Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(7): 4540-4549, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38127072

RESUMO

OBJECTIVES: Severe coagulopathy due to consumption of synthetic cannabinoids adulterated with brodifacoum, a long-acting anticoagulant, is an emerging worldwide hazard. Here, we review the spectrum of imaging findings in adulterated cannabinoid poisoning. MATERIALS AND METHODS: In this retrospective study, we used the Israeli Poison Information Center database to identify patients with cannabinoid-associated coagulopathy who presented to the Rambam Health Care Campus, where most patients were treated during an outbreak in northern Israel between September 2021 and June 2022. All relevant imaging studies for these patients were reviewed. We estimated the sensitivity of findings for cannabinoid-associated coagulopathy. Associations between a continuous variable and a dichotomous outcome were assessed with the Mann-Whitney U test. RESULTS: We identified 48 patients (mean age 40 years ± 9 [SD], 43 males) with 54 hospitalizations due to cannabinoid-associated coagulopathy. Symptomatic hemorrhage was documented in 50 (93%) cases at presentation, most of whom (78%) had hemorrhage from multiple systems. The most common bleeding site was the genitourinary collecting system, with a characteristic sign of suburothelial bleeding in 16/18 of performed abdominal CTs (sensitivity 89% [CI 65-99%] for cannabinoid-associated coagulopathy). Intramural bowel hematomas were noted in 70% (7/10) of CTs of patients with gastrointestinal bleeding. Incidental bleeding sites were identified on imaging in 24% of patients. An increased number of bleeding sites was associated with need for vasopressors (difference in bleeding sites 3.00 [95% CI 0.99-4.00], p = 0.026). CONCLUSION: CT plays a key role in the diagnosis and work-up of adulterated cannabinoid-associated coagulopathy. Characteristic signs include suburothelial hemorrhage and intramural bowel hematomas. CLINICAL RELEVANCE STATEMENT: Recognition of radiological signs of adulterated synthetic cannabinoid-associated coagulopathy is critical for optimizing outbreak control on the public health level and ensuring timely treatment on the individual patient level. KEY POINTS: • Severe coagulopathy due to consumption of synthetic cannabinoids adulterated with brodifacoum, a long-acting anticoagulant, is an emerging worldwide threat. • Characteristic imaging signs include suburothelial bleeding, intramural bowel hematomas, and rare incidental bleeding sites. • Imaging has a pivotal role in optimizing outbreak control and ensuring timely and appropriate treatment.


Assuntos
4-Hidroxicumarinas , Canabinoides , Humanos , Masculino , Adulto , Feminino , Canabinoides/intoxicação , Estudos Retrospectivos , 4-Hidroxicumarinas/intoxicação , Israel/epidemiologia , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Contaminação de Medicamentos , Anticoagulantes/intoxicação , Transtornos da Coagulação Sanguínea/induzido quimicamente
2.
Pacing Clin Electrophysiol ; 47(4): 503-510, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38375917

RESUMO

INTRODUCTION: Arrhythmogenic cardiomyopathy (AC) is an inherited cardiomyopathy characterized by fibro-fatty replacement of cardiomyocytes, leading to life-threatening ventricular arrhythmia and heart failure. Pathogenic variants of desmoglein2 gene (DSG2) have been reported as genetic etiologies of AC. In contrast, many reported DSG2 variants are benign or variants of uncertain significance. Correct genetic variant classification is crucial for determining the best medical therapy for the patient and family members. METHODS: Pathogenicity of the DSG2 Ser194Leu variant that was identified by whole exome sequencing in a patient, who presented with ventricular tachycardia and was diagnosed with AC, was investigated by electron microscopy and immunohistochemical staining of endomyocardial biopsy sample. RESULTS: Electron microscopy demonstrated a widened gap in the adhering junction and a less well-organized intercalated disk region in the mutated cardiomyocytes compared to the control. Immunohistochemical staining in the proband diagnosed with AC showed reduced expression of desmoglein 2 and connexin 43 and intercalated disc distortion. Reduced expression of DSG2 and Connexin 43 were observed in cellular cytoplasm and gap junctions. Additionally, we detected perinuclear accumulation of DSG2 and Connexin 43 in the proband sample. CONCLUSION: Ser194Leu is a missense pathogenic mutation of DSG2 gene associated with arrhythmogenic left ventricular cardiomyopathy.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Taquicardia Ventricular , Humanos , Conexina 43/genética , Conexina 43/metabolismo , Displasia Arritmogênica Ventricular Direita/genética , Cardiomiopatias/complicações , Mutação/genética , Arritmias Cardíacas/complicações , Taquicardia Ventricular/genética , Taquicardia Ventricular/complicações , Miócitos Cardíacos/metabolismo , Desmogleína 2/genética , Desmogleína 2/metabolismo
3.
Eur Radiol ; 32(1): 132-142, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34136947

RESUMO

OBJECTIVES: We sought to evaluate cardiac CT angiography (CCTA)-based assessment of left atrial (LA) function as a predictor of hospitalizations for heart failure (HF) and cardiovascular (CV) mortality. METHODS: LA function was evaluated using automatic derivation of LA volumes to calculate LA total emptying fraction (LATEF) in 788 consecutive patients with normal sinus rhythm who had undergone spiral CT scans. The relationship between LATEF evaluated by CCTA and the composite endpoint of admission for HF or CV mortality was analyzed using Cox models. RESULTS: During a median follow-up of 4 years, there were 100 events, 62 HF hospitalizations, and 38 cardiovascular deaths. Mean LATEF was 30.7 ± 10.7% and 40.5 ± 11.2% in patients with and without events, respectively (p < 0.0001). A high LATEF (upper tertile > 46%) was associated with a very low event rate (3.5% at 6 years [95% CI 1.7-7.1%]). The adjusted HR for HF or CV mortality was 4.37 (95% CI 1.99-9.60) in the lowest LATEF tertile, and 2.29 (95% CI 1.03-5.14) in the middle tertile, relative to the highest tertile. For the endpoint of HF alone, adjusted HR for the lowest LATEF tertile was 5.93 (95% CI 2.23-15.82) and for the middle tertile 2.89 (95% CI 1.06-7.86). The association of LATEF with outcome was similar for patients with both reduced and preserved left ventricular (LV) ejection fraction (Pinteraction = 0.724). Reduced LATEF was associated with a high event rate, even when coupled with normal LA volume. CONCLUSION: CCTA-derived LA function is a predictor of HF hospitalization or CV death, independent of clinical risk factors, LA volume, and LV systolic function. KEY POINTS: • Left atrial function can be automatically derived from cardiac CTA scans. • Cardiac CTA-derived left atrial function is a predictor of hospitalization for heart failure and cardiovascular death. • Evaluation of left atrial function could be useful in identifying patients at risk of heart failure.


Assuntos
Função do Átrio Esquerdo , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Prognóstico , Volume Sistólico , Tomografia , Função Ventricular Esquerda
4.
J Comput Assist Tomogr ; 45(2): 242-247, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33661156

RESUMO

OBJECTIVES: We aimed to assess the agreement between cardiac computed tomography (CT) and echo for diagnosing advanced diastolic dysfunction (DD) and to assess the prognostic value of CT-based parameters. METHODS: One hundred one consecutive patients who had both CT and echo-Doppler within 1 month were included. Diastolic function was assessed by CT using a previously validated method, based on left atrial volume changes, and compared with echocardiography grades 0 to 3. Patients were followed up for a combined outcome of cardiac death and hospitalization for heart failure. RESULTS: By operating characteristic curve analysis, the best CT-based parameter for predicting advanced DD based on echo was left atrial total emptying fraction. Left atrial total emptying fraction <36% had sensitivity/specificity of 76%/86%. Agreement between echo and CT for detecting advanced (grades 2/3) DD was substantial (κ = 0.62, P < 0.0001). By Cox multivariate analysis, left atrial total emptying fraction was a powerful independent predictor of outcome at 3 years (hazard ratio, 8.0 [2.2-28.4]; P < 0.0001). CONCLUSIONS: Computed tomography-based assessment of DD has a good agreement with echo-Doppler-based results. Left atrial total emptying fraction seems to have a strong prognostic value.


Assuntos
Diástole/fisiologia , Ecocardiografia Doppler , Átrios do Coração/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Disfunção Ventricular/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
5.
J Heart Valve Dis ; 26(2): 130-138, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28820541

RESUMO

BACKGROUND: A comparison was made between the accuracy of and time saved by using novel automated software for pre-procedural computed tomography (CT) planning before transcatheter aortic valve implantation (TAVI) and manual methods. Preprocedural CT to assess aortic annulus dimensions and predict the optimal C-arm implant angle before TAVI can reduce complications related to incorrect prosthesis sizing and positioning. METHODS: A total of 61 consecutive patients underwent TAVI using either the SAPIEN XT or CoreValve prosthesis. Pre-procedural CT scans were analysed using three methods: automatic; semi-automatic; and manual. For each method, annular dimensions were measured and the optimal implantation angle was predicted. After TAVI the actual post-deployment angle orthogonal to the prosthesis was determined using aortic fluoroscopy. The difference between the predicted angle by CT and the measured post-deployment angle was calculated for each method. RESULTS: For all methods the mean angular difference with the actual post-deployment angle was similar at ~9 ± 7°. There was a significant difference between the SAPIEN XT (6.6 ± 5.8°) and CoreValve (11.5 ± 6.9°, p <0.001) prostheses due to a consistently greater left anterior oblique and caudal angulation for the CoreValve. Although the annular area correlated well among all methods, 'automatic' results were consistently larger than 'manual' results. Interobserver variability was low for all measures. The fully automatic method saved 98 s, and the semiautomatic method 40 s per case. CONCLUSIONS: The use of automatic software enabled a rapid and accurate prediction of implantation angles, though results differed for specific manufacturers. Annular areas were overestimated by the automatic method, and thus required manual adjustments.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/fisiopatologia , Automação , Feminino , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Estudos Retrospectivos , Índice de Gravidade de Doença , Software , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
6.
J Comput Assist Tomogr ; 41(3): 339-343, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27798446

RESUMO

OBJECTIVES: Hypertrophic cardiomyopathy (HCM) is characterized by diastolic dysfunction, which is difficult to assess by noninvasive methods. We hypothesized that measurement of simultaneous left ventricular (LV) and left atrial (LA) volume changes by cardiac computed tomography would be useful in the assessment of diastolic function in HCM. METHODS: We studied 21 patients with HCM and 21 age-matched controls. The LA and LV volumes were calculated and early and late diastolic volume changes derived. RESULTS: The HCM patients had significantly larger LA volumes and reduced LA total emptying fraction (30 ± 7% vs 42 ± 6%; P < 0.0001). Conduit volume was increased (30 ± 6 vs 22 ± 4 mL/m; P < 0.0001) and contributed a significantly higher proportion of total LV diastolic filling, suggesting that passive filling of the LV compensates for LA dysfunction, but at the expense of increased pulmonary filling pressure. CONCLUSIONS: This study suggests that simultaneous depiction of computed tomography-derived LV and LA volume changes can characterize diastolic dysfunction in HCM.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Diástole/fisiologia , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Adulto , Idoso , Cardiomiopatia Hipertrófica/complicações , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico/fisiologia , Disfunção Ventricular Esquerda/complicações
7.
Eur Radiol ; 26(10): 3626-34, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26809292

RESUMO

OBJECTIVES: With increasing use of prospective scanning techniques for cardiac computed tomography (CT), meaningful evaluation of chamber volumes is no longer possible due to lack of normal values. We aimed to define normal values for mid-diastolic (MD) chamber volumes and to determine their significance in comparison to maximum volumes. METHODS: Normal ranges at MD for left ventricular (LV) volume and mass and left atrial (LA) volume were determined from 101 normal controls. Thereafter, 109 consecutive CT scans, as well as 21 post-myocardial infarction patients, were analysed to determine the relationship between MD and maximum volumes. RESULTS: MD volumes correlated closely with maximal volumes (r = 0.99) for both LV and LA, and could estimate maximum volumes accurately. LV mass, measured at ED or MD, were very similar (r = 0.99). Abnormal MD volumes had excellent sensitivity and specificity to detect chamber enlargement based on maximal volumes (LV 86 %, 100 %, respectively; LA 100 %, 92 %, respectively). CONCLUSION: A single MD phase can identify patients with cardiomegaly or LV hypertrophy with a high degree of accuracy and MD volumes can give an accurate estimate of maximum LV and LA volumes. KEY POINTS: • Traditionally, helical cardiac CT provided clinically important information from chamber volume analysis. • Mid-diastolic left atrial and ventricular volumes correlate closely with maximal volumes. • We derive normal values for mid-diastolic left atrial and ventricular volumes and mass. • A single mid-diastolic phase can be used to identify chamber enlargement and hypertrophy.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Infarto do Miocárdio/fisiopatologia , Adulto , Idoso , Diástole/fisiologia , Feminino , Átrios do Coração/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Variações Dependentes do Observador , Estudos Prospectivos , Valores de Referência , Sensibilidade e Especificidade , Volume Sistólico , Sístole/fisiologia , Função Ventricular Esquerda/fisiologia
8.
Circ Cardiovasc Imaging ; 17(5): e016276, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716653

RESUMO

BACKGROUND: Quantification of left atrial (LA) conduit function and its contribution to left ventricular (LV) filling is challenging because it requires simultaneous measurements of both LA and LV volumes. The functional relationship between LA conduit function and the severity of diastolic dysfunction remains controversial. We studied the role of LA conduit function in maintaining LV filling in advanced diastolic dysfunction. METHODS: We performed volumetric and flow analyses of LA function across the spectrum of LV diastolic dysfunction, derived from a set of consecutive patients undergoing multiphasic cardiac computed tomography scanning (n=489). From LA and LV time-volume curves, we calculated 3 volumetric components: (1) early passive emptying volume; (2) late active (booster) volume; and (3) conduit volume. Results were prospectively validated on a group of patients with severe aortic stenosis (n=110). RESULTS: The early passive filling progressively decreased with worsening diastolic function (P<0.001). The atrial booster contribution to stroke volume modestly increases with impaired relaxation (P=0.021) and declines with more advanced diastolic function (P<0.001), thus failing to compensate for the reduction in early filling. The conduit volume increased progressively (P<0.001), accounting for 75% of stroke volume (interquartile range, 63-81%) with a restrictive filling pattern, compensating for the reduction in both early and booster functions. Similar results were obtained in patients with severe aortic stenosis. The pulmonary artery systolic pressure increased in a near-linear fashion when the conduit contribution to stroke volume increased above 60%. Maximal conduit flow rate strongly correlated with mitral E-wave velocity (r=0.71; P<0.0001), indicating that the increase in mitral E wave in diastolic dysfunction represents the increased conduit flow. CONCLUSIONS: An increase in conduit volume contribution to stroke volume represents a compensatory mechanism to maintain LV filling in advanced diastolic dysfunction. The increase in conduit volume despite increasing LV diastolic pressures is accomplished by an increase in pulmonary venous pressure.


Assuntos
Estenose da Valva Aórtica , Função do Átrio Esquerdo , Diástole , Volume Sistólico , Disfunção Ventricular Esquerda , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Função do Átrio Esquerdo/fisiologia , Idoso , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Volume Sistólico/fisiologia , Índice de Gravidade de Doença , Átrios do Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Valor Preditivo dos Testes
9.
Am J Cardiol ; 181: 71-78, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-35963824

RESUMO

Recent data indicate that left atrial (LA) function assessment by cardiac computed tomography (CT) is closely related to diastolic dysfunction (DD). Therefore, we aimed to perform a direct comparison between CT and echocardiography for diagnosis of advanced DD and prediction of future heart failure or cardiovascular death. We identified 340 patients who had both spiral cardiac CT and a proximate echocardiogram. LA total emptying fraction (LATEF), a measure of global LA function, was automatically calculated from CT data, as a surrogate for diastolic function and was compared with echocardiographic grades of diastolic function. The area under the receiver operating characteristic curve for LATEF to differentiate between advanced DD (grades 2 and 3) and all other grades was 0.84 (0.79 to 0.88). Over a median of 4 years, 69 events (admissions for heart failure and cardiovascular deaths) occurred. By multivariate Cox analysis, LATEF <40% provided incremental prognostic information after adjustments for advanced DD by echocardiography (hazard ratio 2.15, 95% confidence interval 1.13 to 3.94). There was a significant interaction (p = 0.03) between LATEF and echocardiography-based diastolic grades. Stratified analyses within the diastolic function groups revealed that LATEF <40% was equivalent to echocardiography in predicting events in the subgroup with advanced DD by echocardiography (p = 0.20) but was associated with a significantly higher event rates in patients with normal filling pressures (p = 0.0001) or indeterminate diastolic function (p = 0.04) by echocardiography. In conclusion, LA function derived from CT can accurately detect advanced DD diagnosed by echocardiography and has additive value to echocardiography-derived DD.


Assuntos
Ecocardiografia , Insuficiência Cardíaca , Função do Átrio Esquerdo , Diástole , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Tomografia
10.
Eur J Nucl Med Mol Imaging ; 38(10): 1917-25, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21688049

RESUMO

PURPOSE: Early risk stratification in patients with non-ST elevation acute coronary syndromes (NSTE-ACS) is important since the benefit from more aggressive and costly treatment strategies is proportional to the risk of adverse clinical events. In the present study we assessed whether hybrid single photon emission computed tomography (SPECT)/coronary computed tomography angiography (CCTA) technology could be an appropriate tool in stratifying patients with NSTE-ACS. METHODS: SPECT/CCTA was performed in 90 consecutive patients with NSTE-ACS. The Thrombolysis in Myocardial Infarction risk score (TIMI-RS) was used to classify patients as low- or high-risk. Imaging was performed using SPECT/CCTA to identify haemodynamically significant lesions defined as >50% stenosis on CCTA with a reversible perfusion defect on SPECT in the corresponding territory. RESULTS: CCTA demonstrated at least one lesion with >50% stenosis in 35 of 40 high-risk patients (87%) as compared to 14 of 50 low-risk patients (35%; TIMI-RS<3; p<.0001). Of the 40 high-risk and 50 (16%) low-risk TIMI-RS patients, 16 (40%) and 8 (16%), respectively, had haemodynamically significant lesions (p=0.01). Patients defined as high-risk by a high TIMI-RS, a positive CCTA scan or both (n=45) resulted in a sensitivity of 95%, specificity of 49%, PPV of 35% and NPV of 97% for having haemodynamically significant coronary lesions. Those with normal perfusion were spared revascularization procedures, regardless of their TIMI-RS. CONCLUSION: Noninvasive assessment of coronary artery disease by SPECT/CCTA may play an important role in risk stratification of patients with NSTE-ACS by better identifying the subgroup requiring intervention.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Hemodinâmica , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Síndrome Coronariana Aguda/complicações , Adulto , Idoso , Angiografia Coronária , Determinação de Ponto Final , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Medição de Risco
11.
AJR Am J Roentgenol ; 196(2): W152-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21257856

RESUMO

OBJECTIVE: The purpose of this study was to quantify the absorbed radiation dose received by the adult female breast during coronary CT angiography (CTA) and to evaluate the effectiveness of various dose reduction strategies. MATERIALS AND METHODS: An adult female thoracic anthropomorphic phantom was scanned using eight different clinical coronary CTA protocols that varied in detector configuration (320 × 0.5 mm or 64 × 0.5 mm), x-ray tube activation (full R-R, 65% R-R, or 70-80% R-R), use of tube current modulation, and use of breast shields. Direct dosimetry measurements were performed using Gafchromic film to determine the absorbed breast dose. RESULTS: Retrospective helical data acquisition using a 64-detector array and a full cardiac cycle without dose modulation or breast shielding is associated with an average absorbed breast dose of 82.9 mGy. Optimization of coronary CTA technique using a 320-detector array and a 70-80% cardiac phase reduces the absorbed breast dose by 78.9% to 17.5 mGy, whereas breast shields used in isolation reduces breast dose by up to 46.8%. CONCLUSION: The implementation of clinically validated coronary CTA protocols using large-area detector acquisition and prospective ECG gating with limited x-ray tube activation results in substantial breast dose savings of up to 78.9% and should be used whenever possible in combination with bismuth breast shields to achieve further dose reduction.


Assuntos
Carga Corporal (Radioterapia) , Mama/química , Angiografia Coronária , Exposição Ambiental/análise , Doses de Radiação , Tomografia Computadorizada por Raios X , Adulto , Bismuto , Mama/efeitos da radiação , Calibragem , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Eletrocardiografia , Feminino , Humanos , Imagens de Fantasmas , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas
13.
Ann Gastroenterol ; 34(2): 282-284, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33654371

RESUMO

Both fully (FCSEMS) and partially (PCSEMS) covered self-expandable metal stents are used for the endoscopic management of leaks, perforations, and fistulas. PCSEMS have lower migration rates as their uncovered flanges allow for anchorage into the surrounding tissue, but this consequently makes them difficult to be removed, with reported cases of esophageal perforation during the removal of the embedded PCSEMS. Stent-in-stent technique is mostly used, where a FCSEMS is placed co-axially into an existing PCSEMS causing pressure necrosis and facilitating subsequent removal of both stents. This technique, although effective, is expensive, requiring the use of a second stent. In this report, we describe a series of 3 patients with embedded PCSEMS removed by a new endoscopic technique, i.e., endoscopic sub-stent space dissection, without using a second stent.

14.
Eur Radiol ; 19(1): 24-30, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18690454

RESUMO

The aim of this study was to determine the accuracy of multidetector row CT angiography in the diagnosis of acute mesenteric ischemia. Ninety-three consecutive studies on 91 patients with clinically suspected acute mesenteric ischemia underwent abdominal CT angiography as the first, and usually the sole, diagnostic procedure. CT was performed with a multidetector 16-row CT system from the level of the diaphragm to the pelvis in two phases: early arterial and late portal phase. CT examinations were reviewed by the duty radiologist. Final diagnosis was established by a senior radiologist. CTA was diagnostic in 92 studies. Mesenteric ischemia was diagnosed in 18 patients, 14 of them were of the thromboembolic type and four from the nonocclusive type. Positive CTA findings were confirmed by surgery in 13 patients and by clinical follow-up in three cases. Other reasons for abdominal pain were diagnosed by CT in 38 patients out of the remaining 74. There were two false positive and two false negative CT results, resulting in an overall accuracy of 95.6%. Multidetector CT angiography is a fast and accurate investigation for the diagnosis of acute mesenteric ischemia and in most cases can be used as the sole diagnostic procedure.


Assuntos
Angiografia/métodos , Isquemia/diagnóstico por imagem , Artéria Mesentérica Superior/diagnóstico por imagem , Oclusão Vascular Mesentérica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
J Comput Assist Tomogr ; 33(2): 204-10, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19346846

RESUMO

OBJECTIVE: : Because most contemporary workstations offer quantitative analysis of regional function by multidetector computed tomography, we aimed to establish typical values for normal, hypokinetic, and akinetic regions, and to establish optimal thresholds to differentiate between normal and abnormal values. METHODS: : For 33 patients, quantitative regional functional parameters were compared with visual analysis by both multidetector computed tomography and echocardiography. Normal values were established to normalize for segmental variability. Optimal thresholds were established to differentiate between normal and abnormal segments by receiver operating characteristic analysis. RESULTS: : Akinetic, hypokinetic, and normokinetic segments demonstrated significant differences (P < 0.0001) for end-systolic thickness (mean [95% confidence interval], 9.4 [4.5-14.3], 11.7 [7.2-16.2], and 14.3 mm [8.2-20.3 mm]), respectively; thickening, 24% [-22% to 71%], 45% [-16% to 106%], and 82% [10%-154%]), respectively; and motion, 3.5 [-2.0 to 8.9], 6.1 [-0.2 to 12.4], and 8.5 mm [1.8-15.3 mm], respectively). Thickening performed best with area under the curve of 0.87 and sensitivity equal to specificity of 82%. Intraobserver variability was good, but interobserver variability was only moderate. CONCLUSIONS: : Quantification of regional myocardial function can be performed to assist the physician in mapping left ventricular function.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Análise de Variância , Mapeamento Potencial de Superfície Corporal/métodos , Endocárdio/diagnóstico por imagem , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pericárdio/diagnóstico por imagem , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Valores de Referência , Sensibilidade e Especificidade , Software , Tomografia Computadorizada por Raios X/estatística & dados numéricos
16.
Ultrasound Med Biol ; 34(4): 586-97, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18096303

RESUMO

The purpose of this study was to estimate tissue changes during radiofrequency (RF) ablation by correlating echo frequency shifts and temperature elevations. Experiments were performed on phantoms (tissue mimicking gel) and in-vitro turkey breast. Heating was performed with a modified RF-ablation system. Intermittent RF was applied and the temperature at the electrode tip was continually measured by an embedded thermocouple. Various voltages (10-30V) were applied to achieve a wide range of temperature elevations between 10 and 80 degrees C and ablation sizes between 5 and 27 mm in width. B-mode images and raw data were acquired every 5 s by a modified ultrasound imaging system. The raw data from each line and frame was processed using an algorithm to measure spectral shifts of the echo signals in the power spectrum. The phantom experiments showed positive frequency shifts as the temperature rose, with dependency on the heating rate. A linear relationship (R(2) > 0.96) was found between the RF-applied voltage and the width of the heated area, defined by frequency changes larger than 0.05 MHz. In-vitro experiments showed a correlation (R(2) = 0.84) between the width of the coagulated area and the maximal width of the region with more than 0.12 MHz frequency shifts, but a lower correlation (R(2) = 0.4) between the width of the coagulated area and the temperature elevation. In conclusion, correlation was found between echo frequency shifts and temperature elevations and between echo frequency shifts and the width of the ablated area during intermittent RF ablation. Our results suggest that, with further refinement and validation, ultrasound could be used to measure RF heating and its induced coagulation.


Assuntos
Ablação por Cateter/métodos , Ultrassonografia de Intervenção/métodos , Animais , Ablação por Cateter/instrumentação , Estudos de Viabilidade , Interpretação de Imagem Assistida por Computador/métodos , Técnicas In Vitro , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/cirurgia , Imagens de Fantasmas , Temperatura , Perus , Ultrassonografia de Intervenção/instrumentação
17.
Isr Med Assoc J ; 10(10): 702-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19009950

RESUMO

BACKGROUND: Multi-detector computed tomography has advanced enormously and now enables non-invasive evaluation of coronary arteries as well as cardiac anatomy, function and perfusion. However, the role of cardiac MDCT is not yet determined in the medical community and, consequently, many clinically unnecessary scans are performed solely on a self-referral basis. OBJECTIVES: To prospectively evaluate the role of a cardiologist consultation and recommendation prior to the scan, and the influence on the diagnostic yield of cardiac MDCT. METHODS: In our center a CT service was initiated, but with the prerequisite approval of a cardiologist before performance of the CT. Each individual who wanted and was willing to pay for a cardiac CT was interviewed by an experienced cardiologist who determined whether cardiac MDCT was the most appropriate next test in the cardiovascular evaluation. Subjects were classified into three groups: a) those with a normal or no prior stress test, no typical symptoms and no significant risk factors of coronary artery disease were recommended to perform a stress test or to remain under close clinical follow-up without MDCT; b) those with an equivocal stress test, atypical symptoms and/or significant risk factors were allowed to have cardiac MDCT; and c) those with positive stress test or clinically highly suspected CAD were advised to go directly to invasive coronary angiography. CT findings were categorized as normal CAD (normal calcium score and no narrowings), < 50% and > 50% CAD. RESULTS: A total of 254 people were interviewed, and in only 39 cases did the cardiologist approve the CT. However, 61 of the 215, despite our recommendation not to undergo CT, decided to have the scan. Assessment of the 100 cases that underwent MDCT showed a statistically significant better discrimination of significant CAD, according to the cardiologist's recommendation: MDCT not recommended in 3/54 (6%) vs. MDCT recommended in 12/39 (31%) vs. recommended invasive coronary angiography in 4/7 (57%)(P<0.001). CONCLUSIONS: Detection of coronary calcification, as well as MDCT angiography can provide clinically useful information if applied to suitable patient groups. It is foreseeable that MDCT angiography will become part of the routine workup in some subsets of patients with suspected CAD. Selection of patients undergoing MDCT scans by a cardiologist improves the ability of the test to stratify patients, preventing unnecessary scans in both high and low risk patients.


Assuntos
Cardiologia/métodos , Cardiopatias/diagnóstico , Encaminhamento e Consulta/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos
18.
Int J Cardiovasc Imaging ; 34(5): 793-802, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29260346

RESUMO

To test the feasibility of assessing mitral regurgitation (MR) severity using cardiac magnetic resonance (CMR) 4D velocity vectors to quantify regurgitant volume (RVol) by analysis of the proximal flow convergence, compared to Doppler based proximal isovelocity surface area (PISA) and CMR volume-based methods. In a prospectively designed study, 27 patients with various grades of MR underwent CMR and echo-Doppler on the same day. By CMR, multiple slices were obtained parallel to the mitral valve by phase-contrast imaging, using 3D velocity vectors, as well as short-axis cine images for left and right ventricular volume measurements. Using dedicated software developed in our laboratory, the perimeter of the proximal flow convergence region was semi-automatically measured for each temporal phase, and for each short-axis slice. The CMR-PISA RVol was calculated as the sum of PISA perimeters throughout systole, multiplied by slice width. For comparison, CMR-volumetric RVol was calculated by 2 methods: Volumetric (difference between left and right ventricular stroke volumes) and Flow-based (stroke volume -aortic flow). Echo-PISA RVol was calculated by echo-Doppler based PISA method. RVol by CMR-PISA correlated highly with echo-PISA (r = 0.87) and with CMR-volumetric (r = 0.86) and CMR-flow (r = 0.72). For comparison Doppler-RVol and CMR-volume-based RVol had r = 0.83. On average CMR-PISA was 16 ± 25 ml less than echo-PISA, but 12 ± 22 ml larger than CMR-volumetric RVol. The observed 3D shape of the PISA envelope by 4D-CMR resembled a hemiellipsoid rather than a hemisphere. This feasibility study suggests that CMR-based 4D-PISA may be able to assess MR severity quantitatively without any geometric assumptions.


Assuntos
Ecocardiografia Doppler em Cores , Ecocardiografia Doppler de Pulso , Hemodinâmica , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Variações Dependentes do Observador , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
19.
Nat Clin Pract Nephrol ; 3(11): 631-5, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17957200

RESUMO

BACKGROUND: A 53-year-old man presented to hospital 2 hours after the abrupt onset of left upper abdominal pain. He was treated with analgesics and discharged after 4 hours of observation, but presented to another hospital 2 hours later with severe left abdominal pain. His past medical history included ischemic dilated cardiomyopathy due to recurrent myocardial infarction. INVESTIGATIONS: Physical examination, electrocardiography, laboratory investigations, contrast-enhanced computed tomography, and transesophageal echocardiography. DIAGNOSIS: Renal artery thromboembolism resulting from dilated cardiomyopathy, severely reduced cardiac function and an intracardiac thrombus. MANAGEMENT: Anticoagulation with unfractionated heparin followed by enoxaparin and warfarin.


Assuntos
Trombose Coronária/complicações , Infarto/etiologia , Nefropatias/etiologia , Dor Abdominal/etiologia , Doença Aguda , Anticoagulantes/administração & dosagem , Cardiomiopatia Dilatada/complicações , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/tratamento farmacológico , Diagnóstico Diferencial , Ecocardiografia Transesofagiana , Enoxaparina/administração & dosagem , Humanos , Infarto/diagnóstico por imagem , Nefropatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Artéria Renal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Varfarina/administração & dosagem
20.
Rambam Maimonides Med J ; 8(4)2017 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-28777073

RESUMO

Recent developments in diagnostic imaging herald a new approach to diagnosis and management of prostate cancer. Multimodality fusion that combines anatomic with functional imaging data has surpassed either of the two alone. This opens up the possibility to "find and fix" malignancy with greater accuracy than ever before. This is particularly important for prostate cancer because it is the most common male cancer in most developed countries. This article describes technical advances under investigation at our institution and others using multimodality image fusion of magnetic resonance imaging (MRI), transrectal ultrasound (TRUS), and PSMA PET/CT (defined as the combination of prostate-specific membrane antigen [PSMA], positron emission tomography [PET], and computed tomography [CT]) for personalized medicine in the diagnosis and focal therapy of prostate cancer with high-intensity focused ultrasound (HiFUS).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA