Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 231
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
AAPS PharmSciTech ; 25(1): 20, 2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38267637

RESUMEN

The aim of this paper was to investigate the effects of formulation parameters on the physicochemical and pharmacokinetic (PK) behavior of amorphous printlets of lopinavir (LPV) manufactured by selective laser sintering 3D printing method (SLS). The formulation variables investigated were disintegrants (magnesium aluminum silicate at 5-10%, microcrystalline cellulose at 10-20%) and the polymer (Kollicoat® IR at 42-57%), while keeping printing parameters constant. Differential scanning calorimetry, X-ray powder diffraction, and Fourier-transform infrared analysis confirmed the transformation of the crystalline drug into an amorphous form. A direct correlation was found between the disintegrant concentration and dissolution. The dissolved drug ranged from 71.1 ± 5.7% to 99.3 ± 2.7% within 120 min. A comparative PK study in rabbits showed significant differences in the rate and extent of absorption between printlets and compressed tablets. The values for Tmax, Cmax, and AUC were 4 times faster, and 2.5 and 1.7 times higher in the printlets compared to the compressed tablets, respectively. In conclusion, the SLS printing method can be used to create an amorphous delivery system through a single continuous process.


Asunto(s)
Excipientes , Rayos Láser , Animales , Conejos , Preparaciones Farmacéuticas , Disponibilidad Biológica , Lopinavir , Impresión Tridimensional
2.
BMC Oral Health ; 24(1): 845, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060942

RESUMEN

BACKGROUND: The fit of a metal-ceramic restoration is essential to its long-term durability. Regarding marginal and internal fit, there is not enough information about the technologies used in the production of metal-ceramic restorations. The aim of this in vitro study is to compare, both before and after porcelain firing, the marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations manufactured using casting, additive or subtractive computer-aided design, and computer-aided manufacturing techniques (CAD/CAM). METHODS: CAD/CAM were used to create 50 prepared maxillary first molar-shaped Co-Cr die models, which were randomly divided into 5 groups (n = 10). Cobalt-chrome copings were produced by casting (C), hard metal milling (HM), soft metal milling (SM), selective laser melting (SLM), and selective laser sintering (SLS) techniques. Before and after porcelain firing, discrepancies of the copings were measured using the silicone replica technique. The data obtained by measurements with a stereomicroscope at x80 magnification were analyzed statistically in the SPSS program. The ROBUST three-way analysis of variance (ANOVA) method was used to compare the discrepancy values. RESULTS: There were statistically significant differences among fabrication methods (P < .001). The HM method showed the highest discrepancy (90.1 µm), and the C (63 µm) method showed the lowest discrepancy in terms of the die model- crown fit. The C, SLS, and SM methods (63 µm; 61.6 µm; 67.7 µm) were statistically similar (P > .001). The highest discrepancy was observed on the occlusal area (87.1 µm), and the lowest discrepancy was observed on the axial area (47.7 µm) of the coping. Porcelain firing had a decrease in the discrepancy values (P = .001). CONCLUSION: All CAD/CAM techniques are appropriate for clinical use; selective laser sintering and soft milling can be the more recommended methods for the compatibility of metal-porcelain restorations, as they have lower discrepancy values than the SLM and HM methods.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Porcelana Dental , Diseño de Prótesis Dental , Aleaciones de Cerámica y Metal , Aleaciones de Cerámica y Metal/química , Porcelana Dental/química , Humanos , Técnica de Colado Dental , Adaptación Marginal Dental , Técnicas In Vitro , Aleaciones de Cromo/química
3.
Small ; 19(40): e2301426, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37271895

RESUMEN

In the system of magnesium-loaded scaffolds, the effect of magnesium ions (Mg2+ ) on the osteogenesis induction is restricted due to the low transmembrane transport efficiency of Mg2+ into the cell, which limits the application for bone defect repair. Inspired by the fact that magnetic field can regulate ion channel proteins on the cell membrane, magnetite nanoparticle is introduced into the poly (l-lactic acid) /magnesium oxide composite in this study, and a magnetic magnesium-loaded bone scaffold is prepared via selective laser sintering . Notably, the activities of the Mg2+ channel protein (MAGT1) on the membrane of bone marrow mesenchymal stem cells (rBMSCs) are enhanced via magnetic torque effect (via integrin αV ß3/actin), under the action of static magnetic field (SMF), which promoted rBMSCs to capture Mg2+ in the microenvironment and induced osteogenesis. In vitro experiments showed that the magnetic magnesium-loaded scaffold, under the action of SMF, can accelerate the inflow of Mg2+ from surrounding microenvironment, which improved cellular activities, osteogenesis-related gene expression (ALP, Runx2, OCN, and OPN), and mineralization. Besides, in vivo skull defect repair experiments showed that the scaffolds possessed good ability to promote bone differentiation and new bone regeneration.


Asunto(s)
Magnesio , Andamios del Tejido , Magnesio/farmacología , Osteogénesis , Regeneración Ósea , Cráneo , Diferenciación Celular , Iones , Campos Magnéticos , Ingeniería de Tejidos
4.
Clin Oral Investig ; 27(6): 2465-2481, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37017759

RESUMEN

OBJECTIVES: The aim of this review to overview three-dimensional (3D) printing technologies available for different dental disciplines, considering the applicability of such technologies and materials development. MATERIALS AND METHODS: Source Arksey and O'Malley's five stages framework using PubMed, EMBASE, and Scopus (Elsevier) databases managed this review. Papers focusing on 3D printing in dentistry and written in English were screened. Scientific productivity by the number of publications, areas of interest, and the focus of the investigations in each dental discipline were extracted. RESULTS: Nine hundred thirty-four studies using 3D printing in dentistry were assessed. Limited clinical trials were observed, especially in Restorative, endodontics, and pediatric dentistry. Laboratory or animal studies are not reliable for clinical success, suggesting that clinical trials are a good approach to validate the new methods' outcomes and ensure that the benefits outweigh the risk. The most common application for 3D printing technologies is to facilitate conventional dental procedures. CONCLUSIONS: The constantly improving quality of 3D printing applications has contributed to increasing the popularity of these technologies in dentistry; however, long-term clinical studies are necessary to assist in defining standards and endorsing the safe application of 3D printing in dental practice. CLINICAL RELEVANCE: The recent progress in 3D materials has improved dental practice capabilities over the last decade. Understanding the current status of 3D printing in dentistry is essential to facilitate translating its applications from laboratory to the clinical setting.


Asunto(s)
Endodoncia , Impresión Tridimensional , Humanos , Odontología Pediátrica , Atención Odontológica
5.
AAPS PharmSciTech ; 24(6): 171, 2023 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-37566167

RESUMEN

The aim of this work was to design pediatric-friendly, dose-flexible orally disintegrating drug delivery systems (printlets) of the antiviral drug tenofovir disoproxil fumarate (TDF) by selective laser sintering (SLS) for potential use in hospitals along with other antiviral drugs. In order to obtain a consistent quality of printlets with desired properties, it is important to understand certain critical quality attributes for their main and interactions effect. The printlets were optimized by Box-Behnken's design of the experiment by varying process variables while keeping the composition constant. The composition contained 16.3% TDF, 72.7% polyvinyl pyrrolidone K16-18, 8% magnesium aluminum silicate, 3% Candurin® NXT Ruby Red, and 0.3% colloidal silicon dioxide. The process variables studied were surface (X1), chamber temperatures (X2), and laser scanning speed (X3). The range of variable levels was 75-85°C for X1, 50-70°C for X2, and 200-240 mm/s for X3, respectively. The responses studied were hardness, disintegration time, dissolution, physiochemical, and pharmacokinetic characterization. X-ray powder diffraction indicated partial or complete conversion of the crystalline drug into amorphous form in the printlets. Comparative pharmacokinetics between Viread® (generic) and printlets in rats were superimposable. Pharmacokinetic parameters showed statistically insignificant differences between the two formulations in terms of Tmax, Cmax, and AUC of (p > 0.05). Printlets were bioequivalent to Viread® as per FDA bioequivalence criteria. Thus, the SLS printing method showed the fabrication of dose-flexible printlets with quality, and in vivo performance equivalent to commercial tablets.


Asunto(s)
Antivirales , Impresión Tridimensional , Ratas , Animales , Tenofovir/farmacocinética , Composición de Medicamentos , Equivalencia Terapéutica
6.
Mol Pharm ; 19(8): 2937-2949, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35648147

RESUMEN

The focus of this research was to understand the effects of formulation and processing variables on the very-rapidly dissolving printlets of isoniazid (INH) manufactured by the selective laser sintering (SLS) three-dimensional (3D) printing method, and to characterize their physicochemical properties, stability, and pharmacokinetics. Fifteen printlet formulations were manufactured by varying the laser scanning speed (400-500 mm/s, X1), surface temperature (100-110 °C, X2), and croscarmellose sodium (CCS, %, X3), and the responses measured were weight (Y1), hardness (Y2), disintegration time (DT, Y3), and dissolution (Y4). Laser scanning was the most important processing factor affecting the responses. DT was very rapid (≥3 s), and dissolution (>99%) was completed within 3 min. The root-mean-square error in the studied responses was low and analysis of variance (ANOVA) was statistically significant (p < 0.05). X-ray micro-computed tomography (micro-CT) images showed very porous structures with 24.6-34.4% porosity. X-ray powder diffraction and differential scanning calorimetry data indicated partial conversion of the crystalline drug into an amorphous form. The printlets were stable at 40 °C/75% RH with no significant changes in assay and dissolution. Pharmacokinetic profiles of the printlets and compressed tablets were superimposable. In conclusion, the rapidly dissolving printlets of the INH were stable, and oral bioavailability was similar to that of compositionally identical compressed tablets.


Asunto(s)
Excipientes , Isoniazida , Excipientes/química , Impresión Tridimensional , Solubilidad , Comprimidos/química , Microtomografía por Rayos X
7.
Mol Pharm ; 19(7): 2380-2389, 2022 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-35670498

RESUMEN

This study demonstrates the applicability of terahertz time-domain spectroscopy (THz-TDS) in evaluating the solid-state of the drug in selective laser sintering-based 3D printed dosage forms. Selective laser sintering is a powder bed-based 3D printing platform, which has recently demonstrated applicability in manufacturing amorphous solid dispersions (ASDs) through a layer-by-layer fusion process. When formulating ASDs, it is critical to confirm the final solid state of the drug as residual crystallinity can alter the performance of the formulation. Moreover, SLS 3D printing does not involve the mixing of the components during the process, which can lead to partially amorphous systems causing reproducibility and storage stability problems along with possibilities of unwanted polymorphism. In this study, a previously investigated SLS 3D printed ASD was characterized using THz-TDS and compared with traditionally used solid-state characterization techniques, including differential scanning calorimetry (DSC) and powder X-ray diffractometry (pXRD). THz-TDS provided deeper insights into the solid state of the dosage forms and their properties. Moreover, THz-TDS was able to detect residual crystallinity in granules prepared using twin-screw granulation for the 3D printing process, which was undetectable by the DSC and XRD. THz-TDS can prove to be a useful tool in gaining deeper insights into the solid-state properties and further aid in predicting the stability of amorphous solid dispersions.


Asunto(s)
Espectroscopía de Terahertz , Rastreo Diferencial de Calorimetría , Polvos/química , Impresión Tridimensional , Reproducibilidad de los Resultados , Solubilidad , Espectroscopía de Terahertz/métodos
8.
Sensors (Basel) ; 22(19)2022 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-36236629

RESUMEN

Pressure sensing is not a new concept and can be applied by using different transduction mechanisms and manufacturing techniques, including printed electronics approaches. However, very limited efforts have been taken to realise pressure sensors fully using additive manufacturing techniques, especially for personalised guide prosthetics in biomedical applications. In this work, we present a novel, fully printed piezoresistive pressure sensor, which was realised by using Aerosol Jet® Printing (AJP) and Screen Printing. AJ®P was specifically chosen to print silver interconnects on a selective laser sintered (SLS) polyamide board as a customised substrate, while piezoresistive electrodes were manually screen-printed on the top of the interconnects as the sensing layer. The sensor was electromechanically tested, and its response was registered upon the application of given signals, in terms of sensitivity, hysteresis, reproducibility, and time drift. When applying a ramping pressure, the sensor showed two different sensitive regions: (i) a highly sensitive region in the range of 0 to 0.12 MPa with an average sensitivity of 106 Ω/MPa and a low sensitive zone within 0.12 to 1.25 MPa with an average sensitivity of 7.6 Ω/MPa with some indeterminate overlapping regions. Hysteresis was negligible and an electrical resistance deviation of about 14% was observed in time drift experiments. Such performances will satisfy the demands of our application in the biomedical field as a smart prosthetics guide.


Asunto(s)
Nylons , Plata , Aerosoles , Impresión Tridimensional , Reproducibilidad de los Resultados
9.
Sensors (Basel) ; 22(11)2022 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-35684821

RESUMEN

In this study, the circular Gaussian spot emitted by a laser light source is shaped into a rectangular flat-top beam to improve the scanning efficiency of a selective laser sintering scanning system. A CO2 laser with a power of 200 W, wavelength of 10.6 µm, and spot diameter of 9 mm is shaped into a flat-top spot with a length and width of 0.5 × 0.1 mm, and the mapping function and flat-top Lorentzian function are calculated. We utilize ZEMAX to optimize the aspherical cylindrical lens of the shaping system and the cylindrical lens of the focusing system. We then calculate the energy uniformity of the flat-top line-shaped beam at distances from 500 to 535 mm and study the zoom displacement of the focusing lens system. The results indicated that the energy uniformity of the flat-top beam was greater than 80% at the distances considered, and the focusing system must precisely control the displacement of the cylindrical lens in the Y-direction to achieve precise zooming.

10.
AAPS PharmSciTech ; 24(1): 4, 2022 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-36447026

RESUMEN

Three-dimensional (3D)-printed tablets prepared using powder-based printing techniques like selective laser sintering (SLS) typically disintegrate/dissolve and release the drug within a few minutes because of their inherent porous nature and loose structure. The goal of this study was to demonstrate the suitability of SLS 3DP technology for fabricating sustained-release dosages utilizing Kollidon® SR (KSR), a matrix-forming excipient composed of polyvinyl acetate and polyvinylpyrrolidone (8:2). A physical mixture (PM), comprising 10:85:5 (% w/w) of acetaminophen (ACH), KSR, and Candurin®, was sintered using a benchtop SLS 3D printer equipped with a 2.3-W 455-nm blue visible laser. After optimization of the process parameters and formulation composition, robust 3D-printed tablets were obtained as per the computer-aided design (CAD) model. Advanced solid-state characterizations by powder X-ray diffraction (PXRD) and wide-angle X-ray scattering (WAXS) confirmed that ACH remained in its native crystalline state after sintering. In addition, X-ray micro-computed tomography (micro-CT) studies revealed that the tablets contain a total porosity of 57.7% with an average pore diameter of 24.8 µm. Moreover, SEM images exhibited a morphological representation of the ACH sintered tablets' exterior surface. Furthermore, the KSR matrix 3D-printed tablets showed a sustained-release profile, releasing roughly 90% of the ACH over 12 h as opposed to a burst release from the free drug and PM. Overall, our work shows for the first time that KSR can be used as a suitable polymer matrix to create sustained-release dosage forms utilizing the digitally controllable SLS 3DP technology, showcasing an alternative technique and pharmaceutical excipient.


Asunto(s)
Excipientes , Impresión Tridimensional , Acetaminofén , Preparaciones de Acción Retardada , Povidona , Polvos , Microtomografía por Rayos X
11.
J Oral Implantol ; 48(4): 263-268, 2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-34091668

RESUMEN

This study was designed to evaluate the accuracy of a novel computer-designed and selectively laser sintered surgical guide for flapless dental implant placement in the edentulous jaw. Fifty dental implants were placed in 11 patients with at least 1 totally edentulous jaw. Initially, cone-beam computed tomography (CBCT) was performed in each patient to define the virtual position of the dental implants based on the assessment of bone availability and the proposed dental prosthesis. After virtual planning, 3D surgical guides were printed using selective laser sintering. CBCT was repeated after the surgery, and the pre- and postoperative images were overlapped in computer-assisted design software to compare the planned and actual positions of the dental implants using a 1-sample t test. The mean ± angular standard deviation between the long axes of the planned and final dental implant positions was 4.58° ± 2.85°; the linear deviation in the coronal position was 0.87 ± 0.49 mm and in the apical region of the dental implants was 1.37 ± 0.69 mm. These differences were statistically significant (P < .001). The proposed modifications reduced the deviations, resulting in an improvement in the technique. We were able to place implants and temporary prostheses using the present protocol, taking into account the differences between the planned and final positions of the dental implants.


Asunto(s)
Implantes Dentales , Arcada Edéntula , Cirugía Asistida por Computador , Diseño Asistido por Computadora , Computadores , Tomografía Computarizada de Haz Cónico/métodos , Implantación Dental Endoósea/métodos , Humanos , Imagenología Tridimensional/métodos , Arcada Edéntula/diagnóstico por imagen , Arcada Edéntula/cirugía , Rayos Láser , Planificación de Atención al Paciente , Cirugía Asistida por Computador/métodos
12.
Int J Comput Dent ; 25(1): 57-70, 2022 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-35322653

RESUMEN

AIM: The aim of the present study was to review the current development status of additive manufacturing (AM) technology for fabricating frameworks for removable partial dentures (RPDs) considering fit accuracy, surface condition, and mechanical strength. METHODS: A search of the databases of MEDLINE, Cochrane Library, and Science Direct was conducted using definite keywords ("removable partial denture" or "framework" or "dental prosthesis design") and ("additive manufacturing technology" or "rapid prototyping" or "3D-printing"). RESULT: A total of 23 articles were selected according to certain inclusion criteria. The direct AM techniques were applied to manufacture metal RPD frameworks consisting of selective laser melting (SLM), selective laser sintering (SLS), and metal binder jetting (MBJ). The SLM technique showed a good surface and mechanical strength, but low accuracy. The SLS technique showed higher accuracy than indirect AM, but further studies are required. The MBJ technique showed lower accuracy and a rougher surface than the conventional method. CONCLUSION: AM techniques can produce RPD frameworks within the acceptable range for clinical practice; however, more clinical studies are needed.


Asunto(s)
Dentadura Parcial Removible , Humanos , Rayos Láser , Impresión Tridimensional
13.
Int J Comput Dent ; 25(2): 151-159, 2022 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-35060369

RESUMEN

AIM: Milling-based, subtractive fabrication of digital complete dentures represents the computer-engineered manufacturing method of choice. However, efficient additive manufacturing technologies might also prove beneficial for the indication. The aim of the present study was to evaluate the accuracy of surface adaptation of complete denture bases fabricated using subtractive, additive, and conventional manufacturing techniques. MATERIALS AND METHODS: A standardized edentulous maxillary model was digitally designed and milled. Twelve duplicated plaster casts were scanned and virtual denture bases designed accordingly. Physical complete denture bases (n = 12 per technique) were manufactured applying different digital and conventional fabrication methods: 1) CNC milling (MIL); 2) material jetting (MJ); 3) selective laser sintering (SLS); 4) digital light processing (DLP); and 5) conventional injection molding (INJ). The INJ group served as control. The intaglio surfaces of the denture bases were digitized and superposed with the surface data of the casts using a best-fit algorithm. Accuracy of surface adaptation was assessed by examining deviations. Statistical analysis was conducted using SPSS (P < 0.05). RESULTS: The milling of denture bases led to significantly better surface adaptation compared with all the other technologies (P < 0.001). The other fabrication methods in the study, including conventional manufacturing, revealed no considerable overall differences. CONCLUSIONS: As regards the accuracy of surface adaptation, all the investigated technologies adequately produced complete denture bases, with milled denture bases presenting the most superior results.


Asunto(s)
Bases para Dentadura , Diseño de Dentadura , Diseño Asistido por Computadora , Dentadura Completa , Humanos , Rayos Láser
14.
Eur J Prosthodont Restor Dent ; 30(2): 96-106, 2022 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-34029015

RESUMEN

Rehabilitation of a patient after hemi-mandibulectomy without reconstruction represents a prosthodontic challenge. Indeed, mandibular deviation and decreased occlusal contacts are a common presentation post-surgery. This paper reports on a patient who presented with these challenges and where chronic osteoradionecrosis has resulted in significant mandibular deviation. A maxillary cobalt chrome mandibular deviation device, designed with palatal bite plane and constructed using 3D printing methods, resulted in a successful outcome. The authors aim to show how restorative management of similar patients can be successful using a modern approach.


Asunto(s)
Neoplasias Mandibulares , Osteorradionecrosis , Humanos , Mandíbula/cirugía , Neoplasias Mandibulares/cirugía , Osteotomía Mandibular , Osteorradionecrosis/cirugía
15.
Mol Pharm ; 18(10): 3894-3908, 2021 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-34529431

RESUMEN

This research study utilized a light-sensitive drug, nifedipine (NFD), to understand the impact of processing parameters and formulation composition on drug degradation, crystallinity, and quality attributes (dimensions, hardness, disintegration time) of selective laser sintering (SLS)-based three-dimensional (3D)-printed dosage forms. Visible lasers with a wavelength around 455 nm are one of the laser sources used for selective laser sintering (SLS) processes, and some drugs such as nifedipine tend to absorb radiation at varying intensities around this wavelength. This phenomenon may lead to chemical degradation and solid-state transformation, which was assessed for nifedipine in formulations with varying amounts of vinyl pyrrolidone-vinyl acetate copolymer (Kollidon VA 64) and potassium aluminum silicate-based pearlescent pigment (Candurin) processed under different SLS conditions in the presented work. After preliminary screening, Candurin, surface temperature (ST), and laser speed (LS) were identified as the significant independent variables. Further, using the identified independent variables, a 17-run, randomized, Box-Behnken design was developed to understand the correlation trends and quantify the impact on degradation (%), crystallinity, and quality attributes (dimensions, hardness, disintegration time) employing qualitative and quantitative analytical tools. The design of experiments (DoEs) and statistical analysis observed that LS and Candurin (wt %) had a strong negative correlation on drug degradation, hardness, and weight, whereas ST had a strong positive correlation with drug degradation, amorphous conversion, and hardness of the 3D-printed dosage form. From this study, it can be concluded that formulation and processing parameters have a critical impact on stability and performance; hence, these parameters should be evaluated and optimized before exposing light-sensitive drugs to the SLS processes.


Asunto(s)
Composición de Medicamentos/métodos , Nifedipino/química , Impresión Tridimensional , Rastreo Diferencial de Calorimetría , Cromatografía Líquida de Alta Presión , Estabilidad de Medicamentos , Dureza , Rayos Láser , Nifedipino/análisis , Nifedipino/síntesis química , Nifedipino/efectos de la radiación , Fotólisis , Impresión Tridimensional/normas , Comprimidos
16.
Drug Dev Ind Pharm ; 46(6): 869-877, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32364418

RESUMEN

Food and Drug Administration (FDA) has approved a drug product (Spritam®) and many medical devices manufactured by three-dimensional printing (3DP) processes for human use. There is immense potential to print personalized medicines using 3DP. Many 3DP methods have been reported in the literature for pharmaceutical applications. However, selective laser sintering (SLS) printing has remained least explored for pharmaceutical applications. There are many advantages and challenges in adopting a SLS method for fabrication of personalized medicines. Solvent-free nature, availability of FDA approved thermoplastic polymer/excipients (currently used in hot melt-extrusion process), minimal/no post-processing step, etc. are some of the advantages of the SLS printing process. Major challenges of the technology are requirement of at least one thermoplastic component in the formulation and thermal stability of drug and excipients. This review provides an overview of the SLS printing method, excipient requirements, process monitoring, quality defects, regulatory aspects, and potential pharmaceutical applications.


Asunto(s)
Preparaciones Farmacéuticas , Excipientes/química , Humanos , Rayos Láser , Impresión Tridimensional , Tecnología Farmacéutica
17.
AAPS PharmSciTech ; 21(6): 232, 2020 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-32794080

RESUMEN

The aims of the current study were to develop and evaluate clindamycin palmitate hydrochloride (CPH) 3D-printed tablets (printlets) manufactured by selective laser sintering (SLS). Optimization of the formulation was performed by studying the effect of formulation and process factors on critical quality attributes of the printlets. The independent factors studied were laser scanning speed, microcrystalline cellulose (MCC), and lactose monohydrate (LMH) concentration. The responses measured were printlets weight, hardness, disintegration time (DT), and dissolution in 30 min. The printlets were characterized for content uniformity, chemical interactions, crystallinity, drug distribution, morphology, and porosity. The laser scanning speed showed statistically significant effects on all the studied dependent responses (p < 0.05). MCC showed statistically significant effects on hardness, DT, and dissolution (p < 0.05), while LMH showed statistically significant effect on hardness and dissolution (p < 0.05). The model was validated by an independent formulation, and empirical values were in close agreement with model-predicted values. X-ray powder diffraction and differential scanning calorimetry data suggested a decrease in crystallinity of the LMH in the printlets. X-ray micro-CT scanning showed porous microstructure of the printlets with a porosity 24.4% and 31.1% for the printlets printed at 200 and 300 mm/s laser speed, respectively. In summary, the SLS method provides an opportunity to fabricate customized dosage forms as per patients' need.


Asunto(s)
Clindamicina/análogos & derivados , Rayos Láser , Impresión Tridimensional , Antibacterianos/análisis , Antibacterianos/síntesis química , Rastreo Diferencial de Calorimetría/métodos , Clindamicina/análisis , Clindamicina/síntesis química , Dureza , Humanos , Porosidad , Propiedades de Superficie , Comprimidos/química , Difracción de Rayos X/métodos
18.
Sensors (Basel) ; 19(7)2019 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-30974757

RESUMEN

This paper showcases a substantial review on some of the significant work done on 3D printing of sensors for biomedical applications. The importance of 3D printing techniques has bloomed in the sensing world due to their essential advantages of quick fabrication, easy accessibility, processing of varied materials and sustainability. Along with the introduction of the necessity and influence of 3D printing techniques for the fabrication of sensors for different healthcare applications, the paper explains the individual methodologies used to develop sensing prototypes. Six different 3D printing techniques have been explained in the manuscript, followed by drawing a comparison between them in terms of their advantages, disadvantages, materials being processed, resolution, repeatability, accuracy and applications. Finally, a conclusion of the paper is provided with some of the challenges of the current 3D printing techniques about the developed sensing prototypes, their corresponding remedial solutions and a market survey determining the expenditure on 3D printing for biomedical sensing prototypes.


Asunto(s)
Investigación Biomédica/tendencias , Técnicas Biosensibles/tendencias , Impresión Tridimensional/tendencias , Humanos
19.
Int J Comput Dent ; 22(1): 55-67, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30848255

RESUMEN

OBJECTIVES: To review the current metal-based additive manufacturing (AM) technologies, namely powder bed fusion (PBF) technologies, and their current prosthodontic applications. The PBF technologies reviewed are selective laser sintering (SLS), selective laser melting (SLM), and electron beam melting (EBM). MATERIALS AND METHODS: The literature on metal AM technologies was considered, and the AM procedures and their current applications in prosthodontics were collated and described. Published articles about AM metal in dental care were searched (MEDLINE, EMBASE, EBSCO, and Web of Science). All studies related to the description, analysis, and evaluation of prosthodontic applications using metal AM technologies. RESULTS AND CONCLUSIONS: AM technologies are reliable for many applications in dentistry, including metal frameworks for removable partial dentures (RPDs), overdentures, tooth- and implant-supported fixed dental prostheses (FDPs), and metal frameworks for splinting implant impression abutments. However, further studies are needed in future to evaluate the accuracy, reproducibility, and clinical outcome throughout function of AM technologies.


Asunto(s)
Dentadura Parcial Removible , Prostodoncia , Humanos , Metales , Prótesis e Implantes , Reproducibilidad de los Resultados
20.
J Prosthodont ; 28(4): 428-435, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29136309

RESUMEN

PURPOSE: To compare the shrinkage of denture bases fabricated by three methods: CAD/CAM, compression molding, and injection molding. The effect of arch form and palate depth was also tested. MATERIALS AND METHODS: Nine titanium casts, representing combinations of tapered, ovoid, and square arch forms and shallow, medium, and deep palate depths, were fabricated using electron beam melting (EBM) technology. For each base fabrication method, three poly(vinyl siloxane) impressions were made from each cast, 27 dentures for each method. Compression-molded dentures were fabricated using Lucitone 199 poly methyl methacrylate (PMMA), and injection molded dentures with Ivobase's Hybrid Pink PMMA. For CAD/CAM, denture bases were designed and milled by Avadent using their Light PMMA. To quantify the space between the denture and the master cast, silicone duplicating material was placed in the intaglio of the dentures, the titanium master cast was seated under pressure, and the silicone was then trimmed and recovered. Three silicone measurements per denture were recorded, for a total of 243 measurements. Each silicone measurement was weighed and adjusted to the surface area of the respective arch, giving an average and standard deviation for each denture. RESULTS: Comparison of manufacturing methods showed a statistically significant difference (p = 0.0001). Using a ratio of the means, compression molding had on average 41% to 47% more space than injection molding and CAD/CAM. Comparison of arch/palate forms showed a statistically significant difference (p = 0.023), with shallow palate forms having more space with compression molding. The ovoid shallow form showed CAD/CAM and compression molding had more space than injection molding. CONCLUSION: Overall, injection molding and CAD/CAM fabrication methods produced equally well-fitting dentures, with both having a better fit than compression molding. Shallow palates appear to be more affected by shrinkage than medium or deep palates. Shallow ovoid arch forms appear to benefit from the use of injection molding compared to CAD/CAM and compression molding.


Asunto(s)
Bases para Dentadura , Diseño de Dentadura , Diseño Asistido por Computadora , Polimetil Metacrilato
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA