Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 98(4): 671-677, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33022098

RESUMEN

OBJECTIVES: To validate novel dedicated 3D-QCA based on the software to calculate post PCI vessel-FFR (vFFR) in a consecutive series of patients, to assess the diagnostic accuracy, and to assess inter-observer variability. BACKGROUND: Low post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) predicts future adverse cardiac events. However, FFR assessment requires the insertion of a pressure wire in combination with the use of a hyperemic agent. METHODS: FAST POST study is an observational, retrospective, single-center cohort study. One hundred patients presenting with stable angina or non ST-elevation myocardial infarction, who underwent post PCI FFR assessment using a dedicated microcatheter were included. Two orthogonal angiographic projections were acquired to create a 3D reconstruction of the coronary artery using the CAAS workstation 8.0. vFFR was subsequently calculated using the aortic root pressure. RESULTS: Mean age was 65±12 years and 70% were male. Mean microcatheter based FFR and vFFR were 0.91±0.07 and 0.91±0.06, respectively. A good linear correlation was found between FFR and vFFR (r = 0.88; p <.001). vFFR had a higher accuracy in the identification of patients with FFR values <0.90, AUC 0.98 (95% CI: 0.96-1.00) as compared with 3D-QCA AUC 0.62 (95% CI: 0.94-0.74). Assessment of vFFR had a low inter-observer variability (r = 0.95; p <.001). CONCLUSION: 3D-QCA derived post PCI vFFR correlates well with invasively measured microcatheter based FFR and has a high diagnostic accuracy to detect FFR <0.90 with low inter-observer variability.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Intervención Coronaria Percutánea , Anciano , Estudios de Cohortes , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Programas Informáticos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 96(3): E204-E212, 2020 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-31789481

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the very long-term clinical outcome after radioactive stent (RS) implantation and intracoronary ß radiation brachytherapy (IRBT). BACKGROUND: Radioactive stents (RS) and intracoronary ß radiation brachytherapy (IRBT) were introduced to prevent restenosis after percutaneous coronary intervention (PCI). Both techniques were associated with a higher incidence of major adverse cardiac events (MACE) in the short and intermediate-term follow up as compared to conventional PCI. METHODS: One hundred and thirty-three patients received radioactive stents (32 P) and 301 patients were treated with IRBT adjunctive to PCI. These groups were propensity matched to respectively 266 and 602 control patients who were treated with routine PCI during the same inclusion period. Endpoints were all-cause mortality and MACE, defined as all-cause death, any myocardial infarction or any revascularization. RESULTS: Median follow-up duration was 17 years. All-cause mortality rates were similar in all groups. Adjusted hazard ratios for MACE and mortality in the RS cohort were 1.55 (95% CI 1.20-2.00) and 0.92 (95% CI 0.63-1.34), respectively. Adjusted hazard ratios for MACE and all-cause mortality in the IRBT cohort were 1.41 (95% CI 1.18-1.67) and 0.95 (95% CI 0.74-1.21), respectively. The difference in MACE rates was predominantly driven by coronary revascularizations in both groups, with a higher MI rate in the IRBT group as well. CONCLUSIONS: Coronary radiation therapy was associated with early increased MACE rates, but the difference in MACE rates decreased beyond 2 years, resulting in a comparable long-term clinical outcome. Importantly, no excess in mortality was observed.


Asunto(s)
Braquiterapia , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/prevención & control , Intervención Coronaria Percutánea/instrumentación , Stents , Anciano , Braquiterapia/efectos adversos , Braquiterapia/mortalidad , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Países Bajos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 95(6): 1085-1091, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31301161

RESUMEN

OBJECTIVE AND BACKGROUND: The study aim is to provide long-term clinical outcome after percutaneous coronary intervention (PCI) for unprotected left main coronary arteries (ULMCA) stenosis with the first-generation (1st -gen) drug-eluting stents (DES) in comparison to 2nd -gen DES, since this is largely unknown. METHODS: Between May 2002, and December 2014, a consecutive series of 656 all-comer patients underwent a PCI for ULMCA stenosis at the Erasmus Medical Center. A total of 235 patients were treated with 1st -gen DES, while a total of 421 patients were treated with 2nd -gen DES. RESULTS: Overall, the population consisted of 73% males and 58% presented with an acute coronary syndrome. Median follow-up time was 1,361 days (range from 0 to 5,031). At 5 years, the cumulative incidence of major adverse clinical events (the primary composite endpoint of all-cause death, any myocardial infarction or target lesion revascularization; MACE) did not differ between 1st - and 2nd -gen DES (36.8 vs. 38.6%, respectively, Log Rank p = .79, adjusted hazard ratio [HR] = 1.28 [95% confidence interval (CI) 0.94-1.74]). No difference was found in the individual endpoints of all-cause mortality (29.5 vs. 29% respectively, p = .88, adjusted HR = 1.19 [95% CI, 0.84-1.68]), target vessel myocardial infarction (5.0 vs. 8.4%, p = 0.17, adjusted HR = 1.75 [95% CI, 0.78-3.96]) and target lesion revascularization (8.1 vs. 9.8%, p = .94, adjusted HR = 1.16 [95% CI, 0.59-2.29]) between the 1st - and 2nd -gen DES cohorts, respectively. CONCLUSIONS: In this large cohort of consecutive patients treated for ULMCA stenosis, no significant differences were found in the safety and efficacy of 1st versus 2nd -gen DES at 5 years follow-up.


Asunto(s)
Síndrome Coronario Agudo/terapia , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Age Ageing ; 49(3): 389-394, 2020 04 27.
Artículo en Inglés | MEDLINE | ID: mdl-32091096

RESUMEN

BACKGROUND: delirium is an event leading to negative health outcomes and increased mortality in patients. The aim of this study is to investigate the incidence, determinants and consequences of post-operative delirium (POD) in older patients undergoing transcatheter aortic valve implantation (TAVI). METHODS: The TAVI Care and Cure program is a prospective, observational registry in patients referred for TAVI at Erasmus University Medical Centre. The presence of delirium was evaluated by daily clinical assessment by a geriatrician pre- and up to 3 days post-TAVI. Mortality data were obtained from the Dutch Civil Registry. RESULTS: A total of 543 patients underwent TAVI between January 2014 and December 2017. Overall, the incidence of POD was 14% (75/543 patients) but declined from 18% in 2014 to 7% in 2017 (P = 0.009). Patients who developed POD were older (81.9 ± 5.8 versus 78.6 ± 8.3 years, P < 0.001), had higher prevalence of renal dysfunction and prior stroke (54% versus 40%, P = 0.02; 31% versus 18%, P = 0.01) and were more often frail (32% versus 25%, P = 0.02). From a procedural perspective, general anesthesia (odds ratios (OR), 2.31; 95% CI, 1.40-3.83; P = 0.001), non-transfemoral access (OR, 2.37; 95% CI, 1.20-4.70; P = 0.01) and longer procedural time (OR, 1.01; 95% CI, 1.01-1.02; P < 0.001) were significantly associated with POD. One-year survival rate was 68% among patients who had suffered a POD and was 85% in patients without a POD (hazard ratio's 1.8 (95% CI 1.01-3.10), P = 0.045). CONCLUSION: POD frequently occurs after TAVI and is associated with increased mortality. It might be speculated that patient selection and the minimalistic approach of TAVI may reduce the frequency of delirium.


Asunto(s)
Estenosis de la Válvula Aórtica , Delirio , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Delirio/diagnóstico , Delirio/epidemiología , Humanos , Incidencia , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Age Ageing ; 49(6): 989-994, 2020 10 23.
Artículo en Inglés | MEDLINE | ID: mdl-32421189

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) brings symptom relief and improvement in health-related quality of life (HRQoL) in the majority of patients treated for symptomatic, severe aortic stenosis. However, there is a substantial group of patients that do not benefit from TAVI. The aim of this study is to investigate the impact of frailty on HRQoL 1 year after TAVI. METHODS: The TAVI Care & Cure Program is an ongoing, prospective, observational study including patients referred for TAVI to our institution. A comprehensive geriatric assessment was performed to evaluate existence of frailty using the Erasmus Frailty Score (EFS). HRQoL was assessed using the EQ-5D-5 L at baseline and 1 year after TAVI. RESULTS: 239 patients underwent TAVI and completed HRQoL assessment 1 year after TAVI. Seventy (29.3%) patients were classified as frail (EFS ≥ 3). In non-frail patients, the EQ-5D-5 L index did not change (0.71(± 0.22) to 0.68(± 0.33) points, P = 0.22); in frail patients, the EQ-5D-5 L index decreased from 0.55(±0.26) to 0.44 points (±0.33) (P = 0.022). Frailty was an independent predictor of deteriorated HRQoL 1 year after TAVI (OR 2.24, 95% CI 1.07-4.70, P = 0.003). In frail patients, the absence of peripheral artery disease (OR 0.17, 95% 0.05-0.50, P = 0.001) and renal dysfunction (OR 0.13, 95% CI 0.04-0.41, P = <0.001) at baseline was associated with improved HRQoL 1 year after TAVI. CONCLUSION: Frailty is associated with deterioration of HRQoL 1 year after TAVI. Notably, HRQoL did improve in frail patients with no peripheral arterial disease or renal impairment at baseline.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Anciano Frágil , Fragilidad/diagnóstico , Humanos , Estudios Prospectivos , Calidad de Vida , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
6.
Am Heart J ; 213: 66-72, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31128504

RESUMEN

BACKGROUND: Post percutaneous coronary intervention (PCI) fractional flow reserve (FFR) is a significant predictor of major adverse cardiac events (MACE). The rationale for low post procedural FFR values often remains elusive based on angiographic findings alone, warranting further assessment using an FFR pullback or additional intravascular imaging. It is currently unknown if additional interventions intended to improve the PCI, decrease MACE rates. STUDY DESIGN: The FFR REACT trial is a prospective, single-center randomized controlled trial in which 290 patients with a post PCI FFR <0.90 will be randomized (1:1) to either standard of care (no additional intervention) or intravascular ultrasound (IVUS)-directed optimization of the FFR (treatment arm). Eligible patients are those treated with angiographically successful PCI for (un)stable angina or non-ST elevation myocardial infarction (MI). Assuming 45% of patients will have a post PCI FFR <0.90, approximately 640 patients undergoing PCI will need to be enrolled. Patients with a post PCI FFR ≥ 0.90 will be enrolled in a prospective registry. The primary end point is defined as a composite of cardiac death, target vessel MI and clinically driven target vessel revascularisation (target vessel failure) at 1 year. Secondary end points will consist of individual components of the primary end point, procedural success, stent thrombosis and correlations on clinical outcome, changes in post PCI Pd/Pa and FFR and IVUS derived dimensions. All patients will be followed for 3 years. CONCLUSION: The FFR-REACT trial is designed to explore the potential benefit of HD-IVUS-guided PCI optimization in patients with a post PCI FFR <0.90 (Dutch trial register: NTR6711).


Asunto(s)
Angina Estable/terapia , Endosonografía/métodos , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio sin Elevación del ST/terapia , Intervención Coronaria Percutánea/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto , Angina Estable/fisiopatología , Humanos , Revascularización Miocárdica , Infarto del Miocardio sin Elevación del ST/fisiopatología , Estudios Prospectivos , Nivel de Atención
7.
Catheter Cardiovasc Interv ; 94(6): 795-805, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-30901147

RESUMEN

OBJECTIVES: To explore the prevalence of smoking, and its association with clinical and mortality outcome among patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Less data exist regarding the effect of baseline smoking status on clinical and mortality outcome among patients undergoing TAVR. METHODS: Consecutive patients who underwent TAVR at two high volume Dutch centers were included. Smoking status was prospectively questioned by a structured interview at admission. Primary endpoint was 1-year all-cause mortality after TAVR. RESULTS: A total of 913 consecutive patients (80.1 ± 7.6 years; logistic EuroSCORE: 16.5 ± 9.9%) who underwent TAVR for severe aortic valve stenosis were included. There were 47% (n = 432) males, and 57% (n = 522) never-smokers, and 35% (n = 317) prior-smokers, and 8% (n = 74) current-smokers. Smokers (i.e., prior-smokers or current-smokers) were younger compared to never-smokers (78.9 ± 7.9 and 76.4 ± 8.0 vs. 81.3 ± 7.1, P < 0.000, respectively). Median follow-up time was 365 (interquartile range [IQR]: 280-365) days. Overall, prior-smoking was not associated with all-cause mortality at 1-year following TAVR (hazard ratio [HR] 0.83, 95% confidence interval [CI] 0.55-1.23). After stratification according to sex, male prior-smokers showed better 1-year survival after TAVR than male never-smokers (12% vs. 20%; P = 0.018, respectively, HR 0.52, 95% CI 0.29-0.89), while this reversed effect was not observed among female prior-smokers versus female never-smokers after TAVR (HR 1.70, 95% CI 0.95-3.05). CONCLUSIONS: Overall, baseline prior-smokers had similar 1-year mortality outcome after TAVR compared with baseline never-smokers. However, there was a reversed association between baseline prior-smoking status and 1-year mortality after TAVR among males, which could partially be explained due to the favorable baseline characteristics.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Fumar Cigarrillos/efectos adversos , Ex-Fumadores , No Fumadores , Fumadores , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Fumar Cigarrillos/mortalidad , Femenino , Humanos , Masculino , Países Bajos , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores Sexuales , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
8.
Europace ; 18(suppl 4): iv44-iv52, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28011830

RESUMEN

AIMS: Left bundle branch block (LBBB) is induced in approximately one-third of all transcatheter aortic valve implantation (TAVI) procedures. We investigated electrophysiological remodelling in patients with TAVI-induced LBBB. METHODS AND RESULTS: This retrospective study comprises 107 patients with initially narrow QRS complex of whom 40 did not and 67 did develop persistent LBBB after TAVI. 12-lead electrocardiograms (ECGs) taken before TAVI, within 24 hours ('acute'), and 1-12 months after TAVI ('chronic') were used to reconstruct vectorcardiograms. From these vectorcardiograms, QRS and T-wave area were calculated as comprehensive indices of depolarization and repolarization abnormalities, respectively. TAVI-induced LBBB resulted in significant acute depolarization and repolarization changes while further repolarization changes were observed with longer lasting LBBB. The amount of long-term repolarization changes (remodelling) was highly variable between patients. The change in T-wave area between acute and chronic LBBB ranged from +57% to - 77%. After dividing the LBBB cohort into tertiles based on the change in T-wave area, only baseline QRS area was larger in the tertile with no significant change in T-wave area. During longer lasting LBBB, the spatial vector gradient (SVG) changed orientation towards the direction of the QRS-vector, indicating that later-activated regions developed shorter action potential duration. CONCLUSION: This study in patients with TAVI-induced LBBB shows that repolarization changes develop within months after onset of LBBB, and that these changes are highly variable between individual patients.


Asunto(s)
Potenciales de Acción , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/fisiopatología , Enfermedad Iatrogénica , Modelos Cardiovasculares , Modelación Específica para el Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Electrocardiografía , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Países Bajos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Procesamiento de Señales Asistido por Computador , Factores de Tiempo , Vectorcardiografía
9.
Cardiovasc Ultrasound ; 14(1): 37, 2016 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-27600600

RESUMEN

To make assessment of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) more uniform the second Valve Academic Research Consortium (VARC) recently updated the echocardiographic criteria for mild, moderate and severe PVL. In the VARC recommendation the assessment of the circumferential extent of PVL in the short-axis view is considered critical. In this paper we will discuss our observational data on the limitations and difficulties of this particular view, that may potentially result in overestimation or underestimation of PVL severity.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Humanos , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo
10.
Catheter Cardiovasc Interv ; 86(5): 875-85, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26032764

RESUMEN

OBJECTIVES: We sought to evaluate the impact of mixed aortic stenosis (MAS) on postprocedural aortic regurgitation (PPAR) and clinical outcomes after transcatheter aortic valve implantation (TAVI). BACKGROUND: The impact of MAS of TAVI outcomes is unknown. METHODS AND RESULTS: Data from a multicenter registry were retrospectively analysed. Outcomes were compared between patients with pure aortic stenosis (PAS; associated AR<1+/3+) and MAS (associated AR≥1+/3+). Study objectives were PPAR incidence and short- and long-term mortality. Overall, 1,062 patients were included: 419 (39.4%) with MAS and 643 (60.5%) with PAS. At 30 days, there were no differences in mortality, however, a higher incidence of major bleeding (22.7% vs. 16.8%; P=0.016), PPAR≥1+/3+ (42.6% vs. 26.5%; P<0.001) and lower device success (89.3% vs. 93.3%; P=0.019) was observed in patients with MAS. Of note, MAS was an independent predictor of PPAR≥1+/3+ at multivariable analysis (OR: 2.882; CI: 1.851-4.488; P<0.001). At 2 years of follow-up, no survival differences were present between MAS and PAS groups. Similarly, following stratification for PPAR≥1+/3+, MAS had no protective effect on survival as compared with PAS. CONCLUSIONS: MAS was associated with lower device success and higher PPAR incidence. However, despite these findings, it had no influence on long-term postoperative outcomes.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Oportunidad Relativa , Modelos de Riesgos Proporcionales , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía
11.
Catheter Cardiovasc Interv ; 85(5): E144-52, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25504891

RESUMEN

OBJECTIVES: The aim of the study was to investigate trends over time in the occurrence of left bundle branch block (LBBB) and permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) with the Medtronic CoreValve System (MCS) and Edwards SAPIEN Valve (ESV). BACKGROUND: TAVI-induced conduction abnormalities (TAVI-CAs) such as LBBB and the need for PPI are frequent postoperative complication. New techniques, procedural refinements, and increased awareness are focused on the reduction of these abnormalities. METHODS: Electrocardiograms of 549 patients without preprocedural LBBB and/or pacemaker were assessed to determine the frequency and nature of TAVI-CAs. To study the effect of experience, patients were subdivided per center into tertiles based on the number of procedures. Univariate and multivariate logistic regression was used to study predictors of TAVI-induced LBBB (TAVI-LBBB) and PPI. RESULTS: TAVI-LBBB occurred in 185 patients (33.7%) and significantly decreased over time, from 42.6% to 27.3% (P=0.006). This effect was only significant after implantation of the MCS (59.6% vs. 46.5% vs. 31.1%, P=0.001, ESV: 22.6% vs. 13.1% vs. 24.8%, P=0.11). Between tertiles there was no difference in the frequency of PPI after TAVI (n=73, 13.1% vs. 14.8% vs. 12%, P=0.74). Multivariate analysis revealed that, independent from valve type, depth of implantation was the only significant predictor of TAVI-LBBB (OR [95% C.I.]: 1.16 [1.10-1.24], P<0.001). In case of PPI pre-existing RBBB (OR [95% C.I.]: 7.22 [3.28-15.88], P<0.001) was the only significant predictor. CONCLUSIONS: Over time the frequency of LBBB after TAVI decreased significantly, especially in patients undergoing TAVI with the MCS. Experience and the subsequent reduction in depth of implantation seem responsible for this reduction. Contrary to TAVI-LBBB, the incidence of PPI remained unchanged over time and was not affected by experience. Although experience has led to a decrease in new CAs after TAVI, elucidation of pathophysiologic mechanisms underlying these CAs and subsequent changes in patient stratification, valve design and the procedure are needed to further reduce this complication.


Asunto(s)
Bloqueo de Rama/epidemiología , Marcapaso Artificial , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Electrocardiografía , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Incidencia , Masculino , Países Bajos/epidemiología , Quebec/epidemiología , Estudios Retrospectivos
12.
Cardiovasc Ultrasound ; 13: 29, 2015 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-26113031

RESUMEN

BACKGROUND: Symptoms in the elderly patients with severe aortic stenosis (AS) and co-morbidities seem to lack in specificity. Therefore, objective parameters for increased left ventricular(LV) filling pressures are needed. The aim of this study was to investigate the correlation between the septal, lateral and average E/e' ratio and the value of the N-terminal pro-hormone of brain natriuretic peptide (NT-proBNP). METHODS: Two-hundred-fifty consecutive symptomatic patients (mean age 80 ± 8 years, 52% men) with severe AS underwent transthoracic echocardiography and NT-proBNP measurement. RESULTS: In the overall population the septal E/e' (r = 0,459, r(2) = 0,21, P <0,0001), lateral E/e' (r = 0,322, r(2) = 0,10, P <0,0001), and the average E/e' (r = 0,432, r(2) = 0,18, P <0,0001) were all significantly correlated to NT-proBNP. After the exclusion of patients with confounders (more than mild aortic or mitral regurgitation, severe renal dysfunction, obesity or severe COPD) the septal E/e' (r = 0,584, r(2) = 0,34, P <0,0001), lateral E/e' (r = 0,377, r(2) = 0,14, P <0,0001), and the average E/e' (r = 0,487, r(2) = 0,24, P <0,0001) were all significantly better correlated to NT-proBNP. In obese patients no significant correlations were seen. Previous bypass surgery did not alter the correlations. CONCLUSIONS: In elderly patients with severe symptomatic AS there is a significant correlation between the E/e' ratio and NT-proBNP, in particular after exclusion of confounders. The correlation was best for the septal E/e' ratio and was preserved in patients with a history of bypass surgery.


Asunto(s)
Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Volumen Sistólico , Disfunción Ventricular Izquierda/sangre , Disfunción Ventricular Izquierda/diagnóstico por imagen , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Biomarcadores/sangre , Ecocardiografía/métodos , Femenino , Evaluación Geriátrica/métodos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Disfunción Ventricular Izquierda/etiología
13.
Biomarkers ; 19(7): 611-9, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25196123

RESUMEN

OBJECTIVE: To investigate relations of several circulating chemokines with extent and phenotype of coronary atherosclerosis and with 1-year clinical outcome. METHODS: Intravascular ultrasound virtual histology (IVUS-VH) imaging of a coronary artery was performed in 581 patients. Monocyte chemoattractant protein-1 (MCP-1), macrophage inflammatory protein-1α (MIP-1α), MIP-1ß and regulated upon activation normal T cell expressed and secreted (RANTES) were measured in plasma. RESULTS: Higher MCP-1, MIP-1α and lower RANTES were associated with coronary plaque burden. Higher MCP-1, MIP-1α and lower RANTES were associated with the presence of IVUS-VH-derived thin-cap fibroatheroma lesions. RANTES was associated with major adverse cardiac events. CONCLUSIONS: RANTES is a promising biomarker that is inversely associated with coronary plaque burden and vulnerability, as well as with death and acute coronary syndrome.


Asunto(s)
Quimiocinas/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Placa Aterosclerótica , Ultrasonografía Intervencional , Anciano , Biomarcadores/sangre , Quimiocina CCL2/sangre , Quimiocina CCL3/sangre , Quimiocina CCL4/sangre , Quimiocina CCL5/sangre , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/terapia , Femenino , Fibrosis , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Necrosis , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Factores de Tiempo
14.
Europace ; 16(5): 750-7, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24798965

RESUMEN

AIMS: Conventional electrocardiogram (ECG)-based diagnosis of left bundle branch block (LBBB) in patients with left ventricular hypertrophy (LVH) is ambiguous. Left ventricular hypertrophy is often seen in patients with severe aortic stenosis in which a transcatheter aortic valve implantation (TAVI) frequently results in a LBBB due to the mechanical interaction of the artificial valve and the conduction system. In this feasibility study, we propose and evaluate the sensitivity of a new electrocardiographic imaging tool; the cardiac isochrone positioning system (CIPS), visualizing the cardiac activation to detect interventricular conduction patterns pre- and post-TAVI. METHODS AND RESULTS: The CIPS translates standard 12-lead ECG into ventricular isochrones, representing the activation sequence. It requires a patient-specific model integrating heart, lungs, and other thoracic structures derived from multi-slice computed tomography. The fastest route-based algorithm was used to estimate the activation isochrones and the results were compared with standard ECG analysis. In 10 patients the CIPS was used to analyse 20 ECGs, 10 pre- and 10 post-TAVI. In 11 cases the CIPS results were in agreement with the ECG-based diagnosis. In two cases there was partial agreement and in seven cases there was disagreement. In four of these cases, the clinical history of the patients favoured interpretation as assessed by CIPS, for the remaining three, it is unknown which method correctly classified the activation. CONCLUSION: This feasibility study applying the CIPS shows promising results to classify conduction disorders originating from the left anterior or posterior ventricular wall, or the septum. The visualization of the activation isochrones as well as ventricular model-derived features might support TAVI procedures and the therapy selection afterwards.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/diagnóstico , Técnicas Electrofisiológicas Cardíacas/métodos , Procesamiento de Señales Asistido por Computador , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Bloqueo de Rama/complicaciones , Estudios de Cohortes , Electrocardiografía/métodos , Estudios de Factibilidad , Femenino , Humanos , Hipertrofia Ventricular Izquierda/complicaciones , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad , Reemplazo de la Válvula Aórtica Transcatéter/métodos
15.
Curr Cardiol Rep ; 16(1): 429, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24281975

RESUMEN

Transcatheter aortic valve implantation (TAVI) has become an established treatment option for patients with aortic stenosis at prohibitive risk to undergo surgical aortic valve replacement. Despite conveying obvious clinical benefits and a decreasing frequency of complications, the occurrence of new conduction abnormalities and arrhythmias remains an important issue. Generally considered a minor complication, they may have a profound impact on prognosis and quality of life after TAVI. Therefore the purpose of this review is to assess and discuss the available information on clinical implications of both new conduction abnormalities and arrhythmias after TAVI.


Asunto(s)
Válvula Aórtica/cirugía , Arritmias Cardíacas/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Fibrilación Atrial/etiología , Fibrilación Atrial/terapia , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/terapia , Cateterismo Cardíaco , Estimulación Cardíaca Artificial , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos
17.
Am Heart J ; 165(2): 183-92, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23351821

RESUMEN

BACKGROUND: Transfemoral transcatheter aortic valve implantation (TF-TAVI) is a viable and safe treatment strategy for patients with symptomatic severe aortic stenosis and high operative risk and has been introduced as such in the recently updated European guidelines on the management of valvular heart disease.Our aim was to assess trends in outcome after TF-TAVI. METHODS: Propensity score-matched analysis of a multicenter registry of consecutive patients undergoing TF-TAVI subdivided into 3 tertiles based on enrollment date was performed. Three tertiles of 214 propensity score-matched patients were compared. RESULTS: With mounting experience and moving from the initial to the last cohort, procedural contrast volume and radiation time decreased. Over time, there were less major vascular complications (15% vs 7.9%, P = .023), life-threatening bleedings (17.8% vs 7.9%, P = .003), and major bleedings (22.4% vs 12.1%, P = .007). Major vascular complications and life-threatening bleedings caused by closure device failure decreased significantly (9.2% vs 3.1% [P = .01] and 5.7% vs 1 % [P = .01], respectively). The combined safety end point dropped from 31.3% in tertile (T) (T1) to 17.8% in T3 (P < .001). By multivariable analysis, the last cohort as compared with the initial cohort was associated with significant reductions in 30-day mortality (odds ratio [OR] 0.35, 95% CI 0.12-0.96), stage 3 AKI (OR 0.12, 95% CI 0.29-0.93), and the combined safety end point (OR 0.52, 95% CI 0.29-0.93). One-year survival improved significantly (T1 79% vs T3 86%, P = .016). CONCLUSIONS: Over time, TAVI is performed with significant reductions in major vascular complications, life-threatening bleedings, and the combined clinical safety end point and improved 1-year survival.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/mortalidad , Sistema de Registros , Anciano de 80 o más Años , Causas de Muerte/tendencias , Europa (Continente)/epidemiología , Femenino , Arteria Femoral , Estudios de Seguimiento , Humanos , Masculino , Oportunidad Relativa , Puntaje de Propensión , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
18.
Am Heart J ; 165(5): 752-60, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23622912

RESUMEN

BACKGROUND: Only limited and conflicting data on the impact of preoperative chronic kidney disease (CKD) on outcomes after transcatheter aortic valve implantation (TAVI) are available. METHODS: We retrospectively analyzed pooled data from the prospective TAVI databases of 4 centers (942 patients). Valve Academic Research Consortium end point definitions were used. The outcomes were compared among patients with normal estimated glomerular filtration rate (≥90 mL/min), mild (60-89 mL/min), moderate (30-59 mL/min), and severe (<30 mL/min) CKD and those on chronic hemodialysis (HD). The primary end point was 1-year survival. RESULTS: A total of 109 patients had a normal estimated glomerular filtration rate (11.6%); 329 (34.9%) had mild, 399 (42.5%) moderate, 72 (7.5%) severe CKD, and 33 (3.5%) were on HD. Baseline and procedural characteristics were similar among all groups except for Logistic EuroSCORE. Major stroke, life-threatening bleeding, all-cause 30-day mortality (HD 15.2%, severe CKD 8.3%, moderate CKD 8.3%, mild CKD 6.7%, normal 1.8%, P = .007) and 1-year survival (HD 54.8%, severe CKD 67.2%, moderate CKD 80.0%, mild CKD 85.2%, normal eGFR 91.4%, HD vs severe CKD P = .23, severe CKD vs moderate CKD P = .002, moderate CKD vs mild CKD P = .04, moderate CKD vs normal eGFR P = .03, by log-rank test) differed significantly across groups. Through multivariable analysis, HD and severe CKD were independently associated with an increased risk of 1-year mortality (hazard ratios 5.07 [95% CI 1.79-14.35, P = .002] and 4.03 [95% CI 1.52-10.69, P = .005], respectively). CONCLUSIONS: Patients with CKD who undergo TAVI have a higher-risk profile and worse 30-day and 1-year outcomes. Chronic hemodialysis and severe preprocedural CKD are independently associated with an increased risk of 1-year mortality after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia Renal Crónica/complicaciones , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Francia/epidemiología , Tasa de Filtración Glomerular , Humanos , Masculino , Países Bajos/epidemiología , Estudios Prospectivos , Insuficiencia Renal Crónica/mortalidad , Insuficiencia Renal Crónica/fisiopatología , Factores de Riesgo , Tasa de Supervivencia/tendencias
19.
Chin Med J (Engl) ; 2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37606001

RESUMEN

BACKGROUND: Due to the wide variety of morphology, size, and dynamics, selecting an optimal valve size and location poses great difficulty in percutaneous pulmonary valve implantation (PPVI). This study aimed to report our experience with in vitro bench testing using patient-specific three-dimensional (3D)-printed models for planning PPVI with the Venus P-valve. METHODS: Patient-specific 3D soft models were generated using PolyJet printing with a compliant synthetic material in 15 patients scheduled to undergo PPVI between July 2018 and July 2020 in Central China Fuwai Hospital of Zhengzhou University. RESULTS: 3D model bench testing altered treatment strategy in all patients (100%). One patient was referred for surgery because testing revealed that even the largest Venus P-valve would not anchor properly. In the remaining 14 patients, valve size and/or implantation location was altered to avoid valve migration and/or compression coronary artery. In four patients, it was decided to change the point anchoring because of inverted cone-shaped right ventricular outflow tract (RVOT) (n = 2) or risk of compression coronary artery (n = 2). Concerning sizing, we found that an oversize of 2-5 mm suffices. Anchoring of the valve was dictated by the flaring of the in- and outflow portion in the pulmonary artery. PPVI was successful in all 14 patients (absence of valve migration, no coronary compression, and none-to-mild residual pulmonary regurgitation [PR]). The diameter of the Venus P-valve in the 3D simulation group was significantly smaller than that of the conventional planning group (36 [2] vs. 32 [4], Z = -3.77, P <0.001). CONCLUSIONS: In vitro testing indicated no need to oversize the Venus P-valve to the degree recommended by the balloon-sizing technique, as 2-5 mm sufficed.

20.
Am Heart J ; 164(3): 402-9, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22980308

RESUMEN

BACKGROUND: Little is known about the impact of bleeding and red blood cells transfusion (RBC) on the outcome post transcatheter aortic valve implantation (TAVI). METHODS: Between November 2005 and August 2011, 943 consecutive patients underwent TAVI. Bleeding was assessed according to the Valve Academic Research Consortium definitions. Patients receiving RBC were compared to those not requiring transfusion. RESULTS: Life-threatening and major bleedings occurred respectively in 13.9% and 20.9% of the patients, significantly more frequently in the RBC cohort. Vascular complications occurred in 23.2% of the patients. Major and minor vascular complications were more frequent in the RBC group: 19.3 vs 5.2%, P < .001; 15.3 vs 9%, P = .003, respectively. Thirty-day all-cause mortality was 7.2%. Of the overall cohort, 38.9% required RBC transfusion; those receiving at least 4 U of RBC had higher 30-day all-cause mortality than those receiving 1 to 4 U of RBC and those not requiring transfusion: 14.4%, vs 6.3% vs 6.3%, respectively, P = .008. By multivariate analysis, transfusion of RBC was associated with an increased 30-day and 1-year mortality. Major stroke and all stages of acute kidney injury were significantly more frequent in the RBC cohort. CONCLUSIONS: Bleeding is frequent after TAVI, mainly driven by vascular complications. RBC transfusion was associated with increased mortality at 1 year and increased risk of major stroke and acute kidney injury. Specific scores are needed to identify the patients at higher risk for TAVI-related bleeding and RBC transfusion.


Asunto(s)
Transfusión de Eritrocitos/efectos adversos , Cardiopatías Congénitas/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Hemorragia Posoperatoria/etiología , Lesión Renal Aguda/etiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Enfermedad de la Válvula Aórtica Bicúspide , Cateterismo Cardíaco , Estudios de Cohortes , Femenino , Cardiopatías Congénitas/mortalidad , Enfermedades de las Válvulas Cardíacas/mortalidad , Humanos , Masculino , Hemorragia Posoperatoria/diagnóstico , Hemorragia Posoperatoria/terapia , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA