Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 913
Filtrar
Más filtros

Intervalo de año de publicación
1.
MMWR Recomm Rep ; 73(1): 1-32, 2024 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-38319847

RESUMEN

This report provides new CDC recommendations for tests that can support a diagnosis of syphilis, including serologic testing and methods for the identification of the causative agent Treponema pallidum. These comprehensive recommendations are the first published by CDC on laboratory testing for syphilis, which has traditionally been based on serologic algorithms to detect a humoral immune response to T. pallidum. These tests can be divided into nontreponemal and treponemal tests depending on whether they detect antibodies that are broadly reactive to lipoidal antigens shared by both host and T. pallidum or antibodies specific to T. pallidum, respectively. Both types of tests must be used in conjunction to help distinguish between an untreated infection or a past infection that has been successfully treated. Newer serologic tests allow for laboratory automation but must be used in an algorithm, which also can involve older manual serologic tests. Direct detection of T. pallidum continues to evolve from microscopic examination of material from lesions for visualization of T. pallidum to molecular detection of the organism. Limited point-of-care tests for syphilis are available in the United States; increased availability of point-of-care tests that are sensitive and specific could facilitate expansion of screening programs and reduce the time from test result to treatment. These recommendations are intended for use by clinical laboratory directors, laboratory staff, clinicians, and disease control personnel who must choose among the multiple available testing methods, establish standard operating procedures for collecting and processing specimens, interpret test results for laboratory reporting, and counsel and treat patients. Future revisions to these recommendations will be based on new research or technologic advancements for syphilis clinical laboratory science.


Asunto(s)
Sífilis , Humanos , Estados Unidos , Sífilis/diagnóstico , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum , Pruebas Serológicas , Centers for Disease Control and Prevention, U.S.
2.
J Clin Microbiol ; 62(8): e0047624, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39007562

RESUMEN

Using sequential immunoassays for the screening of blood donors is well described for viral serology testing but not for the screening of syphilis. In this study, we report the evaluation results and 2-year sequential testing data using two highly sensitive automated serology assays, the Alinity s Syphilis chemiluminescent immunoassay for screening, with all repeatedly reactive samples then tested on the Elecsys Syphilis electrochemiluminescence immunoassay. We screened 1,767,782 blood donor samples between 7 July 2021 and 6 July 2023 and found the Alinity false-positive rate to be low at 0.08% (1,456/1,767,782). The common false-positive rate between the two assays was also low (3.83%, 58/1,514). Concordantly reactive samples were further tested using a Treponema pallidum particle agglutination test, a rapid plasma reagin test, and a fluorescent treponemal antibody absorption test. There were 262/1,376 concordantly reactive Alinity and Elecsys blood donor samples with reactivity on one or more of the confirmatory tests. A total of 26/1,376 donors had a current syphilis infection, 152/1,376 reported a past history of syphilis and had been treated, and 84/1,376 did not report a past history of syphilis. We suggest that future studies could explore the use of sequential immunoassays to aid in the serodiagnosis for syphilis. IMPORTANCE: The serodiagnosis for syphilis usually follows two methodologies-a "traditional" algorithm using a non-treponemal test followed by confirmation using a treponemal test, or a "reverse" algorithm using a treponemal test followed by a non-treponemal test. There are limited reports in the literature of using a modified reverse algorithm (treponemal test followed by a second treponemal test), and to the best of knowledge, there are currently no published articles using two highly sensitive automated immunoassays to aid the serodiagnosis of syphilis. In addition, the Treponema pallidum particle agglutination (TPPA) assay is commonly used as a confirmatory test for the diagnosis of syphilis. With the withdrawal of the TPPA assay from Australia and presumably from the global market also, alternative testing algorithms are now required. This study provides proof of concept for using sequential immunoassays in the diagnosis of syphilis.


Asunto(s)
Donantes de Sangre , Serodiagnóstico de la Sífilis , Sífilis , Treponema pallidum , Humanos , Sífilis/diagnóstico , Sífilis/sangre , Inmunoensayo/métodos , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum/inmunología , Tamizaje Masivo/métodos , Anticuerpos Antibacterianos/sangre , Reacciones Falso Positivas , Automatización de Laboratorios/métodos , Sensibilidad y Especificidad , Femenino , Masculino
3.
Sex Transm Dis ; 51(6): 420-424, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38372524

RESUMEN

BACKGROUND: Syphilis in Florida increased 49% from 2016 to 2020. Moreover, many serological tests for syphilis (STS) do not indicate current infection. Traditionally, syphilis surveillance systems used reactor grids, a method for prioritizing STS for investigation based on age, nontreponemal titer, and/or sex. In 2022, Florida's sexually transmitted disease surveillance system implemented an automated method for processing electronically reported STS (eSTS), expanding upon the reactor grid, using an individual's current STS (treponemal and nontreponemal), treatment history, and historical STS results aiming for more efficiently processing eSTS. We compared the new method of processing eSTS results against the reactor grid and determined potential value in time/cost savings of this change. METHODS: All eSTSs (n = 4144) from January 2, 2023 to January 8, 2023, were compared by how the logic-based method processed test results versus how the reactor grid processed test results. Each method was compared using measurements of accuracy (e.g., sensitivity/specificity). Time and cost savings in eSTS processing were estimated. RESULTS: Using the surveillance case definition as reference, the accuracy of the logic-based method for processing eSTS was nearly double (82.3% vs. 43.6%), had greater specificity (79.0% vs. 33.0%), and increased positive predictive value (47.5% vs. 22.0%) when compared with the reactor grid method. Sensitivity (99.5% vs. 98.6%) and negative predictive value (99.9% vs. 99.2%) remained similar. The logic-based method is estimated to save 7783 hours annually (~$185,000). CONCLUSIONS: Processing eSTS based on current and historical STS results is significantly more accurate than using a reactor grid. Moreover, these improvements save time and resources that can be better allocated to other program prevention activities.


Asunto(s)
Serodiagnóstico de la Sífilis , Sífilis , Humanos , Sífilis/diagnóstico , Sífilis/epidemiología , Florida/epidemiología , Serodiagnóstico de la Sífilis/métodos , Masculino , Femenino , Adulto , Sensibilidad y Especificidad , Persona de Mediana Edad , Treponema pallidum/inmunología , Treponema pallidum/aislamiento & purificación , Adulto Joven , Pruebas Serológicas , Adolescente
4.
Vox Sang ; 119(8): 821-826, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38946160

RESUMEN

BACKGROUND AND OBJECTIVES: The detection of treponemal antibodies, which are used to make a diagnosis of syphilis, is important both for diagnostic purposes and as a mandatory blood donor test in most countries. We evaluated the feasibility of using Kode Technology to make syphilis peptide red cell kodecytes for use in column agglutination serologic platforms. MATERIALS AND METHODS: Candidate Kode Technology function-spacer-lipid (FSL) constructs were made for the Treponema pallidum lipoprotein (TmpA) of T. pallidum, using the peptide and FSL selection algorithms, and then used to make kodecytes. Developmental kodecytes were evaluated against a large range of syphilis antibody reactive and non-reactive samples in column agglutination platforms and compared against established methodologies. Overall, 150 reactive and 2072 non-reactive Syphicheck assay (a modified T. pallidum particle agglutination) blood donor samples were used to evaluate the agreement rate of the developed kodecyte assay. RESULTS: From three FSL-peptide candidate constructs, one was found to be the most suitable for diagnostics. Of 150 Syphicheck assay reactive samples, 146 were TmpA-kodecyte reactive (97.3% agreement), compared with 58.0% with the rapid plasmin reagin (RPR) assay for the same samples. Against the 2072 expected syphilis non-reactive samples the agreement rate for TmpA-kodecytes was 98.8%. CONCLUSION: TmpA-kodecytes are viable for use as cost-effective serologic reagent red cells for the detection of treponemal antibodies to diagnose syphilis with a high level of specificity in blood centres. This kodecyte methodology also potentially allows for introduction of the reverse-algorithm testing into low-volume laboratories, by utilizing existing transfusion laboratory infrastructure.


Asunto(s)
Antígenos Bacterianos , Lipoproteínas , Sífilis , Treponema pallidum , Humanos , Treponema pallidum/inmunología , Sífilis/diagnóstico , Sífilis/sangre , Lipoproteínas/inmunología , Antígenos Bacterianos/inmunología , Eritrocitos/microbiología , Pruebas de Aglutinación/métodos , Serodiagnóstico de la Sífilis/métodos , Anticuerpos Antibacterianos/sangre
5.
BMC Infect Dis ; 24(Suppl 1): 194, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38418989

RESUMEN

BACKGROUND: Sexually transmitted infections (STIs) such as syphilis and HIV remain to be a significant public health issue worldwide. Dual rapid point-of-care tests (POCTs) have shown promise for detecting antibodies to HIV and syphilis but have not been fully evaluated in the field. Our study supported the WHO ProSPeRo study on Sexually Transmitted Infection Point-of-Care Testing (STI POCT) by providing external quality assessment (EQA) for HIV and syphilis testing in reference laboratories and their associated clinical sites in seven countries. METHODS: HIV/syphilis serum liquid and dried tube specimen (DTS) panels were prepared by CDC. Liquid panels were distributed to the reference laboratories for three rounds of testing using commercially and locally available laboratory-based serological tests. DTS panels were sent to the clinical testing sites for 8 rounds of POC testing using the Abbott SD BIOLINE HIV/Syphilis Duo test (hereafter referred to as SD BIOLINE) and the Chembio Dual Path Platform (DPP) HIV-Syphilis assay. EQA panels were tested at CDC using the Rapid Plasma Reagin (RPR) test and the Treponema pallidum Particle Agglutination assay (TP-PA) for syphilis antibodies. Genetic Systems HIV-1/HIV-2 Plus O EIA, Geenius HIV Supplemental Assay and the Oraquick Advance HIV test were used to detect HIV antibodies in the EQA panels. Results from the reference laboratories and POCT sites were compared to those obtained at the CDC and a percentage agreement was calculated. RESULTS: Qualitative RPR and TP-PA performed at the reference laboratories demonstrated 95.4-100% agreement with CDC results while quantitative RPR and TP-PA tests demonstrated 87.7% and 89.2% agreement, respectively. A 93.8% concordance rate was observed for qualitative HIV testing in laboratories. EQA testing at clinical sites using dual tests showed 98.7% and 99.1% agreement for detection of HIV antibodies and eight out of 10 sites had > 95.8% agreement for syphilis testing. However, two clinical sites showed only 65.0-66.7% agreement for SD BIOLINE and 84.0-86.7% for DPP, respectively, for syphilis testing. CONCLUSIONS: Overall, laboratories demonstrated high EQA performance in this study. Both HIV/syphilis POCTs gave expected results in the clinic-based evaluations using DTS. However, testing errors were identified in a few testing sites suggesting the necessity for continuous training and monitoring the quality of POC testing.


Asunto(s)
Infecciones por VIH , VIH-1 , Sífilis , Humanos , Treponema pallidum , Anticuerpos Anti-VIH , Infecciones por VIH/diagnóstico , Sensibilidad y Especificidad , Anticuerpos Antibacterianos , Pruebas en el Punto de Atención , Serodiagnóstico de la Sífilis/métodos , VIH-2 , Organización Mundial de la Salud , Sistemas de Atención de Punto
6.
BMC Infect Dis ; 24(Suppl 1): 313, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38486194

RESUMEN

INTRODUCTION: International guidelines recommend routine screening for syphilis (aetiological agent: Treponema pallidum subspecies pallidum) amongst key populations and vulnerable populations using tests detecting treponemal and non-treponemal antibodies. Whilst treponemal tests have high sensitivities and specificities, they differ regarding subjective or objective interpretation, throughput and workload. Chemiluminescence immunoassays (CLIAs) are cost- and time-effective automated methods for detecting treponemal antibodies. The Treponema pallidum particle agglutination assay (TPPA) has been considered the "gold standard" treponemal assay, however, this includes a highly manual procedure, low throughput and subjective interpretation. The present multi-country study evaluated the ADVIA Centaur® Syphilis CLIA (Siemens Healthcare) assay compared to the reference SERODIA-TP·PA® (Fujirebio Diagnostics) for the serodiagnosis of syphilis amongst men who have sex with men (MSM). METHOD: 1,485 MSM were enrolled in Brighton (UK), Malta, and Verona (Italy) as part of a larger WHO multi-country and multi-site ProSPeRo study. Ethical approval was obtained. Serum was tested with the ADVIA Centaur® Syphilis CLIA assay and SERODIA-TP·PA®, in accordance with the manufacturers' instructions, for a first round of validation. A second round of validation was carried out for discrepant results that were additionally tested with both Western Blot (Westernblot EUROIMMUN®) and an Immunoblot (INNO-LIA, Fujirebio Diagnostics). Sensitivity, specificity, positive and negative predictive value (PPV and NPV), likelihood ratios (positive/negative), and the Diagnostic Odds Ratio (DOR)/pre-post-test probability (Fagan's nomogram) were calculated. RESULTS: Out of 1,485 eligible samples analysed in the first phase, the SERODIA-TP·PA® identified 360 positive and 1,125 negative cases. The ADVIA Centaur® Syphilis CLIA assay (Siemens) identified 366 positives, missclassifying one TPPA-positive sample. In the second phase, the ADVIA Centaur® Syphilis CLIA resulted in 1 false negative and 4 false positive results. Considering the syphilis study prevalence of 24% (95% CI: 22-26.7), The sensitivity of the ADVIA Centaur® Syphilis CLIA assay was 99.7% (95% CI: 98.5-100), and the specificity was 99.4% (95% CI: 98.7-99.7). The ROC area values were 0.996 (95% CI: 0.992-0.999), and both the PPV and NPV values were above 98% (PPV 98.1%, 95% CI: 96.1-99.2; NPV 99.9%, 95% CI: 99.5-100). CONCLUSIONS: The ADVIA Centaur® Syphilis CLIA assay showed similar performance compared to the SERODIA-TP·PA®. Considering the study is based on QUADAS principles and with a homogeneous population, results are also likely to be generalisable to MSM population but potentially not applicable to lower prevalence populations routinely screened for syphilis. The automated CLIA treponemal assay confirmed to be accurate and appropriate for routine initial syphilis screening, i.e. when the reverse testing algorithm is applied.


Asunto(s)
Minorías Sexuales y de Género , Sífilis , Masculino , Humanos , Treponema pallidum , Homosexualidad Masculina , Anticuerpos Antibacterianos , Serodiagnóstico de la Sífilis/métodos , Pruebas Serológicas/métodos , Sensibilidad y Especificidad , Mediciones Luminiscentes/métodos , Aglutinación
7.
BMC Infect Dis ; 24(Suppl 1): 192, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38418941

RESUMEN

INTRODUCTION: Globally, the incidence of HIV and syphilis can be reduced by the use of validated point of care tests (POCTs). As part of the WHO PRoSPeRo Network, we aimed to evaluate the performance, acceptability, and operational characteristics of two dual HIV/syphilis POCTs (Bioline HIV/Syphilis Duo (Abbott) and DPP® HIV-Syphilis assay (Chembio) for the screening of HIV and syphilis amongst men who have sex with men (MSM). METHOD AND ANALYSES: A cross sectional study of 2,577 MSM in Italy, Malta, Peru, and the United Kingdom (UK) presenting to seven clinic sites, were enrolled. Finger prick blood was collected to perform POCTs and results compared with standard laboratory investigations on venepuncture blood. Acceptability and operational characteristics were assessed using questionnaires. Diagnostic meta-analysis was used to combine data from the evaluation sites. RESULTS: Based on laboratory tests, 23.46% (n = 598/2549) of participants were confirmed HIV positive, and 35.88% of participants (n = 901/2511) were positive on treponemal reference testing. Of all participants showing evidence of antibodies to Treponema pallidum, 50.56% (n = 455/900) were Rapid Plasma Reagin (RPR) test reactive. Of HIV positive individuals, 60.62% (n = 354/584) had evidence of antibodies to T. pallidum, and of these 60.45% (n = 214/354) exhibited reactive RPR tests indicating probable (co)infection. For Bioline POCT, pooled sensitivities and specificities for HIV were 98.95% and 99.89% respectively, and for syphilis were 73.79% and 99.57%. For Chembio pooled sensitivities and specificities for HIV were 98.66% and 99.55%, and for syphilis were 78.60% and 99.48%. Both tests can detect greater than 90% of probable active syphilis cases, as defined by reactive RPR and treponemal test results. These dual POCTs were preferred by 74.77% (n = 1,926) of participants, due to their convenience, and the operational characteristics made them acceptable to health care providers (HCPs). CONCLUSIONS: Both the Bioline and the Chembio dual POCT for syphilis and HIV had acceptable performance, acceptability and operational characteristics amongst MSM in the PRoSPeRo network. These dual POCTs could serve as a strategic, more cost effective, patient and healthcare provider (HCP) friendly alternative to conventional testing; in clinical and other field settings, especially those in resource-limited settings.


Asunto(s)
Infecciones por VIH , Minorías Sexuales y de Género , Sífilis , Masculino , Humanos , Sífilis/diagnóstico , Sífilis/epidemiología , Homosexualidad Masculina , Perú/epidemiología , Malta , Estudios Transversales , Treponema pallidum , Pruebas en el Punto de Atención , Serodiagnóstico de la Sífilis/métodos , Sensibilidad y Especificidad , Anticuerpos Antibacterianos , Infecciones por VIH/diagnóstico , Infecciones por VIH/epidemiología
8.
Clin Lab ; 70(8)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39193963

RESUMEN

BACKGROUND: A new chemiluminescence assay, the Anti-TP-Ⅱ assay, is going to be commercially available in clinical laboratories in China and other countries. This study examined the performance of the new assay for the detection of TP infection and compared it with that of the Anti-TP assay by using large amounts of clinical samples. METHODS: The precision, accuracy, anti-interference ability, and the clinical sensitivity and specificity of the Anti-TP-Ⅱ assay were evaluated. In addition, compared with those of the Anti-TP assay, the false positive and false negative rates of the Anti-TP-Ⅱ assay were evaluated for 2,436 clinical routine samples and 711 preselected Anti-TP assay reactive samples. Discrepancy of the samples was investigated with the recomLinec Treponema IgM/IgG kit or the Elecsys syphilis assay. RESULTS: The precision, accuracy, and anti-interference ability of the Anti-TP-Ⅱ assay met the national standard of China, and there was an overall agreement of 96.75% (Kappa = 0.91) between the two assays. The sensitivity and specificity of the Anti-TP-Ⅱ assay were 100% (95% CI: 94.13% to 100%) and 99.92% (95% CI: 99.70% to 99.99%), respectively. Compared with the Anti-TP assay, the Anti-TP-Ⅱ assay significantly reduced the number of borderline samples and the false positive rate. CONCLUSIONS: Considering its excellent performance, the Anti-TP-Ⅱ assay is a good screening test for high-throughput laboratories and can replace the previous generation of reagents, the Anti-TP assay, with a superior specificity.


Asunto(s)
Anticuerpos Antibacterianos , Mediciones Luminiscentes , Sensibilidad y Especificidad , Sífilis , Treponema pallidum , Humanos , Mediciones Luminiscentes/métodos , Treponema pallidum/inmunología , Sífilis/diagnóstico , Sífilis/microbiología , Sífilis/inmunología , Sífilis/sangre , Anticuerpos Antibacterianos/sangre , Anticuerpos Antibacterianos/inmunología , Reproducibilidad de los Resultados , Serodiagnóstico de la Sífilis/métodos , China , Reacciones Falso Positivas , Masculino , Femenino , Reacciones Falso Negativas
9.
J Infect Chemother ; 30(9): 899-903, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38460614

RESUMEN

INTRODUCTION: Serological tests of non-treponemal and treponemal types are the most frequently used for syphilis diagnosis. Nontreponemal tests are used to monitor disease activity. Toluidine red unheated serum test (TRUST), as one of nontreponemal tests, is generally applicable to hospitals at different levels. However, accurate judgment of TRUST results is inseparable from an experienced and accurate operator. To reduce current shortcomings of manual TRUST method, we attempted to convert the manual TRUST test into automatic TRUST test, that is, to determine the degree of aggregation of toluidine red particles by detecting the absorbance value of serum after reaction with toluidine red particles. METHODS: 50 µL of serum sample and 80 µL toluidine red particles were added to 96-well plate. Then, the 96-well plate was placed on a microplate reader at medium grade for 8 min to mix. Then, plasma reagin reacted with toluidine red particles and promoted the aggregation of toluidine red particles to form a large clot, which eventually caused a decrease in the absorbance at 540 nm. RESULTS: The results showed that the specificity of the automatic TRUST test was 100%, the sensitivity was 87%. And this method showed 93.5% correlation with manual TRUST test. The developed method is simple and involves less subjectivity in reading results, opening new avenues for syphilis diagnostic testing. CONCLUSION: Turbidimetric immunoassay can avoid the shortcomings of subjective interpretation, time-consuming and manual operation of manual TRUST method, and is more suitable for large-scale screening in health examination.


Asunto(s)
Anticuerpos Anticardiolipina , Sensibilidad y Especificidad , Sífilis , Humanos , Sífilis/diagnóstico , Sífilis/sangre , Anticuerpos Anticardiolipina/sangre , Cloruro de Tolonio , Serodiagnóstico de la Sífilis/métodos , Inmunoturbidimetría/métodos , Treponema pallidum/inmunología , Masculino , Inmunoensayo/métodos , Femenino , Pruebas de Aglutinación/métodos
10.
Euro Surveill ; 29(32)2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39119720

RESUMEN

BackgroundSyphilis in blood donors (BD) has increased in many countries.AimWe aimed to describe trends in syphilis seroposivity in BD in France, to identify risk factors and assess if a non-treponemic test (NTT) could define BD having recovered from syphilis for more than 1 year.MethodsThe analysis covered the period 2007 to 2022 and 45,875,939 donations. Of the 474 BD syphilis-positive in 2022, 429 underwent additional investigations with an NTT. History of syphilis was obtained at the post-donation interview or based on serology results for repeat donors.ResultsUntil 2021, positivity rates remained stable (mean: 1.18/10,000 donations, range: 1.01-1.38). An increased rate was observed in 2022 (1.74/10,000; p = 0.02). Over the whole study period, prevalence was 2.2 times higher in male than in female BD (4.1 times higher in 2022). The proportion of males with an identified risk factor who have sex with men increased from 16.7% in 2007 to 64.9% in 2022. Based on NTT, 79 (18%) of the donors who were seropositive in 2022 were classified as having been infected in the previous year. History of syphilis was available for 30 of them. All had an infection within the previous 3 years. Among seven donors with a syphilis < 12 months before testing, one had an NTT titre ≥ 8, three a titre between 1 and 4, three were negative.ConclusionSyphilis seropositivity increased considerably in BDs in 2022, mostly in males, notably MSM. Available data did not allow appropriate evaluation of the NTT to distinguish recent from past infection.


Asunto(s)
Donantes de Sangre , Serodiagnóstico de la Sífilis , Sífilis , Humanos , Donantes de Sangre/estadística & datos numéricos , Sífilis/epidemiología , Sífilis/diagnóstico , Sífilis/sangre , Masculino , Francia/epidemiología , Femenino , Adulto , Prevalencia , Factores de Riesgo , Serodiagnóstico de la Sífilis/métodos , Persona de Mediana Edad , Treponema pallidum/inmunología , Treponema pallidum/aislamiento & purificación , Estudios Seroepidemiológicos , Adulto Joven , Homosexualidad Masculina/estadística & datos numéricos
11.
J Clin Microbiol ; 61(6): e0016823, 2023 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-37219422

RESUMEN

Automated nontreponemal rapid plasma reagin (RPR) tests were recently introduced in the United States for syphilis testing and limited performance data are available. In collaboration with the Association of Public Health Laboratories, three public health laboratories (PHL) were chosen through a competitive selection process to evaluate the performance of three FDA-cleared automated RPR test systems: BioPlex 2200 Syphilis Total & RPR assay (Bio-Rad Laboratories), AIX 1000 (Gold Standard Diagnostics), and ASI Evolution (Arlington Scientific). Panels prepared at the CDC included: a qualitative panel comprised of 734 syphilis reactive/nonreactive sera; a quantitative panel of 50 syphilis reactive sera (RPR titer 1:64 to 1:1,024); and a reproducibility panel of 15 nonreactive and reactive sera (RPR titer 1:1 to 1:64). Panels were shipped frozen to the PHL and tested on the automated RPR systems following manufacturers' instructions. Prior test results were blinded to all laboratories. When compared to manual RPR (Arlington Scientific) performed at the CDC as a reference test, the qualitative panel results demonstrated an overall concordance of 95.9% for AIX 1000, 94.6% for ASI Evolution, and 92.6% for Bioplex RPR; quantitative panel showed within range titer of 2-fold for 94% of specimens for AIX 1000, 68% for ASI Evolution, and 64% for BioPlex RPR, and the reproducibility testing panel demonstrated point estimates ranging from 69 to 95%. Automated RPR instruments could reduce turnaround time and minimize interpretation errors. However, additional evaluations with more specimens could assist laboratories with implementing automated RPR tests and understanding their limitations.


Asunto(s)
Sífilis , Humanos , Sífilis/diagnóstico , Reaginas , Reproducibilidad de los Resultados , Anticuerpos Antibacterianos , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum
12.
Clin Lab ; 69(1)2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36649527

RESUMEN

BACKGROUND: Diagnosis of syphilis, a sexually transmitted infection, can be based on clinical information and various combinations of results of both non-treponemal and treponemal assays. Because understanding a patient population is helpful for test utilization in the clinical laboratory, we aimed to investigate the results of syphilis serology tests requested from local clinics in Korea. METHODS: We retrospectively evaluated the syphilis serology test results of serum Rapid Plasma Reagin (RPR), Treponema pallidum latex agglutination (TPLA), RPR titer, and fluorescent treponemal antibody absorption (FTA-ABS) IgG, and IgM tests performed in Korean adults in the laboratory information system of Green Cross Laboratories. We investigated the patterns of syphilis serology test results and possible interpretation according to combinations of syphilis serology based on a traditional testing algorithm. RESULTS: During the one-year study period, 33,746 RPR tests were performed in Korean adults (7,622 men and 26,124 women) with a median age of 35.1 years (interquartile range 30.8 - 43.4 years). Among these RPR tests, 317 (0.9%) showed RPR+ results and were performed simultaneous with TPLA tests. Among these 317 patients, 187 (59.0%) had RPR+/TPLA+ results. Among 130 patients with RPR+/TPLA- results, FTA-ABS IgG and IgM were only tested in 15 (11.5%): 14 were IgG-/IgM-, and one who underwent only the IgM test showed a negative result (probably a biological false positive of RPR). Among 187 RPR+/TPLA+ patients, 60 (2.1%) had RPR titer ≥ 1:8, and 10 were FTA-ABS IgM+ (including weak reactive results probably due to current infection or rare biological false-positive). Among 121 patients with RPR+/TPLA+/RPR titer ≤ 1:4, 30 were tested for FTA-ABS IgG and/or IgM: the two FTA-ABS IgM+ (including weak reactive) patients had an RPR titer of 1:4. CONCLUSIONS: This study will help to understand patient populations and test utilization for syphilis serology test interpretation in clinical laboratories in Korea. Further studies are needed to investigate the clinical impact of test utilization of syphilis serology in Korea.


Asunto(s)
Sífilis , Masculino , Adulto , Humanos , Femenino , Sífilis/diagnóstico , Sífilis/epidemiología , Estudios Seroepidemiológicos , Estudios Retrospectivos , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum , Inmunoglobulina G , Hospitales , Inmunoglobulina M , República de Corea/epidemiología
13.
Mikrobiyol Bul ; 57(1): 141-155, 2023 Jan.
Artículo en Turco | MEDLINE | ID: mdl-36636853

RESUMEN

Syphilis is a sexually transmitted disease caused by Treponema pallidum subsp. pallidum. This historical disease has diverse clinical manifestations making laboratory testing crucial for optimal patient management. Direct detection of T.pallidum by dark-field microscopy is possible when lesions are present. Culture of the bacteria is complex and not performed routinely. There is no well-validated commercially available polymerase chain reaction (PCR) test. Serological tests are currently the most common diagnostic methods adapted in clinical laboratories. They provide a presumptive diagnosis and used for screening, diagnosis, and follow-up of the treatment. They are divided into two groups, named as nontreponemal and treponemal tests and performed by the application of the traditional algorithm, the reverse sequence algorithm or European Centre for Disease Prevention and Control (ECDC) algorithm. The traditional algorithm starts with a nontreponemal test and a reactive result is confirmed with a treponemal test. In the reverse sequence algorithm, a treponemal test is used for screening and a reactive result is confirmed by a quantitative nontreponemal test. When the nontreponemal test is negative, a second different treponemal test preferably T.pallidum particle agglutination test (TPPA) is used. The ECDC algorithm recommends screening by a treponemal test such as T.pallidum enzym immunoassay (TP-EIA), T.pallidum chemiluminescence immunoassay (CIA) and if reactive, a reflex confirmatory treponemal test is performed. The treponemal tests become reactive a few weeks after infection and remain reactive even after successful treatment. The nontreponemal tests are used to assess disease activity and response to therapy. Serological tests have many limitations such as false-positivity, falsenegativity in various stages of the disease and also challenging difficulties when evaluating response to therapy. In recent years, rapid syphilis tests which are mostly treponemal-specific tests have been developed for high-prevalence populations in resource limited settings. There has been requirement for the utility of standart PCR and IgM testing in the diagnosis of congenital syphilis and neurosyphilis cases. In this review article, it was aimed to present the diagnostic tests, the algorithms, the correct indications for testing and interpretation of the test results to the likely corresponding clinical stage of the disease with in the perspective of recent advances.


Asunto(s)
Sífilis , Humanos , Sífilis/diagnóstico , Tamizaje Masivo , Treponema pallidum , Serodiagnóstico de la Sífilis/métodos , Técnicas de Laboratorio Clínico , Algoritmos , Anticuerpos Antibacterianos
14.
Forensic Sci Med Pathol ; 19(2): 215-220, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36763091

RESUMEN

A 43-year-old woman died suddenly and was found at PM to have a ruptured thoracic aortic aneurysm. The endothelial surface of the aorta showed a 'tree-bark' appearance. Histology of the aneurysm wall showed a patchy, mainly perivascular, plasma cell infiltrate. Multiple spirochete-like organisms were identified on T. pallidum IHC. However, PM syphilis serology (screen including rapid plasma reagin (RPR) and T. pallidum particle agglutination (TPPA)) on femoral blood was negative. PCR testing on FFPE aortic wall tissue was negative. Further history revealed routine antenatal syphilis screening tests had been negative, no known history or risk of exposure to syphilis or other treponemes. This case raises the possibility of false negative syphilis testing. While acknowledged in RPR testing, with the modern testing regime using multiple methods, the rate of false negative results is now thought to be markedly reduced, and false positive results are a much greater problem in clinical medicine. The most common cause of false negative results is early in primary infection before an immune response has been mounted and in those patients that are immunocompromised. False negative results are also more often seen in tertiary syphilis, as in this case. Newer testing methods which include 16S rRNA sequencing have become available and early discussion with a microbiologist would be recommended. Strong macroscopic and microscopic suggestion of syphilis as the cause of the aneurysm makes it necessary to include the possibility of infection in the Post Mortem Report to Coroner as this will have implications for her sexual partners and children.


Asunto(s)
Aneurisma de la Aorta Torácica , Rotura de la Aorta , Sífilis , Humanos , Niño , Femenino , Embarazo , Adulto , Sífilis/diagnóstico , Treponema pallidum , ARN Ribosómico 16S , Serodiagnóstico de la Sífilis/métodos
15.
Sex Transm Infect ; 98(5): 380-382, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34785619

RESUMEN

BACKGROUND: Primary syphilis is characterised by the appearance of an ulcerated lesion (chancre) on the anogenital or oral mucosa from which Treponema pallidum DNA may be detectable by PCR. Serological tests for syphilis may be non-reactive in early infection, even after the appearance of a chancre. We reviewed the use of a multiplex-PCR (M-PCR) test to determine the added value of T. pallidum DNA detection in the management of individuals presenting with mucocutaneous ulceration at a sexual health service in central London. METHODS: We performed a cross-sectional analysis of all individuals with detectable T. pallidum DNA from September 2019 to April 2020. Electronic patient records were reviewed and concomitant results for treponemal serology and/or rapid plasma reagin (RPR) extracted, along with demographic data, history of syphilis and indices of sexual behaviour including number of sexual partners contacted. Any subsequent treponemal serology and RPR results were also reviewed. RESULTS: M-PCR swab specimens were performed in 450 individuals, of whom 63 (14%) had detectable T. pallidum DNA; 60 of 63 (95%) were gay or bisexual men and 11 of 63 (17%) were living with HIV. A history of treated syphilis was present in 17 of 63 (27%). Same-day treponemal serology/RPR testing was performed in 58 of 63 (92%) patients. Of the 58 who had same-day syphilis serology/RPR, 9 (16%) had their syphilis infection confirmed by treponemal DNA PCR alone. A total of 165 partners were traced as contacts of infection, of whom 25 (15%) were contacts of individuals diagnosed by M-PCR testing alone. CONCLUSION: In individuals with T. pallidum PCR-positive lesions, around one in six in our cohort were negative on standard diagnostic serological tests for syphilis. Treponemal DNA testing is an important addition to serological assays in individuals with mucocutaneous ulceration who are at risk of recent syphilis infection and facilitates early diagnosis and contact tracing.


Asunto(s)
Chancro , Enfermedades de la Piel , Sífilis , Estudios Transversales , Humanos , Masculino , Reacción en Cadena de la Polimerasa/métodos , Sífilis/complicaciones , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum/genética , Úlcera/complicaciones , Úlcera/diagnóstico
16.
Sex Transm Dis ; 49(1): e11-e12, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34618786

RESUMEN

ABSTRACT: This study evaluated the performance of manual rapid plasma reagin (RPR) and automated AIX1000 RPR tests for the diagnosis of syphilis. Manual RPR showed a 3% reactive result compared with 5.8% for the automated test mainly because of RPR reactive results with low titers not confirmed by Treponema pallidum particle agglutination.


Asunto(s)
Reaginas , Sífilis , Anticuerpos Antibacterianos , Humanos , Sífilis/diagnóstico , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum
17.
Sex Transm Dis ; 49(6): 453-457, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35312664

RESUMEN

BACKGROUND: Automated chemiluminescent microparticle immunoassays (CMIAs) are the most common first step at high-volume laboratories for syphilis screening. If the initial screening test is reactive, 1 more treponemal test is required, resulting in increased cost. In this multicenter study, we aimed to determine the correlation between the CMIA signal-to-cutoff ratio (S/Co) and the confirmatory tests to reduce unnecessary confirmatory testing. METHODS: Eight hospitals from 5 provinces participated in this study. All laboratories used Architect Syphilis TP CMIA (Abbott Diagnostics, Abbott Park, IL) for initial screening. Treponema pallidum hemagglutination (TPHA), rapid plasma reagin (RPR), and fluorescent treponemal antibody absorption (FTA-ABS) were used as confirmatory tests according to the reverse or European Centre for Disease Prevention and Control algorithms. A receiver operating characteristic analysis was used to determine the optimal S/Co ratio to predict the confirmation results. RESULTS: We evaluated 129,346 serum samples screened by CMIA between January 2018 and December 2020. A total of 2468 samples were reactive; 2247 (91%) of them were confirmed to be positive and 221 (9%) were negative. Of the 2468 reactive specimens, 1747 (70.8%) had an S/Co ratio ≥10.4. When the S/Co ratios were ≥7.2 and ≥10.4, the specificity values were determined to be 95% and 100%, respectively. In a subgroup of 75 CMIA-positive patients, FTA-ABS was performed and 62 were positive. Among these FTA-ABS-positive patients, 24 had an S/Co ratio <10.4, and negative TPHA and RPR. CONCLUSIONS: We propose a potentially cost-effective reverse screening algorithm with a treponemal CMIA S/Co ratio ≥10.4, obviating the need for secondary treponemal testing in about 71% of the screening-reactive samples. This would substantially reduce the confirmatory testing volume and laboratory expenses. However, in high-risk group patients with CMIA positive results, S/Co ratio <10.4, and negative TPHA and RPR, FTA-ABS may be used for confirmation.


Asunto(s)
Sífilis , Anticuerpos Antibacterianos , Pruebas de Hemaglutinación , Humanos , Inmunoensayo , Técnicas para Inmunoenzimas , Serodiagnóstico de la Sífilis/métodos , Treponema pallidum
18.
Sex Transm Dis ; 49(2): 105-110, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34471079

RESUMEN

BACKGROUND: The prevalence of syphilis is increasing in the United States. The emergency department (ED) is an important setting to screen and treat underserved populations. To tailor testing protocols to the local population, we aimed to identify risk factors for syphilis positivity in ED patients. METHODS: We performed a retrospective analysis of ED patients who were screened for syphilis between November 2018 and August 2020. Patients were screened for Treponema pallidum antibody using a multiplex flow immunoassay, and positive results were confirmed by rapid plasma reagin or T. pallidum particle agglutination. Risk factors for new syphilis diagnoses were identified using multiple logistic regression. RESULTS: We screened 1974 patients for syphilis (mean age, 37 ± 16 years; 56% female). We identified 201 patients with new infections without previous treatment. Independent risk factors for a new diagnosis of syphilis included housing status (undomiciled, 23% [60 of 256]; domiciled, 9% [133 of 1559]; adjusted odds ratio [aOR], 1.9 [95% confidence interval {CI}, 1.2-3.0]), history of HIV (positive, 44% [28 of 63]; negative, 9% [173 of 1893]; aOR, 5.8 [95% CI, 3.0-11.2]), tobacco use (positive, 15% [117 of 797]; negative, 4% [29 of 665]; aOR, 2.4 [95% CI, 1.5-3.9]), and illicit drug use (positive, 14% [112 of 812]; negative, 8% [52 of 678]; aOR, 2.2 [95% CI, 1.0-2.5]). CONCLUSIONS: Undomiciled housing status, history of HIV, history of tobacco use, and history of illicit drug use were independently associated with a new diagnosis of syphilis in the ED. Broadening targeted syphilis screening algorithms beyond sexually transmitted disease-related complaints could help identify new syphilis cases for treatment.


Asunto(s)
Infecciones por VIH , Sífilis , Adulto , Servicio de Urgencia en Hospital , Femenino , Infecciones por VIH/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Sífilis/complicaciones , Sífilis/diagnóstico , Sífilis/epidemiología , Serodiagnóstico de la Sífilis/métodos , Adulto Joven
19.
JAMA ; 327(2): 161-172, 2022 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-35015033

RESUMEN

Importance: Approximately 1 in 5 adults in the US had a sexually transmitted infection (STI) in 2018. This review provides an update on the epidemiology, diagnosis, and treatment of gonorrhea, chlamydia, syphilis, Mycoplasma genitalium, trichomoniasis, and genital herpes. Observations: From 2015 to 2019, the rates of gonorrhea, chlamydia, and syphilis increased in the US; from 1999 to 2016, while the rates of herpes simplex virus type 1 (HSV-1) and HSV-2 declined. Populations with higher rates of STIs include people younger than 25 years, sexual and gender minorities such as men and transgender women who have sex with men, and racial and ethnic minorities such as Black and Latinx people. Approximately 70% of infections with HSV and trichomoniasis and 53% to 100% of extragenital gonorrhea and chlamydia infections are asymptomatic or associated with few symptoms. STIs are associated with HIV acquisition and transmission and are the leading cause of tubal factor infertility in women. Nucleic acid amplification tests have high sensitivities (86.1%-100%) and specificities (97.1%-100%) for the diagnosis of gonorrhea, chlamydia, M genitalium, trichomoniasis, and symptomatic HSV-1 and HSV-2. Serology remains the recommended method to diagnose syphilis, typically using sequential testing to detect treponemal and nontreponemal (antiphospholipid) antibodies. Ceftriaxone, doxycycline, penicillin, moxifloxacin, and the nitroimidazoles, such as metronidazole, are effective treatments for gonorrhea, chlamydia, syphilis, M genitalium, and trichomoniasis, respectively, but antimicrobial resistance limits oral treatment options for gonorrhea and M genitalium. No cure is available for genital herpes. Effective STI prevention interventions include screening, contact tracing of sexual partners, and promoting effective barrier contraception. Conclusions and Relevance: Approximately 1 in 5 adults in the US had an STI in 2018. Rates of gonorrhea, chlamydia, and syphilis in the US have increased, while rates of HSV-1 and HSV-2 have declined. Ceftriaxone, doxycycline, penicillin, moxifloxacin, and the nitroimidazoles are effective treatments for gonorrhea, chlamydia, syphilis, Mycoplasma genitalium, and trichomoniasis, respectively, but antimicrobial resistance limits oral therapies for gonorrhea and Mycoplasma genitalium, and no cure is available for genital herpes.


Asunto(s)
Enfermedades de Transmisión Sexual/diagnóstico , Enfermedades de Transmisión Sexual/tratamiento farmacológico , Infecciones Asintomáticas/epidemiología , Infecciones Asintomáticas/terapia , Infecciones por Chlamydia/diagnóstico , Infecciones por Chlamydia/tratamiento farmacológico , Infecciones por Chlamydia/epidemiología , Infecciones por Chlamydia/etnología , Trazado de Contacto , Farmacorresistencia Microbiana , Minorías Étnicas y Raciales/estadística & datos numéricos , Femenino , Gonorrea/diagnóstico , Gonorrea/tratamiento farmacológico , Gonorrea/epidemiología , Gonorrea/etnología , Infecciones por VIH/complicaciones , Infecciones por VIH/transmisión , Herpes Genital/diagnóstico , Herpes Genital/tratamiento farmacológico , Herpes Genital/epidemiología , Herpes Genital/etnología , Herpes Simple/diagnóstico , Herpes Simple/tratamiento farmacológico , Herpes Simple/epidemiología , Herpes Simple/etnología , Humanos , Masculino , Tamizaje Masivo , Infecciones por Mycoplasma/diagnóstico , Infecciones por Mycoplasma/tratamiento farmacológico , Infecciones por Mycoplasma/epidemiología , Infecciones por Mycoplasma/etnología , Mycoplasma genitalium , Técnicas de Amplificación de Ácido Nucleico , Distribución por Sexo , Minorías Sexuales y de Género/estadística & datos numéricos , Enfermedades de Transmisión Sexual/epidemiología , Enfermedades de Transmisión Sexual/etnología , Sífilis/diagnóstico , Sífilis/tratamiento farmacológico , Sífilis/epidemiología , Sífilis/etnología , Serodiagnóstico de la Sífilis/métodos , Vaginitis por Trichomonas/diagnóstico , Vaginitis por Trichomonas/tratamiento farmacológico , Vaginitis por Trichomonas/epidemiología , Vaginitis por Trichomonas/etnología , Estados Unidos/epidemiología
20.
Transfus Med ; 31(2): 121-128, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33480044

RESUMEN

BACKGROUND: The increasing incidence of syphilis worldwide has called attention to the risk of transmission by transfusion. AIMS: To determine the prevalence of active syphilis in blood donors and characterise the serological profile of syphilis-positive donors. METHODS: Samples positive for Treponema pallidum using the chemiluminescent microparticle immunoassay (CMIA) during blood donor screening from 2017 to 2018 were tested by the Venereal Disease Research Laboratory (VDRL) non-treponemal test and for anti-T. pallidum IgM by ELISA (Immunoassay Enzyme test for detection of IgM antibodies). The INNO-LIA Syphilis test (Line Immuno Assay solid test for confirmation antibodies to Treponema pallidum) was performed as a confirmatory test on samples that were positive on ELISA-IgM but negative on VDRL. ELISA-IgM (+) samples were also tested for T. pallidum DNA in sera by real-time polymerase chain reaction (PCR). RESULTS: Of 248 542 samples screened, 1679 (0.67%) were positive for syphilis by CMIA. Further analysis was performed on 1144 (68.1%) of these samples. Of those tested, 16% were ELISA IgM(+)/VDRL(+), 16.5% were ELISA IgM(-)/VDRL(+), 4.1% were ELISA IgM(+)/VDRL(-), and 63.4% were ELISA IgM (-)/VDRL(-). The INNO-LIA Syphilis test results were 33 (3%) positive, 2 (0.2%) undetermined and 12 (1%) negative. Of the 230 EIA-IgM(+) samples (20.1%), 5 (2.2%) were PCR positive. The prevalence of active syphilis in 2017 and 2018 was 0.1% and 0.07%, respectively, and overall prevalence of serologic markers for syphilis was highest among male, unmarried, 25-34-year-olds with a high school education and who were first-time donors. CONCLUSION: There is a risk of transfusion-transmitted syphilis in blood banks that exclusively use the VDRL test for donor screening, as is currently the situation in some Brazilian blood centres, as well as in other blood centres around the world.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Donantes de Sangre , Seguridad de la Sangre , Selección de Donante/métodos , Serodiagnóstico de la Sífilis , Sífilis/diagnóstico , Treponema pallidum/inmunología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Brasil/epidemiología , Estudios Transversales , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Inmunoensayo , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa , Prevalencia , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estudios Seroepidemiológicos , Sífilis/sangre , Sífilis/epidemiología , Sífilis/transmisión , Serodiagnóstico de la Sífilis/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA