Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Healthc Eng ; 2022: 4826507, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35388332

RESUMO

There is no detailed biomechanical research about the hybrid CBT-TT (CBT screws at cranial level and TT screws at caudal level) and TT-CBT (TT screws at cranial level and CBT screws at caudal level) techniques with finite element (FE) method. Therefore, the purpose of this study was to evaluate and provide specific biomechanical data of the hybrid lumbar posterior fixation system and compare with traditional pedicle screw and cortical screw trajectories without fusion, in FE method. Specimens were from the anatomy laboratory of Xinjiang Medical University. Four FE models of the L4-L5 lumbar spine segment were generated. For each of these, four implanted models with the following instruments were created: bilateral traditional trajectory screw fixation (TT-TT), bilateral cortical bone trajectory screw fixation (CBT-CBT), hybrid CBT-TT fixation, and hybrid TT-CBT fixation. A 400 N compressive load with 7.5 Nm moments was applied so as to simulate flexion, extension, left lateral bending, right lateral bending, left rotation, and right rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation in four implanted models were compared. CBT-TT displayed a lower ROM of the fixation segment (3.82 ± 0.633°) compared to TT-TT (4.78 ± 0.306°) and CBT-CBT (4.23 ± 0.396°). In addition, CBT-TT showed a lower ROM of the posterior fixation (0.595 ± 0.108°) compared to TT-TT (0.795 ± 0.103°) and CBT-CBT (0.758 ± 0.052°). The intervertebral disc stress of CBT-TT (4.435 ± 0.604 MPa) was lower than TT-TT (7.592 ± 0.387 MPa) and CBT-CBT (6.605 ± 0.600 MPa). CBT-TT (20.228 ± 3.044 MPa) and TT-CBT (12.548 ± 2.914 MPa) displayed a lower peak von Mises stress of the posterior fixation compared to TT-TT (25.480 ± 3.737 MPa). The hybrid CBT-TT and TT-CBT techniques offered superior fixation strength compared to the CBT-CBT and TT-TT techniques.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Região Lombossacral/cirurgia , Amplitude de Movimento Articular , Fusão Vertebral/métodos
2.
Front Surg ; 9: 911742, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35923441

RESUMO

Background: Hybrid fixation techniques including the both modified cortical bone trajectory (MCBT) and traditional trajectory (TT) at the L4 and L5 lumbar segment are firstly proposed by our team. Therefore, the purpose of this study is to evaluate and provide specific biomechanical data of the hybrid fixation techniques including the MCBT and TT. Methods: Four human cadaveric specimens were from the anatomy laboratory of Xinjiang Medical University. Four finite-element (FE) models of the L4-L5 lumbar spine were generated. For each of them, four implanted models with the following fixations were established: TT-TT (TT screw at the cranial and caudal level), MCBT-MCBT (MCBT screw at the cranial and caudal level), hybrid MCBT-TT (MCBT screw at the cranial level and TT screw at the caudal level), and TT-MCBT (TT screw at the cranial level and MCBT screw at the caudal level). A 400-N compressive load with 7.5 N/m moments was applied to simulate flexion, extension, lateral bending, and rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation were compared. Results: Compared to the TT-TT group, the MCBT-TT showed a significant lower ROM of the L4-L5 segment (p ≤ 0.009), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.041). TT-MCBT groups showed a significant lower ROM of the L4-L5 segment (p ≤ 0.012), lower ROM of the posterior fixation (p < 0.001), lower intervertebral disc stress (p < 0.001), and lower posterior fixation stress (p ≤ 0.038). Conclusions: The biomechanical properties of the hybrid MCBT-TT and TT-MCBT techniques at the L4-L5 segment are superior to that of stability MCBT-MCBT and TT-TT techniques, and feasibility needs further cadaveric study to verify.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA