Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 382
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Br J Clin Pharmacol ; 88(6): 2793-2801, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34951499

RESUMEN

AIMS: Iohexol clearance has been proposed to estimate the glomerular filtration rate (GFR). A population pharmacokinetics (popPK) model was developed from heterogeneous patients. A Bayesian estimator (MAP-BE) based on a limited sampling strategy (LSS) was derived and evaluated in external patients. METHODS: Full pharmacokinetic data (7-12 samples) from 172 patients receiving iohexol for measurement of their GFR (unstable and stable ICU patients, liver failure patients and kidney transplant patients) were split into development (n = 136) and validation (n = 36) datasets. A PopPK model was developed in Monolix and was used to develop MAP-BE based on LSS. Its performance for GFR estimation was evaluated in the validation set. RESULTS: A two-compartment model with first-order elimination best described the data. The final model included the type of patients on volume of distribution (Vd), clearance and intercompartmental constants, serum creatinine on clearance and body weight on Vd. The best LSS included samples at 0.1-1-9 h exhibiting a relative mean prediction error (MPE) (RMSE) = -3.7% (14.3%) and better performance than the Bröchner-Mortensen formula (-3.0%/17%). Split by type of patients, the highest interindividual variability and imprecision was observed in unstable ICU patients (MPE (RMSE) = 3.7% (18.8%)) while the best performances were obtained for renal transplant patients (MPE (RMSE) = 1.0% (5.8%)). All LSS that included samples before 9 hours for the third sample were associated with an increased imprecision. CONCLUSION: A single MAP-BE of iohexol based on a three-sample LSS for four heterogeneous populations was developed and allowed accurate estimation of GFR in kidney transplant patients, slightly biased in stable ICU patients and slightly imprecise in unstable ICU patients.


Asunto(s)
Trasplante de Riñón , Fallo Hepático , Teorema de Bayes , Tasa de Filtración Glomerular , Humanos , Unidades de Cuidados Intensivos , Yohexol/farmacocinética , Trasplante de Riñón/efectos adversos
2.
Eur J Clin Pharmacol ; 78(6): 989-1001, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35275224

RESUMEN

PURPOSE: Estimated glomerular filtration rate (eGFR) equations reflect kidney function imprecisely. We aimed to describe whether iohexol-based GFR or eGFRs predict clearance of cefepime, piperacillin, and tazobactam in pharmacokinetic (PK) models in this population and its clinical significance. METHODS: Hospitalized patients (0.5-25 years) with haemato-oncological disease and infection receiving cefepime or piperacillin/tazobactam were included. PK samples were collected at a steady state concomitantly with samples for iohexol-based GFR. PK models were developed in NONMEM. Weight, postmenstrual age, iohexol-based GFR, different eGFR equations (Schwartz updated, Lund-Malmö revised, CKD-EPI, Bouvet, Schwartz cystatin C-based) were tested as covariates. Probabilities of neurotoxic/therapeutic concentrations were assessed by simulations. RESULTS: Fifteen patients receiving cefepime and 17 piperacillin/tazobactam were included (median (range) age 16.2 (1.9-26.0) and 10.5 (0.8-25.6) years, iohexol-based GFR 102 (68-140) and 116 (74-137) mL/min/1.73 m2, respectively). Two-compartment model provided the best fit for all drugs. Weight was covariate for central and peripheral compartment, clearance and intercompartmental clearance (only tazobactam), and postmenstrual age for clearance (excluding cefepime). Iohexol-based GFR was the best predictor of clearance. The model of cefepime without vs with iohexol-based GFR underestimated the probability of neurotoxic concentrations (28.3-28.6% vs 52.1-69.3%) and overestimated the probability of therapeutic concentrations (> 90% vs 81.9-87.1%) in the case of iohexol-based GFR 70-80 and 130-140 mL/min/1.73 m2, respectively. CONCLUSION: Iohexol-based GFR can predict better than eGFRs the clearance of cefepime, piperacillin, and tazobactam in children and young adults with haemato-oncological disease and infection, warranting further investigation as an indicator of renal function to improve targeting of therapeutic window. TRIAL REGISTRATION NUMBER AND DATE OF REGISTRATION: EudraCT 2015-000,631-32, EudraCT 2016-003,374-40 (24.10.2016).


Asunto(s)
Yohexol , Piperacilina , Adolescente , Cefepima , Niño , Creatinina , Tasa de Filtración Glomerular , Humanos , Yohexol/farmacocinética , Pruebas de Función Renal , Tazobactam , Adulto Joven
3.
J Am Soc Nephrol ; 32(2): 459-468, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33239392

RESUMEN

BACKGROUND: Although proximal tubular secretion is the primary mechanism of kidney drug elimination, current kidney drug dosing strategies are on the basis of eGFR. METHODS: In a dedicated pharmacokinetic study to compare GFR with tubular secretory clearance for predicting kidney drug elimination, we evaluated stable outpatients with eGFRs ranging from 21 to 140 ml/min per 1.73 m2. After administering single doses of furosemide and famciclovir (metabolized to penciclovir), we calculated their kidney clearances on the basis of sequential plasma and timed urine measurements. Concomitantly, we quantified eight endogenous secretory solutes in plasma and urine using liquid chromatography-tandem mass spectrometry and measured GFR by iohexol clearance (iGFR). We computed a summary secretion score as the scaled average of the secretory solute clearances. RESULTS: Median iGFR of the 54 participants was 73 ml/min per 1.73 m2. The kidney furosemide clearance correlated with iGFR (r=0.84) and the summary secretion score (r=0.86). The mean proportionate error (MPE) between iGFR-predicted and measured furosemide clearance was 30.0%. The lowest MPE was observed for the summary secretion score (24.1%); MPEs for individual secretory solutes ranged from 27.3% to 48.0%. These predictive errors were statistically indistinguishable. Penciclovir kidney clearance was correlated with iGFR (r=0.83) and with the summary secretion score (r=0.91), with similar predictive accuracy of iGFR and secretory clearances. Combining iGFR with the summary secretion score yielded only modest improvements in the prediction of the kidney clearance of furosemide and penciclovir. CONCLUSIONS: Secretory solute clearance measurements can predict kidney drug clearances. However, tight linkage between GFR and proximal tubular secretory clearance in stable outpatients provides some reassurance that GFR, even when estimated, is a useful surrogate for predicting secretory drug clearances in such patients.


Asunto(s)
Famciclovir/farmacocinética , Furosemida/farmacocinética , Tasa de Filtración Glomerular/fisiología , Glomérulos Renales/metabolismo , Túbulos Renales/metabolismo , Eliminación Renal/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Antivirales/farmacocinética , Medios de Contraste/farmacocinética , Diuréticos/farmacocinética , Femenino , Humanos , Yohexol/farmacocinética , Masculino , Persona de Mediana Edad
4.
AJR Am J Roentgenol ; 217(6): 1365-1366, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34161132

RESUMEN

Among 109 iohexol-based water-soluble contrast (WSC) challenges performed for suspected small-bowel obstruction, 105 were technically adequate. Among technically adequate studies, colonic contrast (i.e., successful challenge) was seen on 66 abdominal radiographs obtained 8 hours after WSC challenge and 86 abdominal radiographs obtained 24 hours after WSC challenge. Fourteen patients underwent operative management, and 91 underwent nonoperative management (NOM). Successful challenge had a sensitivity of 91.2%, specificity of 78.5%, PPV of 96.5%, NPV of 57.8%, and odds ratio of 38.0 (95% CI, 8.7-165.2) for NOM. Three of 86 patients with successful challenge underwent operative management.


Asunto(s)
Medios de Contraste/farmacocinética , Obstrucción Intestinal/diagnóstico por imagen , Yohexol/farmacocinética , Intensificación de Imagen Radiográfica/métodos , Radiografía/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Intestino Delgado/diagnóstico por imagen , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Agua
5.
BMC Nephrol ; 22(1): 166, 2021 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-33952185

RESUMEN

BACKGROUND: Measuring glomerular filtration rate (GFR) using iohexol plasma clearance has been proposed as the preferred way for GFR determination. The extended multiple-sample protocol is based on fitting the full concentration-time decay-curve, and from the obtained fit-parameters, the area under the curve (AUC) and GFR (the injected dose divided by the AUC) were calculated. The goal of the current study is to evaluate the impact of different fitting procedures on the precision of GFR-results obtained from the full concentration-time curve, and compare these results with those obtained with simplified multiple-samples and single-sample protocols. METHODS: The concentration-time curves of 8 samples at times 30, 60, 90, 120, 150, 180, 240 and 300 min after bolus injection of iohexol of 570 adults, aged 70+, from the Berlin Initiative Study (BIS), were analysed. The fit-parameters for the two-compartment model (double-exponential decay curve), and from these, the AUC and GFR were obtained with 8 different fitting procedures. RESULTS: The two-compartmental non-linear least squares fitting procedure showed the best accuracy (541 out of 570 reported GFR-results were within 5% of the majority of the 8 fitting methods). The two-compartmental slope-intercept fitting procedure was not always applicable and the non-compartmental fitting procedures did not always allow to calculate the GFR. All correction formulas for the simplified late multiple-samples methods showed acceptable accuracy and precision with a preference for Ng's correction formula (Lin's CCC = 0.992, bias = 0.5 ± 2.5). Jacobsson's iterative method was the best one-sample method, with Lin's CCC = 0.983 and bias = - 0.6 ± 3.4. CONCLUSION: The fitting procedure has an important impact on the precision of the calculated AUC and GFR. The simplified late-sample protocols and one-sample methods did not suffer from fitting problems and showed acceptable equivalence when compared to the full compartment GFR-results. TRIAL REGISTRATION: The "Berlin Initiative Study" is officially registered with the German Register for Clinical Studies ("Deutschen Register Klinischer Studien"(DRKS)) under registration number DRKS00017058 , since April 12, 2019, and it is also visible on the WHO clinical trials registry platform (within the next 4 weeks after the registration date).


Asunto(s)
Medios de Contraste/farmacocinética , Tasa de Filtración Glomerular , Yohexol/farmacocinética , Área Bajo la Curva , Humanos , Riñón/metabolismo , Tasa de Depuración Metabólica
6.
BMC Nephrol ; 22(1): 178, 2021 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-33992075

RESUMEN

BACKGROUND: Autosomal dominant polycystic kidney disease (ADPKD) is the most common hereditary kidney disorder that leads to end stage renal disease (ESRD). Cyst expansion in ADPKD is strongly associated with the decline in renal function. However, the correlation between total kidney volume (TKV) and glomerular filtration rate (GFR) at an early stage has not been well demonstrated. There is growing evidence that utilization of estimated GFR (eGFR) may induce misleading information in a population with near normal renal function. Therefore, a more accurate method is essential. METHODS: A prospective cohort of ADPKD patients was conducted with clinical data and laboratory collection. Measured GFR (mGFR) was assessed by iohexol plasma clearance method using ultra performance liquid chromatography. eGFR was calculated using the CKD-EPI equation. Kidney volumes were evaluated using MRI imaging protocol. RESULTS: Thirty two patients completed the study. The mean age was 56 years old. The mean initial mGFR was 83.8 mL/min/1.73m2. The mean change in mGFR per year was -2.99 mL/min/1.73m2/year. The mean initial height-adjusted TKV (htTKV) was 681.0 mL/m. The mean percentage change in htTKV per year (%ΔhtTKV/y) was 4.77 %/year. mGFR had a better association with clinical parameters than eGFR. Initial mGFR was significantly and inversely correlated with initial htTKV and age. The percentage change in mGFR per year was significantly and inversely correlated with the %ΔhtTKV/y and 24-hr urine albumin. The %ΔhtTKV/y was significantly correlated with initial htTKV. CONCLUSIONS: Our studies demonstrated that mGFR using iohexol is a more reliable and accurate method than eGFR for evaluating GFR changes in the early stages of ADPKD patients. There is a strong inverse correlation between kidney volume and mGFR in an Asian ADPKD population. The initial htTKV is a good predictor of kidney volume progression. The %ΔhtTKV/y is a good early surrogate marker for the decline in renal function. 24-hr urine albumin is also a good indicator for renal progression.


Asunto(s)
Tasa de Filtración Glomerular , Yohexol/farmacocinética , Riñón/anatomía & histología , Riñón Poliquístico Autosómico Dominante/etnología , Biomarcadores , Femenino , Humanos , Riñón/fisiopatología , Masculino , Persona de Mediana Edad , Riñón Poliquístico Autosómico Dominante/patología , Riñón Poliquístico Autosómico Dominante/fisiopatología , Estudios Prospectivos , Tailandia
7.
J Am Soc Nephrol ; 31(7): 1602-1615, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32499396

RESUMEN

BACKGROUND: Population mean GFR is lower in older age, but it is unknown whether healthy aging is associated with preserved rather than lower GFR in some individuals. METHODS: We investigated the cross-sectional association between measured GFR, age, and health in persons aged 50-97 years in the general population through a meta-analysis of iohexol clearance measurements in three large European population-based cohorts. We defined a healthy person as having no major chronic disease or risk factors for CKD and all others as unhealthy. We used a generalized additive model to study GFR distribution by age according to health status. RESULTS: There were 935 (22%) GFR measurements in persons who were healthy and 3274 (78%) in persons who were unhealthy. The mean GFR was lower in older age by -0.72 ml/min per 1.73 m2 per year (95% confidence interval [95% CI], -0.96 to -0.48) for men who were healthy versus -1.03 ml/min per 1.73 m2 per year (95% CI, -1.25 to -0.80) for men who were unhealthy, and by -0.92 ml/min per 1.73 m2 per year (95% CI, -1.14 to -0.70) for women who were healthy versus -1.22 ml/min per 1.73 m2 per year (95% CI, -1.43 to -1.02) for women who were unhealthy. For healthy and unhealthy people of both sexes, both the 97.5th and 2.5th GFR percentiles exhibited a negative linear association with age. CONCLUSIONS: Healthy aging is associated with a higher mean GFR compared with unhealthy aging. However, both the mean and 97.5 percentiles of the GFR distribution are lower in older persons who are healthy than in middle-aged persons who are healthy. This suggests that healthy aging is not associated with preserved GFR in old age.


Asunto(s)
Envejecimiento/fisiología , Medios de Contraste/farmacocinética , Tasa de Filtración Glomerular , Estado de Salud , Yohexol/farmacocinética , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Alemania , Humanos , Islandia , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Noruega , Factores Sexuales
8.
Crit Care Med ; 48(12): e1232-e1241, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33044285

RESUMEN

OBJECTIVES: To compare estimated glomerular filtration rate using classical static and kinetic equations with measured glomerular filtration rate assessed by plasma iohexol clearance in a mixed population of critical care patients. PATIENTS: Unselected patients older than 18 and admitted to a general ICU. DESIGN: Interventional prospective single center study. INTERVENTION: Measurement of glomerular filtration rate by the plasma clearance of an IV single dose of iohexol and estimation of glomerular filtration rate with creatinine or cystatin C-based standard and kinetic equations as well as urinary creatinine clearance. MEASUREMENTS AND MAIN RESULTS: Sixty-three patients were included with a median age of 66 years old. The median measured glomerular filtration rate was 51 mL/min/1.73 m (interquartile range, 19-85 mL/min/1.73 m). All used equations displayed significant biases, high errors, and poor accuracy when compared with measured glomerular filtration rate, overestimating renal function. The highest accuracy and lowest error were observed with cystatin C-based chronic kidney disease epidemiology collaboration equations. Both modification of diet in renal disease and Cockcroft-Gault equations displayed the lowest performance. Kinetic models did not improve performances, except in patients with unstable creatinine levels. Creatinine- but not cystatin C-based estimations largely derived over ICU stay, which appeared more related to sarcopenia than fluid balance. Finally, estimated glomerular filtration rate misclassified patients according to classical glomerular filtration rate categories in approximately half of the studied cases. CONCLUSIONS: All known estimated glomerular filtration rate equations displayed high biases and unacceptable errors when compared with measured glomerular filtration rate in a mixed ICU population, with the lowest performance related to creatinine-based equations compared with cystatin C. In the ICU, we advocate for caution when using creatinine based estimated glomerular filtration rate equations. Drifting of serum creatinine levels over time should also be taken into consideration when assessing renal function in the ICU.


Asunto(s)
Tasa de Filtración Glomerular , Unidades de Cuidados Intensivos , Anciano , Creatinina/sangre , Cistatina C/sangre , Femenino , Humanos , Yohexol/análisis , Yohexol/farmacocinética , Riñón/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
9.
AJR Am J Roentgenol ; 214(4): 808-816, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32069083

RESUMEN

OBJECTIVE. The purpose of this study is to determine the degree of the relationship between perfusion CT (PCT) parameters and iodine concentration metrics derived from triple-bolus dual-energy CT (DECT) and to compare the radiation dose delivered. SUBJECTS AND METHODS. This single-center prospective study was conducted from October 2015 to September 2017. Twenty-three consenting adults (15 men and eight women; mean [± SD] age, 56 ± 13 years [range, 25-78 years]) with renal cell carcinomas underwent consecutive PCT and triple-bolus DECT examinations. Triple-bolus DECT consisted of synchronous corticomedullary, nephrographic, and delayed phase scans acquired using a dual-source DECT scanner. Two readers independently analyzed blood flow, blood volume, and permeability, as measured by PCT, and iodine density and iodine ratio, as measured by triple-bolus DECT. Size-specific dose estimates were calculated for both groups. RESULTS. Interreader agreement was good for permeability (intraclass correlation coefficient [ICC] =.812) and blood flow (ICC = 0.849) and excellent for blood volume (ICC = 0.956), iodine density (ICC = 0.961), and iodine ratio (ICC = 0.956). Very strong positive correlations were found between blood volume and iodine density (p < 0.001) and between blood volume and iodine ratio (p < 0.001). Strong positive correlations were found between blood flow and iodine density (p < 0.001) and between blood flow and iodine ratio (p < 0.001). The correlations between permeability and iodine density (p = 0.01) and between permeability and iodine ratio (p = 0.02) were moderate. The mean size-specific dose estimate of triple-bolus DECT was approximately 15 times lower than that of PCT (p < 0.001). CONCLUSION. Quantitative iodine metrics derived from triple-bolus DECT showed significant correlation with CT parameters in renal cell carcinoma, with a significantly lower radiation dose.


Asunto(s)
Carcinoma de Células Renales/diagnóstico por imagen , Medios de Contraste/farmacocinética , Yohexol/farmacocinética , Neoplasias Renales/diagnóstico por imagen , Neovascularización Patológica/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador
10.
Clin Chem Lab Med ; 58(4): 577-587, 2020 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-31926067

RESUMEN

Background Plasma iohexol clearance (CLiohexol) is a reference technique for glomerular filtration rate (GFR) determination. In routine practice, CLiohexol is calculated using one of several formulas, which have never been evaluated in kidney transplant recipients. We aimed to model iohexol pharmacokinetics in this population, evaluate the predictive performance of three simplified formulas and evaluate whether a Bayesian algorithm improves CLiohexol estimation. Methods After administration of iohexol, six blood samples were drawn from 151 patients at various time points. The dataset was split into two groups, one to develop the population pharmacokinetic (POPPK) model (n = 103) and the other (n = 48) to estimate the predictive performances of the various GFR estimation methods. GFR reference values (GFRref) in the validation dataset were obtained by non-compartmental pharmacokinetic (PK) analysis. Predictive performances of each method were evaluated in terms of bias (ME), imprecision (root mean square error [RMSE]) and number of predictions out of the ±10% or 15% error interval around the GFRref. Results A two-compartment model best fitted the data. The Bayesian estimator with samples drawn at 30, 120 and 270 min allowed accurate prediction of GFRref (ME = 0.47%, RMSE = 3.42%), as did the Brøchner-Mortensen (BM) formula (ME = - 0.0425%, RMSE = 3.40%). With both methods, none of the CL estimates were outside the ±15% interval and only 2.4% were outside the ±10% for the BM formula (and none for the Bayesian estimator). In patients with GFR ≤30 mL/min/1.73 m2, the BM formula performed very well, while the Bayesian method could not be evaluated in depth due to too small a number of patients with adequate sampling times. Conclusions GFR can be estimated with acceptable accuracy in kidney transplant patients using the BM formula, but also using a Bayesian algorithm.


Asunto(s)
Tasa de Filtración Glomerular , Yohexol/farmacocinética , Trasplante de Riñón , Adulto , Anciano , Algoritmos , Teorema de Bayes , Femenino , Humanos , Yohexol/administración & dosificación , Yohexol/análisis , Masculino , Persona de Mediana Edad , Insuficiencia Renal Crónica/terapia
11.
J Nanobiotechnology ; 18(1): 110, 2020 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-32762751

RESUMEN

BACKGROUNDS: Due to the unexpected side effects of the iodinated contrast agents, novel contrast agents for X-ray computed tomography (CT) imaging are urgently needed. Nanoparticles made by heavy metal elements are often employed, such as gold and bismuth. These nanoparticles have the advantages of long in vivo circulation time and tumor targeted ability. However, due to the long residence time in vivo, these nanoparticles may bring unexpected toxicity and, the preparation methods of these nanoparticles are complicated and time-consuming. METHODS: In this investigation, a small molecular bismuth chelate using diethylenetriaminepentaacetic acid (DPTA) as the chelating agent was proposed to be an ideal CT contrast agent. RESULTS: The preparation method is easy and cost-effective. Moreover, the bismuth agent show better CT imaging for kidney than iohexol in the aspect of improved CT values. Up to 500 µM, the bismuth agent show negligible toxicity to L02 cells and negligible hemolysis. And, the bismuth agent did not induce detectable morphology changes to the main organs of the mice after intravenously repeated administration at a high dose of 250 mg/kg. The pharmacokinetics of the bismuth agent follows the first-order elimination kinetics and, it has a short half-life time of 0.602 h. The rapid clearance from the body promised its excellent biocompatibility. CONCLUSIONS: This bismuth agent may serve as a potential candidate for developing novel contrast agent for CT imaging in clinical applications.


Asunto(s)
Bismuto , Medios de Contraste , Tomografía Computarizada por Rayos X/métodos , Animales , Bismuto/química , Bismuto/farmacocinética , Bismuto/toxicidad , Medios de Contraste/química , Medios de Contraste/farmacocinética , Medios de Contraste/toxicidad , Yohexol/química , Yohexol/farmacocinética , Riñón/diagnóstico por imagen , Riñón/metabolismo , Nanopartículas del Metal/química , Nanopartículas del Metal/toxicidad , Ratones , Ácido Pentético/química , Ácido Pentético/farmacocinética , Distribución Tisular , Imagen de Cuerpo Entero
12.
BMC Nephrol ; 21(1): 20, 2020 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-31941441

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is a substantial cause of morbidity and mortality worldwide with disproportionate effects in sub-Saharan Africa (SSA). The optimal methods to estimate glomerular filtration rate (GFR) and therefore to determine the presence of CKD in SSA are uncertain. We plan to measure iohexol excretion to accurately determine GFR in Malawi, South Africa and Uganda. We will then assess the performance of existing equations to estimate GFR and determine whether a modified equation can better improve estimation of GFR in sub-Saharan Africa. METHODS: The African Research on Kidney Disease (ARK) study is a three-country study embedded within existing cohorts. We seek to enrol 3000 adults > 18 years based on baseline serum creatinine. Study procedures include questionnaires on socio-demographics and established risk factors for kidney disease along with anthropometry, body composition, blood pressure, blood chemistry and urine microscopy and albuminuria. We will measure GFR (mGFR) by plasma clearance of iohexol at 120, 180 and 240 min. We will compare eGFR determined by established equations with mGFR using Bland-Altman plots. We will use regression methods to estimate GFR and compare the newly derived model with existing equations. DISCUSSION: Through the ARK study, we aim to establish the optimal approach to estimate GFR in SSA. The study has the advantage of drawing participants from three countries, which will increase the applicability of the findings across the region. It is also embedded within established cohorts that have longitudinal information and serial measures that can be used to characterize kidney disease over a period of time. This will help to overcome the limitations of previous research, including small numbers, selected population sub-groups, and lack of data on proteinuria. The ARK collaboration provides an opportunity for close working partnerships across different centres, using standardized protocols and measurements, and shared bio-repositories. We plan to build on the collaboration for this study for future work on kidney disease in sub-Saharan Africa, and welcome additional partners from across the continent.


Asunto(s)
Tasa de Filtración Glomerular , Yohexol/farmacocinética , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/fisiopatología , Adulto , África del Sur del Sahara , Femenino , Humanos , Malaui , Masculino , Selección de Paciente , Garantía de la Calidad de Atención de Salud , Análisis de Regresión , Proyectos de Investigación , Sudáfrica , Uganda
13.
Kidney Int ; 95(5): 1181-1189, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30910379

RESUMEN

Glomerular filtration rate (GFR) is the best index for kidney function; however, the applicability of GFR estimating equations in sub-Saharan African populations remains unclear. In a cross-sectional study of adults living in Kinshasa, Democratic Republic of Congo (n=210) and Abidjan, Ivory Coast (n=284), we evaluated the performance of creatinine and cystatin C-based equations using plasma clearance of iohexol as the reference standard. The race coefficient did not improve the performance of creatinine-based GFR estimates; in fact, both the Modification of Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology (CKD-EPI) equations performed better without the race coefficient in participants with GFR ≥60 mL/min/1.73m2. The CKD-EPI and Full Age Spectrum (FAS) equations were unbiased and had similar precision (SD of 17.9 versus 19 mL/min/1.73 m2) and accuracy within 30% (P30, 86.7% versus 87.4%) in participants with GFR ≥60 mL/min/1.73m2. Both equations performed poorly in the subgroup with measured GFR < 60 mL/min/1.73m2 (n=80), but the FAS equation had smaller bias (-4.8 mL/min/1.73m2 versus -7.7 mL/min/1.73m2 for CKD-EPI) and higher P30 (56.3% versus 31.3% for CKD-EPI). The corresponding equations including cystatin C alone or in combination with creatinine had similar performance. In a sub-Saharan African population, adjustment for race did not improve the performance of GFR estimating equations. The creatinine-based FAS and CKD-EPI equations performed reasonably well and were comparable when GFR was ≥ 60 mL/min/1.73m2. Cystatin C did not improve performance. The FAS equation may be preferable when GFR is < 60 mL/min/1.73m2, but this should be confirmed in larger studies.


Asunto(s)
Creatinina/sangre , Cistatina C/sangre , Tasa de Filtración Glomerular , Modelos Biológicos , Insuficiencia Renal Crónica/diagnóstico , Adulto , Estudios de Cohortes , Côte d'Ivoire , Estudios Transversales , República Democrática del Congo , Femenino , Humanos , Yohexol/administración & dosificación , Yohexol/farmacocinética , Riñón/fisiopatología , Masculino , Tasa de Depuración Metabólica , Persona de Mediana Edad , Estándares de Referencia , Insuficiencia Renal Crónica/sangre , Insuficiencia Renal Crónica/fisiopatología
15.
Eur Radiol ; 29(11): 6109-6118, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31016447

RESUMEN

OBJECTIVE: To compare the effect of contrast medium iodine concentration on contrast enhancement, heart rate, and injection pressure when injected at a constant iodine delivery rate in coronary CT angiography (CTA). METHODS: One thousand twenty-four patients scheduled for coronary CTA were prospectively randomized to receive one of four contrast media: iopromide 300 mg I/ml, iohexol 350 mg I/ml, iopromide 370 mg I/ml, or iomeprol 400 mg I/ml. Contrast media were delivered at an equivalent iodine delivery rate of 2.0 g I/s. Intracoronary attenuation was measured and compared (per vessel and per segment). Heart rate before and after contrast media injection was documented. Injection pressure was recorded (n = 403) during contrast medium injection and compared between groups. RESULTS: Intracoronary attenuation values were similar for the different contrast groups. The mean attenuation over all segments ranged between 384 HU for 350 mg I/ml and 395 HU for 400 mg I/ml (p = 0.079). Dose-length product (p = 0.8424), signal-to-noise ratio (all p > 0.05), time to peak (p = 0.324), and changes in heart rate (p = 0.974) were comparable between groups. The peak pressures differed: 197.4 psi for 300 mg I/ml (viscosity 4.6 mPa s), 229.8 psi for 350 mg I/ml (10.4 mPa s), 216.1 psi for 370 mg I/ml (9.5 mPa s), and 243.7 psi for 400 mg I/ml (12.6 mPa s) (p < 0.0001). CONCLUSION: Intravascular attenuation and changes in heart rate are independent of iodine concentration when contrast media are injected at the same iodine delivery rate. Differences in injection pressures are associated with the viscosity of the contrast media. KEY POINTS: • The contrast enhancement in coronary CT angiography is independent of the iodine concentration when contrast media are injected at body temperature (37 °C) with the same iodine delivery rate. • Iodine concentration does not influence the change in heart rate when contrast media are injected at identical iodine delivery rates. • For a fixed iodine delivery rate and contrast temperature, the viscosity of the contrast medium affects the injection pressure.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/farmacocinética , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Yodo/metabolismo , Yohexol/farmacocinética , Medios de Contraste/administración & dosificación , Enfermedad de la Arteria Coronaria/metabolismo , Femenino , Humanos , Inyecciones Intravenosas , Yohexol/administración & dosificación , Yohexol/análogos & derivados , Yopamidol/administración & dosificación , Yopamidol/análogos & derivados , Yopamidol/farmacocinética , Masculino , Persona de Mediana Edad
16.
Pediatr Nephrol ; 34(9): 1565-1574, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31049718

RESUMEN

BACKGROUND: The validity of pediatric estimated glomerular filtration rate equations (eGFRs) in early stages of CKD including hyperfiltration is unknown. The purpose of this study was to develop an eGFR equation for adolescents with obesity and type 2 diabetes (T2D). METHODS: eGFRs were developed from iohexol-derived GFRs (iGFRs) in 26 overweight/obese (BMI > 85th percentile) youth and 100 with T2D from the iCARE (Improving renal Complications in Adolescents with T2D through REsearch) cohort. Twenty percent of the cohort was withheld as a validation dataset. Linear regression analyses were used to develop the best formula based on body size, sex, creatinine, urea, ± cystatin C. Comparable validity of commonly used eGFR equations was assessed. RESULTS: Mean age 15.4 + 2.4 years, BMI Z-score 2.5 + 1.2, 61% female, and mean iGFR 129.0 + 27.7 ml/min/ 1.73 m2. The best adjusted eGFR formula (ml/min/1.73 m2) was 50.7 × BSA0.816 × (height (cm)/creatinine)0.405 × 0.8994 if sex = female | 1 otherwise. It resulted in 53.8% of eGFRs within 10% of measured iGFR and 96.2% within 30%. Bland-Altman 95% limits of agreement in the external dataset were - 37.6 to 45.5 ml/min/1.73m2 (bias = 3.96), and the correlation was 0.62. This equation performed better than all previously published creatinine-based eGFRs. cystatin C did not significantly improve results; however, some other cystatin C formulas also performed well. CONCLUSIONS: The iCARE equation provides a more accurate creatinine-based eGFR in obese youth with and without T2D. Further studies are warranted to evaluate within-subject variability and applicability to lower GFRs and other populations.


Asunto(s)
Diabetes Mellitus Tipo 2/fisiopatología , Tasa de Filtración Glomerular/fisiología , Modelos Biológicos , Obesidad/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Adolescente , Edad de Inicio , Creatinina/sangre , Estudios Transversales , Cistatina C/sangre , Conjuntos de Datos como Asunto , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/complicaciones , Femenino , Humanos , Yohexol/administración & dosificación , Yohexol/farmacocinética , Masculino , Obesidad/sangre , Obesidad/fisiopatología , Eliminación Renal/fisiología , Insuficiencia Renal Crónica/sangre , Insuficiencia Renal Crónica/fisiopatología , Urea/sangre
17.
Regul Toxicol Pharmacol ; 107: 104417, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31276731

RESUMEN

MB-102 was designed for measurement of real-time glomerular filtration rate (GFR). Previously reported in vitro and in vivo nonclinical studies clearly demonstrated negligible toxicity, resulting in FDA clearance for First-in Human, proof of concept clinical studies. The next tier of safety and toxicity studies are reported herein. MB-102 did not demonstrate any phototoxic potential in a BALB/c 3T3 mouse fibroblast study. Co-administration of MB-102 and iohexol resulted in pharmacokinetic parameters virtually identical to the values observed upon individual administration in beagle dogs. A single dose of MB-102 administered either intravenously (18.6 mg/mL) or perivenously (0.25 mL) was well-tolerated in NZ white rabbits, with no adverse inflammation or irritation. MB-102 did not induce micronuclei in polychromatic erythrocytes for rat bone marrow cells treated up to 450 mg/kg/day, the maximum feasible dose. Two separate optical imaging studies demonstrated that MB-102 distributes rapidly and thoroughly throughout the test subjects, followed by rapid clearance from the body without any preferential localization in any particular tissue or organ, with the exception of the bladder, which is totally consistent with a known GFR agent. In addition, two-week repeat intravenous (once-daily) toxicity and toxicokinetic studies were conducted in rats and beagles, with no MB-102- related effects. Thus, for the studies reported herein, there were no toxicological effects of concern for MB-102.


Asunto(s)
Colorantes Fluorescentes/toxicidad , Pirazinas/toxicidad , Animales , Células 3T3 BALB , Medios de Contraste/farmacocinética , Dermatitis Fototóxica , Perros , Interacciones Farmacológicas , Femenino , Colorantes Fluorescentes/farmacocinética , Tasa de Filtración Glomerular , Yohexol/farmacocinética , Masculino , Ratones , Ratones Desnudos , Pruebas de Micronúcleos , Pirazinas/farmacocinética , Conejos , Ratas Sprague-Dawley
18.
J Am Soc Nephrol ; 29(6): 1609-1613, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29748326

RESUMEN

Background Direct quantitative measurement of GFR (mGFR) remains a specialized task primarily performed in research settings. Multiple formulas for estimating GFR have been developed that use the readily available endogenous biomarkers creatinine and/or cystatin C. However, eGFR formulas have limitations, and an accurate mGFR is necessary in some clinical situations and for certain patient populations. We conducted a prospective, open-label study to evaluate a novel rapid technique for determining plasma volume and mGFR.Methods We developed a new exogenous biomarker, visible fluorescent injectate (VFI), consisting of a large 150-kD rhodamine derivative and small 5-kD fluorescein carboxymethylated dextrans. After a single intravenous injection of VFI, plasma volume and mGFR can be determined on the basis of the plasma pharmacokinetics of the rhodamine derivative and fluorescein carboxymethylated dextrans, respectively. In this study involving 32 adults with normal kidney function (n=16), CKD stage 3 (n=8), or CKD stage 4 (n=8), we compared VFI-based mGFR values with values obtained by measuring iohexol plasma disappearance. VFI-based mGFR required three 0.5-ml blood draws over 3 hours; iohexol-based mGFR required five samples taken over 6 hours. Eight healthy participants received repeat VFI injections at 24 hours.Results VFI-based mGFR values showed close linear correlation with the iohexol-based mGFR values in all participants. Injections were well tolerated, including when given on consecutive days. No serious adverse events were reported. VFI-based mGFR was highly reproducible.Conclusions The VFI-based approach allows for the rapid determination of mGFR at the bedside while maintaining patient safety and measurement accuracy and reproducibility.


Asunto(s)
Dextranos/farmacocinética , Fluoresceína/farmacocinética , Tasa de Filtración Glomerular , Volumen Plasmático , Sistemas de Atención de Punto , Insuficiencia Renal Crónica/fisiopatología , Rodaminas/farmacocinética , Adulto , Anciano , Estudios de Casos y Controles , Dextranos/administración & dosificación , Femenino , Fluoresceína/administración & dosificación , Colorantes Fluorescentes/administración & dosificación , Colorantes Fluorescentes/farmacocinética , Humanos , Inyecciones Intravenosas , Yohexol/farmacocinética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Rodaminas/administración & dosificación , Adulto Joven
19.
Radiology ; 289(2): 546-553, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30204073

RESUMEN

Purpose To determine if there is added benefit of using iodine maps from dual-energy (DE) CT in addition to conventional CT angiography images to diagnose pulmonary embolism (PE). Materials and Methods In this retrospective analysis, 1144 consecutive dual-energy CT angiography examinations performed from January through September 2014 at an oncologic referral center to evaluate for PE were reviewed. The 1144 examinations included 1035 patients (mean age, 58.7 years; range, 15-99 years). First, the location, level, and type (occlusive vs nonocclusive) of PEs on conventional CT angiograms were recorded. Iodine maps were then reviewed for defects suggestive of PE. Last, CT angiograms were rereviewed to detect additional PEs suggested by the iodine map. Consensus reviews were performed for examinations with PEs. The confidence interval of percentages was calculated by using the Clopper-Pearson method. Results On 147 of 1144 (12.8%) CT angiograms, a total of 372 PEs were detected at initial review. After review of the DE CT iodine map, 27 additional PEs were found on 26 of 1144 CT angiograms (2.3%; 95% confidence interval [CI]: 1.5%, 3.3%). Of the 27 additional PEs, six (22.2%) were segmental, 21 (77.8%) were subsegmental, 24 (88.9%) were occlusive, and three (11.1%) were nonocclusive. Eleven of 1144 (1.0%; 95% CI: 0.5%, 1.7%) CT angiograms had a new diagnosis of PE after review of the DE CT iodine maps. Conclusion Dual-energy CT iodine maps show a small incremental benefit for the detection of occlusive segmental and subsegmental pulmonary emboli. © RSNA, 2018.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Medios de Contraste/farmacocinética , Yohexol/farmacocinética , Arteria Pulmonar/diagnóstico por imagen , Embolia Pulmonar/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Yodo/farmacocinética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
20.
Crit Care Med ; 46(3): e190-e197, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29194145

RESUMEN

OBJECTIVE: Measurement of changing glomerular filtration rate in acute kidney injury remains problematic. We have previously used a continuous infusion of low-dose Iohexol to measure glomerular filtration rate in stable subjects and postulate that changes greater than 10.3% in critically ill patients indicate acute kidney injury. Our objective is to explore the extent to which continuous infusion of low-dose Iohexol can be a measure of changing glomerular filtration rate during acute kidney injury. DESIGN: Clinical observational exploratory study. SETTING: Adult ICU. PATIENTS: Three patient groups were recruited: nephrectomy group: predictable onset of acute kidney injury and outcome (n = 10); surgery group: predictable onset of acute kidney injury, unpredictable outcome (n = 11); and acute kidney injury group: unpredictable onset of acute kidney injury and outcome (n = 13). INTERVENTIONS: Continuous infusion of low-dose Iohexol was administered for 24-80 hours. Plasma (ClP) and renal (ClR) Iohexol clearances were measured at timed intervals. MEASUREMENTS AND MAIN RESULTS: Kidney Disease: Improved Global Outcomes acute kidney injury criteria were fulfilled in 22 patients (nephrectomy = 5, surgery = 4, and acute kidney injury = 13); continuous infusion of low-dose Iohexol demonstrated acute kidney injury in 29 patients (nephrectomy = 10, surgery = 8, acute kidney injury = 11). Dynamic changes in glomerular filtration rate were tracked in all patients. In the nephrectomy group, ClR decreased by an expected 50% (50.8% ± 11.0%). Agreement between ClP and ClR improved with increasing duration of infusion: bias of ClP versus ClR at 48 hours was -0.1 ± 3.6 mL/min/1.73 m (limits of agreement: -7.2 to 7.1 mL/min/1.73 m). Coefficient of variation of laboratory sample analysis was 2.4%. CONCLUSIONS: Continuous infusion of low-dose Iohexol is accurate and precise when measuring glomerular filtration rate and tracks changes in patients with differing risks of acute kidney injury. Continuous infusion of low-dose Iohexol may provide a useful standard against which to test novel biomarkers for the diagnosis of acute kidney injury.


Asunto(s)
Lesión Renal Aguda/fisiopatología , Medios de Contraste , Tasa de Filtración Glomerular , Yohexol , Lesión Renal Aguda/diagnóstico , Adulto , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Tasa de Filtración Glomerular/fisiología , Humanos , Infusiones Intravenosas , Yohexol/administración & dosificación , Yohexol/farmacocinética , Nefrectomía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA