Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Mikrochim Acta ; 190(2): 77, 2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36715890

RESUMO

Recently, electrochemiluminescent (ECL) immunosensors have received much attention in the field of biomarker detection. Here, a highly enhanced ECL immunosensing platform was designed for ultrasensitive detection of carcinoembryonic antigen (CEA). The surface of the glassy carbon electrode was enhanced by applying functional nanostructures such as thiolated graphene oxide (S-GO) and streptavidin-coated gold nanoparticles (SA-AuNPs). The selectivity and sensitivity of the designed immunosensor were improved by entrapping CEA biomolecules using a sandwich approach. Luminol/silver nanoparticles (Lu-SNPs) were applied as the main core of the signaling probe, which were then coated with streptavidin to provide overloading of the secondary antibody. The highly ECL signal enhancement was obtained due to the presence of horseradish peroxidase (HRP) in the signaling probe, in which the presence of H2O2 further amplified the intensity of the signals. The engineered immunosensor presented excellent sensitivity for CEA detection, with limit of detection (LOD) and linear detection range (LDR) values of 58 fg mL-1 and 0.1 pg mL-1 to 5 pg mL-1 (R2 = 0.9944), respectively. Besides its sensitivity, the fabricated ECL immunosensor presented outstanding selectivity for the detection of CEA in the presence of various similar agents. Additionally, the developed immunosensor showed an appropriate repeatability (RSD 3.8%) and proper stability (2 weeks). Having indicated a robust performance in the real human serum with stated LOD and LDR, the engineered immunosensor can be considered for the detection and monitoring of CEA in the clinic.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanocompostos , Humanos , Luminol/química , Antígeno Carcinoembrionário , Ouro/química , Prata/química , Nanopartículas Metálicas/química , Peróxido de Hidrogênio , Estreptavidina , Medições Luminescentes , Imunoensaio , Nanocompostos/química
2.
Mikrochim Acta ; 187(1): 25, 2019 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811449

RESUMO

The detection of thrombin by using CdS nanocrystals (CdS NCs), gold nanoparticles (AuNPs) and luminol is investigated in this work. Thrombin is detected by three methods. One is called the quenching method. It is based on the quenching effect of AuNPs on the yellow fluorescence of CdS NCs (with excitation/emission wavelengths of 355/550 nm) when placed adjacent to CdS NCs. The second method (called amplification method) is based on an amplification mechanism in which the plasmonics on the AuNPs enhance the emission of CdS NCs through distance related Förster resonance energy transfer (FRET). The third method is ratiometric and based on the emission by two luminophores, viz. CdS NCs and luminol. In this method, by increasing the concentration of thrombin, the intensity of CdS NCs decreases, while that of luminol increases. The results showed that ratiometric method was most sensitive (with an LOD of 500 fg.mL-1), followed by the amplification method (6.5 pg.mL-1) and the quenching method (92 pg.mL-1). Hence, the latter is less useful. Graphical abstract Schematic representation of three different methods (quenching, amplification and ratiometric) were applied for detection of thrombin via aptasensor. The CdS nanocrystals, streptavidin (Str) coated AuNPs and also Str-luminol coated AuNPs were used for the construction steps of the electrochemiluminescence (ECL)-based biosensor.


Assuntos
Aptâmeros de Nucleotídeos/metabolismo , Técnicas Biossensoriais/métodos , Compostos de Cádmio/química , Pontos Quânticos/química , Sulfetos/química , Trombina/análise , Aptâmeros de Nucleotídeos/genética , Sequência de Bases , Eletroquímica , Eletrodos , Peróxido de Hidrogênio/química , Concentração de Íons de Hidrogênio , Medições Luminescentes , Trombina/metabolismo
3.
Mikrochim Acta ; 185(9): 434, 2018 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-30159750

RESUMO

Caspase-3 plays a vital role in intrinsic and extrinsic pathways of programed cell death and in cell proliferation. Its detection is an important tool for early detection of some cancers and apoptosis-related diseases, and for monitoring the efficacy of pharmaceuticals and of chemo- and radiotherapy of cancers. This review (with 72 references) summarizes nanomaterial based methods for signal amplification in optical methods for the determination of caspase-3 activity. Following an introduction into the field, a first large section covers optical assays, with subsections on luminescent and chemiluminescence, fluorometric (including FRET based), and colorimetric assays. Further section summarize methods for bioimaging of caspase-3. A concluding section covers current challenges and future perspectives. Graphical Abstract ᅟ.


Assuntos
Apoptose , Técnicas Biossensoriais/métodos , Caspase 3/metabolismo , Imagem Molecular/métodos , Nanoestruturas , Nanotecnologia/métodos , Humanos
4.
Biomolecules ; 13(8)2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37627295

RESUMO

Diabetes affects the structure of the blood vessel walls. Since the blood vessel walls are made of birefringent organized tissue, any change or damage to this organization can be evaluated using polarization-sensitive optical coherence tomography (PS-OCT). In this paper, we used PS-OCT along with the blood vessel wall birefringence index (BBI = thickness/birefringence2) to non-invasively assess the structural integrity of the human retinal blood vessel walls in patients with diabetes and compared the results to those of healthy subjects. PS-OCT measurements revealed that blood vessel walls of diabetic patients exhibit a much higher birefringence while having the same wall thickness and therefore lower BBI values. Applying BBI to diagnose diabetes demonstrated high accuracy (93%), sensitivity (93%) and specificity (93%). PS-OCT measurements can quantify small changes in the polarization properties of retinal vessel walls associated with diabetes, which provides researchers with a new imaging tool to determine the effects of exercise, medication, and alternative diets on the development of diabetes.


Assuntos
Diabetes Mellitus , Tomografia de Coerência Óptica , Humanos , Vasos Retinianos/diagnóstico por imagem , Retina/diagnóstico por imagem , Diabetes Mellitus/diagnóstico por imagem , Exercício Físico
5.
J Biomed Opt ; 28(12): 126001, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38074217

RESUMO

Significance: Post-burn scars and scar contractures present significant challenges in burn injury management, necessitating accurate evaluation of the wound healing process to prevent or minimize complications. Non-invasive and accurate assessment of burn scar vascularity can offer valuable insights for evaluations of wound healing. Optical coherence tomography (OCT) and OCT angiography (OCTA) are promising imaging techniques that may enhance patient-centered care and satisfaction by providing detailed analyses of the healing process. Aim: Our study investigates the capabilities of OCT and OCTA for acquiring information on blood vessels in burn scars and evaluates the feasibility of utilizing this information to assess burn scars. Approach: Healthy skin and neighboring scar data from nine burn patients were obtained using OCT and processed with speckle decorrelation, Doppler OCT, and an enhanced technique based on joint spectral and time domain OCT. These methods facilitated the assessment of vascular structure and blood flow velocity in both healthy skin and scar tissues. Analyzing these parameters allowed for objective comparisons between normal skin and burn scars. Results: Our study found that blood vessel distribution in burn scars significantly differs from that in healthy skin. Burn scars exhibit increased vascularization, featuring less uniformity and lacking the intricate branching network found in healthy tissue. Specifically, the density of the vessels in burn scars is 67% higher than in healthy tissue, while axial flow velocity in burn scar vessels is 25% faster than in healthy tissue. Conclusions: Our research demonstrates the feasibility of OCT and OCTA as burn scar assessment tools. By implementing these technologies, we can distinguish between scar and healthy tissue based on its vascular structure, providing evidence of their practicality in evaluating burn scar severity and progression.


Assuntos
Cicatriz , Tomografia de Coerência Óptica , Humanos , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Tomografia de Coerência Óptica/métodos , Pele/irrigação sanguínea , Cicatrização , Neovascularização Patológica/patologia
6.
Biomed Opt Express ; 12(7): 4340-4362, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34457418

RESUMO

A new method based on polarization-sensitive optical coherence tomography (PS-OCT) is introduced to determine the polarization properties of human retinal vessel walls, in vivo. Measurements were obtained near the optic nerve head of three healthy human subjects. The double pass phase retardation per unit depth (DPPR/UD), which is proportional to the birefringence, is higher in artery walls, presumably because of the presence of muscle tissue. Measurements in surrounding retinal nerve fiber layer tissue yielded lower DPPR/UD values, suggesting that the retinal vessel wall tissue near the optic nerve is not covered by retinal nerve fiber layer tissue (0.43°/µm vs. 0.77°/µm, respectively). Measurements were obtained from multiple artery-vein pairs, to quantify the different polarization properties. Measurements were taken along a section of the vessel wall, with changes in DPPR/UD up to 15%, while the vessel wall thickness remained relatively constant. A stationary scan pattern was applied to determine the influence of involuntary eye motion on the measurement, which was significant. Measurements were also analyzed by two examiners, with high inter-observer agreement. The measurement repeatability was determined with measurements that were acquired during multiple visits. An improvement in accuracy can be achieved with an ultra-broad-bandwidth PS-OCT system since it will provide more data points in-depth, which reduces the influence of discretization and helps to facilitate better fitting of the birefringence data.

7.
Biosens Bioelectron ; 141: 111439, 2019 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-31247453

RESUMO

Carcinoembryonic antigen (CEA) is an important oncomarker for the detection of breast cancer. For ultra-sensitive sensing of CEA with great specificity and accuracy, an innovative and reliable electrochemical immunosensor was developed using various nano-hybrids. A glassy carbon electrode (GC) was modified with thiolated graphene oxide (T-GO) to elevate the active surface area of the electrode. The streptavidin-coated gold nanoparticles (AuNPs) were used to increase the conductivity of the sensing area as well as the loading capacity of the biotinylated monoclonal antibody (mAb). A sandwich-on approach was developed to reach a low limit of detection (LOD). The biotinylated mAb, streptavidin coated silver nanoparticles (AgNPs) and horseradish peroxidase (HRP), altogether, formed the signaling probe of the proposed immunosensor. The electrochemical signal was significantly enhanced in the presence of hydroquinone (HQ) and hydrogen peroxide (H2O2). Under the optimized conditions, the proposed immunosensor presented an excellent performance in a linear range of 100 fg/mL to 5 pg/mL with a low detection limit of 75 fg/mL. The engineered immunosensor displayed excellent specificity for the detection of CEA even in the real human serum, upon which it is proposed for the early detection and monitoring of CEA in the clinic.


Assuntos
Técnicas Biossensoriais/métodos , Antígeno Carcinoembrionário/sangue , Ouro/química , Nanopartículas Metálicas/química , Prata/química , Anticorpos Imobilizados/química , Técnicas Eletroquímicas/métodos , Grafite/química , Humanos , Imunoensaio/métodos , Limite de Detecção , Nanopartículas Metálicas/ultraestrutura
8.
Mater Sci Eng C Mater Biol Appl ; 65: 97-108, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27157732

RESUMO

In this report, for the first time, the non-modified glassy carbon electrode was used for detection of cardiovascular drug interaction with bovine serum albumin (BSA). These interactions were tested at physiological conditions (T=37°C and pH=7.4 phosphate buffer solution) in different incubation times (0-4h) by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The applications of DPV for quantitative investigation of some cardiovascular drug interaction with BSA (as a model of serum albumin proteins) were discussed. The herein described approach is expected to promote the exploitation of electrochemically-based methods for the study of drug-serum albumin protein interaction which is necessary in biochemical and biosensing studies. This report may open a new window to application of electrochemical sensors towards interactions of cardiovascular drugs with BSA and human serum albumin (HAS) in the near future.


Assuntos
Fármacos Cardiovasculares/química , Técnicas Eletroquímicas , Soroalbumina Bovina/química , Animais , Carbono/química , Fármacos Cardiovasculares/metabolismo , Bovinos , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Ligação Proteica , Albumina Sérica/química , Albumina Sérica/metabolismo , Soroalbumina Bovina/metabolismo , Temperatura
9.
J Photochem Photobiol B ; 161: 456-62, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27318602

RESUMO

In this experimental study, cancer and normal cells behavior during an in vitro photodynamic therapy (PDT) under exposure of continuous wave (CW) and fractionated mode of laser with different irradiation power and time intervals was compared and investigated. At the first, human fibroblast cancer cell line (SW 872) and human dermal normal (HFFF2) cell line were incubated with different concentrations of zinc phthalocyanine (ZnPc), as a PDT drug. The cells, then, were irradiated with a 675nm diode laser and the cell viability was evaluated using MTT assay. Under optimized conditions, the viability of the cancer cells was eventually reduced to 3.23% and 13.17%, and that of normal cells was decreased to 20.83% and 36.23% using CW and fractionated diode lasers, respectively. In general, the ratio of ZnPc LD50 values for the normal cells to the cancer cells with CW laser was much higher than that of the fractionated laser. Subsequently, cancer cells in comparison with normal ones were found to be more sensitive toward the photodynamic damage induced by ZnPc. In addition, treatment with CW laser was found to be more effective against the cancer cells with a lower toxicity to the normal cells compared with the fractionated diode laser.


Assuntos
Apoptose/efeitos dos fármacos , Indóis/toxicidade , Lasers Semicondutores , Compostos Organometálicos/toxicidade , Fármacos Fotossensibilizantes/toxicidade , Linhagem Celular , Sobrevivência Celular/efeitos dos fármacos , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/efeitos da radiação , Humanos , Indóis/química , Indóis/uso terapêutico , Isoindóis , Neoplasias/tratamento farmacológico , Neoplasias/metabolismo , Neoplasias/patologia , Compostos Organometálicos/química , Compostos Organometálicos/uso terapêutico , Fotoquimioterapia , Fármacos Fotossensibilizantes/química , Fármacos Fotossensibilizantes/uso terapêutico , Compostos de Zinco
10.
Bioimpacts ; 6(3): 135-147, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27853677

RESUMO

Introduction: Growing demands for ultrasensitive biosensing have led to the development of numerous signal amplification strategies. In this report, a novel electrochemiluminescence (ECL) method was developed for the detection and determination of caspase-3 activity based on reduced graphene oxide sheets decorated by gold nanoparticles as signal amplification element and horseradish peroxidase enzyme (HRP) as ECL intensity enhancing agent. Methods: The ECL intensity of the luminol was improved by using the streptavidin coated magnetic beads and HRP in the presence of hydrogen peroxide. The cleavage behavior of caspase-3 was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using biotinylated peptide (DEVD containing peptide) which was coated on reduced graphene oxide decorated with gold nanoparticle. The surface modification of graphene oxide was successfully confirmed by FTIR, UV-vis and x-ray spectroscopy. Results: ECL based biosensor showed that the linear dynamic range (LDR) and the lower limit of quantification (LLOQ) were 0.5-100 and 0.5 femtomolar (fM), respectively. Finally, the performance of the engineered peptide based biosensor was validated in the A549 cell line as real samples. Conclusion: The prepared peptide based biosensor could be considered as an excellent candidate for early detection of apoptosis, cell turnover, and cancer related diseases.

11.
Biosens Bioelectron ; 80: 146-153, 2016 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-26827144

RESUMO

A simple, rapid response time and ultrahigh sensitive electrochemiluminescence (ECL) immunosensor based on Ru(bpy)3(2+)doped silica doped AuNPs (Ru-Si@Au nanocomposite) was developed for detection of p53 protein, a well-known tumor suppressor. The immunosensor was constructed using biotinylated capture antibody, immobilized on the glassy carbon electrode (GCE) using streptavidin modified-gold nanoparticles/thiolated graphene oxide, followed by its conjugation with the Ru-silica@Au nanocomposite labeled secondary antibody to form a sandwich-type immunocomplex. The use of Ru-Si@Au nanocomposites led to a remarkable increase in the ECL intensity and, thus, the sensitivity of the method. Under the optimized conditions, the linear range of the proposed p53 immunosensor was found between 0.2 and 200 pM with a calculated limit of detection of 22.8 fM. The selectivity and reproducibility of the immunosensor was also investigated and the results showed high specificity and great stability in detecting of p53. Moreover, the ECL immunosensor was successfully applied for quantification of p53 protein in the human spiked serum samples and more importantly in the human normal and cancer skin fibroblast cells showing much satisfactory result compared with the ELISA method. The proposed immunosensor reported herein offers a considerable potential in early detection of cancer and clinical diagnosis and provides a new platform for biomarker detection.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Neoplasias/sangue , Proteína Supressora de Tumor p53/isolamento & purificação , Fibroblastos/química , Ouro/química , Grafite/química , Humanos , Imunoensaio/métodos , Limite de Detecção , Nanopartículas Metálicas/química , Neoplasias/patologia , Dióxido de Silício/química , Proteína Supressora de Tumor p53/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA