Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Syst Rev ; 13(1): 177, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38992684

RESUMEN

OBJECTIVES: In a time of exponential growth of new evidence supporting clinical decision-making, combined with a labor-intensive process of selecting this evidence, methods are needed to speed up current processes to keep medical guidelines up-to-date. This study evaluated the performance and feasibility of active learning to support the selection of relevant publications within medical guideline development and to study the role of noisy labels. DESIGN: We used a mixed-methods design. Two independent clinicians' manual process of literature selection was evaluated for 14 searches. This was followed by a series of simulations investigating the performance of random reading versus using screening prioritization based on active learning. We identified hard-to-find papers and checked the labels in a reflective dialogue. MAIN OUTCOME MEASURES: Inter-rater reliability was assessed using Cohen's Kappa (ĸ). To evaluate the performance of active learning, we used the Work Saved over Sampling at 95% recall (WSS@95) and percentage Relevant Records Found at reading only 10% of the total number of records (RRF@10). We used the average time to discovery (ATD) to detect records with potentially noisy labels. Finally, the accuracy of labeling was discussed in a reflective dialogue with guideline developers. RESULTS: Mean ĸ for manual title-abstract selection by clinicians was 0.50 and varied between - 0.01 and 0.87 based on 5.021 abstracts. WSS@95 ranged from 50.15% (SD = 17.7) based on selection by clinicians to 69.24% (SD = 11.5) based on the selection by research methodologist up to 75.76% (SD = 12.2) based on the final full-text inclusion. A similar pattern was seen for RRF@10, ranging from 48.31% (SD = 23.3) to 62.8% (SD = 21.20) and 65.58% (SD = 23.25). The performance of active learning deteriorates with higher noise. Compared with the final full-text selection, the selection made by clinicians or research methodologists deteriorated WSS@95 by 25.61% and 6.25%, respectively. CONCLUSION: While active machine learning tools can accelerate the process of literature screening within guideline development, they can only work as well as the input given by human raters. Noisy labels make noisy machine learning.


Asunto(s)
Aprendizaje Automático , Guías de Práctica Clínica como Asunto , Humanos , Reproducibilidad de los Resultados , Toma de Decisiones Clínicas , Medicina Basada en la Evidencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA