Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Transfusion ; 61(8): 2450-2457, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33913163

RESUMEN

BACKGROUND: Early plasma transfusion for management of bleeding, particularly trauma, is associated with better outcomes. Improving the availability/safety of plasma transfusion for patients is essential for transfusion services. The aim of this study is to evaluate the hemostatic capacity of methylene-blue (MB) liquid (not frozen) plasma over time. MATERIALS AND METHODS: Twenty whole blood-derived plasma units collected from male donors were separated and processed within 18 h of collection. Individual plasmas were treated with MB and stored in liquid status at 2-6°C for 14 days. A range of coagulation assays, including thrombin generation, rotational thromboelastometry (ROTEM), and Thrombodynamics were tested at different time-points, together with bacterial growth. RESULTS: Apart from Factor (F)XII, other coagulation factors (fibrinogen, FV, FVIII, FXI) reduced significantly after MB treatment, with levels remaining stable except for FVIII afterward. By day 14, most clotting factors were >0.7 IU/ml, apart from FVIII. There was a disproportionate decrease in Protein S (PS) activity compared to free PS antigen and by day 14 its value was ~50%. There was no significant difference in maximum clot formation (ROTEM) and clot-density (Thrombodynamics) over time. Endogenous thrombin potential (Thrombin-Generation), clot-size, and velocity index (Thrombodynamics) decreased significantly over time consistent with clotting factor reduction. There was no bacterial growth. CONCLUSIONS: MB-treated liquid plasma stored at 2-6°C can be used for up to 14 days: the long shelf-life, the liquid status, and the MB treatment will improve its availability for management of bleeding as well as providing a safe component from pathogens.


Asunto(s)
Coagulación Sanguínea/efectos de los fármacos , Conservación de la Sangre/métodos , Seguridad de la Sangre/métodos , Azul de Metileno/farmacología , Plasma/metabolismo , Pruebas de Coagulación Sanguínea , Transfusión de Componentes Sanguíneos , Humanos , Masculino , Plasma/química
2.
Transfusion ; 58(12): 2942-2951, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30362131

RESUMEN

BACKGROUND: The INTERCEPT Blood System (IBS) for platelets (PLTs) uses a combination of psoralen and ultraviolet-A light to inactivate pathogens that may contaminate PLT concentrates (PCs). However, no data are available on the quality of IBS-treated PLTs from different apheresis and buffy-coat PC preparation platforms using the new triple storage (TS) set. STUDY DESIGN AND METHODS: The objective of this study was to evaluate the TS set on three different preparation platforms compared with the large-volume (LV) set, as control. PLT in vitro metabolic and activation parameters were studied over 7 days. RESULTS: Several statistical differences are observed between the two sets, particularly for pH, oxygen pressure (pO2 ), carbonic gaz pressure (pCO2 ), and bicarbonate. The three different preparation techniques influence PLT parameters, and the difference is statistically significant for all the studied parameters, except for pCO2 . The TS set has the advantage of shorter compound adsorption device time, higher PLT recoveries, and less PLT activation. CONCLUSION: Results from the measured metabolic parameters and PLT variables obtained from PCs treated by LV and TS sets indicated good PLT function preservation up to 7 days of storage. The in vitro assessment results demonstrated acceptable PLT function for transfusion.


Asunto(s)
Plaquetas/citología , Conservación de la Sangre/métodos , Desinfección/métodos , Ficusina/farmacología , Rayos Ultravioleta , Plaquetas/microbiología , Femenino , Humanos , Masculino , Factores de Tiempo
3.
Biochem Pharmacol ; 70(5): 714-24, 2005 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-15978547

RESUMEN

The CD94/NKG2A heterodimer is a natural killer receptor (NKR), which inhibits cell-mediated cytotoxicity upon interaction with MHC class I gene products. It is expressed by NK cells and by a small fraction of activated T cells, predominantly of CD8+ phenotype. Abnormal upregulation of the CD94/NKG2A inhibitory NKR on cytotoxic T cells (CTLs) could be responsible for a failure of immunosurveillance in cancer or HIV infection. In an attempt to identify the mechanisms leading to inhibitory NKR upregulation on T cells, we analyzed the expression of the CD94/NKG2A heterodimer on human CTLs activated with anti-CD3 mAb in the presence of PGE2 or with 8-CPT-cAMP, an analogue of cyclic AMP. As previously described, anti-CD3 mAb-mediated activation induced the expression of CD94/NKG2A on a small fraction of CD8+ T cells. Interestingly, when low concentrations of PGE2 or 8-CPT-cAMP were present during the culture, the proportion of CD8+ T cells expressing CD94/NKG2A was two- to five-fold higher. This upregulation was partially prevented by PKA inhibitors, such as KT5720 and Rp-8-Br-cAMP (type I selective). We also report that cAMP induces upregulation of NKG2A at the mRNA level. We further demonstrated that cross-linking of CD94 on CD8+ T cells expressing the CD94/NKG2A heterodimer inhibits their cytotoxic activity in a bispecific antibody redirected lysis assay. Our findings clearly demonstrate that the PGE2/cAMP/PKA type I axis is involved in the expression of CD94/NKG2A receptor on human CD8+ T lymphocytes.


Asunto(s)
Antígenos CD/biosíntesis , Linfocitos T CD8-positivos/metabolismo , Proteínas Quinasas Dependientes de AMP Cíclico/fisiología , Dinoprostona/farmacología , Lectinas Tipo C/biosíntesis , Receptores Inmunológicos/biosíntesis , Antígenos CD/genética , Antígenos CD/fisiología , AMP Cíclico/análogos & derivados , AMP Cíclico/farmacología , AMP Cíclico/fisiología , Humanos , Lectinas Tipo C/genética , Lectinas Tipo C/fisiología , Subfamília C de Receptores Similares a Lectina de Células NK , Subfamília D de Receptores Similares a Lectina de las Células NK , ARN Mensajero/análisis , Receptores Inmunológicos/genética , Receptores Inmunológicos/fisiología , Receptores de Células Asesinas Naturales , Tionucleótidos/farmacología
4.
Blood Transfus ; 12(2): 226-31, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24931842

RESUMEN

BACKGROUND: The quality of fresh-frozen plasma is affected by different factors. Factor VIII is sensitive to blood component storage processes and storage as well as pathogen-reduction technologies. The level of fibrinogen in plasma is not affected by the collection processes but it is affected by preparation and pathogen-reduction technologies. MATERIALS AND METHODS: The quality of plasma from whole blood and apheresis donations harvested at different times and treated with a pathogen-reduction technique, methylene blue/light, was investigated, considering, in particular, fibrinogen and factor VIII levels and recovery. RESULTS: The mean factor VIII level after methylene blue treatment exceeded 0.5 IU/mL in all series. Factor VIII recovery varied between 78% and 89% in different series. The recovery of factor VIII was dependent on plasma source as opposed to treatment time. The interaction between the two factors was statistically significant. Mean levels of fibrinogen after methylene blue/light treatment exceeded 200 mg/dL in all arms. The level of fibrinogen after treatment correlated strongly with the level before treatment. There was a negative correlation between fibrinogen level before treatment and recovery. Pearson's correlation coefficient between factor VIII recovery and fibrinogen recovery was 0.58. DISCUSSION: These results show a difference in recovery of factor VIII and fibrinogen correlated with plasma source. The recovery of both factor VIII and fibrinogen was higher in whole blood plasma than in apheresis plasma. Factor VIII and fibrinogen recovery did not appear to be correlated.


Asunto(s)
Conservación de la Sangre , Inhibidores Enzimáticos/farmacología , Factor VIII/análisis , Fibrinógeno/análisis , Azul de Metileno/farmacología , Plasma/química , Eliminación de Componentes Sanguíneos/métodos , Femenino , Humanos , Masculino , Plasma/metabolismo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA