Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Anal Biochem ; 692: 115579, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38797485

RESUMEN

Synthetic opioids like Tramadol are used to treat mild to moderate pain. Its ability to relieve pain is about a tenth that of morphine. Furthermore, Tramadol shares similar effects on serotonin and norepinephrine to several antidepressants known as serotonin-norepinephrine reuptake inhibitors (SNRIs), such as venlafaxine and duloxetine. The present review paper discusses the recent developments in analytical methods for identifying drugs in pharmaceutical preparations and toxicological materials, such as blood, saliva, urine, and hair. In recent years, a wide variety of analytical instruments, including capillary electrophoresis, NMR, UV-visible spectroscopy, HPTLC, HPLC, LC-MS, GC, GC-MS, and electrochemical sensors, have been used for drug identification in pharmaceutical preparations and toxicological samples. The primary quantification techniques currently employed for its quantification in various matrices are highlighted in this research.


Asunto(s)
Analgésicos Opioides , Tramadol , Tramadol/análisis , Tramadol/orina , Analgésicos Opioides/análisis , Analgésicos Opioides/orina , Humanos
2.
Luminescence ; 39(5): e4774, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38757441

RESUMEN

One of the most common features of many different clinical conditions is pain; hence, there is a crucial need for eliminating or reducing it to a tolerable level to retrieve physical, psychological and social functioning. A first derivative synchronous spectrofluorimetry technique is proposed for the simultaneous determination of celecoxib and tramadol HCl, a recent coformulation authorized for treating acute pain in adults. The method includes using synchronous spectrofluorimetry at ∆λ = 80 nm where tramadol HCl was determined using first derivative technique at λ = 230.2 nm, while celecoxib was determined at λ = 288.24 nm. The proposed method was successfully applied to their co-formulated dosage forms in addition to spiked human plasma and validated in agreement with the guidelines of the International Council for Harmonization of Technical Requirements for Pharmaceuticals for Human Use (ICH). The linear ranges were found to be 0.50-5.0 and 0.15-0.50, the limits of detection to be 0.088 and 0.011 and the limits of quantification to be 0.266 and 0.032 µg/ml for celecoxib and tramadol, respectively. Statistical analysis revealed no significant difference when compared with previously reported methods as evidenced by the values of the variance ratio F-test and Student t-test. The proposed method was successfully applied to commercial dosage forms and spiked human samples. Moreover, the greenness of the proposed method was investigated based on the analytical eco-scale approach, with the results showing an excellent green scale with a score of 95.


Asunto(s)
Celecoxib , Espectrometría de Fluorescencia , Tramadol , Celecoxib/sangre , Celecoxib/análisis , Tramadol/sangre , Tramadol/análisis , Humanos , Espectrometría de Fluorescencia/métodos , Comprimidos
3.
Ceska Slov Farm ; 71(2): 67-77, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35728971

RESUMEN

The aim of the present study is the development and validation of a simple method based on capillary zone electrophoresis coupled with UV detection for simultaneous determination of tramadol and paracetamol in pharmaceutical and biological samples. The background electrolyte was composed of 50 mM ammonium carbonate, which is a type of a non-conventional electrolyte system. The developed method was characterized by suitable validation parameters, such as linearity (coefficient of determination r2 0,995), selectivity or the limit of detection at the level of 0.25 - 0.5 μg/ml. Acceptable values of accuracy and precision were obtained, which were in good agreement with the recommended validation guidelines for analysis of pharmaceutical and biological samples. Detection was performed at a wavelength of 200 nm. The developed method was successfully applied to determine tramadol and paracetamol in various dosage forms and in urine biological samples. Achieved results indicate a potential of the method to be integrated in the common quality control processes of drugs and/or in bioanalysis.


Asunto(s)
Tramadol , Acetaminofén , Electroforesis Capilar/métodos , Preparaciones Farmacéuticas , Tramadol/análisis
4.
Mikrochim Acta ; 187(2): 126, 2020 01 14.
Artículo en Inglés | MEDLINE | ID: mdl-31938885

RESUMEN

An electrochemical sensing platform based upon screen-printing electrodes (SPEs) modified with nanostructured lanthanide metal oxides facilitate the detection of the widely misused drugs acetaminophen (ACP) and tramadol (TRA). Among the metal oxides examined, Yb2O3 nanoplates (NPs) were found to give rise to an optimal electrochemical response. The electroanalysis of ACP and TRA individually, and within mixtures, was performed using cyclic and differential pulse voltammetry. The ACP and TRA exhibited non-overlapping voltammetric signals at voltages of +0.30 and + 0.67 V (vs. Ag/AgCl; pH 9) using Yb2O3-SPEs. Pharmaceutical dosage forms and spiked human fluids were analyzed in wide linear concentration ranges of 0.25-654 and 0.50-115 µmol.L-1 with limits of detection (LOD) of 55 and 87 nmol.L-1 for ACP and TRA, respectively. The Yb2O3-SPEs offer a sensitive and chemically stable enzyme-free electrochemical platform for ACP and TRA assay. Graphical abstractSchematic presentation of one-shot electrochemical analysis of misused drugs, tramadol (TRA) and acetaminophen (ACP) by utilizing ytterbium oxide nanoplates modified screen-printed electrodes (Yb2O3-SPEs). The Yb2O3-SPEs showed interesting responses for ACP and TRA within pharmaceutical formulations and human fluids.


Asunto(s)
Acetaminofén/análisis , Analgésicos/análisis , Nanoestructuras/química , Óxidos/química , Tramadol/análisis , Iterbio/química , Acetaminofén/sangre , Acetaminofén/orina , Analgésicos/sangre , Analgésicos/orina , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Electrodos , Humanos , Límite de Detección , Reproducibilidad de los Resultados , Tramadol/sangre , Tramadol/orina
5.
Alcohol Alcohol ; 54(4): 435-438, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31162528

RESUMEN

AIMS: To search for pharmaceutical additives in illicit alcoholic beverages referred to the laboratory of Legal Medicine Organization in Iran in 2017. METHODS: Hundred beverages were sampled. Ethanol content was determined by gas chromatography with flame ionization detection (GC-FID) and then a liquid-liquid extraction combined with reversed-phase high performance liquid chromatography equipped with a photodiode array detector (PAD) was employed for the qualitative analysis. The analysis was confirmed using gas chromatography coupled with mass spectroscopy (GC/MS). RESULTS: In 15% either one or more of the following were detected: tramadol, methadone, diazepam, oxazepam, flurazepam and alprazolam. Tramadol was found with highest frequency. CONCLUSIONS: The wide availability of addictive pharmaceutical is leading to fortification of alcoholic beverages on some countries. The addition of such depressant additives should be better known because of the potentially fatal consequences of the combination with ethanol, as well as the potential for adverse effects on behavior.


Asunto(s)
Bebidas Alcohólicas/análisis , Analgésicos Opioides/análisis , Benzodiazepinas/análisis , Metadona/análisis , Tramadol/análisis , Bebidas Alcohólicas/efectos adversos , Analgésicos Opioides/efectos adversos , Benzodiazepinas/efectos adversos , Cromatografía Líquida de Alta Presión/métodos , Estudios Transversales , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Irán , Metadona/efectos adversos , Distribución Aleatoria , Tramadol/efectos adversos
6.
Biomed Chromatogr ; 33(9): e4572, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31062369

RESUMEN

A simple method, air-assisted dispersive micro-solid-phase extraction-based supramolecular solvent was developed for the preconcentration of tramadol in biological samples prior to gas chromatography-flame ionization detection. A new type of carrier liquid, supramolecular solvent based on a mixture of 1-dodecanol and tetrahydrofuran was combined with layered double hydroxide coated on a magnetic nanoparticle (Fe3 O4 @SiO2 @Cu-Fe-LDH). The supramolecular solvent was injected into the solution containing Fe3 O4 @SiO2 @Cu-Fe-LDH in order to provide high stability and dispersion of the sorbent without any stabilizer agent. Air assisted was applied to enhance the dispersion of the sorbent and solvent. A number of analytical techniques such as Fourier transform-infrared spectrometry, field emission scanning electron microscope, energy-dispersive X-ray spectroscopy and X-ray diffraction measurements were applied to assess the surface chemical characteristics of Fe3 O4 @SiO2 @Cu-Fe-LDH nanoparticles. The effects of important parameters on the extraction recovery were also investigated. Under optimized conditions, the limits of detection and quantification were obtained in the range of 0.9-2.4 and 2.7-7.5 µg L-1 with preconcentration factors in the range of 450-472 in biological samples. This method was used for the determination of tramadol in biological samples (plasma, urine and saliva samples) with good recoveries.


Asunto(s)
Nanopartículas de Magnetita/química , Microextracción en Fase Sólida/métodos , Tramadol/análisis , Humanos , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados , Saliva/química , Solventes/química
7.
Biomed Chromatogr ; 33(6): e4486, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30644574

RESUMEN

Counterfeiting of pharmaceuticals has become a serious problem all over the world, particularly in developing countries. In the present work, a highly sensitive LC-MS/MS method was developed for simultaneous determination of tramadol hydrochloride in the presence of some suspected mislabeled drugs such as alprazolam, diazepam, chlorpheniramine maleate, diphenylhydramine and paracetamol. The prepared samples were analyzed on an API 4000 mass spectrometer using an Eclipse C18 column (3.5 µm, 4.6 × 100 mm). The mobile phase consisting of 0.01% formic acid, acetonitrile and methanol (60:20:20 v/v/v) was pumped with an isocratic elution at a flow rate of 0.7 mL min-1 . The detection was achieved on a triple quadruple tandem mass spectrometer in multiple reaction monitoring mode. The proposed method was successfully validated according to International Conference on Harmonization guidelines with respect to accuracy, precision, linearity, limit of detection and limit of quantitation. The calibration linear range for tramadol hydrochloride, alprazolam, diazepam, chlorpheniramine maleate, diphenylhydramine and paracetamol was 5-500 ng mL-1 . The results revealed that the applied method is promising for the differentiation of genuine tramadol tablets from counterfeit ones without prior separation.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Medicamentos Falsificados/análisis , Espectrometría de Masas en Tándem/métodos , Tramadol/análisis , Medicamentos Falsificados/química , Límite de Detección , Modelos Lineales , Reproducibilidad de los Resultados , Comprimidos , Tramadol/química , Tramadol/normas
8.
Molecules ; 24(4)2019 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-30769936

RESUMEN

In recent years, many studies have highlighted the consistent finding of tramadol (TRA) in the effluents from wastewater treatment plants (WTPs) and also in some rivers and lakes in both Europe and North America, suggesting that TRA is removed by no more than 36% by specific disinfection treatments. The extensive use of this drug has led to environmental pollution of both water and soil, up to its detection in growing plants. In order to expand the knowledge about TRA toxicity as well as the nature of its disinfection by-products (DBPs), a simulation of the waste treatment chlorination step has been reported herein. In particular, we found seven new by-products, that together with TRA, have been assayed on different living organisms (Aliivibrio fischeri, Raphidocelis subcapitata and Daphnia magna), to test their acute and chronic toxicity. The results reported that TRA may be classified as a harmful compound to some aquatic organisms whereas its chlorinated product mixture showed no effects on any of the organisms tested. All data suggest however that TRA chlorination treatment produces a variety of DBPs which can be more harmful than TRA and a risk for the aquatic environment and human health.


Asunto(s)
Desinfección , Ácido Hipocloroso/análisis , Ácido Hipocloroso/toxicidad , Tramadol/análisis , Tramadol/toxicidad , Desinfección/métodos , Ácido Hipocloroso/química , Estructura Molecular , Análisis Espectral , Pruebas de Toxicidad , Tramadol/química
9.
Electrophoresis ; 38(15): 1860-1868, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28387965

RESUMEN

Capillary electrophoresis (CE) is an extremely effective technique in many kinds of separations, including separation of enantiomers. Some additional techniques may be necessary to determine the enantiomer migration order (EMO) and also the mechanism involved in chiral recognition. This paper reports the development and optimization of a CE method for enantioseparation of racemic mixture of both R- and S-stereoisomers of tramadol (TRM) with a computational contribution for the EMO determination and the responsible mechanisms for chiral distinction. Parameters such as composition and concentration of background electrolyte (BGE) and type and concentration of cyclodextrins (CD) were evaluated. For calculations, a sequential methodology was used, resorting to semiempirical Parametric Model 3 (PM3) followed by calculations accomplished using density functional theory. The best results were obtained with sulfated-ß-CD (s-ß-CD) and carboxymethyl-ß-cyclodextrin (cm-ß-CD) as chiral selector. Calculations show that the inclusion of TRM is not a probable process due to the shape of the TRM molecule and the size CDs cavities. Therefore, the chiral recognition process occurs by the formation of association complexes between modified ß-CD and groups of TRM molecules. The structural analysis of the fragments of complexes at a pH of 10 and a thermodynamic analysis of the complexes' formation process allows determining the EMO. Comparing results obtained experimentally and computationally, it seems that the developed method is adequate for separation of TRM enantiomers and the computational methodology is also adequate to get a sense of the system at a molecular level.


Asunto(s)
Electroforesis Capilar/métodos , beta-Ciclodextrinas/química , Citratos/química , Electroforesis Capilar/instrumentación , Concentración de Iones de Hidrógeno , Modelos Moleculares , Estereoisomerismo , Termodinámica , Tramadol/análisis , Tramadol/química , Tramadol/aislamiento & purificación
10.
J Sep Sci ; 40(8): 1815-1823, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28217928

RESUMEN

Paracetamol is an active ingredient commonly found in pharmaceutical formulations in combination with one of the following compounds: codeine, orphenadrine, promethazine, scopolamine, and tramadol. In this work, we propose a unique analytical method for determination of these active ingredients in pharmaceutical samples. The method is based on capillary electrophoresis with capacitively coupled contactless conductivity detection. The separation was achieved on a fused silica capillary (50 cm total length, 40 cm effective length, and 50 µm id) using an optimized background electrolyte composed of 20 mmol/L ß-alanine/4 mmol/L sodium chloride/4 µmol/L sodium hydroxide (pH 9.6). Each sample can be analyzed in a single run (≤2 min) and the limits of detection were 2.5, 0.62, 0.63, 2.5, 15, and 1.6 µmol/L for scopolamine, tramadol, orphenadrine, promethazine, codeine, and paracetamol, respectively. Recovery values for spiked samples were between 94 and 104%.


Asunto(s)
Acetaminofén/análisis , Electroforesis Capilar , Codeína/análisis , Composición de Medicamentos , Orfenadrina/análisis , Prometazina/análisis , Escopolamina/análisis , Tramadol/análisis
11.
Am J Forensic Med Pathol ; 38(4): 345-348, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28767538

RESUMEN

Since tramadol was marketed, it has been widely prescribed as a pain killer because of its relatively safe profile among opioids.Nevertheless, intoxication can occur: overdose can lead to fatal outcomes mostly in association with other drugs, via the potential interaction with serotonergic antidepressant medications, as well as the potential for increased central nervous system (CNS) depression.Fatal outcomes only attributable to tramadol are a rare entity. In this case report, 2 fatal cases are described due to tramadol stand-alone intoxication with peculiar characteristics.In case 1, gas chromatography - mass spectrometry analysis detected tramadol in all specimens (32 µg/mL in the heart blood, 23.9 µg/mL in the femoral blood, 3.3 µg/mL in the bile, and 1.4 µg/mL in the urine). No other CNS depressants were detected by toxicological analysis.In case 2, gas chromatography - mass spectrometry analysis detected tramadol in all specimens (7.5 µg/mL in the heart blood, 5.8 µg/mL in the femoral blood, and 18 µg/mL in the urine). No other CNS depressants were detected by toxicological analysis.Review of the literature was performed to clarify the actual knowledge on this topic.


Asunto(s)
Analgésicos Opioides/envenenamiento , Tramadol/envenenamiento , Adolescente , Analgésicos Opioides/análisis , Analgésicos Opioides/farmacocinética , Bilis/química , Sobredosis de Droga , Cromatografía de Gases y Espectrometría de Masas , Humanos , Masculino , Persona de Mediana Edad , Tramadol/análisis , Tramadol/farmacocinética
12.
Angew Chem Int Ed Engl ; 55(1): 240-3, 2016 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-26473295

RESUMEN

The presence of tramadol in roots of Sarcocephalus latifolius trees in Northern Cameroon was recently attributed to point contamination with the synthetic compound. The synthetic origin of tramadol in the environment has now been unambiguously confirmed. Tramadol samples isolated from tramadol pills bought at a street market in downtown Maroua and highly contaminated soil at Houdouvou were analyzed by high-precision (14)C measurements by accelerator mass spectrometry ((14)C AMS): Tramadol from the pills did not contain any radiocarbon, thus indicating that it had been synthesized from (14)C-free petroleum-derived precursors. Crucially, tramadol isolated from the soil was also radiocarbon-free. As all biosynthetic plant compounds must contain radiocarbon levels close to that of the contemporary environment, these results thus confirm that tramadol isolated from the soil cannot be plant-derived. Analyses of S. latifolius seeds, in vitro grown plants, plants from different origins, and stable-isotope labeling experiments further confirmed that synthetic tramadol contaminates the environment.


Asunto(s)
Contaminantes Ambientales/análisis , Contaminantes Ambientales/síntesis química , Tramadol/análisis , Tramadol/síntesis química , Contaminantes Ambientales/química , Ghana , Raíces de Plantas/química , Rubiaceae/química , Suelo/química , Tramadol/química
13.
Electrophoresis ; 36(2): 305-11, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25262990

RESUMEN

Introducing a new class of chiral selectors is an interesting work and this issue is still one of the hot topics in separation science and chirality. In this study, for the first time, sulfated maltodextrin (MD) was synthesized as a new anionic chiral selector and then it was successfully applied for the enantioseparation of five basic drugs (amlodipine, hydroxyzine, fluoxetine, tolterodine, and tramadol) as model chiral compounds using CE. This chiral selector has two recognition sites: a helical structure and a sulfated group which contribute to three corresponding driving forces; inclusion complexation, electrostatic interaction, and hydrogen binding. Under the optimized condition (buffer solution: 50 mM phosphate (pH 3.0) and 2% w/v sulfated MD; applied voltage: 18 kV; temperature: 20°C), baseline enantioseparation was observed for all mentioned chiral drugs. When instead of sulfated MD neutral MD was used under the same condition, no enantioseparation was observed which means the resolution power of sulfated MD is higher than neutral MD due to the electrostatic interaction between sulfated groups and protonated chiral drugs. Also, the countercurrent mobility of negatively charged MD (sulfated MD) allows more interactions between the chiral selector and chiral drugs and this in turn results in a successful resolution for the enantiomers. Furthermore, a higher concentration of neutral MD (approximately five times) is necessary to achieve the equivalent resolution compared with the negatively charged MD.


Asunto(s)
Electroforesis Capilar/métodos , Preparaciones Farmacéuticas/análisis , Preparaciones Farmacéuticas/química , Polisacáridos/química , Amlodipino/análisis , Aniones , Compuestos de Bencidrilo/análisis , Tampones (Química) , Cresoles/análisis , Electroforesis Capilar/instrumentación , Fluoxetina/análisis , Concentración de Iones de Hidrógeno , Hidroxizina/análisis , Fenilpropanolamina/análisis , Fosfatos , Espectroscopía Infrarroja por Transformada de Fourier , Estereoisomerismo , Sulfatos/química , Temperatura , Tartrato de Tolterodina , Tramadol/análisis
14.
Br J Sports Med ; 49(9): 614-22, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25878079

RESUMEN

BACKGROUND: The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. AIM: To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. METHODS: All qualified players from the 32 teams participating in the World Cup were tested out-of-competition. During the World Cup, 2-8 players per match were tested. Over 1000 samples were collected in total and analysed in the WADA accredited Laboratory of Lausanne. RESULTS: The quality of the analyses was at the required level as described in the WADA technical documents. The urinary steroid profiles of the players were stable and consistent with previously published papers on football players. During the competition, amphetamine was detected in a sample collected on a player who had a therapeutic use exemption for attention deficit hyperactivity disorder. The blood passport data showed no significant difference in haemoglobin values between out-of-competition and postmatch samples. CONCLUSIONS: Logistical issues linked to biological samples collection, and the overseas shipment during the World Cup did not impair the quality of the analyses, especially when used as the biological passport of football players.


Asunto(s)
Doping en los Deportes/prevención & control , Fútbol/fisiología , Anfetamina/análisis , Androstenodiona/análogos & derivados , Androstenodiona/análisis , Análisis Químico de la Sangre/métodos , Brasil , Clenbuterol/análisis , Glucocorticoides/análisis , Humanos , Manejo de Especímenes/métodos , Esteroides/análisis , Detección de Abuso de Sustancias/métodos , Tramadol/análisis , Urinálisis/métodos
15.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124532, 2024 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-38820815

RESUMEN

Letrozole is an anticancer medication prescribed for the management of estrogen receptor-positive breast cancer in postmenopausal women. Chronic pain is prevalent in patients receiving chemotherapy, leading to the use of adjuvant analgesics such as tramadol. This work introduces the first analytical approach for the concurrent quantification of letrozole and tramadol, two co-administered drugs, employing a rapid, highly sensitive, eco-friendly, and cost-effective first derivative synchronous spectrofluorimetric technique. The fluorescence of tramadol and letrozole was measured at wavelengths of 235.9 nm and 241.9 nm, respectively using a wavelength difference (Δλ) of 60.0 nm. The developed approach demonstrated exceptional linearity (r ˃ 0.999) within the specified concentration ranges for tramadol (10.0-1200.0 ng/mL) and letrozole (1.0-140.0 ng/mL). The results demonstrated that the proposed technique exhibits a high level of sensitivity, with detection limits of 0.569 and 0.143 ng/mL for tramadol and letrozole, respectively, indicating the good bioanalytical applicability. The within-run precisions, both intra-day and inter-day, for both analytes, were less than 0.71 % RSD. The developed approach was effectively applied to simultaneously estimate the mentioned drugs in their tablets and human plasma samples, achieving high percentage recoveries and low % RSD values. In order to assess the environmental sustainability of the developed approach, Analytical GREEnnessNNESS (AGREE) and the Green Analytical Procedure Index (GAPI) metric tools were employed. Both tools revealed that the developed approach is excellent green, suggesting its usage as an environmentally-friendly alternative for the routine assayof the investigated pharmaceuticals. The developed approach was validated according to the ICHQ2 (R1) requirements.


Asunto(s)
Neoplasias de la Mama , Letrozol , Límite de Detección , Espectrometría de Fluorescencia , Tramadol , Letrozol/sangre , Letrozol/análisis , Letrozol/administración & dosificación , Tramadol/sangre , Tramadol/análisis , Humanos , Espectrometría de Fluorescencia/métodos , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/sangre , Femenino , Antineoplásicos/sangre , Antineoplásicos/análisis , Reproducibilidad de los Resultados , Comprimidos
16.
J Sep Sci ; 36(23): 3783-90, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24115535

RESUMEN

In this work, a novel procedure based on surfactant-assisted directly suspended droplet microextraction for the determination of tramadol prior to GC with flame ionization detection is proposed. In this technique, a free microdroplet of solvent is transferred to the surface of an immiscible aqueous sample containing Triton X-100 and tramadol while being agitated by a stirring bar placed on the bottom of the sample vial. After the predetermined time, the microdroplet of solvent is withdrawn by a syringe and analyzed. The effective parameters such as the type of organic solvent, extraction time, microdroplet volume, salt content of the donor phase, stirring speed, the source phase pH, concentration of Triton X-100, and extraction temperature were optimized. For this purpose, a multivariate strategy was applied based on an experimental design in order to screen and optimize the significant factors. This method requires minimal sample preparation, analysis time, solvent consumption, and represents significant advantages over customary analytical methods. The linearity ranged from 10 to 2000 µg/L with RSDs (n = 5) of 7.3-10. Preconcentration factors and the LODs were 391-466 and 2.5-6.5 µg/L, respectively. Finally, this method was applied to the analysis of biological samples and satisfactory results were obtained.


Asunto(s)
Química Clínica/métodos , Cromatografía de Gases , Microextracción en Fase Líquida , Tensoactivos/química , Tramadol/análisis , Humanos , Análisis Multivariante , Tramadol/sangre , Tramadol/aislamiento & purificación , Tramadol/orina , Agua/química
17.
Biomed Chromatogr ; 27(8): 1003-11, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23519701

RESUMEN

Over recent years, hair has become the ideal matrix for retrospective investigation of chronic abuse, including for tramadol. However, in order to exclude the possibility of external contamination, it is also important to quantify simultaneously its main metabolite, O-desmethyltramadol (M1), which presence in hair reflects systemic exposure. In the present study a methodology aimed at the simultaneous quantification of tramadol and M1 in human hair was developed and validated for the first time. After decontamination of hair samples (60 mg), tramadol and M1 were extracted with methanol in an ultrasonic bath (~5 h). Purification was performed by solid-phase extraction using mixed-mode extraction cartridges. Subsequently to derivatization, analysis was performed by gas chromatography-electron impact/mass spectrometry (GC-EI/MS). The method proved to be selective. The regression analysis for both analytes was shown to be linear in the range of 0.1-20.0 ng/mg with correlation coefficients of 0.9995 and 0.9997 for tramadol and M1, respectively. The coefficients of variation oscillated between 3.85 and 13.24%. The limits of detection were 0.03 and 0.02 ng/mg, and the lower limits of quantification were 0.08 and 0.06 ng/mg for tramadol and M1, respectively. The proof of applicability was performed in hair samples from six patients undergoing tramadol therapy. All samples were positive for tramadol and M1.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas/métodos , Cabello/química , Tramadol/análogos & derivados , Tramadol/análisis , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Análisis de los Mínimos Cuadrados , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Extracción en Fase Sólida
18.
Am J Forensic Med Pathol ; 34(1): 29-33, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23361077

RESUMEN

In this report, a unique and bizarre case of complicated suicide is presented. The decedent was found dead in the basin of a porta-potty, wearing women's pantyhose, jewelry, and makeup. The initial investigation was suspect for homicide. Although an autoerotic accidental death cannot be excluded, the patient's medical history and autopsy results provided evidence for suicide, including several substances positive in his serum. Tramadol was quantified to be 140 mg/L, approximately 470 times the therapeutic range. Moreover, formaldehyde was also present, presumably absorbed from the contents of the chemical toilet. An exhaustive search could not reveal similar circumstances of suicide in a porta-potty or with the levels of tramadol found in the decedent.


Asunto(s)
Suicidio , Cuartos de Baño , Travestismo , Adulto , Anfetamina/análisis , Analgésicos Opioides/análisis , Analgésicos Opioides/envenenamiento , Asfixia/etiología , Estimulantes del Sistema Nervioso Central/análisis , Desinfectantes/análisis , Desinfectantes/farmacocinética , Sobredosis de Droga , Fiebre/etiología , Toxicología Forense , Formaldehído/análisis , Formaldehído/farmacocinética , Humanos , Masculino , Absorción Cutánea , Tramadol/análisis , Tramadol/envenenamiento
19.
Drug Test Anal ; 15(9): 1022-1026, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37105763

RESUMEN

An 11-month-old boy was found dead. Autopsy findings (cyanosis and polyvisceral congestion) and blood tramadol (TR) concentration of 6240 µg/L were consistent with an acute TR intoxication. In this poisoning situation, owing to the mother's statements (TR addiction leading to daily TR-orange juice mixture preparation accidentally used for the baby bottle preparation by the mother's partner), and the question of possible previous TR administrations to the infant, hair and/or nails (infant, mother, partner, 6-year-old sister) analysis was performed. Hair (2-cm-long hair segments from proximal [S1] to distal [S3]) and nails concentrations (pg/mg; nd: not detected) were as follows: Infant (hair: TR 1420 [S1], 1622 [S2], 2736 [S3]; O-DMT 16-38; N-DMT 34-100 [TR in significant quantities in the hair decontamination bath]-toenails: TR 584; O-DMT 8; N-DMT 15), mother (hair: TR 2340 [S1], 2150 [S2], 2500 [S3]; O-DMT 704-1170; N-DMT 827-1360), mother's partner (fingernails: TR 72; O-DMT nd; N-DMT nd) and sister (hair: TR 261 [S1], 524 [S2]; O-DMT 15 [S1], 16 [S2]; N-DMT 20 [S1], 38 [S2]). Metabolite ratio (infant and sister hair) was comparable to those observed in hair of pharmaceutical industry employees manufacturing tramadol. TR in washing baths, low observed nail concentrations (infant and partner) confirm (i) TR-related mother's addiction and (ii) external contamination issues (TR in sweat of the child at the time of death and in living environment) to explain the infant's keratinized samples results. This case report illustrates the interest of analyzing keratinized matrices of the whole family in such a situation.


Asunto(s)
Tramadol , Masculino , Lactante , Femenino , Niño , Humanos , Tramadol/análisis , Uñas/química , Madres , Cabello/química , Muerte del Lactante
20.
J Environ Monit ; 14(5): 1391-9, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22446514

RESUMEN

The presence of the anesthetic lidocaine (LDC), the analgesic tramadol (TRA), the antidepressant venlafaxine (VEN) and the metabolites O-desmethyltramadol (ODT) and O-desmethylvenlafaxine (ODV) was investigated in wastewater treatment plant (WWTP) effluents, in surface waters and in groundwater. The analytes were detected in all effluent samples and in only 64% of the surface water samples. The mean concentrations of the analytes in effluent samples from WWTPs with wastewater from only households and hospitals were 107 (LDC), 757 (TRA), 122 (ODT), 160 (VEN) and 637 ng L(-1) (ODV), while the mean concentrations in effluents from WWTPs treating additionally wastewater from pharmaceutical industries as indirect dischargers were for some pharmaceuticals clearly higher. WWTP effluents were identified as important sources of the analyzed pharmaceuticals and their metabolites in surface waters. The concentrations of the compounds found in surface waters ranged from

Asunto(s)
Ciclohexanoles/análisis , Agua Subterránea/química , Lidocaína/análisis , Tramadol/análisis , Eliminación de Residuos Líquidos , Contaminantes Químicos del Agua/análisis , Succinato de Desvenlafaxina , Monitoreo del Ambiente , Ríos/química , Tramadol/análogos & derivados , Clorhidrato de Venlafaxina , Contaminación Química del Agua/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA