Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Lasers Med Sci ; 32(3): 573-581, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28120248

RESUMEN

This study was conducted in order to compare clinical and histopathological outcomes for excisional biopsies when using pulsed CO2 laser versus Er:YAG laser. Patients (n = 32) with a fibrous hyperplasia in the buccal mucosa were randomly allocated to the CO2 (140 Hz, 400 µs, 33 mJ) or the Er:YAG laser (35 Hz, 297 µs, 200 mJ) group. The duration of excision, intraoperative bleeding and methods to stop the bleeding, postoperative pain (VAS; ranging 0-100), the use of analgesics, and the width of the thermal damage zone (µm) were recorded and compared between the two groups. The median duration of the intervention was 209 s, and there was no significant difference between the two methods. Intraoperative bleeding occurred in 100% of the excisions with Er:YAG and 56% with CO2 laser (p = 0.007). The median thermal damage zone was 74.9 µm for CO2 and 34.0 µm for Er:YAG laser (p < 0.0001). The median VAS score on the evening after surgery was 5 for the CO2 laser and 3 for the Er:YAG group. To excise oral soft tissue lesions, CO2 and Er:YAG lasers are both valuable tools with a short time of intervention and postoperative low pain. More bleeding occurs with the Er:YAG than CO2 laser, but the lower thermal effect of Er:YAG laser seems advantageous for histopathological evaluation.


Asunto(s)
Láseres de Gas/uso terapéutico , Láseres de Estado Sólido/uso terapéutico , Mucosa Bucal/patología , Mucosa Bucal/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Analgésicos/farmacología , Biopsia , Pérdida de Sangre Quirúrgica , Demografía , Electrocoagulación , Femenino , Humanos , Hiperplasia , Láseres de Gas/efectos adversos , Láseres de Estado Sólido/efectos adversos , Masculino , Persona de Mediana Edad , Mucosa Bucal/efectos de los fármacos , Dolor Postoperatorio/etiología , Cicatrización de Heridas/efectos de los fármacos , Adulto Joven
2.
Lasers Surg Med ; 46(5): 396-404, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24700467

RESUMEN

BACKGROUND: In experimental animal studies, pulsing the CO2 laser beam has been shown to reduce the thermal damage zone of excised oral mucosal tissue. However, there is still controversy over whether this is borne out under clinical conditions. OBJECTIVE: To compare the outcome following excisional biopsies of fibrous hyperplasias using a pulsed (cf) versus a continuous wave (cw) CO2 laser mode regarding the thermal damage zone, duration of surgeries, intra- and postoperative complications, postoperative pain sensation, scarring and/or relapse during the initial 6 months. MATERIALS AND METHODS: One hundred Swiss-resident patients with a fibrous hyperplasia in their buccal mucosa were randomly assigned to the cw mode (5 W) or the cf mode (140 Hz, 400 microseconds, 33 mJ, 4.62 W) group. All excisions were performed by one single oral surgeon. Postoperative pain (2 weeks) was recorded by visual analogue scale (VAS; ranging from 0 to 100). Intake of analgesics and postoperative complications were recorded in a standardized study form. The maximum width of the collateral thermal damage zone was measured (µm) in excision specimens by one pathologist. Intraoral photographs at 6-month follow-up examinations were evaluated regarding scarring (yes/no). RESULTS: Median duration of the excision was 65 seconds in the cw and 81 seconds in the cf group (P = 0.13). Intraoperative bleeding occurred in 16.3% of the patients in the cw and 17.7% of the cf group. The median value of the thermal damage zone was 161(±228) µm in the cw and 152(± 105) µm in the cf group (P = 0.68). The reported postoperative complications included swelling in 19% and minor bleeding in 6% without significant differences between the two laser modes. When comparing each day separately or the combined mean VAS scores of both groups between Days 1-3, 1-7, and 1-15, there were no significant differences. However, more patients of the cw group (25%) took analgesics than patients of the cf group (9.8%) resulting in a borderline significance (P = 0.04). Scarring at the excision site was found in 50.6% of 77 patients after 6 months, and more scars were identified in cases treated with the cf mode (P = 0.03). CONCLUSIONS: Excision of fibrous hyperplasias performed with a CO2 laser demonstrated a good clinical outcome and long-term predictability with a low risk of recurrence regardless of the laser mode (cf or cw) used. Scarring after 6 months was only seen in 50.6% of the cases and was slightly more frequent in the cf mode group. Based on the findings of the present study, a safety border of 1 mm appears sufficient for both laser modes especially when performing a biopsy of a suspicious soft tissue lesion to ensure a proper histopathological examination.


Asunto(s)
Láseres de Gas/uso terapéutico , Mucosa Bucal/patología , Mucosa Bucal/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Biopsia , Cicatriz/etiología , Femenino , Fibrosis/patología , Fibrosis/cirugía , Estudios de Seguimiento , Humanos , Hiperplasia/patología , Hiperplasia/cirugía , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Dolor Postoperatorio , Complicaciones Posoperatorias , Resultado del Tratamiento
3.
Materials (Basel) ; 14(18)2021 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-34576681

RESUMEN

The lungs are a common site of metastases from malignant tumors. Their removal with a minimal but safe tissue margin is essential for the long-term survival of patients. The aim of this study was to evaluate the usefulness of a 1940 nm thulium-doped fiber laser (TDFL) and a 1470 nm diode laser (DL) in a pig model of lung surgery that involved the incision and excision of lung tissue. Histopathological analysis was performed on days 0 and 7 after surgery. Neither TDFL nor DL caused significant perioperative or postoperative bleeding. Histological analysis revealed the presence of carbonized necrotic tissue, mixed fibrin-cellular exudate in the superficial zone of thermal damage and bands of deeper thermal changes. The mean total width of thermal damage on day 0 was 499.46 ± 61.44 and 937.39 ± 109.65 µm for TDFL and DL, respectively. On day 7, cell activation and repair processes were visible. The total width of thermal damage was 2615.74 ± 487.17 µm for TDFL vs. 6500.34 ±1118.02 µm for DL. The superficial zone of thermal damage was narrower for TDFL on both days 0 and 7. The results confirm the effectiveness of both types of laser in cutting and providing hemostasis in the lungs. TDFL caused less thermal damage to the lung parenchyma than DL.

4.
Materials (Basel) ; 14(8)2021 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-33923581

RESUMEN

BACKGROUND: The aim of this study was to evaluate the usefulness of a thulium-doped fiber laser and a diode laser in zero ischemia kidney surgery, by carrying out a comparative study in a pig model. MATERIAL AND METHODS: Research was carried out on 12 pigs weighing 30 kg each. A thulium-doped fiber laser (TDFL) and a diode laser (DL) operating at wavelengths of 1940 and 1470 nm, respectively, were used. The cut sites were assessed both macroscopically and microscopically. The zone of thermal damage visible in the histopathological preparations was divided into superficial and total areas. RESULTS: During partial nephrectomy, moderate to minimal bleeding was observed, which did not require additional hemostatic measures. All animals survived the procedure. On day 0, the total thermal damage depth was 837.8 µm for the TDFL and 1175.0 µm for the DL. On day 7, the depths were 1556.2 and 2301.7 µm, respectively. On day 14, the overall thermal damage depth for the DL was the greatest (6800 µm). The width of the superficial zone was significantly reduced on days 7 and 14 after TDFL application. CONCLUSION: Both lasers are suitable for partial wedge nephrectomy without ischemia in pigs. The TDFL produced similar or better hemostasis than the DL, with a smaller zone of thermal damage and, therefore, seems more suitable for application in human medicine.

5.
Materials (Basel) ; 13(5)2020 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-32151086

RESUMEN

Partial and total splenectomies are associated with a high risk of substantial blood loss. Lasers operating at wavelengths strongly absorbed by water have the potential to improve hemostasis and cut while providing a narrow zone of thermal damage. The aim of this study is to compare a thulium-doped fiber laser (TDFL) emitting a wavelength of 1940 nm and a diode laser (DL) operating at 1470 nm for spleen surgery in a pig model. A partial splenectomy and spleen incisions were made in 12 animals using the two laser devices. The hemostasis was evaluated visually during surgeries. Post-mortem and histopathological evaluations were done on days 0, 7, and 14 following surgery. Neither TDFL nor DL caused bleeding on day 0 or delayed bleeding. On day 14, pale streaks at the site of incision were slightly wider after cutting with DL than with TDFL. Histological analysis revealed a carbonized zone with exudation and a deeper zone of thermal tissue damage on day 0. The width of the thermal changes was 655.26 ± 107.70 µm for TDFL and 1413.37 ± 111.85 µm for DL. On day 7, a proliferation of fibroblasts and splenocytes was visible, as well as a formation of multinucleated giant cells adjacent to the residues of carbonization. The zone of thermal damage was broader for DL (1157.5 ± 262.77 µm) than for TDFL (682.22 ± 116.58 µm). On day 14, cutting sites were filled with connective and granulation tissues with the residues of carbonization. The zone of thermal damage was narrower for TDFL (761.65 ± 34.3 µm) than for DL (1609.82 ± 202.22 µm). Thus, both lasers are efficient in spleen surgery, providing good hemostasis. However, TDFL produces a narrower zone of thermal damage, which suggests its better efficiency for spleen surgery, especially when performing more precise procedures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA