Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 49(4): 966-974, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30252997

RESUMEN

BACKGROUND: Quantifying blood perfusion in ocular tissues is challenging, partly because the majority of the blood is carried by the choroid, which is difficult to visualize because it is located between the retina and sclera. PURPOSE/HYPOTHESIS: To evaluate the intra- and interday repeatability of MRI measures of chorio-retinal blood perfusion. STUDY TYPE: Prospective, cross-sectional, observational study. POPULATION: Twenty young healthy adults (six male, age: 25 ± 5 years) scanned twice within a single session repeated at the same time of day on 2 days. FIELD STRENGTH/SEQUENCE: Arterial spin labeling (ASL) MRI at 3.0T using pseudocontinuous ASL (PCASL) labeling scheme and a 3D turbo-gradient-spin-echo (TGSE) acquisition, including axial T2 -weighted structural images using a 2D turbo-spin-echo (TSE) sequence. ASSESSMENTS: Region-of-interest analysis for assessment of chorio-retinal blood perfusion. STATISTICAL TESTS: Intra- and interday repeatability of measures analyzed using intraclass correlation coefficients (ICC), Pearson's correlation analysis, paired t-tests, and Bland-Altman plots. RESULTS: The mean chorio-retinal perfusion was 77.86 (standard deviation [SD] = 29.80) ml/100ml/min. Perfusion measurements correlated strongly within a single session (r = 0.95, 95% confidence interval [CI] [0.880-0.980], P < 0.001) and between the two sessions based on a single run (r = 0.80 [0.582-0.913], P < 0.001), and two runs (r = 0.80 [0.479-0.918], P < 0.001). There were mean differences of 2.69 [16.85 to -22.23] ml/100ml/min for intraday measures, -7.44 [27.45 to -42.32] ml/100ml/min for single-run interday measures, and 5.73 [28.71 to -40.17] ml/100ml/min for two-run interday measures, but none were significant (all P > 0.05). DATA CONCLUSION: Quantitative ASL-MRI measurements of chorio-retinal blood perfusion showed high intra- and interday repeatability. The ASL-MRI technique provides reliable measures of chorio-retinal perfusion in vivo. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019;49:966-974.


Asunto(s)
Arterias/diagnóstico por imagen , Coroides/diagnóstico por imagen , Ojo/irrigación sanguínea , Ojo/diagnóstico por imagen , Imagen por Resonancia Magnética , Marcadores de Spin , Adulto , Circulación Cerebrovascular , Estudios Transversales , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Masculino , Perfusión , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA