Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Pharm Stat ; 11(6): 449-55, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22997130

RESUMEN

Multivariate longitudinal or clustered data are commonly encountered in clinical trials and toxicological studies. Typically, there is no single standard endpoint to assess the toxicity or efficacy of the compound of interest, but co-primary endpoints are available to assess the toxic effects or the working of the compound. Modeling the responses jointly is thus appealing to draw overall inferences using all responses and to capture the association among the responses. Non-Gaussian outcomes are often modeled univariately using exponential family models. To accommodate both the overdispersion and hierarchical structure in the data, Molenberghs et al. A family of generalized linear models for repeated measures with normal and conjugate random effects. Statistical Science 2010; 25:325-347 proposed using two separate sets of random effects. This papers considers a model for multivariate data with hierarchically clustered and overdispersed non-Gaussian data. Gamma random effect for the over-dispersion and normal random effects for the clustering in the data are being used. The two outcomes are jointly analyzed by assuming that the normal random effects for both endpoints are correlated. The association structure between the response is analytically derived. The fit of the joint model to data from a so-called comet assay are compared with the univariate analysis of the two outcomes.


Asunto(s)
Ensayos Clínicos como Asunto/métodos , Ensayo Cometa/métodos , Modelos Estadísticos , Evaluación de Resultado en la Atención de Salud/métodos , Animales , Análisis por Conglomerados , Interpretación Estadística de Datos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos , Determinación de Punto Final , Humanos , Modelos Lineales , Estudios Longitudinales , Análisis Multivariante
2.
Artículo en Inglés | MEDLINE | ID: mdl-35914859

RESUMEN

It is often assumed that genotoxic substances will be detected more easily by using in vitro rather than in vivo genotoxicity tests since higher concentrations, more cytotoxicity and static exposures can be achieved. However, there is a paucity of data demonstrating whether genotoxic substances are detected at lower concentrations in cell culture in vitro than can be reached in the blood of animals treated in vivo. To investigate this issue, we compared the lowest concentration required for induction of chromosomal damage in vitro (lowest observed effective concentration, or LOEC) with the concentration of the test substance in blood at the lowest dose required for biologically relevant induction of micronuclei in vivo (lowest observed effective dose, or LOED). In total, 83 substances were found for which the LOED could be identified or estimated, where concentrations in blood and micronucleus data were available via the same route of administration in the same species, and in vitro chromosomal damage data were available. 39.8 % of substances were positive in vivo at blood concentrations that were lower than the LOEC in vitro, 22.9 % were positive at similar concentrations, and 37.3 % of substances were positive in vivo at higher concentrations. Distribution analysis showed a very wide scatter of > 6 orders of magnitude across these 3 categories. When mode of action was evaluated, the distribution of clastogens and aneugens across the 3 categories was very similar. Thus, the ability to detect induction of micronuclei in bone marrow in vivo regardless of the mechanism for micronucleus induction, is clearly not solely determined by the concentration of test substance which induced chromosomal damage in vitro.


Asunto(s)
Aneugénicos , Mutágenos , Animales , Medios de Cultivo , Daño del ADN , Pruebas de Micronúcleos , Mutágenos/toxicidad
3.
Mutat Res ; 702(1): 40-69, 2010 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-20656055

RESUMEN

A collaborative trial was conducted to evaluate the possibility of integrating the rat-liver Comet assay into repeat-dose toxicity studies. Fourteen laboratories from Europe, Japan and the USA tested fifteen chemicals. Two chemicals had been previously shown to induce micronuclei in an acute protocol, but were found negative in a 4-week Micronucleus (MN) Assay (benzo[a]pyrene and 1,2-dimethylhydrazine; Hamada et al., 2001); four genotoxic rat-liver carcinogens that were negative in the MN assay in bone marrow or blood (2,6-dinitrotoluene, dimethylnitrosamine, 1,2-dibromomethane, and 2-amino-3-methylimidazo[4,5-f]quinoline); three compounds used in the ongoing JaCVAM (Japanese Center for the Validation of Alternative Methods) validation study of the acute liver Comet assay (2,4-diaminotoluene, 2,6-diaminotoluene and acrylamide); three pharmaceutical-like compounds (chlordiazepoxide, pyrimethamine and gemifloxacin), and three non-genotoxic rodent liver carcinogens (methapyrilene, clofibrate and phenobarbital). Male rats received oral administrations of the test compounds, daily for two or four weeks. The top dose was meant to be the highest dose producing clinical signs or histopathological effects without causing mortality, i.e. the 28-day maximum tolerated dose. The liver Comet assay was performed according to published recommendations and following the protocol for the ongoing JaCVAM validation trial. Laboratories provided liver Comet assay data obtained at the end of the long-term (2- or 4-week) studies together with an evaluation of liver histology. Most of the test compounds were also investigated in the liver Comet assay after short-term (1-3 daily) administration to compare the sensitivity of the two study designs. MN analyses were conducted in bone marrow or peripheral blood for most of the compounds to determine whether the liver Comet assay could complement the MN assay for the detection of genotoxins after long-term treatment. Most of the liver genotoxins were positive and the three non-genotoxic carcinogens gave negative result in the liver Comet assay after long-term administration. There was a high concordance between short- and long-term Comet assay results. Most compounds when tested up to the maximum tolerated dose were correctly detected in both short- and long-term studies. Discrepant results were obtained with 2,6 diaminotoluene (negative in the short-term, but positive in the long-term study), phenobarbital (positive in the short-term, but negative in the long-term study) and gemifloxacin (positive in the short-term, but negative in the long-term study). The overall results indicate that the liver Comet assay can be integrated within repeat-dose toxicity studies and efficiently complements the MN assay in detecting genotoxins. Practical aspects of integrating genotoxicity endpoints into repeat-dose studies were evaluated, e.g. by investigating the effect of blood sampling, as typically performed during toxicity studies, on the Comet and MN assays. The bleeding protocols used here did not affect the conclusions of the Comet assay or of the MN assays in blood and bone marrow. Although bleeding generally increased reticulocyte frequencies, the sensitivity of the response in the MN assay was not altered. These findings indicate that all animals in a toxicity study (main-study animals as well as toxicokinetic (TK) satellite animals) could be used for evaluating genotoxicity. However, possible logistical issues with scheduling of the necropsies and the need to conduct electrophoresis promptly after tissue sampling suggest that the use of TK animals could be simpler. The data so far do not indicate that liver proliferation or toxicity confound the results of the liver Comet assay. As was also true for other genotoxicity assays, criteria for evaluation of Comet assay results and statistical analyses differed among laboratories. Whereas comprehensive advice on statistical analysis is available in the literature, agreement is needed on applying consistent criteria.


Asunto(s)
Mutágenos/toxicidad , Animales , Carcinógenos/toxicidad , Ensayo Cometa/métodos , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Hígado/efectos de los fármacos , Masculino , Pruebas de Micronúcleos/métodos , Ratas , Ratas Wistar , Pruebas de Toxicidad
4.
Environ Mol Mutagen ; 61(5): 508-525, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32187737

RESUMEN

Acetaminophen, a nonmutagenic compound as previously concluded from bacteria, in vitro mammalian cell, and in vivo transgenic rat assays, presented a good profile as a nonmutagenic reference compound for use in the international multilaboratory Pig-a assay validation. Acetaminophen was administered at 250, 500, 1,000, and 2,000 mg·kg-1 ·day-1 to male Sprague Dawley rats once daily in 3 studies (3 days, 2 weeks, and 1 month with a 1-month recovery group). The 3-Day and 1-Month Studies included assessments of the micronucleus endpoint in peripheral blood erythrocytes and the comet endpoint in liver cells and peripheral blood cells in addition to the Pig-a assay; appropriate positive controls were included for each assay. Within these studies, potential toxicity of acetaminophen was evaluated and confirmed by inclusion of liver damage biomarkers and histopathology. Blood was sampled pre-treatment and at multiple time points up to Day 57. Pig-a mutant frequencies were determined in total red blood cells (RBCs) and reticulocytes (RETs) as CD59-negative RBC and CD59-negative RET frequencies, respectively. No increases in DNA damage as indicated through Pig-a, micronucleus, or comet endpoints were seen in treated rats. All positive controls responded as appropriate. Data from this series of studies demonstrate that acetaminophen is not mutagenic in the rat Pig-a model. These data are consistent with multiple studies in other nonclinical models, which have shown that acetaminophen is not mutagenic. At 1,000 mg·kg-1 ·day-1 , Cmax values of acetaminophen on Day 28 were 153,600 ng/ml and 131,500 ng/ml after single and repeat dosing, respectively, which were multiples over that of clinical therapeutic exposures (2.6-6.1 fold for single doses of 4,000 mg and 1,000 mg, respectively, and 11.5 fold for multiple dose of 4,000 mg) (FDA 2002). Data generated were of high quality and valid for contribution to the international multilaboratory validation of the in vivo Rat Pig-a Mutation Assay.


Asunto(s)
Acetaminofén/farmacología , Bioensayo , Internacionalidad , Laboratorios , Pruebas de Mutagenicidad , Animales , Ensayo Cometa , Masculino , Pruebas de Micronúcleos , Mutágenos/toxicidad , Ratas Sprague-Dawley , Reproducibilidad de los Resultados
5.
Artículo en Inglés | MEDLINE | ID: mdl-32087853

RESUMEN

The International Workshop on Genotoxicity Testing (IWGT) meets every four years to obtain consensus on unresolved issues associated with genotoxicity testing. At the 2017 IWGT meeting in Tokyo, four sub-groups addressed issues associated with the Organization for Economic Cooperation and Development (OECD) Test Guideline TG471, which describes the use of bacterial reverse-mutation tests. The strains sub-group analyzed test data from >10,000 chemicals, tested additional chemicals, and concluded that some strains listed in TG471 are unnecessary because they detected fewer mutagens than other strains that the guideline describes as equivalent. Thus, they concluded that a smaller panel of strains would suffice to detect most mutagens. The laboratory proficiency sub-group recommended (a) establishing strain cell banks, (b) developing bacterial growth protocols that optimize assay sensitivity, and (c) testing "proficiency compounds" to gain assay experience and establish historical positive and control databases. The sub-group on criteria for assay evaluation recommended that laboratories (a) track positive and negative control data; (b) develop acceptability criteria for positive and negative controls; (c) optimize dose-spacing and the number of analyzable doses when there is evidence of toxicity; (d) use a combination of three criteria to evaluate results: a dose-related increase in revertants, a clear increase in revertants in at least one dose relative to the concurrent negative control, and at least one dose that produced an increase in revertants above control limits established by the laboratory from historical negative controls; and (e) establish experimental designs to resolve unclear results. The in silico sub-group summarized in silico utility as a tool in genotoxicity assessment but made no specific recommendations for TG471. Thus, the workgroup identified issues that could be addressed if TG471 is revised. The companion papers (a) provide evidence-based approaches, (b) recommend priorities, and (c) give examples of clearly defined terms to support revision of TG471.


Asunto(s)
Escherichia coli/efectos de los fármacos , Mutagénesis , Pruebas de Mutagenicidad/normas , Mutágenos/toxicidad , Salmonella typhimurium/efectos de los fármacos , Animales , Bancos de Muestras Biológicas/organización & administración , Bases de Datos de Compuestos Químicos/provisión & distribución , Escherichia coli/genética , Guías como Asunto , Humanos , Cooperación Internacional , Mutágenos/clasificación , Salmonella typhimurium/genética , Tokio
6.
PLoS Negl Trop Dis ; 13(1): e0007026, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30650076

RESUMEN

BACKGROUND: Flubendazole, originally developed to treat infections with intestinal nematodes, has been shown to be efficacious in animal models of filarial infections. For treatment of filarial nematodes, systemic exposure is needed. For this purpose, an orally bioavailable amorphous solid dispersion (ASD) formulation of flubendazole was developed. As this formulation results in improved systemic absorption, the pharmacokinetic and toxicological profile of the flubendazole ASD formulation have been assessed to ensure human safety before clinical trials could be initiated. METHODS & FINDINGS: Safety pharmacology, toxicity and genotoxicity studies have been conducted with the flubendazole ASD formulation. In animals, flubendazole has good oral bioavailability from an ASD formulation ranging from 15% in dogs, 27% in rats to more than 100% in jirds. In in vivo toxicity studies with the ASD formulation, high systemic exposure to flubendazole and its main metabolites was reached. Flubendazole, up to high peak plasma concentrations, does not induce Cmax related effects in CNS or cardiovascular system. In repeated dose toxicity studies in rats and dogs, flubendazole-induced changes were observed in haematological, lymphoid and gastrointestinal systems and in testes. In dogs, the liver was an additional target organ. Upon treatment cessation, at least partial recovery was observed for these changes in dogs. In rats, the No Observed Adverse Effect Level (NOAEL) was 5 mg (as base)/kg body weight/day (mg eq./kg/day) in males and 2.5 mg eq./kg/day in females. In dogs, the NOAEL was lower than 20 mg eq./kg/day. Regarding genotoxicity, flubendazole was negative in the Ames test, but positive in the in vivo micronucleus test. CONCLUSIONS: Based on these results, in combination with previously described genotoxicity and reproductive toxicity data and the outcome of the preclinical efficacy studies, it was concluded that no flubendazole treatment regimen can be selected that would provide efficacy in humans at safe exposure.


Asunto(s)
Antinematodos/efectos adversos , Antinematodos/farmacocinética , Mebendazol/análogos & derivados , Pruebas de Mutagenicidad , Administración Oral , Animales , Antinematodos/administración & dosificación , Perros , Evaluación Preclínica de Medicamentos , Femenino , Gerbillinae , Masculino , Mebendazol/administración & dosificación , Mebendazol/efectos adversos , Mebendazol/farmacocinética , Ratas Sprague-Dawley
7.
Artículo en Inglés | MEDLINE | ID: mdl-31708073

RESUMEN

A committee was constituted within the International Workshop on Genetic Toxicology Testing (IWGT) to evaluate the current criteria for a valid Ames test and to provide recommendations for interpretation of test results. Currently, determination of a positive vs. a negative result is made by applying various data evaluation procedures for comparing dosed plates with the concurrent solvent control plates. These evaluation procedures include a requirement for a specific fold increase (2- or 3-fold, specific to the bacterial strain), formal statistical procedures, or subjective (expert judgment) evaluation. After extensive discussion, the workgroup was not able to reach consensus recommendations in favor of any of these procedures. There was a consensus that combining additional evaluation criteria to the comparison between dosed plates and the concurrent solvent control plates improves test interpretation. The workgroup recommended using these additional criteria because the induction of mutations is a continuum of responses and there is no biological relevance to a strict dividing line between a positive (mutagenic) and not-positive (nonmutagenic) response. The most useful additional criteria identified were a concentration-response relationship and consideration of a possible increase above the concurrent control in the context of the laboratory's historical solvent control values for the particular tester strain. The workgroup also emphasized the need for additional testing to resolve weak or inconclusive responses, usually with altered experimental conditions chosen based on the initial results. Use of these multiple criteria allowed the workgroup to reach consensus on definitions of "clear positive" and "clear negative" responses which would not require a repeat test for clarification. The workgroup also reached consensus on recommendations to compare the responses of concurrent positive and negative controls to historical control distributions for assay acceptability, and the use of control charts to determine the validity of the individual test.


Asunto(s)
Pruebas de Mutagenicidad , Salmonella typhimurium/genética , Animales , Estudios de Evaluación como Asunto , Humanos
8.
Toxicol In Vitro ; 22(7): 1789-96, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18672049

RESUMEN

In order to support drug research in the selection process for non-embryotoxic pharmaceutical compounds, a screening method for embryotoxicity is needed. The murine embryonic stem cell test (EST) is a validated in vitro test based on two permanent mouse cell lines and delivering results in 10-days. Implementation of this test within our laboratory, revealed variability in the differentiation potential of the embryonic stem cells and, as a consequence, a lot of assays needed to be rejected due the fact the acceptance criteria were not reached. In order to gain a better yield of contracting myocardial cells, we used (1) a stringent control of the cell growth during subcultivation and a standardised hanging drop culture method and (2) a non-enzymatic cell harvest instead of a trypsin/EDTA cell harvest. Implementing of these cell culture modifications resulted in a decreased variability in the size of embryonic bodies, an increase of the number of acceptable tests and a significant increase of the differentiation potential of embryonic cells into strong beating myocardium, which made scoring less time consuming. Testing of 6 reference compounds in the optimized EST showed that the cell culture modifications did not changed the in vitro classification.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Diferenciación Celular/efectos de los fármacos , Células Madre Embrionarias/efectos de los fármacos , Pruebas de Toxicidad/métodos , Animales , Células 3T3 BALB , Ácido Edético/metabolismo , Células Madre Embrionarias/metabolismo , Ratones , Miocardio/citología , Tripsina/metabolismo
9.
Environ Mol Mutagen ; 46(1): 30-42, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15880423

RESUMEN

According to the current Organization of Economic Cooperation and Development (OECD) and International Committee on Harmonization (ICH) guidelines for the mammalian erythrocyte micronucleus (MN) test, analysis of peripheral blood reticulocytes (RETs) for the presence of micronuclei can be performed using flow cytometry. The MicroFlow PLUS method (Litron Laboratories, Rochester, NY) for MN analysis by flow cytometry is based on the binding of FITC-labeled antibodies to the CD71 transferrin receptor of immature RETs, on parallel RNA degradation, and on propidium iodide staining of DNA present as micronuclei. The objective of this study was to assess the sensitivity of this flow cytometry method to detect time- and dose-dependent induction of micronuclei in mouse peripheral blood RETs after treatment with nine chemical agents. Five known clastogens, two known aneugens, and two compounds previously reported to be inactive in the mouse bone marrow MN test were evaluated at three dose levels. Multiple blood sampling of the same animal before and at two time points after treatment was conducted. All known mutagens produced a dose-dependent increase in micronucleated reticulocytes (MN-RETs); the compounds previously shown to be inactive in the in vivo MN test were also negative using the present methodology. The highest frequency of MN-RETs was observed at 48 hr after treatment, except for 5-fluorouracil, which had its peak response at 72 hr. The results indicate that micronuclei can be measured by multiple blood sampling of the same animal before and after treatment without altering the sensitivity of the assay. The results confirm that the flow cytometric assessment of MN-RETs in mouse peripheral blood using MicroFlow PLUS is a sensitive method with high analysis throughput, and robust quality control.


Asunto(s)
Recolección de Muestras de Sangre/métodos , Citometría de Flujo , Micronúcleos con Defecto Cromosómico/inducido químicamente , Mutágenos/toxicidad , Reticulocitos/efectos de los fármacos , Animales , Relación Dosis-Respuesta a Droga , Masculino , Ratones , Pruebas de Micronúcleos/métodos , Reticulocitos/metabolismo , Factores de Tiempo
10.
Environ Mol Mutagen ; 45(1): 44-55, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15605355

RESUMEN

An interlaboratory study was performed to validate an anti-CD71/flow cytometry-based technique for enumerating micronucleated reticulocytes (MN-RETs) in mouse peripheral blood. These experiments were designed to address International Workshop on Genotoxicity Test Procedures validation criteria by evaluating the degree of correspondence between MN-RET measurements generated by flow cytometry (FCM) with those obtained using traditional microscopy-based methods. In addition to these cross-methods data, flow cytometric MN-RET measurements for each blood sample were performed at two separate sites in order to evaluate the reproducibility of data between laboratories. In these studies, groups of male CD-1 mice were treated with vehicle (saline or vegetable oil), a negative control (saline or vegetable oil), or four dose levels of five known genotoxicants (clastogens: cyclophosphamide, benzo[a]pyrene, 5-fluorouracil, methotrexate; aneugen: vincristine sulfate). Exposure occurred on 3 consecutive days via intraperitoneal injection, and blood samples were obtained approximately 24 hr after the final treatment. MN-RET frequencies were determined for each sample based on the analysis of 2,000 (microscopy) and 20,000 (FCM) reticulocytes. Regardless of the method utilized, each genotoxic agent was observed to cause statistically significant increases in the frequency of MN-RETs, and each response occurred in a dose-dependent manner. Spearman's correlation coefficient (rs) for FCM versus microscopy-based MN-RET measurements (nine experiments, 252 paired measurements) was 0.740, indicating a high degree of correspondence between methods. The rs value for all flow cytometric MN-RET measurements performed at the two independent sites was 0.857 (n = 248), suggesting that the automated method is highly transferable between laboratories. Additionally, the flow cytometric system offered advantages relative to microscopy-based scoring, including a greater number of cells analyzed, much faster analysis times, and a greater degree of objectivity. Collectively, data presented in this report suggest that the overall performance of mouse peripheral blood micronucleus tests is enhanced by the use of the flow cytometric scoring procedure.


Asunto(s)
Citometría de Flujo/métodos , Pruebas de Micronúcleos/métodos , Reticulocitos , Animales , Antígenos CD , Antígenos de Diferenciación de Linfocitos B , Benzo(a)pireno/toxicidad , Ciclofosfamida/toxicidad , Relación Dosis-Respuesta a Droga , Masculino , Metotrexato/toxicidad , Ratones , Mutágenos/toxicidad , Receptores de Transferrina , Vincristina/toxicidad
11.
Mutat Res Genet Toxicol Environ Mutagen ; 786-788: 151-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26212306

RESUMEN

As part of the Japanese Center for the Validation of Alternative Methods (JaCVAM)-initiated international validation study of in vivo rat alkaline comet assay (comet assay), p-phenylenediamine dihydrochloride (PPD), o-phenylphenol sodium salt (OPP), and 2,4-diaminotoluene (2,4-DAT), were analyzed in this laboratory as coded test chemicals. Male Sprague-Dawley rats (7-9 weeks of age) were given three oral doses of the test compounds, 24 and 21 h apart and liver and stomach were sampled 3h after the final dose administration. Under the conditions of the test, no increases in DNA damage were observed in liver and stomach with PPD and OPP up to 100 and 1000 mg/kg/day, respectively. 2,4-DAT, a known genotoxic carcinogen, induced a weak but reproducible, dose-related and statistically significant increase in DNA damage in liver cells while no increases were observed in stomach cells.


Asunto(s)
Compuestos de Bifenilo/toxicidad , Ensayo Cometa/métodos , Fenilendiaminas/toxicidad , Administración Oral , Animales , Carcinógenos/toxicidad , Daño del ADN/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Hígado/efectos de los fármacos , Masculino , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Estómago/efectos de los fármacos
12.
Artículo en Inglés | MEDLINE | ID: mdl-25435358

RESUMEN

In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by the ICH S2(R1) guideline. This paper summarizes a survey suggested by the Safety Working Party of European Medicines Agency (EMA), and conducted by the European Federation of Pharmaceutical Industries and Associations (EFPIA) to investigate the experience among European pharmaceutical companies by conducting the in vivo comet assay for regulatory purpose. A special focus was given on the typology of the obtained results and to identify potential difficulties encountered with the interpretation of study data. The participating companies reported a total of 147 studies (conducted in-house or outsourced) and shared the conclusion on the comet assay response for 136 studies. Most of the studies were negative (118/136). Only about 10% (14/136 studies) of the comet assays showed a positive response. None of the positive comet assay results were clearly associated with organ toxicity indicating that the positive responses are not due to cytotoxic effects of the compound in the tissue examined. The number of comet assays with an equivocal or inconclusive response was rare, respectively <1% (1/147 studies) and 2% (3/147 studies). In case additional information (e.g. repeat assay, organ toxicity, metabolism, tissue exposure) would have been available for evaluation, a final conclusion could most probably have been drawn for most or all of these studies. All (46) negative in vivo comet assays submitted alongside with a negative in vivo micronucleus assay were accepted by the regulatory authorities to mitigate a positive in vitro mammalian cell assay following the current ICH S2 guidance. The survey results demonstrate the robustness of the comet assay and the regulatory acceptance of the current ICH S2 guidance.


Asunto(s)
Ensayo Cometa/métodos , Recolección de Datos , Animales , Ensayo Cometa/estadística & datos numéricos , Daño del ADN , Industria Farmacéutica/organización & administración , Industria Farmacéutica/estadística & datos numéricos , Europa (Continente) , Guías como Asunto , Pruebas de Micronúcleos/métodos , Roedores/genética
13.
Environ Mol Mutagen ; 52(9): 690-8, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21910140

RESUMEN

A collaborative international trial was conducted to evaluate the reproducibility and transferability of an in vivo mutation assay based on the enumeration of CD59-negative rat erythrocytes, a phenotype that is indicative of Pig-a gene mutation. Fourteen laboratories participated in this study, where anti-CD59-PE, SYTO 13 dye, and flow cytometry were used to determine the frequency of CD59-negative erythrocytes (RBC(CD59-)) and CD59-negative reticulocytes (RET(CD59-)). To provide samples with a range of mutant phenotype cell frequencies, male rats were exposed to N-ethyl-N-nitrosourea (ENU) via oral gavage for three consecutive days (Days 1-3). Each laboratory studied 0, 20, and 40 mg ENU/kg/day (n = 5 per group). Three sites also evaluated 4 mg/kg/day. At a minimum, blood samples were collected three times: predosing and on Days 15 and 30. Blood samples were processed according to a standardized sample processing and data acquisition protocol, and three endpoints were measured: %reticulocytes, frequency of RET(CD59-) , and frequency of RBC(CD59-) . The methodology was found to be reproducible, as the analysis of technical replicates resulted in experimental coefficients of variation that approached theoretical values. Good transferability was evident from the similar kinetics and magnitude of the dose-related responses that were observed among different laboratories. Concordance correlation coefficients showed a high level of agreement between the reference site and the test sites (range: 0.87-0.99). Collectively, these data demonstrate that with adequate training of personnel, flow cytometric analysis is capable of reliably enumerating mutant phenotype erythrocytes, thereby providing a robust in vivo mutation assay that is readily transferable across laboratories.


Asunto(s)
Citometría de Flujo , Laboratorios , Proteínas de la Membrana/genética , Pruebas de Mutagenicidad , Mutación , Animales , Antígenos CD59/genética , Calibración , Interpretación Estadística de Datos , Determinación de Punto Final , Eritrocitos/efectos de los fármacos , Eritrocitos/metabolismo , Eritrocitos/ultraestructura , Etilnitrosourea/toxicidad , Citometría de Flujo/métodos , Citometría de Flujo/normas , Cooperación Internacional , Laboratorios/normas , Pruebas de Mutagenicidad/métodos , Pruebas de Mutagenicidad/normas , Mutágenos/toxicidad , Ratas , Ratas Endogámicas F344 , Ratas Sprague-Dawley , Ratas Wistar , Estándares de Referencia , Reproducibilidad de los Resultados , Reticulocitos/efectos de los fármacos , Reticulocitos/metabolismo , Reticulocitos/ultraestructura , Medición de Riesgo , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA