Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 882
Filtrar
Más filtros

Intervalo de año de publicación
1.
Dev Biol ; 514: 87-98, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38876166

RESUMEN

The heart is the central organ of the circulatory system, and its proper development is vital to maintain human life. As fetal heart development is complex and poorly understood, we use single-cell RNA sequencing to profile the gene expression landscapes of human fetal hearts from the four-time points: 8, 10, 11, 17 gestational weeks (GW8, GW10, GW11, GW17), and identified 11 major types of cells: erythroid cells, fibroblasts, heart endothelial cells, ventricular cardiomyocytes, atrial cardiomyocytes, macrophage, DCs, smooth muscle, pericytes, neural cells, schwann cells. In addition, we identified a series of differentially expressed genes and signaling pathways in each cell type between different gestational weeks. Notably, we found that ANNEXIN, MIF, PTN, GRN signalling pathways were simple and fewer intercellular connections in GW8, however, they were significantly more complex and had more intercellular communication in GW10, GW11, and GW17. Notably, the interaction strength of OSM signalling pathways was gradually decreased during this period of time (from GW8 to GW17). Together, in this study, we presented a comprehensive and clear description of the differentiation processes of all the main cell types in the human fetal hearts, which may provide information and reference data for heart regeneration and heart disease treatment.


Asunto(s)
Comunicación Celular , Análisis de la Célula Individual , Transcriptoma , Humanos , Comunicación Celular/genética , Transcriptoma/genética , Análisis de Secuencia de ARN , Corazón Fetal/metabolismo , Corazón Fetal/embriología , Regulación del Desarrollo de la Expresión Génica , Miocitos Cardíacos/metabolismo , Miocitos Cardíacos/citología , Transducción de Señal/genética , Diferenciación Celular/genética , Perfilación de la Expresión Génica , Edad Gestacional
2.
J Physiol ; 602(12): 2697-2715, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38743350

RESUMEN

Fetuses affected by intrauterine growth restriction have an increased risk of developing heart disease and failure in adulthood. Compared with controls, late gestation intrauterine growth-restricted (IUGR) fetal sheep have fewer binucleated cardiomyocytes, reflecting a more immature heart, which may reduce mitochondrial capacity to oxidize substrates. We hypothesized that the late gestation IUGR fetal heart has a lower capacity for mitochondrial oxidative phosphorylation. Left (LV) and right (RV) ventricles from IUGR and control (CON) fetal sheep at 90% gestation were harvested. Mitochondrial respiration (states 1-3, LeakOmy, and maximal respiration) in response to carbohydrates and lipids, citrate synthase (CS) activity, protein expression levels of mitochondrial oxidative phosphorylation complexes (CI-CV), and mRNA expression levels of mitochondrial biosynthesis regulators were measured. The carbohydrate and lipid state 3 respiration rates were lower in IUGR than CON, and CS activity was lower in IUGR LV than CON LV. However, relative CII and CV protein levels were higher in IUGR than CON; CV expression level was higher in IUGR than CON. Genes involved in lipid metabolism had lower expression in IUGR than CON. In addition, the LV and RV demonstrated distinct differences in oxygen flux and gene expression levels, which were independent from CON and IUGR status. Low mitochondrial respiration and CS activity in the IUGR heart compared with CON are consistent with delayed cardiomyocyte maturation, and CII and CV protein expression levels may be upregulated to support ATP production. These insights will provide a better understanding of fetal heart development in an adverse in utero environment. KEY POINTS: Growth-restricted fetuses have a higher risk of developing and dying from cardiovascular diseases in adulthood. Mitochondria are the main supplier of energy for the heart. As the heart matures, the substrate preference of the mitochondria switches from carbohydrates to lipids. We used a sheep model of intrauterine growth restriction to study the capacity of the mitochondria in the heart to produce energy using either carbohydrate or lipid substrates by measuring how much oxygen was consumed. Our data show that the mitochondria respiration levels in the growth-restricted fetal heart were lower than in the normally growing fetuses, and the expression levels of genes involved in lipid metabolism were also lower. Differences between the right and left ventricles that are independent of the fetal growth restriction condition were identified. These results indicate an impaired metabolic maturation of the growth-restricted fetal heart associated with a decreased capacity to oxidize lipids postnatally.


Asunto(s)
Retardo del Crecimiento Fetal , Corazón Fetal , Mitocondrias Cardíacas , Animales , Retardo del Crecimiento Fetal/metabolismo , Ovinos , Femenino , Mitocondrias Cardíacas/metabolismo , Corazón Fetal/metabolismo , Embarazo , Respiración de la Célula , Fosforilación Oxidativa , Metabolismo de los Lípidos , Citrato (si)-Sintasa/metabolismo
3.
Am J Obstet Gynecol ; 230(4): 454.e1-454.e11, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37778675

RESUMEN

BACKGROUND: Hyperoxygenation has shown promise in improving suspicious fetal heart patterns in women in labor. However, the effect of hyperoxygenation on neonatal outcomes in women in labor with pathologic fetal heart rate tracing has not been studied. OBJECTIVE: This study aimed to evaluate the effect of fractional inspiration of oxygen of 80% compared with fractional inspiration of oxygen of 40% on neonatal outcomes in women with pathologic fetal heart rate tracing. STUDY DESIGN: This randomized, open-label, parallel arm, outcome assessor-blinded clinical trial was conducted in a large tertiary care university hospital. Singleton parturients aged ≥18 years at term gestation in active labor (cervical dilatation of ≥6 cm) with pathologic fetal heart rate tracing were recruited in the study. Pathologic fetal heart rate tracing was defined according to the International Federation of Gynecology and Obstetrics 2015 guidelines. The International Federation of Gynecology and Obstetrics classifies fetal heart rate tracings into 3 categories (normal, suspicious, and pathologic) based on rate, variability, and deceleration. Women in the intervention arm received oxygen at 10 L/min via a nonrebreathing mask, and those in the usual care arm received oxygen at 6 L/min with a simple face mask. Oxygen supplementation was continued until cord clamping. The primary outcome measure was a 5-minute Apgar score. The secondary outcome measures were the proportion of neonatal intensive care unit admission, umbilical cord blood gas variables, level of methyl malondialdehyde in the cord blood, and mode of delivery. RESULTS: Overall, 148 women (74 women in the high fractional inspiration of oxygen arm and 74 in the low fractional inspiration of oxygen arm) with pathologic fetal heart rate tracing were analyzed. The demographic data, obstetrical profiles, and comorbidities were comparable. The median 5-minute Apgar scores were 9 (interquartile range, 8-10) in the hyperoxygenation arm and 9 (interquartile range, 8-10) in the usual care arm (P=.12). Furthermore, the rate of neonatal intensive care unit admission (9.5% vs 12.2%; P=.6) and the requirement of positive pressure ventilation (6.8% vs 8.1%; P=.75) were comparable. Concerning cord blood gas parameters, the hyperoxygenation arm had a significantly higher base deficit in the umbilical vein and lactate level in the umbilical artery. The cesarean delivery rate was significantly lower in women who received hyperoxygenation (4.1% [3/74]) than in women who received normal oxygen supplementation (25.7% [19/74]) (P=.00). In addition, umbilical vein malondialdehyde level in the umbilical vein was lower in the hyperoxygenation group (8.28±4.65 µmol/L) than in the normal oxygen supplementation group (13.44±8.34 µmol/L) (P=.00). CONCLUSION: Hyperoxygenation did not improve the neonatal Apgar score in women with pathologic fetal heart rate tracing. In addition, neonatal intensive care unit admission rate and blood gas parameters remained comparable. Therefore, the results of this trial suggest that a high fractional inspiration of oxygen supplementation confers no benefit on neonatal outcomes in women with pathologic fetal heart rate tracings and normal oxygen saturation.


Asunto(s)
Cardiotocografía , Trabajo de Parto , Embarazo , Recién Nacido , Humanos , Femenino , Adolescente , Adulto , Oxígeno , Arterias Umbilicales , Malondialdehído
4.
Am J Obstet Gynecol ; 230(4): 379.e1-379.e12, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38272284

RESUMEN

BACKGROUND: Intrapartum cardiotocographic monitoring of fetal heart rate by abdominal external ultrasound transducer without simultaneous maternal heart rate recording has been associated with increased risk of early neonatal death and other asphyxia-related neonatal outcomes. It is unclear, however, whether this increase in risk is independently associated with fetal surveillance method or is attributable to other factors. OBJECTIVE: This study aimed to compare different fetal surveillance methods and their association with adverse short- and long-term fetal and neonatal outcomes in a large retrospective cohort of spontaneous term deliveries. STUDY DESIGN: Fetal heart rate and maternal heart rate patterns were recorded by cardiotocography during labor in spontaneous term singleton cephalic vaginal deliveries in the Hospital District of Helsinki and Uusimaa, Finland between October 1, 2005, and September 30, 2023. According to the method of cardiotocography monitoring at birth, the cohort was divided into the following 3 groups: women with ultrasound transducer, women with both ultrasound transducer and maternal heart rate transducer, and women with internal fetal scalp electrode. Umbilical artery pH and base excess values, low 1- and 5-minute Apgar scores, need for intubation and resuscitation, neonatal intensive care unit admission for asphyxia, neonatal encephalopathy, and early neonatal death were used as outcome variables. RESULTS: Among the 213,798 deliveries that met the inclusion criteria, the monitoring type was external ultrasound transducer in 81,559 (38.1%), both external ultrasound transducer and maternal heart rate recording in 62,268 (29.1%), and fetal scalp electrode in 69,971 (32.7%) cases, respectively. The rates of both neonatal encephalopathy (odds ratio, 1.48; 95% confidence interval, 1.08-2.02) and severe acidemia (umbilical artery pH <7.00 and/or umbilical artery base excess ≤-12.0 mmol/L) (odds ratio, 2.03; 95% confidence interval, 1.65-2.50) were higher in fetuses of women with ultrasound transducer alone compared with those of women with concurrent external fetal and maternal heart rate recording. Monitoring with ultrasound transducer alone was also associated with increased risk of neonatal intubation for resuscitation (odds ratio, 1.22; 95% confidence interval, 1.03-1.44). A greater risk of severe neonatal acidemia was observed both in the ultrasound transducer (odds ratio, 2.78; 95% confidence interval, 2.23-3.48) and concurrent ultrasound transducer and maternal heart rate recording (odds ratio, 1.37; 95% confidence interval, 1.05-1.78) groups compared with those monitored with fetal scalp electrodes. No difference in risk of neonatal encephalopathy was found between newborns monitored with concurrent ultrasound transducer and maternal heart rate recording and those monitored with fetal scalp electrodes. CONCLUSION: The use of external ultrasound transducer monitoring of fetal heart rate without simultaneous maternal heart rate recording is associated with higher rates of neonatal encephalopathy and severe neonatal acidemia. We suggest that either external fetal heart rate monitoring with concurrent maternal heart rate recording or internal fetal scalp electrode be used routinely as a fetal surveillance tool in term deliveries.


Asunto(s)
Encefalopatías , Enfermedades del Recién Nacido , Muerte Perinatal , Embarazo , Recién Nacido , Femenino , Humanos , Cardiotocografía/métodos , Estudios Retrospectivos , Asfixia , Frecuencia Cardíaca Fetal/fisiología
5.
Am J Obstet Gynecol ; 230(3S): S807-S840, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38233317

RESUMEN

Clinical chorioamnionitis, the most common infection-related diagnosis in labor and delivery units, is an antecedent of puerperal infection and neonatal sepsis. The condition is suspected when intrapartum fever is associated with two other maternal and fetal signs of local or systemic inflammation (eg, maternal tachycardia, uterine tenderness, maternal leukocytosis, malodorous vaginal discharge or amniotic fluid, and fetal tachycardia). Clinical chorioamnionitis is a syndrome caused by intraamniotic infection, sterile intraamniotic inflammation (inflammation without bacteria), or systemic maternal inflammation induced by epidural analgesia. In cases of uncertainty, a definitive diagnosis can be made by analyzing amniotic fluid with methods to detect bacteria (Gram stain, culture, or microbial nucleic acid) and inflammation (white blood cell count, glucose concentration, interleukin-6, interleukin-8, matrix metalloproteinase-8). The most common microorganisms are Ureaplasma species, and polymicrobial infections occur in 70% of cases. The fetal attack rate is low, and the rate of positive neonatal blood cultures ranges between 0.2% and 4%. Intrapartum antibiotic administration is the standard treatment to reduce neonatal sepsis. Treatment with ampicillin and gentamicin have been recommended by professional societies, although other antibiotic regimens, eg, cephalosporins, have been used. Given the importance of Ureaplasma species as a cause of intraamniotic infection, consideration needs to be given to the administration of antimicrobial agents effective against these microorganisms such as azithromycin or clarithromycin. We have used the combination of ceftriaxone, clarithromycin, and metronidazole, which has been shown to eradicate intraamniotic infection with microbiologic studies. Routine testing of neonates born to affected mothers for genital mycoplasmas could improve the detection of neonatal sepsis. Clinical chorioamnionitis is associated with decreased uterine activity, failure to progress in labor, and postpartum hemorrhage; however, clinical chorioamnionitis by itself is not an indication for cesarean delivery. Oxytocin is often administered for labor augmentation, and it is prudent to have uterotonic agents at hand to manage postpartum hemorrhage. Infants born to mothers with clinical chorioamnionitis near term are at risk for early-onset neonatal sepsis and for long-term disability such as cerebral palsy. A frontier is the noninvasive assessment of amniotic fluid to diagnose intraamniotic inflammation with a transcervical amniotic fluid collector and a rapid bedside test for IL-8 for patients with ruptured membranes. This approach promises to improve diagnostic accuracy and to provide a basis for antimicrobial administration.


Asunto(s)
Corioamnionitis , Sepsis Neonatal , Hemorragia Posparto , Femenino , Recién Nacido , Embarazo , Humanos , Corioamnionitis/diagnóstico , Corioamnionitis/tratamiento farmacológico , Corioamnionitis/etiología , Claritromicina/uso terapéutico , Hemorragia Posparto/tratamiento farmacológico , Sepsis Neonatal/diagnóstico , Sepsis Neonatal/tratamiento farmacológico , Antibacterianos/uso terapéutico , Líquido Amniótico/microbiología , Inflamación/metabolismo , Taquicardia
6.
Circ Res ; 131(2): 151-164, 2022 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-35722872

RESUMEN

BACKGROUND: Establishment of the myocardial wall requires proper growth cues from nonmyocardial tissues. During heart development, the epicardium and epicardium-derived cells instruct myocardial growth by secreting essential factors including FGF (fibroblast growth factor) 9 and IGF (insulin-like growth factor) 2. However, it is poorly understood how the epicardial secreted factors are regulated, in particular by chromatin modifications for myocardial formation. The current study is to investigate whether and how HDAC (histone deacetylase) 3 in the developing epicardium regulates myocardial growth. METHODS: Various cellular and mouse models in conjunction with biochemical and molecular tools were employed to study the role of HDAC3 in the developing epicardium. RESULTS: We deleted Hdac3 in the developing murine epicardium, and mutant hearts showed ventricular myocardial wall hypoplasia with reduction of epicardium-derived cells. The cultured embryonic cardiomyocytes with supernatants from Hdac3 knockout (KO) mouse epicardial cells also showed decreased proliferation. Genome-wide transcriptomic analysis revealed that Fgf9 and Igf2 were significantly downregulated in Hdac3 KO mouse epicardial cells. We further found that Fgf9 and Igf2 expression is dependent on HDAC3 deacetylase activity. The supplementation of FGF9 or IGF2 can rescue the myocardial proliferation defects treated by Hdac3 KO supernatant. Mechanistically, we identified that microRNA (miR)-322 and miR-503 were upregulated in Hdac3 KO mouse epicardial cells and Hdac3 epicardial KO hearts. Overexpression of miR-322 or miR-503 repressed FGF9 and IGF2 expression, while knockdown of miR-322 or miR-503 restored FGF9 and IGF2 expression in Hdac3 KO mouse epicardial cells. CONCLUSIONS: Our findings reveal a critical signaling pathway in which epicardial HDAC3 promotes compact myocardial growth by stimulating FGF9 and IGF2 through repressing miR-322 or miR-503, providing novel insights in elucidating the etiology of congenital heart defects and conceptual strategies to promote myocardial regeneration.


Asunto(s)
Corazón/crecimiento & desarrollo , MicroARNs , Animales , Ratones , MicroARNs/genética , MicroARNs/metabolismo , Miocardio/metabolismo , Miocitos Cardíacos/fisiología , Pericardio/metabolismo , Transducción de Señal
7.
Eur Radiol ; 34(8): 4920-4927, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38195730

RESUMEN

OBJECTIVES: Assessment of myocardial strain by feature tracking magnetic resonance imaging (FT-MRI) in human fetuses with and without congenital heart disease (CHD) using cardiac Doppler ultrasound (DUS) gating. METHODS: A total of 43 human fetuses (gestational age 28-41 weeks) underwent dynamic cardiac MRI at 3 T. Cine balanced steady-state free-precession imaging was performed using fetal cardiac DUS gating. FT-MRI was analyzed using dedicated post-processing software. Endo- and epicardial contours were manually delineated from fetal cardiac 4-chamber views, followed by automated propagation to calculate global longitudinal strain (GLS) of the left (LV) and right ventricle (RV), LV radial strain, and LV strain rate. RESULTS: Strain assessment was successful in 38/43 fetuses (88%); 23 of them had postnatally confirmed diagnosis of CHD (e.g., coarctation, transposition of great arteries) and 15 were heart healthy. Five fetuses were excluded due to reduced image quality. In fetuses with CHD compared to healthy controls, median LV GLS (- 13.2% vs. - 18.9%; p < 0.007), RV GLS (- 7.9% vs. - 16.2%; p < 0.006), and LV strain rate (1.4 s-1 vs. 1.6 s-1; p < 0.003) were significantly higher (i.e., less negative). LV radial strain was without a statistically significant difference (20.7% vs. 22.6%; p = 0.1). Bivariate discriminant analysis for LV GLS and RV GLS revealed a sensitivity of 67% and specificity of 93% to differentiate between fetuses with CHD and healthy fetuses. CONCLUSION: Myocardial strain was successfully assessed in the human fetus, performing dynamic fetal cardiac MRI with DUS gating. Our study indicates that strain parameters may allow for differentiation between fetuses with and without CHD. CLINICAL RELEVANCE STATEMENT: Myocardial strain analysis by cardiac MRI with Doppler ultrasound gating and feature tracking may provide a new diagnostic approach for evaluation of fetal cardiac function in congenital heart disease. KEY POINTS: • MRI myocardial strain analysis has not been performed in human fetuses so far. • Myocardial strain was assessed in human fetuses using cardiac MRI with Doppler ultrasound gating. • MRI myocardial strain may provide a new diagnostic approach to evaluate fetal cardiac function.


Asunto(s)
Corazón Fetal , Cardiopatías Congénitas , Humanos , Femenino , Embarazo , Cardiopatías Congénitas/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética/métodos , Técnicas de Imagen Sincronizada Cardíacas/métodos
8.
Artículo en Inglés | MEDLINE | ID: mdl-39107951

RESUMEN

Relative uteroplacental insufficiency of labor (RUPI-L) is a clinical condition that refers to alterations in the fetal oxygen "demand-supply" equation caused by the onset of regular uterine activity. The term RUPI-L indicates a condition of "relative" uteroplacental insufficiency which is relative to a specific stressful circumstance, such as the onset of regular uterine activity. RUPI-L may be more prevalent in fetuses in which the ratio between the fetal oxygen supply and demand is already slightly reduced, such as in cases of subclinical placental insufficiency, post-term pregnancies, gestational diabetes, and other similar conditions. Prior to the onset of regular uterine activity, fetuses with a RUPI-L may present with normal features on the cardiotocography. However, with the onset of uterine contractions, these fetuses start to manifest abnormal fetal heart rate patterns which reflect the attempt to maintain adequate perfusion to essential central organs during episodes of transient reduction in oxygenation. If labor is allowed to continue without an appropriate intervention, progressively more frequent, and stronger uterine contractions may result in a rapid deterioration of the fetal oxygenation leading to hypoxia and acidosis. In this Commentary, we introduce the term relative uteroplacental insufficiency of labor and highlight the pathophysiology, as well as the common features observed in the fetal heart rate tracing and clinical implications.

9.
Acta Obstet Gynecol Scand ; 103(3): 479-487, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38059396

RESUMEN

INTRODUCTION: Since the 1970s, fetal scalp blood sampling (FSBS) has been used as a second-line test of the acid-base status of the fetus to evaluate fetal well-being during labor. The commonly employed thresholds that delineate normal pH (>7.25), subnormal (7.20-7.25), and pathological pH (<7.20) guide clinical decisions. However, these experienced-based thresholds, based on observations and common sense, have yet to be confirmed. The aim of the study was to investigate if pH drop rate accelerates at the common thresholds (7.25 and 7.20) and to explore the possibility of identifying more accurate thresholds. MATERIAL AND METHODS: A retrospective study was conducted at a tertiary maternity hospital between June 2017 and July 2021. Patients with at least one FSBS during labor for category II fetal heart rate and delivery of a singleton cephalic infant were included. The rate of change in pH value between consecutive samples for each patient was calculated and plotted as a function of pH value. Linear regression models were used to model the evolution of the pH drop rate estimating slope and standard errors across predefined pH intervals. Exploration of alternative pH action thresholds was conducted. To explore the independence of the association between pH value and pH drop rate, multiple linear regression adjusted on age, body mass index, parity, oxytocin stimulation and suspected small for gestational age was performed. RESULTS: We included 2047 patients with at least one FSBS (total FSBS 3467); with 2047 umbilical cord blood pH, and a total of 5514 pH samples. Median pH values were 7.29 1 h before delivery, 7.26 30 min before delivery. The pH drop was slow between 7.40 and 7.30, then became more pronounced, with median rates of 0.0005 units/min at 7.25 and 0.0013 units/min at 7.20. Out of the alternative pH thresholds, 7.26 and 7.20 demonstrated the best alignment with our dataset. Multiple linear regression revealed that only pH value was significantly associated to the rate of pH change. CONCLUSIONS: Our study confirms the validity and reliability of current guideline thresholds for fetal scalp pH in category II fetal heart rate.


Asunto(s)
Trabajo de Parto , Cuero Cabelludo , Embarazo , Humanos , Femenino , Estudios Retrospectivos , Reproducibilidad de los Resultados , Trabajo de Parto/fisiología , Feto , Sangre Fetal , Frecuencia Cardíaca Fetal/fisiología , Concentración de Iones de Hidrógeno , Monitoreo Fetal
10.
Acta Obstet Gynecol Scand ; 103(5): 980-991, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38229258

RESUMEN

INTRODUCTION: In clinical practice, fetal heart rate monitoring is performed intermittently using Doppler ultrasound, typically for 30 minutes. In case of a non-reassuring heart rate pattern, monitoring is usually prolonged. Noninvasive fetal electrocardiography may be more suitable for prolonged monitoring due to improved patient comfort and signal quality. This study evaluates the performance and patient experience of four noninvasive electrocardiography devices to assess candidate devices for prolonged noninvasive fetal heart rate monitoring. MATERIAL AND METHODS: Non-critically sick women with a singleton pregnancy from 24 weeks of gestation were eligible for inclusion. Fetal heart rate monitoring was performed during standard care with a Doppler ultrasound device (Philips Avalon-FM30) alone or with this Doppler ultrasound device simultaneously with one of four noninvasive electrocardiography devices (Nemo Fetal Monitoring System, Philips Avalon-Beltless, Demcon Dipha-16 and Dräger Infinity-M300). Performance was evaluated by: success rate, positive percent agreement, bias, 95% limits of agreement, regression line, root mean square error and visual agreement using FIGO guidelines. Patient experience was captured using a self-made questionnaire. RESULTS: A total of 10 women were included per device. For fetal heart rate, Nemo performed best (success rate: 99.4%, positive percent agreement: 94.2%, root mean square error 5.1 BPM, bias: 0.5 BPM, 95% limits of agreement: -9.7 - 10.7 BPM, regression line: y = -0.1x + 11.1) and the cardiotocography tracings obtained simultaneously by Nemo and Avalon-FM30 received the same FIGO classification. Comparable results were found with the Avalon-Beltless from 36 weeks of gestation, whereas the Dipha-16 and Infinity-M300 performed significantly worse. The Avalon-Beltless, Nemo and Infinity-M300 closely matched the performance of the Avalon-FM30 for maternal heart rate, whereas the performance of the Dipha-16 deviated more. Patient experience scores were higher for the noninvasive electrocardiography devices. CONCLUSIONS: Both Nemo and Avalon-Beltless are suitable devices for (prolonged) noninvasive fetal heart rate monitoring, taking their intended use into account. But outside its intended use limit of 36 weeks' gestation, the Avalon-Beltless performs less well, comparable to the Dipha-16 and Infinity-M300, making them currently unsuitable for (prolonged) noninvasive fetal heart rate monitoring. Noninvasive electrocardiography devices appear to be preferred due to greater comfort and mobility.


Asunto(s)
Cardiotocografía , Determinación de la Frecuencia Cardíaca , Embarazo , Femenino , Humanos , Cardiotocografía/métodos , Monitoreo Fetal/métodos , Electrocardiografía , Frecuencia Cardíaca Fetal/fisiología , Evaluación del Resultado de la Atención al Paciente
11.
BMC Pregnancy Childbirth ; 24(1): 136, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38355457

RESUMEN

BACKGROUND: While the effectiveness of cardiotocography in reducing neonatal morbidity is still debated, it remains the primary method for assessing fetal well-being during labor. Evaluating how accurately professionals interpret cardiotocography signals is essential for its effective use. The objective was to evaluate the accuracy of fetal hypoxia prediction by practitioners through the interpretation of cardiotocography signals and clinical variables during labor. MATERIAL AND METHODS: We conducted a cross-sectional online survey, involving 120 obstetric healthcare providers from several countries. One hundred cases, including fifty cases of fetal hypoxia, were randomly assigned to participants who were invited to predict the fetal outcome (binary criterion of pH with a threshold of 7.15) based on the cardiotocography signals and clinical variables. After describing the participants, we calculated (with a 95% confidence interval) the success rate, sensitivity and specificity to predict the fetal outcome for the whole population and according to pH ranges, professional groups and number of years of experience. Interobserver agreement and reliability were evaluated using the proportion of agreement and Cohen's kappa respectively. RESULTS: The overall ability to predict a pH level below 7.15 yielded a success rate of 0.58 (95% CI 0.56-0.60), a sensitivity of 0.58 (95% CI 0.56-0.60) and a specificity of 0.63 (95% CI 0.61-0.65). No significant difference in the success rates was observed with respect to profession and number of years of experience. The success rate was higher for the cases with a pH level below 7.05 (0.69) and above 7.20 (0.66) compared to those falling between 7.05 and 7.20 (0.48). The proportion of agreement between participants was good (0.82), with an overall kappa coefficient indicating substantial reliability (0.63). CONCLUSIONS: The use of an online tool enabled us to collect a large amount of data to analyze how practitioners interpret cardiotocography data during labor. Despite a good level of agreement and reliability among practitioners, the overall accuracy is poor, particularly for cases with a neonatal pH between 7.05 and 7.20. Factors such as profession and experience level do not present notable impact on the accuracy of the annotations. The implementation and use of a computerized cardiotocography analysis software has the potential to enhance the accuracy to detect fetal hypoxia, especially for ambiguous cardiotocography tracings.


Asunto(s)
Cardiotocografía , Hipoxia Fetal , Embarazo , Recién Nacido , Femenino , Humanos , Cardiotocografía/métodos , Hipoxia Fetal/diagnóstico , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Transversales , Frecuencia Cardíaca Fetal
12.
J Ultrasound Med ; 43(7): 1199-1209, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38465462

RESUMEN

OBJECTIVES: Due to the government's liberalization of epidemic control, the current 2019 novel coronavirus disease (COVID-19) has started to spread widely within China. This study aimed to use the fetal heart quantification (fetal HQ) technique to assess the cardiac function and morphology of the fetuses of pregnant women diagnosed with COVID-19 in the early stages of pregnancy. METHODS: Exactly 86 pregnant women diagnosed with COVID-19 infection in early pregnancy (COVID-19 group) and 90 healthy pregnant women (control group) who underwent fetal echocardiography were prospectively included in this study. The fetal HQ technique was applied to compare the differences in the global sphericity index (GSI), global strain values (GS), fractional area change (FAC), and 24-segment fractional shortening (FS) of the left and right ventricles, between the COVID-19 group and the control group. RESULTS: Compared with the control group, the differences in GS and 24-segment FS of the left ventricle in the COVID-19 group were not statistically significant. However, the COVID-19 group showed lower GSI values compared with the control group (1.24 vs 1.28). FAC (48.12%) of the left ventricle and GS (-23.55%), FAC (41.74%) of the right ventricle in the COVID-19 group were reduced compared with FAC (50.50%) of the left ventricle and GS (-27.63%), FAC (46.01%) of the right ventricle in the control group. Segmental analysis revealed reduced FS in segments 20-24 in the COVID-19 group compared with the control group. Right ventricular GS was an independent predictor of adverse pregnancy outcome with an optimal cutoff value of -18.66%. CONCLUSIONS: The results suggest that COVID-19 infection in early pregnancy may have a negative impact on fetal cardiac morphology and function. Fetal HQ may offer a new assessment method for the early identification of fetal cardiac alterations in pregnant women infected with COVID-19.


Asunto(s)
COVID-19 , Ecocardiografía , Corazón Fetal , Complicaciones Infecciosas del Embarazo , Ultrasonografía Prenatal , Humanos , Femenino , Embarazo , COVID-19/diagnóstico por imagen , COVID-19/fisiopatología , COVID-19/complicaciones , Corazón Fetal/diagnóstico por imagen , Corazón Fetal/fisiopatología , Adulto , Complicaciones Infecciosas del Embarazo/diagnóstico por imagen , Complicaciones Infecciosas del Embarazo/fisiopatología , Ultrasonografía Prenatal/métodos , Estudios Prospectivos , Ecocardiografía/métodos , SARS-CoV-2 , Sístole , China/epidemiología
13.
Adv Exp Med Biol ; 1441: 201-226, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38884713

RESUMEN

A well-developed heart is essential for embryonic survival. There are constant interactions between cardiac tissue motion and blood flow, which determine the heart shape itself. Hemodynamic forces are a powerful stimulus for cardiac growth and differentiation. Therefore, it is particularly interesting to investigate how the blood flows through the heart and how hemodynamics is linked to a particular species and its development, including human. The appropriate patterns and magnitude of hemodynamic stresses are necessary for the proper formation of cardiac structures, and hemodynamic perturbations have been found to cause malformations via identifiable mechanobiological molecular pathways. There are significant differences in cardiac hemodynamics among vertebrate species, which go hand in hand with the presence of specific anatomical structures. However, strong similarities during development suggest a common pattern for cardiac hemodynamics in human adults. In the human fetal heart, hemodynamic abnormalities during gestation are known to progress to congenital heart malformations by birth. In this chapter, we discuss the current state of the knowledge of the prenatal cardiac hemodynamics, as discovered through small and large animal models, as well as from clinical investigations, with parallels gathered from the poikilotherm vertebrates that emulate some hemodynamically significant human congenital heart diseases.


Asunto(s)
Corazón , Hemodinámica , Humanos , Animales , Hemodinámica/fisiología , Corazón/crecimiento & desarrollo , Corazón/fisiología , Cardiopatías Congénitas/fisiopatología
14.
J Perinat Med ; 52(3): 304-309, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38281095

RESUMEN

OBJECTIVES: Right aortic arch (RAA) is a rare anomaly with an incidence of 0.1 % in the adult population and low-risk fetuses. Our aim in this study was to evaluate associated anomalies and conditions according to subtypes. METHODS: This was a retrospective study examining consecutive pregnancies diagnosed with RAA in our hospital between 2018 and 2022. Fetuses with RAA were divided into three groups, RAA with right-sided ductus arteriosus (RAA-RDA), RAA with left-sided ductus arteriosus (RAA-LDA), and RAA with a double aortic arch (RAA-DAA). RESULTS: A total of 81 fetuses were diagnosed as having RAA during the study period. The rate of cardiac anomalies (82.8 %) in the RAA-RDA group was higher than in the RAA-LDA (17.6 %) and RAA-DAA (22.2 %) groups (p<0.001). No statistically significant difference was found between the groups in terms of maternal age, diagnosis week, pregnancy outcome, extracardiac anomalies, and genetic anomalies. Three (8 %) of 36 fetuses with isolated RAA who resulted in live birth developed symptoms related to the vascular ring, and one (2.7 %) newborn with RAA-DAA underwent surgery. CONCLUSIONS: The incidence of cardiac anomalies is high in fetuses with RAA-RDA. Ultrasound examinations should be performed for cardiac anomalies and additional structural anomalies. Vascular ring formation is a rare but important complication due to compression risk to the trachea and esophagus.


Asunto(s)
Síndromes del Arco Aórtico , Cardiopatías Congénitas , Anillo Vascular , Adulto , Recién Nacido , Femenino , Embarazo , Humanos , Anillo Vascular/complicaciones , Anillo Vascular/diagnóstico por imagen , Anillo Vascular/epidemiología , Aorta Torácica/diagnóstico por imagen , Estudios Retrospectivos , Antivirales , Ultrasonografía Prenatal/métodos , Diagnóstico Prenatal , Resultado del Embarazo/epidemiología , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/epidemiología , Síndromes del Arco Aórtico/diagnóstico por imagen , Síndromes del Arco Aórtico/epidemiología , Feto
15.
J Perinat Med ; 52(4): 399-405, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38404246

RESUMEN

OBJECTIVES: This study aims to show the relation between biomarkers in maternal and cord-blood samples and fetal heart rate variability (fHRV) metrics through a non-invasive fetal magnetocardiography (fMCG) technique. METHODS: Twenty-three women were enrolled for collection of maternal serum and fMCG tracings immediately prior to their scheduled cesarean delivery. The umbilical cord blood was collected for measurement of biomarker levels. The fMCG metrics were then correlated to the biomarker levels from the maternal serum and cord blood. RESULTS: Brain-derived neurotrophic factor (BDNF) had a moderate correlation with fetal parasympathetic activity (0.416) and fetal sympathovagal ratios (-0.309; -0.356). Interleukin (IL)-6 also had moderate-sized correlations but with an inverse relationship as compared to BDNF. These correlations were primarily in cord-blood samples and not in the maternal blood. CONCLUSIONS: In this small sample-sized exploratory study, we observed a moderate correlation between fHRV and cord-blood BDNF and IL-6 immediately preceding scheduled cesarean delivery at term. These findings need to be validated in a larger population.


Asunto(s)
Biomarcadores , Factor Neurotrófico Derivado del Encéfalo , Sangre Fetal , Frecuencia Cardíaca Fetal , Interleucina-6 , Humanos , Femenino , Embarazo , Factor Neurotrófico Derivado del Encéfalo/sangre , Frecuencia Cardíaca Fetal/fisiología , Adulto , Biomarcadores/sangre , Sangre Fetal/metabolismo , Sangre Fetal/química , Interleucina-6/sangre , Magnetocardiografía/métodos , Cesárea
16.
BMC Med Inform Decis Mak ; 24(1): 19, 2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38247009

RESUMEN

BACKGROUND: In clinical medicine, fetal heart rate (FHR) monitoring using cardiotocography (CTG) is one of the most commonly used methods for assessing fetal acidosis. However, as the visual interpretation of CTG depends on the subjective judgment of the clinician, this has led to high inter-observer and intra-observer variability, making it necessary to introduce automated diagnostic techniques. METHODS: In this study, we propose a computer-aided diagnostic algorithm (Hybrid-FHR) for fetal acidosis to assist physicians in making objective decisions and taking timely interventions. Hybrid-FHR uses multi-modal features, including one-dimensional FHR signals and three types of expert features designed based on prior knowledge (morphological time domain, frequency domain, and nonlinear). To extract the spatiotemporal feature representation of one-dimensional FHR signals, we designed a multi-scale squeeze and excitation temporal convolutional network (SE-TCN) backbone model based on dilated causal convolution, which can effectively capture the long-term dependence of FHR signals by expanding the receptive field of each layer's convolution kernel while maintaining a relatively small parameter size. In addition, we proposed a cross-modal feature fusion (CMFF) method that uses multi-head attention mechanisms to explore the relationships between different modalities, obtaining more informative feature representations and improving diagnostic accuracy. RESULTS: Our ablation experiments show that the Hybrid-FHR outperforms traditional previous methods, with average accuracy, specificity, sensitivity, precision, and F1 score of 96.8, 97.5, 96, 97.5, and 96.7%, respectively. CONCLUSIONS: Our algorithm enables automated CTG analysis, assisting healthcare professionals in the early identification of fetal acidosis and the prompt implementation of interventions.


Asunto(s)
Acidosis , Enfermedades Fetales , Femenino , Embarazo , Humanos , Acidosis/diagnóstico , Algoritmos , Cardiotocografía , Toma de Decisiones , Inteligencia Artificial
17.
Pediatr Cardiol ; 45(3): 605-613, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38112807

RESUMEN

Although commonly performed, optimal techniques, strategies, and content to achieve the most effective prenatal counseling have not been explored. We investigate the efficacy of prenatal counseling via survey feedback of parents of children with prenatally diagnosed single ventricle. Grades of counseling using a Likert scale (1-5) were solicited to assess: (1) overall impression of quantity of counseling, (2) explanation of the heart defect, (3) preparation for heart surgery, (4) preparation for hospital course and care, (5) preparation for complications and outcomes of a Fontan circulation, and (6) preparation for neurological, school-related, or behavioral problems. Impressions were solicited concerning specific providers. A comprehensive fetal counseling score was calculated for each participant. Burden of care including length of hospitalization was explored as impacting prenatal counseling grades. There were 59 survey respondents. Average age of the children at the time of survey was 4.6 ± 3.3 years (range 1-10 years). Highest grades were for explanation of the heart condition, with lowest grades for preparation for neurological, school-related, or behavioral problems. Cardiac surgeon received the highest with social worker lowest grade for provider. Negative correlation was found between the composite fetal counseling score and parental recollection of length of hospitalization (Pearson r = - 0.357, p < 0.01). Prenatal counseling for neurological, school-related, and behavioral problems in single ventricle is deficient. Further studies analyzing prenatal counseling techniques and content can help improve upon the delivery of this important aspect of prenatal care.


Asunto(s)
Procedimiento de Fontan , Cardiopatías Congénitas , Corazón Univentricular , Embarazo , Niño , Femenino , Humanos , Lactante , Preescolar , Cardiopatías Congénitas/cirugía , Cardiopatías Congénitas/diagnóstico , Atención Prenatal , Padres/psicología , Consejo/métodos , Diagnóstico Prenatal , Ultrasonografía Prenatal
18.
Pediatr Cardiol ; 45(4): 740-748, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38393337

RESUMEN

Morphology and function in a fetal heart with severe tricuspid regurgitation remains challenging. The aim of this study was to assess cardiac morphology and function in fetuses with severe tricuspid regurgitation by fetal heart quantification (HQ) and to assess the practical value of fetal HQ. Clinical information was analyzed for 63 pregnant women who underwent fetal cardiac ultrasonography. The women were divided into those who had a fetus with severe tricuspid regurgitation (n = 20) and those with a normal fetus (n = 40). The global sphericity index (GSI), fractional area change (FAC), and global longitudinal strain (GLS) of both ventricles and the sphericity index (SI) and fractional shortening (FS) of 24 segments were quantified by fetal HQ using speckle tracking imaging. Fetuses with severe tricuspid regurgitation had a significantly lower GSI (1.14 ± 0.10 vs. 1.26 ± 0.08, p < 0.001) and a higher GSI Z-score (-0.98 ± 1.01 vs. 0.25 ± 0.87, p < 0.001) as well as a significantly lower right ventricular FAC (36.50 ± 7.34% vs. 45.19 ± 3.39%, p < 0.001), FAC Z-score (-1.02 ± 1.41 vs. 0.49 ± 0.74, p < 0.001), and GLS (-21.01 ± 5.66% vs. 45.19 ± 3.49%, p < 0.001). The SI and SI Z-score were significantly lower in segments 1-18 of the right ventricle in fetuses with severe tricuspid regurgitation (p < 0.05); furthermore, FS of segments 1-12 and 19-24 and the FS Z-score of segments 18-24 were significantly lower in fetuses with severe tricuspid regurgitation (p < 0.05). Fetal HQ is useful for evaluation of cardiac morphology and function in fetuses with severe tricuspid regurgitation and can provide important reference information for both clinical diagnosis and treatment.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Embarazo , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Corazón Fetal/diagnóstico por imagen , Ventrículos Cardíacos , Ultrasonografía Prenatal/métodos
19.
Arch Gynecol Obstet ; 309(3): 993-1000, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-36854985

RESUMEN

PURPOSE: To clarify whether maternal oxygen administration during vaginal delivery improves umbilical artery (UA) gas measurements and neonatal outcomes. METHODS: Singleton pregnancies requiring operative vaginal delivery or emergency cesarean section (CS) due to non-reassuring fetal status (NRFS) during vaginal delivery at our hospital from 2018 to 2021 were retrospectively investigated. Intrapartum fetal wellbeing was evaluated based on the 5-tier fetal heart rate (FHR) pattern which is a delivery management method widely used in Japan. Operative vaginal deliveries or emergency CS was performed under integrated judgment in NRFS. Patients were divided into the oxygen group to whom oxygen (10 L/min) was supplied by a facemask and the room air group. The UA gas measurements and neonatal outcomes were compared. The oxygen administration was classified by conditions before and after the coronavirus disease 2019 pandemic. As a secondary evaluation, stratification of FHR pattern levels and factors associated with UA pH < 7.15 were examined. RESULTS: A total of 250 patients required obstetric surgical delivery due to NRFS, including 140 (56%) and 110 (44%) in the oxygen and room air groups, respectively. No differences in maternal background factors were found between both groups, except for maternal age. UA gas measurements and neonatal outcomes also showed no significant differences. No significant factors were extracted in the multivariate analysis for UA pH < 7.15. CONCLUSIONS: Trans-maternal oxygen administration for intrapartum NRFS did not affect neonatal cord blood gasses or neonatal outcomes. Thus, routine oxygen administration for intrapartum NRFS may not always be necessary.


Asunto(s)
Cesárea , Arterias Umbilicales , Recién Nacido , Embarazo , Humanos , Femenino , Estudios Retrospectivos , Parto Obstétrico , Oxígeno
20.
Arch Gynecol Obstet ; 309(4): 1341-1351, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36966429

RESUMEN

PURPOSE: In adults and fetuses, N-terminal pro-B-type natriuretic peptide (NT-proBNP) is a marker of cardiac failure and myocardial remodelling. We examined the effect of anemia and intrauterine transfusion (IUT) on NT-proBNP concentrations in fetuses with anemia and established gestational age-dependent reference values of a control group. METHODS: We analyzed NT-proBNP levels in anemic fetuses that underwent serial intrauterine transfusions (IUT), focusing on different causes and severity of anemia and comparing the results to a non-anemic control group. RESULTS: In the control group, the average NT-proBNP concentration was 1339 ± 639 pg/ml, decreasing significantly with increasing gestational age (R = - 74.04, T = - 3.65, p = 0.001). Subjects had significantly higher NT-proBNP concentrations before initiation of IUT therapy (p < 0.001), showing fetuses with parvovirus B19 (PVB19) infection having the highest concentrations. Hydropic fetuses also showed an increased NT-proBNP concentration compared to non-hydropic fetuses (p < 0.001). During the course of therapy, NT-proBNP concentration before subsequent IUT decreased significantly from pathologically high levels, while MoM-Hb and MoM-MCA-PSV remained pathological. CONCLUSION: NT-pro BNP levels in non-anemic fetuses are higher than in postnatal life, decreasing with ongoing pregnancy. Anemia is a hyperdynamic state and its severity correlates with circulating NT-proBNP levels. Highest concentrations occur in fetuses with hydrops and with PVB19 infection, respectively. Treatment by IUT leads to a normalisation of NT-proBNP concentrations, so the measurement of its levels may be useful in therapy monitoring.


Asunto(s)
Anemia , Enfermedades Fetales , Fragmentos de Péptidos , Embarazo , Femenino , Adulto , Humanos , Enfermedades Fetales/terapia , Péptido Natriurético Encefálico , Anemia/terapia , Feto , Transfusión de Sangre Intrauterina/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA