Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Adv Wound Care (New Rochelle) ; 13(2): 70-82, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37534840

RESUMEN

Objective: Hydrolyzed collagen-based matrices are widely used as wound care dressings. Information on the mechanism of action of such dressings is scanty. The objective of this study was to test the effect of a specific hydrolyzed collagen powder (HCP), which is extensively used for wound care management in the United States. Approach: The effects of HCP on resolution of wound inflammation, perfusion, closure, and breaking strength of the repaired skin were studied in an experimental murine model. Results: In early (day 7) inflammatory phase of wound macrophages, HCP treatment boosted phagocytosis and efferocytosis of wound-site macrophages. In these cells, inducible reactive oxygen species were also higher on day (d) 7. HCP treatment potentiated the expression of anti-inflammatory interleukin (IL)-10 cytokine and proangiogenic vascular endothelial growth factor (VEGF) production. Excisional wounds dressed with HCP showed complete closure on day 21, while the control wounds remained open. HCP treatment also demonstrated improved quality of wound healing as marked by the improved breaking strength of the closed wound tissue/repaired skin. Innovation: These data represent first evidence on the mechanism of action of clinically used HCP. Conclusion: HCP dressing favorably influenced both wound inflammation and vascularization. Improved breaking strength of HCP-treated repaired skin lays the rationale for future studies testing the hypothesis that HCP-treated closed wounds would show fewer recurrences.


Asunto(s)
Colágeno , Factor A de Crecimiento Endotelial Vascular , Ratones , Animales , Polvos/farmacología , Colágeno/farmacología , Cicatrización de Heridas , Vendajes , Inflamación/metabolismo , Perfusión
2.
Int J Biol Macromol ; 239: 124268, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37003375

RESUMEN

Recently, the application of lignin activation by demethylation to improve reactivity and enrich multiple functions has intensively attracted attention. However, it is still challenge up to now due to the low reactivity and complexity of lignin structure. Here, an effective demethylation way was explored by microwave-assisted method for substantially enhancing the hydroxyl (-OH) content and retaining the structure of lignin. Then, the optimum demethylated lignin was used to removal heavy metal ions and promote wound healing, respectively. In detail, for microwave-assisted demethylated poplar lignin (M-DPOL), the contents of phenolic (Ar-OH) and total hydroxyl (Tot-OH) groups reached the maximum for 60 min at 90 °C in DMF with 7.38 and 9.13 mmol/g, respectively. After demethylation, with this M-DPOL as lignin-based adsorbent, the maximum adsorption capacity (Qmax) for Pb2+ ions reached 104.16 mg/g. Based on the isotherm, kinetic and thermodynamic models analyses, the chemisorption occurred in monolayer on the surface of M-DPOL, and all adsorption processes were endothermic and spontaneous. Meanwhile, M-DPOL as a wound dressing had excellent antioxidant property, outstanding bactericidal activity and remarkable biocompatibility, suggesting that it did not interfere with cell proliferation. Besides, the wounded rats treated with M-DPOL significantly promoted its formation of re-epithelialization and wound healing of full-thickness skin defects. Overall, microwave-assisted method of demethylated lignin can offer great advantages for heavy metal ions removal and wound care dressing, which facilitates high value application of lignin.


Asunto(s)
Metales Pesados , Contaminantes Químicos del Agua , Ratas , Animales , Lignina/química , Adsorción , Metales Pesados/química , Iones , Vendajes , Contaminantes Químicos del Agua/química , Cinética
3.
Adv Wound Care (New Rochelle) ; 8(4): 149-159, 2019 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-31016066

RESUMEN

Objective: To evaluate if patterned electroceutical dressing (PED) is safe for human chronic wounds treatment as reported by wound care providers. Approach: This work reports a pilot feasibility study with the primary objective to determine physically observable effects of PED application on host tissue response from a safety evaluation point of view. For this pilot study, patients receiving a lower extremity amputation with at least one open wound on the part to be amputated were enrolled. Patients were identified through the Ohio State University Wexner Medical Center (OSUWMC) based on inclusion and exclusion criteria through prescreening through the Comprehensive Wound Center's (CWC) Limb Preservation Program and wound physicians and/or providers at OSUWMC. Wounds were treated with the PED before amputation surgery. Results: The intent of the study was to identify if PED was safe for clinical application based on visual observations of adverse or lack of adverse events on skin and wound tissue. The pilot testing performed on a small cohort (N = 8) of patients showed that with engineered voltage regulation of current flow to the open wound, the PED can be used with little to no visually observable adverse effects on chronic human skin wounds. Innovation: The PED was developed as a second-generation tunable electroceutical wound care dressing, which could potentially be used to treat wounds with deeper infections compared with current state of the art that treats wounds with treatment zone limited to the surface near topical application. Conclusion: Technology advances in design and fabrication of electroceutical dressings were leveraged to develop a tunable laboratory prototype that could be used as a disposable low-cost electroceutical wound care dressing on chronic wounds. Design revisions of PED-1 (1 kΩ ballast resistor) circumvented previously observed adverse effects on the skin in the vicinity of an open wound. PED-10 (including a 10 kΩ ballast resistor) was well tolerated in the small cohort of patients (N = 8) on whom it was tested, and the observations reported here warrant a larger study to determine the clinical impact on human wound healing and infection control.

4.
Burns ; 40(6): 1164-71, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24485358

RESUMEN

Traditional wound dressings, including cotton gauze, absorbent pads and bandages, can cause trauma and pain to wounds during dressing changes, leading to a variety of physical and psychosocial sequelae. The aim of this study was to adapt an in vitro model of adherence to evaluate the effects of various methods to theoretically reduce the adherence of wound dressings. Gelatin in liquid form was cast onto poly(ethylene terephthalate) (PET) fabric and allowed to solidify and progressively dry to simulate wound desiccation in the clinical setting. A 180° peel test of PET from the gelatin slab yielded adherence data of peeling energy. The peeling energy of PET increased with the drying time. It was possible to reduce the force by drying at 75% relative humidity (RH). After drying for 24h, either 500µL of water or surfactant solution was added onto the PET surface (16×60mm(2)). The peeling energy decreased dramatically with wetting and there was no significant difference between water and surfactant. As a long-term strategy for decreasing adherence, a thin layer of polyacrylamide (PAM) hydrogel was deposited onto PET fabric via UV irradiation. This resulted in a much lower peeling energy without severely compromising fabric flexibility. This hydrogel layer could also serve as a reservoir for bioactive and antimicrobial agents which could be sustainably released to create a microbe-free microenvironment for optimized wound healing.


Asunto(s)
Vendajes , Quemaduras/terapia , Hidrogel de Polietilenoglicol-Dimetacrilato/uso terapéutico , Tereftalatos Polietilenos/uso terapéutico , Tensoactivos/uso terapéutico , Humanos , Modelos Biológicos , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA