Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 925
Filtrar
Más filtros

Intervalo de año de publicación
1.
Curr Opin Ophthalmol ; 35(2): 138-146, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38059758

RESUMEN

PURPOSE OF REVIEW: Posterior chamber phakic intraocular lenses (pIOLs) are increasing in popularity as a viable alternative to laser refractive surgery. The purpose of this review is to evaluate the recent updates to pIOLs and to assess the advancements and safety of the procedure. RECENT FINDINGS: Accurate lens sizing is the key determinant to suitable vault prediction, advancements to sizing formulae including the use of very high frequency (VHF) digital ultrasound and the application of artificial intelligence and machine learning has led to improved vault prediction and safety. The introduction of the central aquaport has been shown to reduce the formation of cataract and is now adopted in most myopic pIOLs. Recently published studies have demonstrated that pIOLs have an excellent safety profile with no increased risk of retinal detachment or endothelial cell loss. Advancements have led to the introduction of extended depth of focus pIOLs for the correction of presbyopia, further research is required to evaluate the efficacy of new lens designs. SUMMARY: pIOL surgery is experiencing traction with improved lens design and increased lenses choices such as larger optical zone and presbyopic options. Accuracy of implantable collamer lens sizing is paramount to the safety and clinical outcomes, greater predictability is likely to encourage more posterior chamber pIOL users due to fewer sizing related complications.


Asunto(s)
Cristalino , Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Humanos , Lentes Intraoculares Fáquicas/efectos adversos , Inteligencia Artificial , Implantación de Lentes Intraoculares/efectos adversos , Miopía/cirugía
2.
Curr Opin Ophthalmol ; 35(4): 284-291, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38700946

RESUMEN

PURPOSE OF REVIEW: Higher degrees of myopia are currently being treated with refractive surgery. However, there is limited characterization and outcomes data for this cohort. This article aims to review the literature on highly myopic patients who had refractive surgery and present a retrospective analysis of 149 patients (270 eyes) with high to extreme myopia (≤-5.0D SE) who underwent refractive surgery [laser-assisted subepithelial keratomileusis (LASIK), photorefractive keratectomy (PRK), or implantable collamer lense (ICL)] at a single practice. RECENT FINDINGS: There is substantial literature on the efficacy of LASIK, PRK, and phakic intraocular lenses for refractive error correction, but a dearth of studies on patients with high to extreme myopia undergoing different types of refractive surgery. Our study reveals that this cohort of patients has excellent outcomes with minimal complications. SUMMARY: Our study reveals that the average preoperative myopia was highest in ICL patients (-10.03D), followed by PRK (-7.21D), and LASIK (-7.04D) patients. Not surprisingly, eyes with high myopia and thin corneas were offered and elected ICLs for their procedure. Highly myopic patients achieved outcomes consistent with data reported in the literature- average postoperative uncorrected visual acuity was 20/20 for LASIK and ICL eyes and 20/25 for PRK eyes.


Asunto(s)
Queratectomía Fotorrefractiva , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Resultado del Tratamiento , Queratectomía Fotorrefractiva/métodos , Implantación de Lentes Intraoculares/métodos , Queratomileusis por Láser In Situ/métodos , Refracción Ocular/fisiología , Estudios Retrospectivos , Miopía Degenerativa/cirugía , Miopía Degenerativa/fisiopatología , Miopía/cirugía , Miopía/fisiopatología , Lentes Intraoculares Fáquicas , Adulto , Masculino , Femenino
3.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 323-330, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37490104

RESUMEN

PURPOSE: We aimed to explore the effects of the ciliary sulcus angle (CSA) on accurate prediction of the vault after phakic implantable collamer lens (EVO ICL Model V4c) using the KS formula. METHODS: Patients were classified according to the size of CSA: group A, narrow angle (CSA < 30°); group B, normal angle (CSA = 30-90°); and group C, wide angle (CSA > 90°). Further, differences between the actual vault dimensions at 3 months postoperatively and the preoperatively predicted vault dimensions in the three groups were analyzed. RESULTS: This study included 223 eyes of 223 individuals. In groups A-C, the difference in the preoperative vault dimensions of the three groups predicted with the KS formula was not statistically significant (P = 0.056). The actual vault dimensions at 3 months postoperatively were significantly different between the three groups (P < 0.001). Moreover, the difference between the actual and predicted vaults by the KS formula was statistically significant (P < 0.001). In the 3 months, after surgery, the percentages of patients with a low vault (< 250 µm) were 0%, 3%, and 29% in groups A, B, and C, respectively. Further, the percentages of patients with an ideal vault (250-750 µm) in the postoperative period were 66%, 84%, and 71% in groups A, B, and C, respectively. Finally, the percentages of patients with a high vault (> 750 µm) in the postoperative period were 34%, 13%, and 0% in groups A, B, and C, respectively. Notably, the distribution of the vault among the three groups was statistically significant (P < 0.001). CONCLUSION: The size of CSA significantly affects the predictiveness of the vault by the KS formula, with the most pronounced effect on the angles < 30° and > 90°. Therefore, CSA should be considered when selecting the lens size using the KS formula preoperatively. CLINICAL TRIAL REGISTRATION NUMBER: ChiCTR2200065501.


Asunto(s)
Cristalino , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares/métodos , Agudeza Visual , Ojo , Estudios Retrospectivos
4.
Graefes Arch Clin Exp Ophthalmol ; 262(5): 1553-1565, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38150030

RESUMEN

BACKGROUND: Phakic lenses (PIOLs, the most common and only disclosed type being the implantable collamer lens, ICL) are used in patients with large or excessive ametropia in cases where laser refractive surgery is contraindicated. The purpose of this study was to present a strategy based on anterior segment OCT data for calculating the refraction correction (REF) and the change in lateral magnification (ΔM) with ICL implantation. METHODS: Based on a dataset (N = 3659) containing Casia 2 measurements, we developed a vergence-based calculation scheme to derive the REF and gain or loss in ΔM on implantation of a PIOL having power PIOLP. The calculation concept is based on either a thick or thin lens model for the cornea and the PIOL. In a Monte-Carlo simulation considering, all PIOL steps listed in the US patent 5,913,898, nonlinear regression models for REF and ΔM were defined for each PIOL datapoint. RESULTS: The calculation shows that simplifying the PIOL to a thin lens could cause some inaccuracies in REF (up to ½ dpt) and ΔM for PIOLs with high positive power. The full range of listed ICL powers (- 17 to 17 dpt) could correct REF in a range from - 17 to 12 dpt with a change in ΔM from 17 to - 25%. The linear regression considering anterior segment biometric data and the PIOLP was not capable of properly characterizing REF and ΔM, whereas the nonlinear model with a quadratic term for the PIOLP showed a good performance for both REF and ΔM prediction. CONCLUSION: Where PIOL design data are available, the calculation concept should consider the PIOL as thick lens model. For daily use, a nonlinear regression model can properly predict REF and ΔM for the entire range of PIOL steps if a vergence calculation is unavailable.


Asunto(s)
Cristalino , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares , Tomografía de Coherencia Óptica , Cristalino/cirugía , Refracción Ocular
5.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2329-2336, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38376562

RESUMEN

PURPOSE: This study aims to assess the accuracy of three parameters (white-to-white distance [WTW], angle-to-angle [ATA], and sulcus-to-sulcus [STS]) in predicting postoperative vault and to formulate an optimized predictive model. METHODS: In this retrospective study, a cohort of 465 patients (comprising 769 eyes) who underwent the implantation of the V4c implantable Collamer lens with a central port (ICL) for myopia correction was examined. Least absolute shrinkage and selection operator (LASSO) regression and classification models were used to predict postoperative vault. The influences of WTW, ATA, and STS on predicting the postoperative vault and ICL size were analyzed and compared. RESULTS: The dataset was randomly divided into training (80%) and test (20%) sets, with no significant differences observed between them. The screened variables included only seven variables which conferred the largest signal in the model, namely, lens thickness (LT, estimated coefficients for logistic least absolute shrinkage of -0.20), STS (-0.04), size (0.08), flat K (-0.006), anterior chamber depth (0.15), spherical error (-0.006), and cylindrical error (-0.0008). The optimal prediction model depended on STS (R2=0.419, RMSE=0.139), whereas the least effective prediction model relied on WTW (R2=0.395, RMSE=0.142). In the classified prediction models of the vault, classification prediction of the vault based on STS exhibited superior accuracy compared to ATA or WTW. CONCLUSIONS: This study compared the capabilities of WTW, ATA, and STS in predicting postoperative vault, demonstrating that STS exhibits a stronger correlation than the other two parameters.


Asunto(s)
Implantación de Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Miopía/cirugía , Miopía/fisiopatología , Masculino , Femenino , Adulto , Periodo Posoperatorio , Refracción Ocular/fisiología , Adulto Joven , Cámara Anterior/patología , Cámara Anterior/diagnóstico por imagen , Biometría/métodos , Estudios de Seguimiento , Persona de Mediana Edad
6.
Graefes Arch Clin Exp Ophthalmol ; 262(7): 2321-2328, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38372752

RESUMEN

PURPOSE: To explore whether implantable collamer lens implantation has any effect on the postoperative objective indicators of dry eye and to determine the severity of its influence on each indicator. METHODS: This prospective observational trial was performed in the Department of Ophthalmology of West China Hospital and was approved by the Biomedical Ethics Sub-Committee of the West China Hospital of Sichuan University. A total of 89 non-dry eye patients (178 eyes in total) who received ICL implantation surgery at West China Hospital of Sichuan University were enrolled. The noninvasive keratograph tear film breakup time (NIKBUT), noninvasive keratograph tear meniscus height (NIKTMH), score of lipid layer, score of meibomian gland function, and hyperemia index were obtained via the OCULUS Keratograph for all subjects before surgery and at 1 week, 1 month, and 3 months after surgery. The fluorescein tear film breakup time (FBUT), corneal fluorescein staining score (CFS), and Schirmer test I were also measured at the same time. RESULTS: A total of 178 eyes completed the 1-week and 1-month follow-up, and 40 eyes completed the 3-month follow-up. Compared with the preoperative baseline, there was no significant difference in the NIKBUT or the corneal fluorescein staining score at each follow-up time point (P > 0.05, P > 0.05, P > 0.05). The FBUT and Schirmer test I at 1 week, 1 month, and 3 months after surgery were significantly higher than the preoperative baseline (P < 0.01, P < 0.01, P < 0.01). The NIKTMH and the score of lipid layer were significantly lower than the preoperative baseline at 1 week, 1 month, and 3 months after surgery (P < 0.01, P < 0.01, P < 0.05). The score of meibomian gland function and hyperemia index were significantly lower than the preoperative baseline 1 week after surgery (P < 0.01). CONCLUSION: ICL implantation has no adverse effect on the occurrence of postoperative dry eye, but it reduces the basal tear secretion of patients after surgery and has adverse effects on the indices of meibomian gland function in the short term postoperatively.


Asunto(s)
Síndromes de Ojo Seco , Miopía , Lentes Intraoculares Fáquicas , Lágrimas , Humanos , Estudios Prospectivos , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/metabolismo , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/fisiopatología , Femenino , Masculino , Lágrimas/metabolismo , Lágrimas/fisiología , Adulto , Estudios de Seguimiento , Miopía/cirugía , Miopía/fisiopatología , Implantación de Lentes Intraoculares , Adulto Joven , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico , Glándulas Tarsales/metabolismo , Córnea/cirugía , Córnea/metabolismo , Córnea/patología
7.
BMC Ophthalmol ; 24(1): 347, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39148038

RESUMEN

BACKGROUND: Toxic anterior segment syndrome (TASS) is a rare, noninfectious inflammation that occurs after anterior segment surgery. We report a case herein that developed presumed atypical late-onset TASS after V4c implantable collamer lens (ICL) implantation surgery. CASE PRESENTATION: A 26-year-old man underwent ICL implantation surgeries of both eyes on two separate days. The 1-day and 7-day postoperative routine follow-up visits revealed no abnormalities. However, one month after surgery, dense white spots attached to the posterior surface and scattered ones to the anterior surface of ICL in the left eye were noted on anterior segment examination. His uncorrected distance visual acuity (UDVA) was 20/16 in both eyes and the fundus examination was normal. Despite the absence of typical clinical manifestations, late-onset TASS was suspect and intense topical steroid was administered. After 6 weeks of tapering topical steroid therapy, the white spots disappeared and the patient had no subjective complains throughout the treatment period. CONCLUSIONS: This case suggested that the traditionally considered acute and serious TASS could also present as delayed and insidious onset after ICL implantation surgery. Due to its variabilities, the awareness of TASS should be raised to ophthalmologists and regular follow-up visits should be emphasized to patients. Once TASS was suspected, intensive steroid therapy should be implemented in time.


Asunto(s)
Segmento Anterior del Ojo , Implantación de Lentes Intraoculares , Lentes Intraoculares Fáquicas , Humanos , Masculino , Adulto , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/patología , Lentes Intraoculares Fáquicas/efectos adversos , Implantación de Lentes Intraoculares/efectos adversos , Agudeza Visual , Complicaciones Posoperatorias/diagnóstico , Síndrome , Glucocorticoides/uso terapéutico
8.
BMC Ophthalmol ; 24(1): 175, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627709

RESUMEN

PURPOSE: The purpose of this study was to compare the preoperative anxiety, aqueous humor monocyte chemoattractant protein-1 (MCP-1) concentration, intraoperative pain, and degree of cooperation of the first eye implantable collamer lens (ICL) surgery with the second eye surgery, of the 1-day interval group with the 1-week interval group, and to investigate the possible causes of these differences, as well as to determine the appropriate interval between bilateral eye ICL surgeries. METHOD: The study was a prospective observational study. A total of 120 patients who underwent bilateral ICL surgery at the Department of Ophthalmology, West China Fourth Hospital, Sichuan University, from July to September 2023, were enrolled. The patients were divided into a 1-day interval group and a 1-week interval group. The ICL surgery was performed on both eyes according to the schedule. Anxiety levels, aqueous humor MCP1, cooperativeness, surgical time, pain and satisfaction, and patients' estimations of the time spent in the operation were recorded for each eye. The patients were instructed to recall the intraoperative pain of the first eye surgery after the operation of the second eye. Statistical analyses (two independent samples t-test,two paired samples t-test, the rank-sum test, the chi-square test, non-parametric test with multiple independent samples) were performed to compare the differences between each score in both eyes and two groups. Furthermore, we examined the relationship between pain levels and the reproductive history of the patients. RESULTS: In the 1-day interval group, male/female is 22/52, average age is 25.24±5.00. In the 1-week interval group, male/female is 17/29, average age is 25.39±5.57. There was no statistically significant difference between the two groups. In both groups, patients were less nervous, had significantly more pain, had less surgical satisfaction, had a longer estimated operative time, and had elevated preoperative MCP1 during the second eye operation. In the second eye surgery, the patient's cooperation worsened, but it did not lead to an increase in surgical time. A significant proportion of patients, particularly in the 1-week interval group, recalled experiencing reduced pain during the first eye surgery. The 1-week interval group had a higher difference in all indicators between the bilateral surgeries. In the second eye surgery, patients in the 1-week interval group experienced more severe pain, less cooperation, longer estimated operation duration, and a greater MCP1 than those in the 1-day interval group. CONCLUSION: Patients undergoing second eye ICL surgery had decreased nervousness, increased pain, decreased cooperation, and satisfaction, and increased MCP1 compared to the first eye surgery. It is recommended that an interval of about one week should be avoided between bilateral surgeries when developing a surgical schedule to improve patients' cooperation, satisfaction, and comfort.


Asunto(s)
Lentes Intraoculares , Miopía , Lentes Intraoculares Fáquicas , Femenino , Humanos , Masculino , Ojo , Implantación de Lentes Intraoculares , Miopía/cirugía , Dolor/cirugía , Estudios Prospectivos , Adulto Joven , Adulto
9.
BMC Ophthalmol ; 24(1): 318, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39080583

RESUMEN

PURPOSE: Measurement of corneal endothelial cells is critical for postoperative evaluation of phakic intraocular lens (pIOL) surgery. However, inter-instrument differences in corneal endothelial cell density (ECD) after pIOL implantation have not yet been reported. This study aimed to compare automated corneal endothelial cell analysis between CellChek-20 (Konan Medical, Hyogo, Japan) and EM-4000 (Tomey, Nagoya, Japan) in healthy and postoperative eyes with pIOL. METHODS: We retrospectively analyzed 154 healthy and 236 postoperative eyes after pIOL surgery. Endothelial cell measurements were performed using CellChek-20 and EM-4000 with autofocusing and automated image analysis. ECD, percentage of hexagonal cells (HEX), coefficient of variation in cell size (CoV), and central corneal thickness (CCT) were compared between the two devices. RESULTS: The ECDs of the two devices were highly correlated in both healthy (Spearman's correlation coefficient [r] = 0.805; p < 0.001) and postoperative (r = 0.901; p < 0.001) groups. ECD from CellChek-20 was higher than EM-4000 in both healthy (mean difference = 228.9 cells/mm2; p < 0.001) and postoperative (mean difference = 115.6 cells/mm2; p < 0.001) groups. The CCT values also showed a strong correlation in healthy eyes (r = 0.974; p < 0.001) and in postoperative eyes (r = 0.936; p < 0.001); however, significant inter-instrument differences were observed. HEX and CV showed significant differences and relatively weak correlations (r < 0.7) between the two devices in both healthy and postoperative groups. CONCLUSION: The ECD values between the two instruments were correlated, but that of the CellChek-20 was significantly higher than that of the EM-4000 in both healthy and postoperative eyes after pIOL surgery. Most previous studies have also shown that the Konan software overestimated the ECD compared to other products in automatic measurement mode. The possibility of measurement bias should be considered when replacing equipment used for corneal endothelial cell measurements.


Asunto(s)
Endotelio Corneal , Lentes Intraoculares Fáquicas , Humanos , Endotelio Corneal/patología , Femenino , Recuento de Células , Masculino , Adulto , Estudios Retrospectivos , Estudios Transversales , Periodo Posoperatorio , Adulto Joven , Implantación de Lentes Intraoculares , Persona de Mediana Edad , Miopía/cirugía
10.
BMC Ophthalmol ; 24(1): 70, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38360631

RESUMEN

BACKGROUND: Studies on the factors affecting vault after posterior chamber phakic Implantable Collamer Lens (ICL) have been carried out, but most of them are single-centered and subjective selections of parameters. The present study aimed to systematically analyze the factors for vault. METHODS: A systematic review of case series, case-control, and cohort studies derived from the articles published in PubMed, the Cochrane Library, Embase, Web of Science, CNKI, CBM, Wanfang and VIP, as well as ClinicalTrials, which were conducted to search for studies on factors of vault using four core terms: phakic intraocular lenses, vault, risk factor and observational study, from January 01, 1997, to February 20, 2023. The included studies were meta-analyzed quantitatively and described qualitatively. Subsequently, meta-regression and subgroup analysis were used. RESULTS: We identified 13 studies (1,607 subjects), and 14 factors were considered. Meta-analysis showed that anterior chamber depth (ACD), horizontal corneal white-to-white (hWTW), ICL-size, and age are dual effects of the abnormal vaults; anterior chamber volume (ACV) and lens thickness (LT) are a one-way effect; while axial length (AL), ICL- spherical equivalent (ICL-SE) and Km are insignificant. In addition, descriptive analysis of anterior chamber angle (ACA), horizontal sulcus to sulcus (hSTS), ciliary processes height (T value), crystalline lens rise (CLR), and gender showed that all factors except gender tend to have significant effects on vault. Sensitivity analysis showed stable combined results. Country and design respectively affect the heterogeneity in ACD and ICL-size at low vault, while design affects the heterogeneity in ACD at high vault. No publication bias exists. CONCLUSIONS: Vault after ICL is related to multiple factors, especially anterior segmental biologic parameters, and they are weighted differently. We hope to provide a reference for the selection and adjustment of ICL.


Asunto(s)
Cámara Anterior , Miopía , Lentes Intraoculares Fáquicas , Humanos , Miopía/cirugía , Miopía/fisiopatología , Implantación de Lentes Intraoculares/métodos , Factores de Riesgo , Agudeza Visual/fisiología , Longitud Axial del Ojo/patología
11.
BMC Ophthalmol ; 24(1): 252, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38867207

RESUMEN

BACKGROUND: To comparatively analyze the surgically induced astigmatism (SIA) of the anterior, posterior, and total corneas of eyes undertaking implantable collamer lens (ICL) implantation with temporal or superior corneal incisions. METHODS: One hundred and nine eyes of 109 patients who received ICL implantation were recruited: 40 eyes had temporal incisions and 69 eyes had superior incisions. Total corneal refractive power (TCRP); simulated keratometry of the anterior (Sim-KAnt) and posterior (Sim-KPost) corneal curvature; and astigmatism of the anterior (CAAnt), posterior (CAPost), and total (CATCRP) cornea were recorded through a Pentacam preoperatively and 3 months postoperatively. The SIA of the anterior, posterior, and total cornea were also compared between the two groups. RESULTS: There were no significant intergroup differences for TCRP, Sim-KAnt, Sim-KPost, CAAnt, CAPost, or CATCRP, preoperatively. However, values of CAAnt, CAPost, and CATCRP with temporal incision were significantly higher than those parameters with superior incision postoperatively. All of the SIA of the anterior, posterior, and total cornea were significantly lower for temporal incision than those with a superior incision (p < 0.001, p = 0.006 and p = 0.001 respectively). Meanwhile, the superior incisions created against-the-rule (ATR) astigmatism, and temporal incisions always induce with-the-rule (WTR) astigmatism in total cornea. CONCLUSIONS: A superior incision may be suitable for correcting WTR astigmatism, while a temporal incision for correcting ATR astigmatism when using a non-toric ICL. Meanwhile, temporal incision could be a better choice with little preoperative astigmatism or that preoperative astigmatism would be corrected with toric ICLs. TRIAL REGISTRATION: Registration number: ChiCTR2100051739. Prospectively registered: 01 October 2021.


Asunto(s)
Astigmatismo , Córnea , Implantación de Lentes Intraoculares , Lentes Intraoculares Fáquicas , Refracción Ocular , Agudeza Visual , Humanos , Astigmatismo/etiología , Astigmatismo/fisiopatología , Astigmatismo/cirugía , Femenino , Masculino , Adulto , Córnea/cirugía , Refracción Ocular/fisiología , Adulto Joven , Miopía/cirugía , Miopía/fisiopatología , Persona de Mediana Edad , Topografía de la Córnea , Estudios Retrospectivos , Complicaciones Posoperatorias/diagnóstico , Estudios Prospectivos
12.
BMC Ophthalmol ; 24(1): 349, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39152392

RESUMEN

BACKGROUND: Accurate prediction of postoperative vault in implantable collamer lens (ICL) implantation is crucial; however, current formulas often fail to account for individual anatomical variations, leading to suboptimal visual outcomes and necessitating improved predictive models. We aimed to verify the prediction accuracy of our new predictive model for vaulting based on anterior and posterior chamber structural parameters. METHODS: This retrospective observational study included 137 patients (240 eyes) who previously underwent ICL surgery. Patients were randomly divided into the model establishment (192 eyes) or validation (48 eyes) groups. Preoperative measurements of the anterior and posterior chamber structures were obtained using Pentacam, CASIA2 anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy, and other devices. Stepwise multiple linear regression analysis was used to evaluate the relationship between the vault and each variable (WL formula). The Friedman test was performed for the vaulting prediction results of the WL, NK (Ver. 3), and KS formulas (Ver. 4) in CASIA2 AS-OCT, as well as the Zhu formula and vault measurements. The proportions of prediction error within ± 250 µm per formula were compared. RESULTS: The predicted vault values of the WL, NK, KS, and Zhu formulas and vault measurements were 668.74 ± 162.12, 650.85 ± 248.47, 546.56 ± 128.99, 486.56 ± 210.76, and 716.06 ± 233.84 µm, respectively, with a significant difference (χ2 = 69.883, P = 0.000). Significant differences were also found between the measured vault value and Zhu formula, measured vault value and KS formula, WL formula and Zhu formula, WL formula and KS formula, NK formula and KS formula, and NK formula and Zhu formula (P < 0.001) but not between other groups. The proportions of prediction error within ± 250 µm per formula were as follows: WL formula (81.3%) > NK formula (70.8%) > KS formula (66.7%) > Zhu formula (54.2%). CONCLUSIONS: The WL formula, which considers the complexity of the anterior and posterior chamber structures, demonstrates greater calculation accuracy, compared with the KS (Ver. 4) and Zhu formulas. The proportion of absolute prediction error ≤ 250 µm is higher with the WL formula than with the NK formula (ver. 3). This enhanced predictive capability can improve ICL sizing decisions, thereby increasing the safety and efficacy of ICL implantation surgeries.


Asunto(s)
Implantación de Lentes Intraoculares , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Femenino , Masculino , Tomografía de Coherencia Óptica/métodos , Adulto , Implantación de Lentes Intraoculares/métodos , Cámara Anterior/diagnóstico por imagen , Lentes Intraoculares Fáquicas , Miopía/cirugía , Microscopía Acústica/métodos , Adulto Joven , Persona de Mediana Edad , Agudeza Visual , Biometría/métodos , Refracción Ocular/fisiología
13.
BMC Ophthalmol ; 24(1): 326, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39103785

RESUMEN

PURPOSE: To research the accuracy of intraocular lens (IOL) calculation formulas and investigate the effect of anterior chamber depth (ACD) and lens thickness (LT) measured by swept-source optical coherence tomography biometer (IOLMaster 700) in patients with posterior chamber phakic IOL (PC-pIOL). METHODS: Retrospective case series. The IOLMaster 700 biometer was used to measure axial length (AL) and anterior segment parameters. The traditional formulas (SRK/T, Holladay 1 and Haigis) with or without Wang-Koch (WK) AL adjustment, and new-generation formulas (Barret Universal II [BUII], Emmetropia Verifying Optical [EVO] v2.0, Kane, Pearl-DGS) were utilized in IOL power calculation. RESULTS: This study enrolled 24 eyes of 24 patients undergoing combined PC-pIOL removal and cataract surgery at Xiamen Eye Center of Xiamen University, Xiamen, Fujian, China. The median absolute prediction error in ascending order was EVO 2.0 (0.33), Kane (0.35), SRK/T-WKmodified (0.42), Holladay 1-WKmodified (0.44), Haigis-WKC1 (0.46), Pearl-DGS (0.47), BUII (0.58), Haigis (0.75), SRK/T (0.79), and Holladay 1 (1.32). The root-mean-square absolute error in ascending order was Haigis-WKC1 (0.591), Holladay 1-WKmodified (0.622), SRK/T-WKmodified (0.623), EVO (0.673), Kane (0.678), Pearl-DGS (0.753), BUII (0.863), Haigis (1.061), SRK/T (1.188), and Holladay 1 (1.513). A detailed analysis of ACD and LT measurement error revealed negligible impact on refractive outcomes in BUII and EVO 2.0 when these parameters were incorporated or omitted in the formula calculation. CONCLUSION: The Kane, EVO 2.0, and traditional formulas with WK AL adjustment displayed high prediction accuracy. Furthermore, the ACD and LT measurement error does not exert a significant influence on the accuracy of IOL power calculation formulas in highly myopic eyes implanted with PC-pIOL.


Asunto(s)
Biometría , Catarata , Lentes Intraoculares Fáquicas , Refracción Ocular , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Femenino , Masculino , Persona de Mediana Edad , Biometría/métodos , Refracción Ocular/fisiología , Catarata/complicaciones , Adulto , Óptica y Fotónica , Reproducibilidad de los Resultados , Anciano , Longitud Axial del Ojo/diagnóstico por imagen , Longitud Axial del Ojo/patología , Cámara Anterior/diagnóstico por imagen , Agudeza Visual/fisiología , Implantación de Lentes Intraoculares/métodos
14.
Klin Monbl Augenheilkd ; 241(8): 923-943, 2024 Aug.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-38242162

RESUMEN

Although the safety of phakic intraocular lenses (pIOLs) has been continuously improved over 70-years of development, high endothelial cell losses can occur even with current pIOL models. Numerous studies have demonstrated that the distance of a pIOL to the corneal endothelium plays a crucial role in the extent of endothelial cell loss. For this reason alone, higher endothelial cell loss tends to be observed with anterior chamber lenses than with posterior chamber lenses. Adequate preoperative anterior chamber depth is essential, at least for iris-fixed pIOLs, in order to ensure a safe distance from the endothelium. However, the anterior chamber becomes shallower with age and therefore it may be useful to consider patient age in the safety criteria. Although endothelial cell loss is generally low with current pIOL models, regular monitoring of the endothelial cell density remains essential due to large interindividual differences in patients with pIOLs. If the endothelial cell loss is greater than expected and the follow-up visits confirm the trend, the pIOL should be explanted without delay. The endothelial reserve should be considered on an individual basis by taking into account patient age, physiological endothelial cell loss, and loss due to further surgery. With careful indication and long-term patient care, pIOLs remain a safe treatment option.


Asunto(s)
Pérdida de Celulas Endoteliales de la Córnea , Lentes Intraoculares Fáquicas , Humanos , Pérdida de Celulas Endoteliales de la Córnea/etiología , Pérdida de Celulas Endoteliales de la Córnea/patología , Endotelio Corneal/patología , Resultado del Tratamiento , Medicina Basada en la Evidencia
15.
Int Ophthalmol ; 44(1): 94, 2024 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-38368308

RESUMEN

PURPOSE: In the conventional technique, viscoelastic agents are typically rinsed away with balanced salt solution (BSS), but it may lead to a series of complications such as viscoelastic residue, anterior chamber instability and intraoperative TICL rotation. The utilization of irrigation and aspiration (I/A) has been shown to be effective in maintaining anterior chamber stability, reducing the incidence of postoperative high intraocular pressure, and minimizing postoperative fundus complications. However, there is a lack of previous studies investigating the impact of I/A on corneal endothelial cells during ICL implantation. The objective of this study was to examine the effect of I/A on corneal endothelial cells in patients undergoing myopia correction through implantation of Implantable Collamer Lens with a central hole (V4c ICL). METHODS: A retrospective selection was made of 344 eyes from 172 patients who underwent V4c ICL implantation and I/A to remove viscoelastic agent from the anterior chamber between 2021 and 2022. The intraocular pressure (IOP) was measured at 1 h, 2 h and 3 h after surgery. Corneal endothelial cell density (ECD), coefficient of variation in cell size (CV), standard deviation of cell area (SD), and percentage of hexagonal cells (HEX) were evaluated at 1 week postoperatively to assess corneal endothelial cells. The first two represent polymegethism or morphological variation, while the third parameter represents the degree of polymorphism of the corneal endothelial cells. Electronic medical records were utilized for data collection purpose. RESULTS: All surgeries proceeded without complications. The IOP was 16.50 ± 3.42 mmHg (range: 11.5-22.3 mmHg) prior to surgery and increased to 21.25 ± 5.61 mmHg (range: 9.5-34.8 mmHg), 19.85 ± 5.18 mmHg (range: 11.4-36.2 mmHg) and finally settled at an average of 18.81 ± 4.57 mmHg (range: 10.1-38.8 mmHg) at the respective time points of 1 h, 2 h and 3 h after surgery. The preoperative ECD was recorded as being approximately 3004 ± 295 cell/mm2, which exhibited a marginal decreased of 1.17% postoperatively, resulting in an average ECD value of 2969 ± 303 cell/mm2 one week after surgery (P = 0.12). Similarly, the preoperative CV was determined as 31.10 ± 3.78%, and it experienced a slight reduction with an average CV value of 30.74 ± 3.77% at week after surgery (P = 0.21). And, the preoperative SD was reported as 104.76 ± 17.26, and it remained virtually unchanged with an average SD value of 104.85 ± 18.75 at one week after surgery (P = 0.95). The preoperative HEX was calculated as 55.38 ± 8.94%, and it remained its stability with an average HEX value of 55.45 ± 8.73% one week after surgery (P = 0.92). CONCLUSION: The utilization of I/A led to a slight decrease in postoperative ECD when compared to conventional surgical techniques. Nevertheless, the reduction in ECD remained within acceptable limits, taking into accout the avervantaged it offered, such as stabilization of the anterior chamber and decreased occurrence of viscoelastic residue after surgery. It is challenging to anticipate the long-term safety of corneal endothelial cells based on current short-term studies. However, this study provides a valuable reference indicating that neither anterior chamber irrigation nor I/A aspiration have an adverse impact on the safety of corneal endothelial cells in the short term. Further research is imperative to enhance our understanding of their effects over an extended period.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Refracción Ocular , Agudeza Visual , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Células Endoteliales , Miopía/cirugía
17.
Int Ophthalmol ; 44(1): 141, 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38492122

RESUMEN

PURPOSE: Phakic intraocular lenses treat higher degrees of myopia not possible previously with conventional refractive surgery. The aim of this study is to report the incidence and risk factors of retinal complications after posterior chamber PIOL implantation and assess the differences in biometric parameters between patients who developed such complications versus those who did not. METHODS: This retrospective study recruited 514 patients who underwent ICL implantation to correct myopia at a tertiary eye hospital center in the Eastern province of Saudi Arabia. Follow up period was at least one year. Medical records of the patients were reviewed to obtain the required data. Associations between respondents' characteristics and retinal complications were evaluated using the Chi-squared test. RESULTS: The mean (SD) age was 27.7 (± 6.5) years ranging from 18 to 47. Laser treatment was performed in 14 cases (2.7%). Retinal complications occurred in six cases (1.2%). The risk of retinal complication was significantly higher among patients with high axial length (OR = 1.3, 95% CI 1.2, 1.4) and patients with high pre-spherical equivalent before ICL (OR = 1.09, 95% CI 1.03, 1.4). CONCLUSION: Patients with higher axial length and higher pre-spherical equivalent before ICL implantation are at high risk of retinal complications.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Adulto Joven , Adulto , Implantación de Lentes Intraoculares/efectos adversos , Agudeza Visual , Estudios Retrospectivos , Arabia Saudita/epidemiología , Refracción Ocular , Miopía/epidemiología , Miopía/cirugía , Miopía/etiología , Lentes Intraoculares Fáquicas/efectos adversos , Hospitales , Estudios de Seguimiento
18.
Zhonghua Yan Ke Za Zhi ; 60(2): 168-175, 2024 Feb 11.
Artículo en Zh | MEDLINE | ID: mdl-38296322

RESUMEN

Objective: To analyze the early changes in vault height and its influencing factors after implantation of posterior chamber phakic intraocular lenses (pIOL). Methods: A retrospective case series study was conducted, including patients who underwent pIOL implantation at Zhongshan Ophthalmic Center, Sun Yat-sen University, from September 2020 to August 2021, and completed a 3-month follow-up. Data were collected from myopic or myopic astigmatism patients. Preoperative ocular examinations, including Pentacam anterior segment analysis system, Sirius anterior segment analysis system, ultrasound biomicroscopy (UBM), and IOLMaster optical biometry, were performed to measure parameters such as refractive power, corneal curvature, corneal horizontal diameter, anterior chamber volume, anterior chamber depth, pupil diameter, sulcus-to-sulcus diameter (STS), and lens thickness. The degree and position of implanted pIOL, as well as vault height measured by anterior segment optical coherence tomography (AS-OCT) at 1 day, 1 week, 1 month, and 3 months postoperatively, were recorded. Statistical analyses were conducted using repeated measures analysis of variance, Pearson correlation analysis, and multiple linear regression analysis. Results: A total of 314 patients (314 eyes) were included, with 52 male (16.56%) and 262 female (83.44%) patients, and an average age of (26.44±4.60) years. The preoperative equivalent spherical power was (-8.09±2.41) D. Postoperative vault heights at 1 day, 1 week, 1 month, and 3 months were (671.88±273.02) µm, (652.26±272.21) µm, (615.08±259.69) µm, and (591.14±250.71) µm, respectively, with statistically significant differences among groups (P<0.001). Eyes with vault height>750 µm showed a greater decrease in early postoperative vault height (P<0.001). The eyes implanted with 12.1 mm pIOL had the lowest postoperative vault height, while those with 13.2 mm had the highest (P>0.05). Factors correlated with vault height at 1 day postoperatively included corneal horizontal diameter, anterior chamber depth, preoperative cylinder power, angle degree, lens thickness, and pIOL cylinder power. Factors correlated with vault height at 3 months postoperatively included corneal horizontal diameter, anterior chamber depth, preoperative cylinder power, anterior chamber volume, angle degree, lens thickness, axial length, pIOL spherical and cylinder power. Factors associated with changes in early postoperative vault height included corneal curvature K2, anterior chamber depth, anterior chamber volume, pupil diameter, horizontal STS, vertical STS, axial length, and preoperative spherical power (all P<0.05). Multiple linear regression analysis revealed that lens thickness significantly influenced vault height at 1 day postoperatively, anterior chamber volume significantly influenced vault height at 3 months postoperatively, and pupil diameter significantly influenced changes in early postoperative vault height (all P<0.05). Conclusions: Vault height after pIOL implantation is unstable in the early postoperative period and gradually decreases within 3 months. A higher baseline vault height is associated with a greater decrease. Anterior chamber volume, pupil diameter, and lens thickness are influencing factors on vault height during the first 3 months postoperatively.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Masculino , Femenino , Adulto Joven , Adulto , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Cámara Anterior , Miopía/cirugía
19.
Zhonghua Yan Ke Za Zhi ; 60(6): 479-483, 2024 Jun 11.
Artículo en Zh | MEDLINE | ID: mdl-38825946

RESUMEN

Posterior chamber phakic intraocular lens implantation is a type of intraocular surgery. With advancements in implant materials and design, this procedure has seen rapid adoption and widespread use in ophthalmology clinics in recent years. However, the changes in surgical techniques and the occurrence of postoperative complications have raised safety concerns that require significant attention in clinical practice. This paper aims to address the key factors influencing the safety of posterior chamber phakic intraocular lens implantation, exploring relevant characteristics, mechanisms, and current challenges. By emphasizing the importance of this surgery and proposing effective measures, it aims to provide guidance for clinical practice, enhance the safety of posterior chamber phakic intraocular lens implantation, and foster the healthy advancement of this surgical technique.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares Fáquicas , Complicaciones Posoperatorias , Humanos , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/prevención & control , Miopía/cirugía
20.
Zhonghua Yan Ke Za Zhi ; 60(7): 580-591, 2024 Jul 11.
Artículo en Zh | MEDLINE | ID: mdl-38955760

RESUMEN

Objective: To observe the impact of implantable Collamer lens (ICL) implantation surgery on choroidal thickness and blood flow density in myopic patients. Methods: This was a prospective cohort study. Patients undergoing ICL surgery at Qingdao University Affiliated Hospital between June 2021 and May 2023 were consecutively enrolled. Patients were categorized into high myopia (HM) and super high myopia (SHM) groups based on whether their spherical equivalence power exceeded 10.00 D. Comprehensive ophthalmic examinations, including optical coherence tomography, optical coherence tomography angiography, visual acuity assessment, intraocular pressure measurement, and optometry, were performed preoperatively and at 1 week, 1 month, and 3 months postoperatively. Results: A total of 42 patients (84 eyes), with an average age of (25.27±3.18) years, comprising 11 males and 31 females, were enrolled in the study. Among them, 20 patients belonged to the HM group, while 22 patients were in the SHM group. Both choroidal thickness and blood flow density exhibited significant increases at postoperative 1 week and 1 month compared to preoperative levels (P<0.05), but returned to baseline levels by postoperative 3 months. Specifically, the subfoveal choroidal thickness increased from (169.49±61.57) µm preoperatively to (180.16±66.61) µm at 1 week, (186.69±63.32) µm at 1 month, and then reverted to (169.58±60.82) µm at 3 months. The central choroidal blood flow density showed changes from 60.03%±1.60% preoperatively to 61.04%±1.17% at 1 week, 60.42%±1.81% at 1 month, and 60.22%±1.57% at 3 months. Furthermore, the HM group exhibited more pronounced changes in both choroidal thickness and blood flow density across all time points compared to the SHM group. Significant differences were observed in choroidal thickness changes at various areas at 1 month, while changes in blood flow density in specific areas were significant. However, no significant differences were noted at 3 months postoperatively. Correlation analysis revealed a negative correlation of changes in subfoveal choroidal thickness and central choroidal blood flow density postoperatively at 1 week and 3 months with preoperative choroidal blood flow density. Notably, no correlation was found between preoperative choroidal thickness and postoperative changes. Conclusions: In the early period following ICL implantation, the increase in choroidal thickness and blood flow density may be more pronounced in HM compared to SHM, but the two parameters can return to baseline levels by 3 months. ICL implantation transiently affects the fundus microenvironment in myopic patients, with implications of preoperative choroidal blood flow.


Asunto(s)
Coroides , Implantación de Lentes Intraoculares , Miopía , Humanos , Coroides/irrigación sanguínea , Femenino , Masculino , Estudios Prospectivos , Adulto , Miopía/cirugía , Implantación de Lentes Intraoculares/métodos , Lentes Intraoculares Fáquicas , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA