Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Nano Lett ; 19(7): 4594-4600, 2019 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-31251073

RESUMEN

When graphene is placed on a crystalline surface, the periodic structures within the layers superimpose and moiré superlattices form. Small lattice rotations between the two materials in contact strongly modify the moiré lattice parameter, upon which many electronic, vibrational, and chemical properties depend. While precise adjustment of the relative orientation in the degree- and sub-degree-range can be achieved via careful deterministic transfer of graphene, we report on the spontaneous reorientation of graphene on a metallic substrate, Ir(111). We find that selecting a substrate temperature between 1530 and 1000 K during the growth of graphene leads to distinct relative rotational angles of 0°, ± 0.6°, ±1.1°, and ±1.7°. When modeling the moiré superlattices as two-dimensional coincidence networks, we can ascribe the observed rotations to favorable low-strain graphene structures. The dissimilar thermal expansion of the substrate and graphene is regarded as an effective compressive biaxial pressure that is more easily accommodated in graphene by small rotations rather than by compression.

2.
Pain Pract ; 18(4): 539-543, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28862789

RESUMEN

Chronic neuropathic pain is often refractory to conventional medical treatments and leads to significant disability and socio-economic burden. Dorsal root ganglion (DRG) stimulation has recently emerged as a treatment for persistent neuropathic pain, but creating a strain relief loop at the S1 level has thus far been a challenging technical component of DRG lead placement. We describe a refined technique for strain relief loop formation at the S1 level using a transforaminal approach that we employed in a 45-year-old patient with intractable foot pain. We successfully placed a strain relief loop in the sacral space in a predictable and easily reproducible manner using a transforaminal anchorless approach. The patient experienced a decrease in visual analog pain score (85%), and improvement in function during the trial period, and proceeded with permanent implantation. The described sacral transforaminal strain relief loop formation technique appears to be a more reliable and predictable technique of DRG lead placement in the sacrum than those previously documented.


Asunto(s)
Ganglios Espinales/cirugía , Neuralgia/terapia , Estimulación de la Médula Espinal/métodos , Pie , Ganglios Espinales/fisiología , Humanos , Masculino , Persona de Mediana Edad , Dolor Intratable/terapia
3.
Nano Lett ; 15(8): 5098-104, 2015 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-26171667

RESUMEN

We measure uniaxial strain fields in the vicinity of edges and wrinkles in graphene prepared by chemical vapor deposition (CVD), by combining microscopy techniques and local vibrational characterization. These strain fields have magnitudes of several tenths of a percent and extend across micrometer distances. The nonlinear shear-lag model remarkably captures these strain fields in terms of the graphene-substrate interaction and provides a complete understanding of strain-relieving wrinkles in graphene for any level of graphene-substrate coherency.

4.
Ann Biomed Eng ; 45(3): 681-694, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27562143

RESUMEN

The goal of this study was to develop stable intraspinal microstimulation (ISMS) implants for use in humans to restore standing and walking after spinal cord injury. ISMS electrically activates locomotor networks within the lumbar region of the spinal cord. In animals, ISMS produced better functional outcomes than those obtained by other interventions, and recent efforts have focused on translating this approach to humans. This study used domestic pigs to: (1) quantify the movements and length changes of the implant region of the spinal cord during spine flexion and extension movements; and (2) measure the forces leading to the dislodgement of the ISMS electrodes. The displacement of the spinal cord implant region was 5.66 ± 0.57 mm relative to the implant fixation point on the spine. The overall length change of the spinal cord implant region was 5.64 ± 0.59 mm. The electrode dislodgment forces were 60.9 ± 35.5 mN. Based on these results, six different coil types were fabricated and their strain relief capacity assessed. When interposed between the electrodes and the stimulator, five coil types successfully prevented the dislodgement of the electrodes. The results of this study will guide the design of mechanically stable ISMS implants for ultimate human use.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Implantes Experimentales , Locomoción , Traumatismos de la Médula Espinal/fisiopatología , Traumatismos de la Médula Espinal/terapia , Animales , Terapia por Estimulación Eléctrica/métodos , Humanos , Porcinos
5.
ACS Appl Mater Interfaces ; 9(10): 9079-9088, 2017 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-28252927

RESUMEN

We characterize wrinkling on the surfaces of prestrained polystyrene sheets coated with thin polytetrafluoroethylene skins using a combination of mechanical strain measurements and 3D finite element simulations. The simulations show that wrinkle wavelength increases with skin thickness, in agreement with a well-known continuum model and recent experiments. The wrinkle amplitudes also increase with strain. Nanoinclusions, such as holes and patterned lines, influence wrinkle patterns over limited distances, and these distances are shown to scale with the wrinkle wavelengths. Good agreement between experimental and simulated influence distances is observed. The inclusions provide strain relief, and they behave as if they are attracting adjacent material when the sheets are under strain. The wrinkles have stiffnesses in much the same way as do polymers (but at different length scales), a property that is quantified for polymers using persistence lengths. We show that the concept of persistence length can be useful in characterizing the wrinkle properties that we have observed. However, the calculated persistence lengths do not vary systematically with thickness and strain, as interactions between neighboring wrinkles produce confinement that is analogous to the kinetic confinement of polymers.

6.
Front Neurol ; 4: 124, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24062716

RESUMEN

While the signal quality of recording neural electrodes is observed to degrade over time, the degradation mechanisms are complex and less easily observable. Recording microelectrodes failures are attributed to different biological factors such as tissue encapsulation, immune response, and disruption of blood-brain barrier (BBB) and non-biological factors such as strain due to micromotion, insulation delamination, corrosion, and surface roughness on the recording site (1-4). Strain due to brain micromotion is considered to be one of the important abiotic factors contributing to the failure of the neural implants. To reduce the forces exerted by the electrode on the brain, a high compliance 2D serpentine shaped electrode cable was designed, simulated, and measured using polyimide as the substrate material. Serpentine electrode cables were fabricated using MEMS microfabrication techniques, and the prototypes were subjected to load tests to experimentally measure the compliance. The compliance of the serpentine cable was numerically modeled and quantitatively measured to be up to 10 times higher than the compliance of a straight cable of same dimensions and material.

7.
Nanoscale Res Lett ; 4(12): 1458-62, 2009 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-20652143

RESUMEN

We report structural analysis of completely relaxed GaSb epitaxial layers deposited monolithically on GaAs substrates using interfacial misfit (IMF) array growth mode. Unlike the traditional tetragonal distortion approach, strain due to the lattice mismatch is spontaneously relieved at the heterointerface in this growth. The complete and instantaneous strain relief at the GaSb/GaAs interface is achieved by the formation of a two-dimensional Lomer dislocation network comprising of pure-edge (90°) dislocations along both [110] and [1-10]. In the present analysis, structural properties of GaSb deposited using both IMF and non-IMF growths are compared. Moiré fringe patterns along with X-ray diffraction measure the long-range uniformity and strain relaxation of the IMF samples. The proof for the existence of the IMF array and low threading dislocation density is provided with the help of transmission electron micrographs for the GaSb epitaxial layer. Our results indicate that the IMF-grown GaSb is completely (98.5%) relaxed with very low density of threading dislocations (105 cm-2), while GaSb deposited using non-IMF growth is compressively strained and has a higher average density of threading dislocations (>109 cm-2).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA