Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Chromatographia ; 87(2)2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38435274

RESUMEN

Worldwide polystyrene (PS) production in 2020 was approximately 27 million metric tons, distributed among many nations, making it one of the most heavily imported and exported chemicals. Commercially produced PS usually possesses a broad molar mass distribution, often with a substantial oligomeric component. The latter can significantly affect processing and end-use, in addition to having potentially hazardous health effects and to impacting the polymer's export classification by regulatory agencies. Quantitation of the oligomeric region of polymers by size-exclusion chromatography with concentration-sensitive and/or static light scattering detection is complicated by the non-constancy of the specific refractive index increment (∂n/∂c) in this region, which affects the calculated amount (mass fraction) of oligomer in a polymer, molar mass averages, and related conclusions regarding macromolecular properties. Here, a multi-detector SEC approach including differential refractometry, multi-angle static light scattering, and differential viscometry has been applied to determining the ∂n/∂c of n-butyl terminated styrene oligomers at each degree of polymerization from monomer to hexamer, and also of a hexadecamer. Large changes in this parameter from one degree of polymerization to the next are observed, including but not restricted to the fact that the (∂n/∂c) of the monomer is less than half that of PS polymer at identical experimental conditions. As part of this study, the individual effects of injection volume, flow rate, and temperature on chromatographic resolution were examined. Incorporation of the on-line viscometer allowed for accurate determination of the intrinsic viscosity and viscometric radius of the monomer and oligomers.

2.
Sensors (Basel) ; 24(1)2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38202866

RESUMEN

Fabry-Pérot-based refractometry has demonstrated the ability to assess gas pressure with high accuracy and has been prophesized to be able to realize the SI unit for pressure, the pascal, based on quantum calculations of the molar polarizabilities of gases. So far, the technology has mostly been limited to well-controlled laboratories. However, recently, an easy-to-use transportable refractometer has been constructed. Although its performance has previously been assessed under well-controlled laboratory conditions, to assess its ability to serve as an actually transportable system, a ring-type comparison addressing various well-characterized pressure balances in the 10-90 kPa range at several European national metrology institutes is presented in this work. It was found that the transportable refractometer is capable of being transported and swiftly set up to be operational with retained performance in a variety of environments. The system could also verify that the pressure balances used within the ring-type comparison agree with each other. These results constitute an important step toward broadening the application areas of FP-based refractometry technology and bringing it within reach of various types of stakeholders, not least within industry.

3.
Molecules ; 28(11)2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37298836

RESUMEN

Medium polarity plays a crucial role in charge-transfer processes and electrochemistry. The added supporting electrolyte in electrochemical setups, essential for attaining the needed electrical conductivity, sets challenges for estimating medium polarity. Herein, we resort to Lippert-Mataga-Ooshika (LMO) formalism for estimating the Onsager polarity of electrolyte organic solutions pertinent to electrochemical analysis. An amine derivative of 1,8-naphthalimide proves to be an appropriate photoprobe for LMO analysis. An increase in electrolyte concentration enhances the polarity of the solutions. This effect becomes especially pronounced for low-polarity solvents. Adding 100 mM tetrabutylammonium hexafluorophosphate to chloroform results in solution polarity exceeding that of neat dichloromethane and 1,2-dichloroethane. Conversely, the observed polarity enhancement that emerges upon the same electrolyte addition to solvents such as acetonitrile and N,N-dimethylformamide is hardly as dramatic. Measured refractive indices provide a means for converting Onsager to Born polarity, which is essential for analyzing medium effects on electrochemical trends. This study demonstrates a robust optical means, encompassing steady-state spectroscopy and refractometry, for characterizing solution properties important for charge-transfer science and electrochemistry.

4.
J Dairy Sci ; 105(4): 2733-2749, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35094859

RESUMEN

It is critical that bovine maternal colostrum is fed to newborn calves during their first hours of life. Colostrum is the secretion a cow produces after mammary involution that is rich in various nutrients. In addition to the nutritive value for newborn calves, immunoglobulins are of interest due to their role in developing the naïve immune system of calves at birth. The process by which a calf acquires immunity via absorption of immunoglobulins is defined as passive immunity. When calves consume an adequate amount of immunoglobulins, they are classified as having successful passive immunity (SPI). In contrast, if they are deprived of adequate colostrum, they are considered to have had a failure of transfer of passive immunity (FPI). Transfer of passive immunity is assessed by measuring serum IgG concentrations at 24 to 48 h of age. The major factors that influence whether a calf has SPI or FPI are colostrum IgG concentration, quantity fed, and age of calf at colostrum feeding. Monitoring apparent efficiency of immunoglobulin absorption in calves is often recommended to evaluate overall colostrum management practices. Serum IgG analyses can be determined with direct (radial immunodiffusion) or indirect (refractometry) methods and used to assess SPI or FPI prevalence.


Asunto(s)
Calostro , Inmunoglobulina G , Animales , Animales Recién Nacidos , Bovinos , Femenino , Inmunodifusión/veterinaria , Parto , Embarazo
5.
Sensors (Basel) ; 22(23)2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36502253

RESUMEN

The design of a refractometric sensing system for liquids analysis with a sensor and the scheme for its intensity interrogation combined on a single photonic integrated circuit (PIC) is proposed. A racetrack microring resonator with a channel for the analyzed liquid formed on the top is used as a sensor, and another microring resonator with a lower Q-factor is utilized to detect the change in the resonant wavelength of the sensor. As a measurement result, the optical power at its drop port is detected in comparison with the sum of the powers at the through and drop ports. Simulations showed the possibility of registering a change in the analyte refractive index with a sensitivity of 110 nm per refractive index unit. The proposed scheme was analyzed with a broadband source, as well as a source based on an optoelectronic oscillator using an optical phase modulator. The second case showed the fundamental possibility of implementing an intensity interrogator on a PIC using an external typical single-mode laser as a source. Meanwhile, additional simulations demonstrated an increased system sensitivity compared to the conventional interrogation scheme with a broadband or tunable light source. The proposed approach provides the opportunity to increase the integration level of a sensing device, significantly reducing its cost, power consumption, and dimensions.


Asunto(s)
Óptica y Fotónica , Refractometría , Diseño de Equipo , Fotones , Luz
6.
Sensors (Basel) ; 22(18)2022 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-36146259

RESUMEN

Global navigation satellite system (GNSS) refractometry enables automated and continuous in situ snow water equivalent (SWE) observations. Such accurate and reliable in situ data are needed for calibration and validation of remote sensing data and could enhance snow hydrological monitoring and modeling. In contrast to previous studies which relied on post-processing with the highly sophisticated Bernese GNSS processing software, the feasibility of in situ SWE determination in post-processing and (near) real time using the open-source GNSS processing software RTKLIB and GNSS refractometry based on the biased coordinate Up component is investigated here. Available GNSS observations from a fixed, high-end GNSS refractometry snow monitoring setup in the Swiss Alps are reprocessed for the season 2016/17 to investigate the applicability of RTKLIB in post-processing. A fixed, low-cost setup provides continuous SWE estimates in near real time at a low cost for the complete 2021/22 season. Additionally, a mobile, (near) real-time and low-cost setup was designed and evaluated in March 2020. The fixed and mobile multi-frequency GNSS setups demonstrate the feasibility of (near) real-time SWE estimation using GNSS refractometry. Compared to state-of-the-art manual SWE observations, a mean relative bias below 5% is achieved for (near) real-time and post-processed SWE estimation using RTKLIB.


Asunto(s)
Refractometría , Nieve , Sistemas de Información Geográfica , Estaciones del Año , Agua
7.
Int J Mol Sci ; 24(1)2022 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-36613663

RESUMEN

Mutations in GPR179 are one of the most common causes of autosomal recessive complete congenital stationary night blindness (cCSNB). This retinal disease is characterized in patients by impaired dim and night vision, associated with other ocular symptoms, including high myopia. cCSNB is caused by a complete loss of signal transmission from photoreceptors to ON-bipolar cells. In this study, we hypothesized that the lack of Gpr179 and the subsequent impaired ON-pathway could lead to myopic features in a mouse model of cCSNB. Using ultra performance liquid chromatography, we show that adult Gpr179-/- mice have a significant decrease in both retinal dopamine and 3,4-dihydroxyphenylacetic acid, compared to Gpr179+/+ mice. This alteration of the dopaminergic system is thought to be correlated with an increased susceptibility to lens-induced myopia but does not affect the natural refractive development. Altogether, our data added a novel myopia model, which could be used to identify therapeutic interventions.


Asunto(s)
Enfermedades Genéticas Ligadas al Cromosoma X , Miopía , Ceguera Nocturna , Ratones , Animales , Electrorretinografía/métodos , Ceguera Nocturna/genética , Retina , Miopía/genética , Enfermedades Genéticas Ligadas al Cromosoma X/genética , Receptores Acoplados a Proteínas G/genética
8.
Arch Microbiol ; 203(1): 193-204, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32803346

RESUMEN

The study focused on the production of wine from date palm fruits (Phoenix dactylifera L.) using a strain of yeast isolated from selected Nigerian locally fermented beverages ('pito', 'brukutu' and palm wine). Seven (7) distinct yeasts were isolated and identified using cultural, microscopy and biochemical tests (temperature tolerance, flocculation, ethanol tolerance, H2S production and killer toxin production and the ability to assimilate and ferment sugars. The yeast isolates were screened using refractometric and spectrophotometric methods to select the isolate with the best ability for wine production. This isolate was molecularly characterized, grown in 1 L of potatoes dextrose broth, freeze dried and used for wine production. The population of yeast, bacteria and the physicochemical analysis of the must were monitored during fermentation. Populations of bacteria in the wine were assessed by standard pour plate count. The proximate content and physicochemical properties of the produced wine before and after ageing, as well as the sensorial quality of the produced wine was determined. All the yeast isolates possessed the ability to flocculate, tolerate ethanol concentration of between 5 and 20% and temperature range of 30-45 °C, produced low concentration of H2S and does not produce killer toxins. A palm wine isolate, identified as Saccharomyces cerevisiae X01 was selected as the best isolate with the most ability for wine production. The total yeast count increases as the period of fermentation progressed while the total viable bacterial count reduced as the fermentation period progressed. There was a significant difference (P < 0.05) in the physicochemical properties of the must during fermentation. At the end of the fermentation, the produced wine had 5.22% and 4.86% ethanol content for S. cerevisiae QA23 and S. cerevisiae X01 respectively. There was no significant difference (P > 0.05) between the proximate and physicochemical compositions of the produced wine before and after ageing using Saccharomyces cerevisiae X01 when compared to the control S. cerevisiae QA23. This study revealed that the Nigerian locally sourced S. cerevisiae X01 can be used as an alternative substrate for industrial scale production of wine with a mild alcoholic content.


Asunto(s)
Fermentación , Alimentos Fermentados/microbiología , Microbiología de Alimentos , Phoeniceae , Saccharomyces cerevisiae/metabolismo , Vino/microbiología , Etanol/análisis , Frutas/metabolismo , Frutas/microbiología , Nigeria , Phoeniceae/microbiología , Saccharomyces cerevisiae/aislamiento & purificación
9.
Sensors (Basel) ; 21(18)2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34577478

RESUMEN

Refractometry is a powerful technique for pressure assessments that, due to the recent redefinition of the SI system, also offers a new route to realizing the SI unit of pressure, the Pascal. Gas modulation refractometry (GAMOR) is a methodology that has demonstrated an outstanding ability to mitigate the influences of drifts and fluctuations, leading to long-term precision in the 10-7 region. However, its short-term performance, which is of importance for a variety of applications, has not yet been scrutinized. To assess this, we investigated the short-term performance (in terms of precision) of two similar, but independent, dual Fabry-Perot cavity refractometers utilizing the GAMOR methodology. Both systems assessed the same pressure produced by a dead weight piston gauge. That way, their short-term responses were assessed without being compromised by any pressure fluctuations produced by the piston gauge or the gas delivery system. We found that the two refractometer systems have a significantly higher degree of concordance (in the 10-8 range at 1 s) than what either of them has with the piston gauge. This shows that the refractometry systems under scrutiny are capable of assessing rapidly varying pressures (with bandwidths up to 2 Hz) with precision in the 10-8 range.


Asunto(s)
Refractometría , Torso
10.
Anal Bioanal Chem ; 412(14): 3317-3349, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32313998

RESUMEN

Direct optical detection has proven to be a highly interesting tool in biomolecular interaction analysis to be used in drug discovery, ligand/receptor interactions, environmental analysis, clinical diagnostics, screening of large data volumes in immunology, cancer therapy, or personalized medicine. In this review, the fundamental optical principles and applications are reviewed. Devices are based on concepts such as refractometry, evanescent field, waveguides modes, reflectometry, resonance and/or interference. They are realized in ring resonators; prism couplers; surface plasmon resonance; resonant mirror; Bragg grating; grating couplers; photonic crystals, Mach-Zehnder, Young, Hartman interferometers; backscattering; ellipsometry; or reflectance interferometry. The physical theories of various optical principles have already been reviewed in detail elsewhere and are therefore only cited. This review provides an overall survey on the application of these methods in direct optical biosensing. The "historical" development of the main principles is given to understand the various, and sometimes only slightly modified variations published as "new" methods or the use of a new acronym and commercialization by different companies. Improvement of optics is only one way to increase the quality of biosensors. Additional essential aspects are the surface modification of transducers, immobilization strategies, selection of recognition elements, the influence of non-specific interaction, selectivity, and sensitivity. Furthermore, papers use for reporting minimal amounts of detectable analyte terms such as value of mass, moles, grams, or mol/L which are difficult to compare. Both these essential aspects (i.e., biochemistry and the presentation of LOD values) can be discussed only in brief (but references are provided) in order to prevent the paper from becoming too long. The review will concentrate on a comparison of the optical methods, their application, and the resulting bioanalytical quality.


Asunto(s)
Técnicas Biosensibles/instrumentación , Dispositivos Ópticos , Animales , Técnicas Biosensibles/métodos , Diseño de Equipo , Humanos , Interferometría/instrumentación , Interferometría/métodos , Luz , Refractometría/instrumentación , Refractometría/métodos , Resonancia por Plasmón de Superficie/instrumentación , Resonancia por Plasmón de Superficie/métodos , Transductores
11.
Vet Anaesth Analg ; 46(5): 579-586, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31401048

RESUMEN

OBJECTIVE: To determine if low molecular weight synthetic colloid fluids administered to dogs interfere with refractometric estimates of total plasma protein (TPPr) and urine osmolality (UOsm). STUDY DESIGN: Experimental study. ANIMALS: Eighteen healthy Greyhound dogs. METHODS: Anaesthetized Greyhounds subjected to haemorrhage for 60 minutes were given 80 mL kg-1 of Plasma-Lyte 148 (CRYST), or 20 mL kg-1 of hydroxyethyl starch 130/0.4 (HES) or succinylated gelatine (GELO) (n = 6 per group) intravenously over 20 minutes. Refractometric (TPPr) and biuret total plasma protein (TPPb) were measured before haemorrhage (Baseline), at end of shock (Shock), immediately (T20), then 40 minutes (T60), 100 minutes (T120) and 160 minutes (T180) after fluid administration. Urine specific gravity (USG) and UOsm were measured at all time points except T20. Estimated UOsm (eUOsm) was calculated from USG. Bias and limits of agreement (LOA) for TPPr versus TPPb, and eUOsm versus UOsm were calculated at each time point. RESULTS: For dogs given CRYST and GELO, median TPPr and TPPb decreased in parallel, with a small consistent TPP bias (CRYST range of bias, 0.38-0.67 g dL-1; GELO range of bias, 0.42-0.58 g dL-1). Dogs given HES showed divergence between median TPPr and TPPb after T20, with a peak bias at T20 of 1.62 g dL-1 (LOA 1.29-1.95). Dogs given HES and GELO had markedly increased USG [HES peak median USG at T180 of 1.119 (Q1-Q3 1.103-1.122); GELO peak median USG at T120 of 1.114 (Q1-Q3 1.082-1.119)], with large increases in bias between eUOsm and UOsm [HES peak bias at T60 of 2995 mOsm kg-1 (LOA 2032-3958 mOsm kg-1); GELO peak bias at T120 of 2465 mOsm kg-1 (LOA 940-3990 mOsm kg-1)]. CONCLUSIONS AND CLINICAL RELEVANCE: Administration of HES and GELO to dogs with haemorrhagic shock interferes with refractometric measurements for at least 3 hours after administration.


Asunto(s)
Enfermedades de los Perros/tratamiento farmacológico , Gelatina/uso terapéutico , Derivados de Hidroxietil Almidón/uso terapéutico , Choque Hemorrágico/veterinaria , Succinatos/uso terapéutico , Animales , Perros , Femenino , Fluidoterapia/veterinaria , Gelatina/administración & dosificación , Gelatina/farmacología , Derivados de Hidroxietil Almidón/administración & dosificación , Derivados de Hidroxietil Almidón/farmacología , Masculino , Refractometría/veterinaria , Choque Hemorrágico/tratamiento farmacológico , Succinatos/administración & dosificación , Succinatos/farmacología , Orina/química
12.
Acta Vet Hung ; 66(4): 573-586, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30580538

RESUMEN

Twenty-eight warmblood mares were monitored during their late pregnancy in the Teaching Hospital of Ghent University. The reliability of two commercial assays (enzyme immunoassay and glutaraldehyde coagulation test) used for determining the IgG concentrations of their newborn foals was tested. Mammary secretions were examined at the time of foaling (T0), and then 4 (T1) and 8 (T2) hours after foaling by refractometry and electrophoresis. The foals' blood IgG levels were measured at T1 and T2 as a routine clinical diagnostic examination using two different commercial test kits (SNAP Foal Ig and Gamma-Check E) and T0, T1 and T2 samples were stored (at -18 °C) for immunoglobulin (Ig) determination by electrophoresis. Differences between the results of refractometry and electrophoresis occurred in 27.8% of the colostrum analyses. Some serum IgG could be detected immediately post partum (T0) in 75% of the foals, and 42.82% of the newborn foals acquired a serum concentration of more than 800 mg/dl IgG within 8 h of birth. Compared to the electrophoresis, the glutaraldehyde test scored better (85%) than the enzyme immunoassay (74%), although both are accurate and safe to use since they clearly distinguish between safe and unsafe IgG concentrations.


Asunto(s)
Pruebas de Coagulación Sanguínea/veterinaria , Pruebas Diagnósticas de Rutina/veterinaria , Electroforesis/veterinaria , Ensayo de Inmunoadsorción Enzimática/veterinaria , Refractometría/veterinaria , Animales , Animales Recién Nacidos , Pruebas de Coagulación Sanguínea/métodos , Calostro/química , Pruebas Diagnósticas de Rutina/métodos , Electroforesis/métodos , Ensayo de Inmunoadsorción Enzimática/métodos , Glutaral/química , Caballos , Inmunoglobulina G/sangre , Refractometría/métodos , Reproducibilidad de los Resultados
13.
J Dairy Sci ; 100(7): 5774-5781, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28478013

RESUMEN

The objective of this study was to evaluate colostrum IgG concentration harvested at first and second milking from multiparous Jersey cows, the dam's lactation number, colostrum yield, and time of first milking. In addition, we validated the use of a Brix refractometer to estimate IgG concentration in colostrum from multiparous Jersey cows using radial immunodiffusion as the reference method. Colostrum samples and total weight of colostrum harvested at first (n = 134) and second (n = 68) milking were collected from 134 multiparous Jersey cows housed in a California herd. Fresh colostrum samples were analyzed for IgG concentration with Brix refractometry and frozen samples by radial immunodiffusion. A total of 90.4 and 42.7% of the samples from first and second milking met industry standards of quality for IgG concentration (>50 g/L). Second and third lactation cows had similar colostrum IgG concentration but lower than cows on their fourth and greater lactation. At second milking, 56.4% of cows on their fourth or greater lactation had colostrum IgG concentrations >50 g/L. When colostrum yield increased from low (<3 kg), medium (3 to 6 kg), to high (>6 kg), IgG concentration decreased. Higher IgG concentration was observed on colostrum harvested at <6 h (short) versus 6 to 11 h (medium) after calving. However, IgG concentration in colostrum harvested after 11 h (long) was similar to that harvested at short and medium time. Readings of %Brix were highly correlated with IgG at first (r = 0.81) and second (r = 0.77) milking. The best Brix threshold to identify colostrum from first milking with >50 IgG g/L was 20.9% based on logit equations with Youden's index criterion and 18.0% based on accuracy criterion. For colostrum harvested at second milking, similar Brix thresholds were obtained, 19.2 and 19.0%, regardless of whether Youden's index or accuracy was used as the selection criterion. Our results indicate that the dam's lactation number, colostrum yield, and time of first milking relative to calving are associated with IgG concentration in colostrum from multiparous Jersey cows. Second milking colostrum from mature Jersey cows should be evaluated to extend colostrum supply on dairies especially during times of shortage. Readings of %Brix can be used to rapidly estimate IgG concentration in Jersey colostrum harvested at first and second milking.


Asunto(s)
Calostro/inmunología , Inmunoglobulina G/análisis , Paridad , Animales , California , Bovinos , Calostro/metabolismo , Femenino , Inmunodifusión/veterinaria , Embarazo , Refractometría/instrumentación , Refractometría/veterinaria
14.
J Dairy Sci ; 100(10): 8438-8442, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28755946

RESUMEN

Previous data have demonstrated that refractometers can be used to estimate serum IgG, and that a cut-point of 7.8% Brix should be used to identify failure of passive transfer (FPT) in 1-d-old Holstein calves. The objective of the present study was to validate the use of refractometry to estimate serum IgG concentrations and evaluate FPT in Jersey calves. Blood samples (n = 97) were obtained from 1- to 3-d-old Jersey calves and centrifuged at 3,300 × g for 20 min at 25°C. Serum was analyzed for % Brix, total protein (TP), and refractive index (nD) using a Sper Scientific Digital Refractometer (model #300036, Sper Scientific, Scottsdale, AZ) within 12 h of sampling. Samples were then frozen and later analyzed in the laboratory for IgG by radial immunodiffusion. The mean serum IgG concentration for all calves was 23.7 mg/mL (SD = 12.5), with a range of 2.3 to 65.5 mg/mL. Mean serum % Brix was 8.9 (SD = 1.1; range 6.5 to 12.0). Serum % Brix was moderately correlated with IgG concentration (r = 0.77). Total protein and IgG were moderately correlated (r = 0.790). Regression was used to determine cut-points for approximately 10, 12, and 14 mg of IgG/mL and to determine the sensitivity and specificity of refractometry to identify FPT (serum IgG <10 mg/mL at 24 h of life). Brix cut-points analyzed were 7.1, 7.3, and 7.6%; TP cut-points were 4.6, 5.0, and 5.5 g/dL; and nD cut-points were 1.34332, 1.34271, and 1.3448, respectively, for 10, 12, and 14 mg of IgG/mL. The 7.3% Brix and 4.6 g/dL TP cut-points resulted in the greatest percentage of samples being correctly classified. These data suggest that digital refractometry is an acceptable and rapid method to estimate immunoglobulin G in Jersey calf serum.


Asunto(s)
Inmunidad Colectiva , Inmunización Pasiva/veterinaria , Inmunoglobulina G/sangre , Refractometría/veterinaria , Animales , Animales Recién Nacidos , Bovinos , Calostro , Congelación , Inmunización Pasiva/métodos , Inmunodifusión/métodos , Inmunodifusión/veterinaria , Refractometría/instrumentación , Sensibilidad y Especificidad
15.
Chromatographia ; 80(6): 989-996, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28860670

RESUMEN

The specific refractive index increment (∂n/∂c) is an essential datum for the accurate quantitation of molar mass averages and distributions (inter alia) of macromolecules when refractometry, static light scattering, and/or viscometry detection are coupled on-line to size-based separation techniques. The latter include methods such as size-exclusion and hydrodynamic chromatography, and asymmetric and hollow-fiber flow field-flow fractionation. The ∂n/∂c is also needed for accurate determination of the weight-average molar mass of polymers by off-line, batch-mode multi-angle static light scattering. However, not only does ∂n/∂c differ among chemical species, it also depends on experimental conditions such as solvent, temperature, and wavelength. For the last seventeen years, the author's laboratories have measured the ∂n/∂c of a variety of natural and synthetic polymers, at both 690 nm and, more recently, 660 nm, under a variety of solvent and temperature conditions. In all cases, this has been done by off-line, batch-mode differential refractometry, not by assuming 100% analyte column recovery and 100% accurate peak integration. Results of these determinations are presented here, along with the relevant experimental data.

16.
Vet Anaesth Analg ; 41(4): 386-92, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24330264

RESUMEN

OBJECTIVE: To assess agreement between infrared (IR) analysers and a refractometer for measurements of isoflurane, sevoflurane and desflurane concentrations and to demonstrate the effect of customized calibration of IR analysers. STUDY DESIGN: In vitro experiment. SUBJECTS: Six IR anaesthetic monitors (Datex-Ohmeda) and a single portable refractometer (Riken). METHODS: Both devices were calibrated following the manufacturer's recommendations. Gas samples were collected at common gas outlets of anaesthesia machines. A range of agent concentrations was produced by stepwise changes in dial settings: isoflurane (0-5% in 0.5% increments), sevoflurane (0-8% in 1% increments), or desflurane (0-18% in 2% increments). Oxygen flow was 2 L minute(-1) . The orders of testing IR analysers, agents and dial settings were randomized. Duplicate measurements were performed at each setting. The entire procedure was repeated 24 hours later. Bland-Altman analysis was performed. Measurements on day-1 were used to yield calibration equations (IR measurements as dependent and refractometry measurements as independent variables), which were used to modify the IR measurements on day-2. RESULTS: Bias ± limits of agreement for isoflurane, sevoflurane and desflurane were 0.2 ± 0.3, 0.1 ± 0.4 and 0.7 ± 0.9 volume%, respectively. There were significant linear relationships between differences and means for all agents. The IR analysers became less accurate at higher gas concentrations. After customized calibration, the bias became almost zero and the limits of agreement became narrower. CONCLUSIONS AND CLINICAL RELEVANCE: If similar IR analysers are used in research studies, they need to be calibrated against a reference method using the agent in question at multiple calibration points overlapping the range of interest.


Asunto(s)
Anestésicos por Inhalación/química , Isoflurano/análogos & derivados , Isoflurano/química , Éteres Metílicos/química , Refractometría/instrumentación , Espectrofotometría Infrarroja/instrumentación , Animales , Desflurano , Monitoreo Intraoperatorio , Sevoflurano
17.
Int J Pharm ; 653: 123890, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38346601

RESUMEN

In this work, the optical imaging based single particle analysis (SPA) and the gold standard shake-flask (SF) solubility methods are compared. We show that to analyze pharmaceutical compounds spanning 7 log units in solubility and a diverse chemical space with limited resources, several analytical techniques are required (HPLC-UV, LC-MS, refractometry and UV-Vis spectrometry), whereas solely the SPA method is able to analyze all the same compounds. SPA experiments take only minutes, while for SF, it may take days to reach thermodynamic equilibration. This decreases the time span needed for the solubility experiment from initial preparations to obtaining the result from roughly three days to less than three hours. The optimal particle size for SPA ranges from approximately one to hundreds of microns. Challenges include measuring large particles, very fast dissolving compounds and handling small sample sizes. Inherent exclusion of density from the SPA measurement is a potential source of error for compounds with very low or high density values. The average relative difference of 37 % between the two methods is very good in the realm of solubility, where 400 % interlaboratory reproducibility can be expected.


Asunto(s)
Solubilidad , Reproducibilidad de los Resultados , Cromatografía de Gases y Espectrometría de Masas , Cromatografía Líquida de Alta Presión , Termodinámica , Preparaciones Farmacéuticas
18.
Front Vet Sci ; 11: 1383379, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38863449

RESUMEN

Introduction: The transfer of immunoglobulins from the mother to newborns is widely recognized as a critical event for safeguarding offspring against potentially life-threatening infectious diseases. Mainly for this reason, this study aimed to assess the concentrations of immunoglobulin G (IgG) and immunoglobulin A (IgA) in the saliva of newborn calves and explore its potential use for monitoring passive immunity transfer from cows to calves, as also to evaluate how colostrum intake affects serum and saliva IgG and IgA concentrations. Methods: The quality of colostrum samples was evaluated using an optical refractometer before administration to the calves. Saliva and blood samples from 24 calves were obtained at the day of birth (T0) and 2 days after (T2) for determination of serum concentrations of total protein by refractometer, IgG and IgA (both on serum and saliva) by ELISA test. Results: Positive correlations were observed between salivary IgA at T2 and salivary IgG at T2. A significant increase in both IgG and IgA levels in calf serum and saliva was noted. Salivary IgA levels can reflect salivary IgG levels. Discussion: These findings suggest the potential utility of IgA in monitoring passive immunity transfer, and do not exclude saliva as an alternative, practical, and non-invasive matrix for assessing passive immunity transfer.

19.
Animal ; 18(8): 101246, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-39079312

RESUMEN

This experiment was motivated by the need to understand the impacts of delaying the first colostrum feeding on the prevalence of failed transfer of passive immunity (FTPI). A cohort of 216 kids was stratified into groups based on the colostrum feeding delay postbirth: 0-4 h, 4-8 h, 8-12 h, and 12-16 h. All kids received a single colostrum meal of 300 mL, and blood samples were collected approximately 36 h after feeding. Serum immunoglobulin G (SIgG) was measured using ELISA, and serum total protein (STP) was assessed using the Bradford method and refractometry (STPb and STPr). Statistical methods like Pearson correlations, Bland-Altman plots, and Lin's concordance coefficient were employed to assess associations and agreements between SIgG, STPb and STPr. Receiver operator characteristic analysis was employed to determine optimal STPb and STPr thresholds for predicting FTPI (SIgG < 12 g/L). Subsequently, areas under the curve, sensitivity, and specificity were examined to assess the accuracy of these thresholds. Our results showed that for each hour's delay from birth to colostrum intake (up to 16 h), IgG apparent efficiency of absorption (AEA) decreases at an approximate rate of 2.0% per hour, and SIgG decreases at an approximate rate of 1.0 g/L per hour. However, this decline is not constant over time but intensifies progressively with increased feeding delay. Specifically, reductions in IgG AEA were 1.3, 2.9, and 5.9% per hour, and decreases in SIgG were 0.2, 0.3, and 0.7 g per hour for SIgG across the time intervals of 0-4 to 4-8 h, 4-8 to 8-12 h, and 8-12 to 12-16 h, respectively. Additionally, there was an increase in SIgG of 1.2 g/dL but a decrease in IgG AEA of 1.9% for each gram per kg of BW increase in IgG intake. The correlations between SIgG and STPr and STPb were 0.62, and 0.36, respectively. Optimal STPr and STPb thresholds predicting FTPI were determined to be 4.6 and 6.2 g/dL. The prevalence of FTPI, according to SIgG, STPr, and STPb thresholds were 63, 62, and 45%. Overall, STPr showed higher values for key performance metrics (i.e., sensitivity, likelihood ratio of positive tests, overall accuracy, and Youden's index), indicating better prediction ability than STPb. Our findings corroborate the critical importance of swift colostrum administration, ideally occurring no later than 12 h postbirth. Moreover, our research validates the effectiveness of Brix refractometry as a practical, on-farm method for assessing FTPI in goat kids.

20.
ACS Sens ; 9(6): 3027-3036, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38864606

RESUMEN

Surface plasmon (SP) excitation in metal-coated tilted fiber Bragg gratings (TFBGs) has been a focal point for highly sensitive surface biosensing. Previous efforts focused on uniform metal layer deposition around the TFBG cross section and temperature self-compensation with the Bragg mode, requiring both careful control of the core-guided light polarization and interrogation over most of the C + L bands. To circumvent these two important practical limitations, we studied and developed an original platform based on partially coated TFBGs. The partial metal layer enables the generation of dual-comb resonances, encompassing highly sensitive (TM/EH mode families) and highly insensitive (TE/HE mode families) components in unpolarized transmission spectra. The interleaved comb of insensitive modes acts as wavelength and power references within the same spectral region as the SP-active modes. Despite reduced fabrication and measurement complexity, refractometric accuracy is not compromised through statistical averaging over seven individual resonances within a narrowband window of 10 nm. Consequently, measuring spectra over 60 nm is no longer needed to compensate for small temperature or power fluctuations. This sensing platform brings the following important practical assets: (1) a simpler fabrication process, (2) no need for polarization control, (3) limited bandwidth interrogation, and (4) maintained refractometric accuracy, which makes it a true game changer in the ever-growing plasmonic sensing domain.


Asunto(s)
Fibras Ópticas , Resonancia por Plasmón de Superficie , Resonancia por Plasmón de Superficie/instrumentación , Resonancia por Plasmón de Superficie/métodos , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Tecnología de Fibra Óptica/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA