Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.956
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Anal Biochem ; 686: 115428, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38103628

RESUMEN

Ultrasensitive detection of circulating tumor cells (CTCs) holds significant clinical importance in monitoring metastasis and therapeutic outcomes. In this study, we have developed a novel electrochemical sensing model based on nanomaterials for highly sensitive and specific determination of CTCs. A gold electrode co-modified with Ketjin black (KB) and Au nanoparticles (AuNPs) exhibits exceptional conductivity. By conjugating palladium-iridium cubic nanozyme (Pd-Ir CNE) with antibodies, we have created a detection probe capable of catalyzing hydrogen peroxide (H2O2), thereby amplifying the output signal and resulting in significantly enhanced current on the electrode for detecting CTCs. The constructed immunosensor has achieved a detection limit of 2 cell mL-1 for model MCF-7 cells. Furthermore, the as-constructed electrochemical immunosensor can accurately detect whole blood-spiked target CTCs, showing great promise for clinical applications in early cancer diagnosis and prognosis.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Células Neoplásicas Circulantes , Humanos , Oro , Límite de Detección , Técnicas Biosensibles/métodos , Peróxido de Hidrógeno , Anticuerpos Inmovilizados , Inmunoensayo/métodos , Técnicas Electroquímicas/métodos
2.
Anal Biochem ; 692: 115571, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38796119

RESUMEN

Markers of myocardial injury, such as myoglobin (Mb), are substances swiftly released into the peripheral bloodstream upon myocardial cell injury or altered cardiac activity. During the onset of acute myocardial infarction, patients experience a significant surge in serum Mb levels. Given this, precise detection of Mb is essential, necessitating the development of innovative assays to optimize detection capabilities. This study introduces the synthesis of a three-dimensional hierarchical nanocomposite, Cubic-ZIF67@Au-rGOF-NH2, utilizing aminated reduced graphene oxide and zeolite imidazolium ester framework-67 (ZIF67) as foundational structures. Notably, this novel material, applied in a label-free electrochemical immunosensor, presents a groundbreaking approach for detecting myocardial injury markers. Experimental outcomes revealed ZIF67 and AuNPs exhibit enhanced affinity and growth on the 3D-rGOF-NH2 matrix, thus amplifying electrical conductivity while preserving the inherent electrochemical attributes of ZIF67. As a result, the Cubic-ZIF67@Au-rGOF-NH2 label-free electrochemical immunosensor exhibited a broad detection range and high sensitivity for Mb. The derived standard curve was ΔIp = 16.67552lgC+275.245 (R = 0.993) with a detection threshold of 3.47 fg/ml. Moreover, recoveries of standards spiked into samples ranged between 96.3% and 108.7%. Importantly, the devised immunosensor retained notable selectivity against non-target proteins, proving its potential clinical utility based on exemplary sample analysis performance.


Asunto(s)
Técnicas Electroquímicas , Oro , Grafito , Estructuras Metalorgánicas , Mioglobina , Mioglobina/análisis , Técnicas Electroquímicas/métodos , Grafito/química , Estructuras Metalorgánicas/química , Oro/química , Humanos , Técnicas Biosensibles/métodos , Nanocompuestos/química , Zeolitas/química , Imidazoles/química , Límite de Detección , Nanopartículas del Metal/química
3.
Biomed Microdevices ; 26(1): 8, 2024 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-38180587

RESUMEN

Cancer antigen 125 (CA125) is the most common biomarker used to diagnose and monitor ovarian cancer progression for the last four decades, and precise detection of its levels in blood serum is crucial. In this work, label-free impedimetric CA125 immunosensors were fabricated by using screen-printed carbon electrodes modified with poly toluidine blue (PTB) (in deep eutectic solvent)/gold nanoparticles (AuNP) for the sensitive, environmentally friendly, economical, and practical analysis of CA125. The materials of PTBDES and AuNP were characterized by Fourier Transform Infrared (FT-IR), Scanning Electron Microscope (FE-SEM), and X-ray Diffraction (XRD). The analysis of the CA125 was performed by electrochemical impedance spectroscopy and the developed immunosensor. The immunosensor's repeatability, reproducibility, reusability, selectivity, and storage stability were examined. The developed label-free immunosensor allowed the determination of CA125 in fast, good repeatability and a low limit of detection (1.20 pg mL-1) in the linear range of 5-100 pg mL-1. The stable surface of the fabricated immunosensor was successfully regenerated ten times. The application of immunosensors in commercial human blood serum was performed, and good recoveries were achieved. The disposable label-free impedimetric CA125 immunosensor developed for the rapid and practical detection of CA125 is a candidate for use in point-of-care tests in clinical applications of ovarian cancer.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Neoplasias Ováricas , Humanos , Femenino , Antígeno Ca-125 , Oro , Inmunoensayo , Reproducibilidad de los Resultados , Espectroscopía Infrarroja por Transformada de Fourier , Neoplasias Ováricas/diagnóstico
4.
J Nanobiotechnology ; 22(1): 239, 2024 May 12.
Artículo en Inglés | MEDLINE | ID: mdl-38735951

RESUMEN

Widespread distribution of porcine epidemic diarrhea virus (PEDV) has led to catastrophic losses to the global pig farming industry. As a result, there is an urgent need for rapid, sensitive and accurate tests for PEDV to enable timely and effective interventions. In the present study, we develop and validate a floating gate carbon nanotubes field-effect transistor (FG CNT-FET)-based portable immunosensor for rapid identification of PEDV in a sensitive and accurate manner. To improve the affinity, a unique PEDV spike protein-specific monoclonal antibody is prepared by purification, and subsequently modified on FG CNT-FET sensor to recognize PEDV. The developed FET biosensor enables highly sensitive detection (LoD: 8.1 fg/mL and 100.14 TCID50/mL for recombinant spike proteins and PEDV, respectively), as well as satisfactory specificity. Notably, an integrated portable platform consisting of a pluggable FG CNT-FET chip and a portable device can discriminate PEDV positive from negative samples and even identify PEDV and porcine deltacoronavirus within 1 min with 100% accuracy. The portable sensing platform offers the capability to quickly, sensitively and accurately identify PEDV, which further points to a possibility of point of care (POC) applications of large-scale surveillance in pig breeding facilities.


Asunto(s)
Técnicas Biosensibles , Nanotubos de Carbono , Virus de la Diarrea Epidémica Porcina , Virus de la Diarrea Epidémica Porcina/aislamiento & purificación , Animales , Porcinos , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Nanotubos de Carbono/química , Límite de Detección , Inmunoensayo/métodos , Inmunoensayo/instrumentación , Anticuerpos Monoclonales/inmunología , Transistores Electrónicos , Enfermedades de los Porcinos/diagnóstico , Enfermedades de los Porcinos/virología , Glicoproteína de la Espiga del Coronavirus/inmunología , Glicoproteína de la Espiga del Coronavirus/análisis , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/veterinaria , Infecciones por Coronavirus/virología , Anticuerpos Antivirales/inmunología , Diseño de Equipo
5.
J Invertebr Pathol ; 204: 108080, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38432354

RESUMEN

Bombyx mori nucleopolyhedrovirus (BmNPV) is highly contagious and poses a serious threat to sericulture production. Because there are currently no effective treatments for BmNPV, a rapid and simple detection method is urgently needed. This paper describes an electrochemical immunosensor for the detection of BmNPV. The immunosensor was fabricated by covalently immobilizing anti-BmNPV, a biorecognition element, onto the surface of the working gold electrode via 11-mercaptoundecanoic acid (MUA)/ß-mercaptoethanol (ME) hybrid self-assembled monolayers. Electrochemical impedance spectroscopy (EIS) and atomic force microscopy (AFM) were used to characterize the electrochemical performance and morphology of the immunosensor, respectively. Under optimum conditions, the developed immunosensor exhibited a linear response to BmNPV polyhedrin in the range of 1 × 102-1 × 108 fg/mL, with a low detection limit of 14.54 fg/mL. The immunosensor also exhibited remarkable repeatability, reproducibility, specificity, accuracy, and regeneration. Normal silkworm blood was mixed with BmNPV polyhedrin and analyzed quantitatively using this sensor, and the recovery was 92.31 %-100.61 %. Additionally, the sensor was used to analyze silkworm blood samples at different time points after BmNPV infection, and an obvious antigen signal was detected at 12 h post infection. Although this result agreed with that provided by the conventional polymerase chain reaction (PCR) method, the electroanalysis method established in this study was simpler, shorter in detection period, and lower in material cost. Furthermore, this innovative electrochemical immunosensor, developed for the ultra-sensitive and rapid detection of BmNPV, can be used for the early detection of virus-infected silkworms.


Asunto(s)
Técnicas Biosensibles , Bombyx , Nucleopoliedrovirus , Nucleopoliedrovirus/aislamiento & purificación , Técnicas Biosensibles/métodos , Animales , Bombyx/virología , Técnicas Electroquímicas/métodos , Inmunoensayo/métodos
6.
J Immunoassay Immunochem ; 45(4): 307-324, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38776466

RESUMEN

Single Chain Variable Fragment (scFv), a small fragment of antibody can be used to substitute the monoclonal antibody for diagnostic purposes. Production of scFv in Escherichia coli host has been a challenge due to the potential miss-folding and formation of inclusion bodies. This study aimed to express anti-CHIKV E2 scFv which previously designed specifically for Asian strains by co-expression of three chaperones that play a role in increasing protein solubility; GroEL, GroES, and Trigger Factor. The scFv and chaperones were expressed in Origami B E. coli host under the control of the T7 promoter, and purified using a Ni-NTA column. Functional assay of anti-CHIKV-E2 scFv was examined by electrochemical immunosensor using gold modified Screen Printed Carbon Electrode (SPCE), and characterized by differential pulses voltammetry (DPV) using K3[Fe(CN)6] redox system and scanning microscope electron (SEM). The experimental condition was optimized using the Box-Behnken design. The results showed that co-expression of chaperone increased the soluble scFv yield from 54.405 µg/mL to 220.097 µg/mL (~5×). Furthermore, scFv can be used to detect CHIKV-E2 in immunosensor electrochemistry with a detection limit of 0.74048 ng/mL and a quantification limit of 2,24388 ng/mL. Thus, the scFv-anti-CHIKV-E2 can be applied as a bioreceptor in another immunoassay method.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Escherichia coli , Chaperonas Moleculares , Anticuerpos de Cadena Única , Anticuerpos de Cadena Única/inmunología , Anticuerpos de Cadena Única/química , Anticuerpos de Cadena Única/genética , Escherichia coli/metabolismo , Escherichia coli/genética , Chaperonas Moleculares/inmunología , Inmunoensayo/métodos
7.
Mikrochim Acta ; 191(1): 76, 2024 01 04.
Artículo en Inglés | MEDLINE | ID: mdl-38172448

RESUMEN

A new conductive ink based on the addition of carbon black to a poly(vinyl alcohol) matrix is developed and investigated for electrochemical sensing and biosensing applications. The produced devices were characterized using morphological and electrochemical techniques and modified with Pd nanoparticles to enhance electrical conductivity and reaction kinetics. With the aid of chemometrics, the parameters for metal deposition were investigated and the sensor was applied to the determination of Parkinson's disease biomarkers, specifically epinephrine and α-synuclein. A linear behavior was obtained in the range 0.75 to 100 µmol L-1 of the neurotransmitter, and the device displayed a limit of detection (LOD) of 0.051 µmol L-1. The three-electrode system was then tested using samples of synthetic cerebrospinal fluid. Afterward, the device was modified with specific antibodies to quantify α-synuclein using electrochemical impedance spectroscopy. In phosphate buffer, a linear range was obtained for α-synuclein concentrations from 1.5 to 15 µg mL-1, with a calculated LOD of 0.13 µg mL-1. The proposed immunosensor was also applied to blood serum samples, and, in this case, the linear range was observed from 6.0 to 100.5 µg mL-1 of α-synuclein, with a LOD = 1.3 µg mL-1. Both linear curves attend the range for the real diagnosis, demonstrating its potential application to complex matrices.


Asunto(s)
Técnicas Biosensibles , Nanopartículas , Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/diagnóstico , alfa-Sinucleína , Técnicas Biosensibles/métodos , Inmunoensayo
8.
Mikrochim Acta ; 191(7): 381, 2024 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858277

RESUMEN

Nanosized sodium bismuth perovskite titanate (NBT) was synthesized and first used as the electrochemical immune sensing platform for the sensitive detection of carcinoembryonic antigen (CEA). Gold nanoparticles (Au NPs) grew on the surface of NBT through forming Au-N bond to obtain Au@NBT, and a label-free electrochemical immunosensor was proposed using Au@NBT as an immunosensing recognizer towards CEA. The well-ordered crystal structure of NBT was not changed at all after the modification of Au NPs outside, but significantly improved the conductivity, catalytic activity, and biocompatibility of the Au@NBT-modified electrode. The unique cubic crystal nanostructure of NBT offered a large active area for both Au NP modification and the subsequent immobilization of biomolecules over the electrode surface, triggering the effective generation of promising properties of the proposed Au@NBT-based electrochemical immunosensor. As expected, favorable detection performances were achieved using this immunosensor towards CEA detection, where a good linear relationship between the current response and CEA concentration was obtained in the concentration range 10 fg mL-1 to 100 ng mL-1 with a low detection limit (LOD) of 13.17 fg mL-1. Also, the significantly enhanced selectivity, and stability guaranteed the promising electrochemical properties of this immunosensor. Furthermore, the analysis of real serum samples verified the high feasibility of this new method in clinical CEA detection. This work opens a new window for the application of nanoperovskite in the early detection of CEA.


Asunto(s)
Bismuto , Antígeno Carcinoembrionario , Técnicas Electroquímicas , Oro , Límite de Detección , Nanopartículas del Metal , Titanio , Antígeno Carcinoembrionario/sangre , Antígeno Carcinoembrionario/inmunología , Titanio/química , Técnicas Electroquímicas/métodos , Humanos , Inmunoensayo/métodos , Oro/química , Nanopartículas del Metal/química , Bismuto/química , Técnicas Biosensibles/métodos , Óxidos/química , Anticuerpos Inmovilizados/inmunología , Compuestos de Calcio/química , Electrodos
9.
Mikrochim Acta ; 191(7): 387, 2024 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-38869719

RESUMEN

A novel construction strategy is introduced for an ultrasensitive dynamic light scattering (DLS) immunosensor targeting alpha fetoprotein (AFP). This approach relies on a self-assembled heptamer fusion protein (A1-C4bpα), incorporating the dual functions of multivalent recognition and crosslinking aggregation amplification due to the presence of seven AFP-specific A1 nanobodies on the A1-C4bpα heptamer. Leveraging antibody-functionalized magnetic nanoparticles for target AFP capture and DLS signal output, the proposed heptamer-assisted DLS immunosensor offers high sensitivity, strong specificity, and ease of operation. Under the optimized conditions, the designed DLS immunosensor demonstrates excellent linear detection of AFP in the concentration range 0.06 ng mL-1 to 512 ng mL-1, with a detection limit of 15 pg mL-1. The selectivity, accuracy, precision, practicability, and reliability of this newly developed method were further validated through an assay of AFP levels in spiked and actual human serum samples. This work introduces a novel approach for constructing ultrasensitive DLS immunosensors, easily extendable to the sensitive determination of other targets via simply replacing the nanobody sequence, holding great promise in various applications, particularly in disease diagnosis.


Asunto(s)
Dispersión Dinámica de Luz , Límite de Detección , alfa-Fetoproteínas , alfa-Fetoproteínas/análisis , alfa-Fetoproteínas/inmunología , Humanos , Inmunoensayo/métodos , Anticuerpos Inmovilizados/inmunología , Técnicas Biosensibles/métodos , Anticuerpos de Dominio Único/química , Anticuerpos de Dominio Único/inmunología , Nanopartículas de Magnetita/química
10.
Mikrochim Acta ; 191(2): 111, 2024 01 22.
Artículo en Inglés | MEDLINE | ID: mdl-38252316

RESUMEN

A simple and ultrasensitive sandwich-type electrochemiluminescence (ECL) immunosensor has been developed using porous three-dimensional gold nanoparticles (Au NPs) iron(Fe)-zinc(Zn) metal-organic frameworks (Au NPs-FeZn-MOFs@luminol) as high-efficiency ECL signal probes with Fe single-atom catalysts (SACs) (Fe-N-C SACs) as potentially advanced coreaction accelerators and dissolved oxygen as a coreaction agent to realize an H2O2-free amplification method for detecting carcinoembryonic antigen (CEA). The cathodic ECL of luminol, which was usually negligible, increased first. Because the Fe-N-C SACs exhibited an outstanding catalytic performance and a unique electronic structure, different reactive oxygen species (ROS) were generated via the oxygen reduction reaction. ROS oxidized the luminol anions to luminol anion radicals, preventing the time-consuming luminol electrochemical oxidation. Furthermore, the luminol anion radicals generated in situ reacted with ROS to produce potent cathodic ECL emissions. The immunosensor exhibited favorable analytical accuracy (detection range: 0.1 pg mL-1 - 80 ng mL-1), and its detection limit for serum samples was 0.031 pg mL-1 (S/N = 3). Consequently, the proposed strategy offers a new approach for early screening of CEA.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Antígeno Carcinoembrionario , Oro , Inmunoensayo , Luminol , Especies Reactivas de Oxígeno , Hierro , Aniones
11.
Mikrochim Acta ; 191(3): 166, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38418675

RESUMEN

The evaluation of electrochemical sensing activity of hydrothermally derived PPy-MoS2-based nanocomposites subjected to 90 MeV C6+ ion beam with fluence ranging, 1.0 × 1010-1.0 × 1013 ions/cm2, is reported. Cross-linking, chain scissioning, and ion track formation could occur in the irradiated systems, as revealed from Fourier transform infrared (FTIR) spectroscopy and field emission scanning electron microscopy (FE-SEM) studies. Electrochemical studies, viz., cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were performed in 0.1 M phosphate buffer solution (PBS) containing 5 mM K3[Fe(CN)6] as redox probe. High redox activity, lower charge transfer resistance (Rct = 490 Ω) and larger electroactive area (A = 0.4485 cm2) were obtained in case of the composite system irradiated with a fluence of 3.5 × 1011 ions/cm2. Immunosensor fabrication was executed via immobilization of mouse IgG over the pristine and post-irradiated electrodes. Afterwards, differential pulse voltammetry (DPV) was performed within the potential window - 0.2 to + 0.6 V (vs. Ag/AgCl) for the detection of specific analyte. Noticeably, the electrode system irradiated with a fluence of 3.5 × 1011 ions/cm2 is characterized by a lower limit of detection (LOD) of 0.203 nM and a higher sensitivity value of 10.0 µA mL ng-1 cm-2. The energetic particle irradiation at a modest fluence can offer beneficial effects to the PPy-MoS2-based nanohybrid system providing immense scope as advanced electrochemical biosensor.

12.
Mikrochim Acta ; 191(4): 210, 2024 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-38499672

RESUMEN

A ratiometric assay was designed to improve the sensitivity and reliability of electrochemical immunosensors for deoxynivalenol (DON) detection. The indicator signal caused by the Fe-based metal-organic framework nanocomposites loaded with gold nanoparticles and the internal reference signal from the [Fe(CN)6]3-/4- in the electrolyte came together at the immunosensor. When immunoreactivity occurred, the indicator signals decreased as the concentration of DON increased, while the internal reference signals increased slightly. The ratio of the indicator signal to the internal reference signal was available for reproducible and sensitive monitoring of DON. The prepared immunosensor showed excellent performance in the range from 0.5 to 5000 pg mL-1, and the detection limit was 0.0166 pg mL-1. The immunosensor achieved satisfactory detection toward DON in spiked and actual samples and has a promising application in the control of DON in grain products.


Asunto(s)
Técnicas Biosensibles , Nanopartículas del Metal , Tricotecenos , Técnicas Electroquímicas , Inmunoensayo , Oro , Reproducibilidad de los Resultados
13.
Mikrochim Acta ; 191(5): 239, 2024 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-38570399

RESUMEN

To accurately detect tumor marker carbohydrate antigen 72-4 (CA72-4) of serum samples is of great significance for the early diagnosis of malignant tumors. In the present study, MnO2/hollow nanobox metal-organic framework (HNM)-AuPtPd nanocomposites were prepared via multi-step synthesis and superposition method and a series of characterizations were carried out. A highly sensitive immunosensor Ab/MnO2/HNM-AuPtPd/GCE based on the composite nanomaterial was further prepared and used to detect the tumor marker CA72-4. The constructed immunosensor achieved signal amplification by increasing the electrocatalytic activity to H2O2 by means of the synergistic effect of MnO2 ultra-thin nanosheets (MnO2 UNs) and HNM-AuPtPd. At the same time, the electrochemical properties of the immunosensor were analyzed using cyclic voltammetry, electrochemical impedance, amperometry (with the test voltage of -0.4 V), and differential pulse voltammetry. The experimental results showed that the MnO2/HNM-AuPtPd nanocomposites were successfully prepared, and the immunosensor Ab/MnO2/HNM-AuPtPd/GCE demonstrated an excellent electrochemical performance. The electrochemical immunosensor had the highest detection sensitivity under the optimal experimental conditions, such as incubation pH of 7.0, incubation time of 60 min, with the addition of 15 µL of H2O2, and in the concentration range 0.001-500 U/mL. It had a low detection limit of 1.78×10-5 U/mL (S/N = 3). Moreover, the serum sample recovery were in the range from 99.38 to 100.52%. This study provides a new method and experimental basis for the detection of tumor markers in clinical practice.


Asunto(s)
Antígenos de Carbohidratos Asociados a Tumores , Técnicas Biosensibles , Nanocompuestos , Biomarcadores de Tumor , Técnicas Biosensibles/métodos , Peróxido de Hidrógeno/química , Compuestos de Manganeso/química , Óxidos/química , Inmunoensayo , Nanocompuestos/química
14.
Mikrochim Acta ; 191(1): 69, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38165489

RESUMEN

The design of a novel electrochemical impedimetric biosensor for label-free analysis of resistin, a biomarker for obesity, is reported. For the fabrication of the immunosensor, a novel approach composed of electrochemical copolymerization of double epoxy groups-substituted thiophene (ThidEp) and 3,4-Ethylenedioxythiophene (EDOT) monomers was utilized. Anti-resistin antibodies were covalently attached to the copolymer-coated electrode. The capture of resistin antigens by anti-resistin antibodies caused significant variations in charge transfer resistance (Rct) because of the immunoreactions between these proteins. Under optimum experimental variables, the changes in impedance signals were employed for the determination of resistin antigen concentration, and the prepared immunosensor based on conjugated copolymer illustrated a wide linear range between 0.0125 and 22.5 pg/mL, a low detection limit (LOD) of 3.71 fg/mL, and a good sensitivity of 1.22 kΩ pg-1mL cm2. The excellent analytical performance of the resistin immunosensor in terms of selectivity, sensitivity, repeatability, reproducibility, storage stability, and low detection limit might be attributed to the conductive copolymer film layer generation on the disposable indium tin oxide (ITO) platform. The capability of this system for the determination of resistin in human serum and saliva samples was also tested. The immunosensor results were in accordance with the enzyme-linked immunosorbent assay (ELISA) results. The matrix effects of human serum and saliva were also investigated, and the proposed immunosensor displayed good recovery ranging from 95.91 to 106.25%. The engineered immunosensor could open new avenues for obesity monitoring.


Asunto(s)
Técnicas Biosensibles , Resistina , Humanos , Inmunoensayo , Reproducibilidad de los Resultados , Biomarcadores , Obesidad/diagnóstico , Poli A , Polímeros
15.
Mikrochim Acta ; 191(7): 419, 2024 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916771

RESUMEN

A method is presented for chemiluminescence resonance energy transfer (CRET) using APTES-Fe3O4 as a highly efficient energy acceptor with strong magnetic effectiveness over extended distances, while an Au@BSA-luminol composite acts as the donor. In order to boost the chemiluminescence reactions, CuO nanoparticles were successfully employed. The distance between the donor and acceptor is a crucial factor in the occurrence of the CRET phenomenon. A sensitive and high-throughput sandwich chemiluminescence immunosensor has been developed accordingly with a linear range of 1.0 × 10-7 g/L to 6.0 × 10-5 g/L and a limit of detection of 0.8 × 10-7 g/L. The CRET-based sandwich immunosensor has the potential to be implemented to early cancer diagnosis because of its high sensitivity in detecting Nanog, fast analysis (30 min), and simplicity. Furthermore, this approach has the potential to be adapted for the recognition of other antigen-antibody immune complexes by utilizing the corresponding antigens and their selective antibodies.


Asunto(s)
Biomarcadores de Tumor , Proteína Homeótica Nanog , Humanos , Inmunoensayo/métodos , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/inmunología , Biomarcadores de Tumor/análisis , Proteína Homeótica Nanog/inmunología , Células Madre Neoplásicas/inmunología , Límite de Detección , Mediciones Luminiscentes/métodos , Cobre/química , Anticuerpos Inmovilizados/inmunología , Oro/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química
16.
Mikrochim Acta ; 191(7): 418, 2024 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914884

RESUMEN

An electrochemical immunoassay system was developed to detect CA-125 using a glassy carbon electrode (GCE) modified with MXene, graphene quantum dots (GQDs), and gold nanoparticles (AuNPs). The combined MXene-GQD/AuNPs modification displayed advantageous electrochemical properties due to the synergistic effects of MXene, GQDs, and AuNPs. The MXene-GQD composite in the modified layer provided strong mechanical properties and a large specific surface area. Furthermore, the presence of AuNPs significantly improved conductivity and facilitated the binding of anti-CA-125 on the modified GCE, thereby enhancing sensitivity. Various analytical techniques such as FE-SEM and EDS were utilized to investigate the structural and morphological characteristics as well as the elemental composition. The performance of the developed immunosensor was assessed using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), square wave voltammetry (SWV), and differential pulse voltammetry (DPV). Under optimized conditions in a working potential range of -0.2 to 0.6 V (vs. Ag/AgCl), the sensitivity, linear range (LR), limit of detection (LOD), and correlation coefficient (R2) were determined to be 315.250 µA pU.mL-1/cm2, 0.1 to 1 nU/mL, 0.075 nU/mL, and 0.9855, respectively. The detection of CA-125 in real samples was investigated using the developed immunoassay platform, demonstrating satisfactory results including excellent selectivity and reproducibility.


Asunto(s)
Antígeno Ca-125 , Técnicas Electroquímicas , Oro , Grafito , Límite de Detección , Nanopartículas del Metal , Neoplasias Ováricas , Puntos Cuánticos , Antígeno Ca-125/sangre , Antígeno Ca-125/análisis , Oro/química , Nanopartículas del Metal/química , Humanos , Neoplasias Ováricas/sangre , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Inmunoensayo/métodos , Femenino , Puntos Cuánticos/química , Grafito/química , Anticuerpos Inmovilizados/inmunología , Técnicas Biosensibles/métodos , Electrodos , Proteínas de la Membrana
17.
Mikrochim Acta ; 191(8): 477, 2024 07 22.
Artículo en Inglés | MEDLINE | ID: mdl-39039391

RESUMEN

A novel biofuel cell (BFC)-based self-powered electrochemical immunosensing platform was developed by integrating the target-induced biofuel release and biogate immunoassay for ultrasensitive 17ß-estradiol (E2) detection. The carbon nanocages/gold nanoparticle composite was employed in the BFCs device as the electrode material, through which bilirubin oxidase and glucose oxidase were wired to form the biocathode and bioanode, respectively. Positively charged mesoporous silica nanoparticles (PMSN) were encapsulated with glucose molecules as biofuel and subsequently coated by the negatively charged AuNPs-labelled anti-E2 antibody (AuNPs-Ab) serving as a biogate. The biogate could be opened efficiently and the trapped glucose released once the target E2 was recognized and captured by AuNPs-Ab due to the decreased adhesion between the antigen-antibody complex and PMSN. Then, glucose oxidase oxidized the glucose to produce a large number of electrons, resulting in significantly increased open-circuit voltage (EOCV). Promisingly, the proposed BFC-based self-powered immunosensor demonstrated exceptional sensitivity for the detection of E2 in the concentration range from 1.0 pg mL-1 to 10.0 ng mL -1, with a detection limit of 0.32 pg mL-1 (S/N = 3). Furthermore, the prepared BFC-based self-powered homogeneous immunosensor showed significant potential for implementation as a viable prototype for a mobile and an on-site bioassay system in food and environmental safety applications.


Asunto(s)
Fuentes de Energía Bioeléctrica , Técnicas Biosensibles , Estradiol , Glucosa Oxidasa , Oro , Límite de Detección , Nanopartículas del Metal , Inmunoensayo/métodos , Estradiol/química , Estradiol/análisis , Oro/química , Glucosa Oxidasa/química , Técnicas Biosensibles/métodos , Nanopartículas del Metal/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Humanos , Electrodos , Glucosa/análisis , Oxidorreductasas actuantes sobre Donantes de Grupo CH-CH/química , Anticuerpos Inmovilizados/inmunología , Dióxido de Silicio/química , Enzimas Inmovilizadas/química
18.
Mikrochim Acta ; 191(2): 82, 2024 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-38191940

RESUMEN

A novel approach is presented that combines filtration and the direct immunomagnetic separation of the retained bacteria Legionella in filters, for further electrochemical immunosensing. This strategy allows for the separation and preconcentration of the water-borne pathogen from high-volume samples, up to 1000 mL. The limit of detection of the electrochemical immunosensor resulted in 100 CFU mL-1 and improved up to 0.1 CFU mL-1 when the preconcentration strategy was applied in 1 L of sample (103-fold improvement). Remarkably, the immunosensor achieves the limit of detection in less than 2.5 h and simplified the analytical procedure. This represents the lowest concentration reported to date for electrochemical immunosensing of Legionella cells without the need for pre-enrichment or DNA amplification. Furthermore, the study successfully demonstrates the extraction of bacteria retained on different filtering materials using immunomagnetic separation, highlighting the high efficiency of the magnetic particles to pull out the bacteria directly from solid materials. This promising feature expands the applicability of the method beyond water systems for detecting bacteria retained in air filters of air conditioning units by directly performing the immunomagnetic separation in the filters.


Asunto(s)
Técnicas Biosensibles , Legionella , Separación Inmunomagnética , Inmunoensayo , Bacterias , Agua
19.
Mikrochim Acta ; 191(2): 85, 2024 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-38195845

RESUMEN

A ratiometric electrochemical immunosensor is proposed for simultaneous detection of cellular-myelocytomatosis oncoprotein (C-myc) and B-cell lymphoma 2 (Bcl-2) via the potential-resolved strategy. It relied on multi-role co-loaded alloy composites (CLACs) and poly(3,4-ethylenedioxythiophene) (PEDOT)-graphene oxide (GO)-multiwalled carbon nanotubes (MWCNTs) (PGM) modified electrodes. CLACs with good catalytic and enzyme-like properties were synthesized in one step by loading tetramethylbenzidine (TMB) or methylene blue (MB) into Pt-Pd alloy and used as label materials. After immunological reactions, CLACs showed distinguishable dual differential pulse voltammetry signals at - 0.26 V and 0.38 V, corresponding to C-myc and Bcl-2, and the PGM had an electrochemical signal at 1.2 V, which could be used as a reference signal to construct a ratiometric sensor. CLACs had a satisfactory synergistic effect with the PGM, and eventually achieved quadruple signal amplification. Thus, benefiting from multiple magnification and ratiometric self-calibration functions, sensitive detections of C-myc and Bcl-2 were achieved, with detection limits as low as 0.5 and 2.5 pg mL-1, respectively. Additionally, when the designed method was applied to blood samples from lymphoma patients, results consistent with the ELISA kit were obtained. This will open avenues for constructing multiple protein detection sensors.


Asunto(s)
Técnicas Biosensibles , Nanotubos de Carbono , Humanos , Inmunoensayo , Aleaciones , Calibración
20.
Mikrochim Acta ; 191(2): 103, 2024 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-38231275

RESUMEN

A natural stress response induces elevated cortisol levels in biological fluids, such as saliva. While current sensor technologies can detect cortisol in real time, their sensitivity and reliability for human subjects have not been assured. This is due to relatively low concentrations of salivary cortisol, which fluctuate throughout the day and vary significantly between individuals. To address these challenges, we present an improved electrochemical biosensor leveraging graphene's exceptional conductivity and physicochemical properties. A 1-pyrenebutyric acid N-hydroxysuccinimide ester (PBASE-NHS)-modified commercial graphene foam (GF) electrode is presented to realize an ultra-sensitive biosensor for cortisol detection directly in human saliva. The biosensor fabrication process entails the attachment of anti-cortisol monoclonal antibodies (mAb-cort) onto a PBASE-NHS/GF electrode through noncovalent immobilization on the vertically stratified graphene foam electrode surface. This unique immobilization strategy preserves graphene's structural integrity and electrical conductivity while facilitating antibody immobilization. The binding of cortisol to immobilized mAb-cort is read out via differential pulse voltammetry using ferri/ferro redox reactions. The immunosensor demonstrates an exceptional dynamic range of 1.0 fg mL-1 to 10,000 pg mL-1 (R2 = 0.9914) with a detection limit of 0.24 fg mL-1 (n = 3) for cortisol. Furthermore, we have established the reliability of cortisol sensors in monitoring human saliva. We have also performed multiple modes of validation, one against the established enzyme-linked immunosorbent assay (ELISA) and a second by a third-party service Salimetric on 16 student volunteers exposed to different stress levels, showing excellent correlation (r = 0.9961). These findings suggest the potential for using mAb-cort/PBASE-NHS/GF-based cortisol electrodes for monitoring salivary cortisol in the general population.


Asunto(s)
Técnicas Biosensibles , Grafito , Pirenos , Humanos , Hidrocortisona , Inmunoensayo , Reproducibilidad de los Resultados , Ésteres
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA