid-2022 to late-2022. ETHICS AND DISSEMINATION: Prior to enrolment, this core protocol was independently peer-reviewed and approved by the research project review panel (RP2) of the WHO Department of Sexual and Reproductive Health and Research and by the WHO Ethics Review Committee (ERC). The core protocol has been slightly adapted accordingly to individual countries and adaptations approved by both RP2 and ERC, as well as all relevant institutional review boards at each participating site. Results will be disseminated through peer-reviewed journals and presented at relevant national/international conferences.
Asunto(s)
Infecciones por Chlamydia , Gonorrea , Homosexualidad Masculina , Pruebas en el Punto de Atención , Humanos , Masculino , Femenino , Infecciones por Chlamydia/diagnóstico , Gonorrea/diagnóstico , Estudios Prospectivos , Tamizaje Masivo/métodos , Trichomonas vaginalis/aislamiento & purificación , Enfermedades de Transmisión Sexual/diagnóstico , Vaginitis por Trichomonas/diagnóstico , Vaginitis por Trichomonas/epidemiología , Estudios Multicéntricos como Asunto , Sensibilidad y Especificidad , Adulto , Sistemas de Atención de PuntoRESUMEN
The reactivation of hepatitis B virus (HBVr) in patients undergoing pharmacological immunosuppression is a potentially fatal clinical event that may occur in patients with overt or occult HBV infection. The risk of HBVr is mainly determined by the type of immunosuppressive therapy and the HBV serologic profile, with a higher risk in patients positive for the hepatitis B surface antigen (HBsAg), and a lower risk in HBsAg-negative/antibodies to core antigen-positive subjects. Notably, a considerable proportion of patients experiencing HBVr showed a high degree of variability of the HBV S gene, possibly leading to immune escape mutants. These mutations, usually in the "a-determinant" of the HBsAg, can cause diagnostic problems and consequently hamper the appropriate management strategy of patients at risk of HBVr. Here, we describe a case of HBVr in a patient with a diagnosis of chronic myeloid leukemia and a previous history of kidney transplant, providing evidence of the potential usefulness of hepatitis B core-related antigen measurement in patients with HBV immune-escape mutants at risk of viral reactivation.
RESUMEN
We describe a case of symptomatic acute HIV infection in a young man where a fourth-generation rapid screening test combining HIV-specific antibody and p24 antigen was negative. In highly suspicious cases of acute HIV infection, plasma HIV RNA assays together with conventional, non-rapid screening tests should be used.
Asunto(s)
Anticuerpos Anti-VIH/sangre , Antígenos VIH/sangre , Infecciones por VIH/diagnóstico , VIH-1/aislamiento & purificación , VIH-2/aislamiento & purificación , Adulto , Infecciones por VIH/inmunología , Infecciones por VIH/virología , VIH-1/inmunología , VIH-2/inmunología , Humanos , Inmunoensayo/métodos , Masculino , Valor Predictivo de las Pruebas , Sensibilidad y EspecificidadRESUMEN
A relatively high rate of vancomycin-resistant Enterococcus faecium not susceptible to linezolid was observed in intensive care unit patients. Linezolid-resistant isolates carried the G2576T mutation in the 23S rRNA gene, belonged to different clones, and shared the same allelic profile, which clusters in the C1 multilocus sequence typing epidemic lineage.
Asunto(s)
Acetamidas/farmacología , Enterococcus faecium/efectos de los fármacos , Enterococcus faecium/genética , Oxazolidinonas/farmacología , Alelos , Secuencia de Bases , Infección Hospitalaria/epidemiología , Infección Hospitalaria/microbiología , ADN Bacteriano/genética , Brotes de Enfermedades , Farmacorresistencia Bacteriana/genética , Enterococcus faecium/clasificación , Enterococcus faecium/aislamiento & purificación , Infecciones por Bacterias Grampositivas/epidemiología , Infecciones por Bacterias Grampositivas/microbiología , Humanos , Unidades de Cuidados Intensivos , Italia/epidemiología , Linezolid , Epidemiología Molecular , ARN Bacteriano/genética , ARN Ribosómico 23S/genética , Resistencia a la Vancomicina/genéticaRESUMEN
We described the first case, to the best of our knowledge, of cutaneous abscess due to Eubacterium lentum in a parenteral drug user, after complete fracture of the right femor. The case underlines the importance of carefully performed microbiological tests, due to the peculiar cultural needs of the micro-organism.