Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 60(3): 361-369, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35041777

RESUMO

OBJECTIVES: Medical laboratories may, at their own discretion, exceed but not undercut regulatory quality requirements. Available economic resources, however, may drive or hinder eagerness to exceed minimum requirements. Depending on the respective scopes of regulatory and economic framework conditions, differing levels of quality efforts to safeguard laboratory performance can be anticipated. However, this has not yet been investigated. METHODS: Immunohaematology external quality assessment (EQA) results collected by 26 EQA providers from their participant laboratories in 73 countries from 2004 to 2019 were evaluated. Error rates were aggregated in groups according to the respective national regulatory and economic framework conditions, to whether or not expert advice was provided in case of incorrect results, and the frequency of EQA samples. RESULTS: These representative data indicate no association between national regulatory (mandatory participation in EQA, monitoring of performance of individual laboratories by authorities, financial consequences of incorrect results) and economic (level of national income, share of national health expenditure) conditions to the quality performance of medical laboratories in immunohaematology. However, EQA providers' support for laboratories in the event of incorrect results appear to be associated with lower error rates, but a high EQA sample frequency with higher error rates. CONCLUSIONS: Further research into the impact of introducing or changing services of EQA providers is needed to confirm the results found in this first of its kind study.


Assuntos
Hematologia , Laboratórios , Humanos , Garantia da Qualidade dos Cuidados de Saúde
2.
Toxicol Appl Pharmacol ; 280(2): 216-23, 2014 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-25110056

RESUMO

Antineoplastic treatment with cisplatin is frequently complicated by nephrotoxicity. Although oxidative stress may be involved, the pathogenic mechanisms responsible for renal damage have not been completely clarified. In order to investigate the role of the renal kinin system in this condition, a group of rats was submitted to high potassium diet to stimulate the synthesis and excretion of tissue kallikrein 1 (rKLK1) previous to an intraperitoneal injection of 7 mg/kg cisplatin. A significant reduction in lipoperoxidation, evidenced by urinary excretion of malondialdehyde and renal immunostaining of hidroxy-nonenal, was accompanied by a decline in apoptosis. Coincident with these findings we observed a reduction in the expression of renal KIM-1 suggesting that renoprotection may be occurring. Stimulation or indemnity of the renal kinin system deserves to be evaluated as a complementary pharmacological measure to diminish cisplatin nephrotoxicity.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Antineoplásicos/toxicidade , Cisplatino/toxicidade , Calicreínas/fisiologia , Animais , Moléculas de Adesão Celular/análise , Rim/efeitos dos fármacos , Masculino , Malondialdeído/urina , Ratos , Ratos Sprague-Dawley , Superóxido Dismutase/metabolismo , Superóxido Dismutase-1
3.
Front Immunol ; 14: 1299639, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38116010

RESUMO

Introduction: The D antigen variants are classified as weak, partial, and extremely weak (DEL) and can be differentiated using molecular tests. In Chile, the laboratories of local blood centers do not identify variants of the D antigen, referring them for study to the Reference Laboratory of the Public Health Institute of Chile. So, our aim was to talk about the results of the molecular analysis of variants of the D antigen in samples that had different results in the serological classification. Methods: In the D antigen classification of the Rh system, 479 samples with serological discrepant results were sent for molecular analysis. The Rh phenotype was performed with monoclonal anti-C, anti-c, anti-E, and anti-e antisera by direct agglutination. To find the D antigen, researchers used direct agglutination with monoclonal antisera and indirect antiglobulin testing with the column (gel) agglutination method. Molecular analysis was performed with a polymerase chain reaction with sequence-specific primers (SSP-PCR) and sequencing. Results and discussion: The presence of D antigen variants was confirmed in 332 samples (69.3%), with an initial discrepancy in serological classification. In this group of discrepant samples, the frequency of weak RhD variants was 66% (219/332), that of extremely weak RhD was 28% (93/332), and that of partial RhD was 6% (20/332). The weak variants type 2 (27.4%), type 3 (8.4%), type 48 (8.4%), and type 1 (8.1%) were the next most prevalent variants after RHD*DEL43 (28%). The ccEe (R2r) phenotype was the most frequently detected (38.4%) and is present in 87% of the RHD*DEL43 samples. The E antigen is associated with the presence of this variant. Our analyses give the first description of D antigen variants in Chile. The most common variants are DEL type (RHD*DEL43) and weak (weak type 2), which are linked to the ccDEe (R2r) phenotype. These findings allow us to characterize the variants of the D antigen in Chile and, according to the obtained data, to design strategies for the management of donors, patients, and pregnant women.


Assuntos
Sistema do Grupo Sanguíneo Rh-Hr , Feminino , Humanos , Gravidez , Chile , Genótipo , Soros Imunes , Fenótipo , Reação em Cadeia da Polimerase , Sistema do Grupo Sanguíneo Rh-Hr/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA