Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 75(1): 99-108.e2, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34425192

RESUMO

OBJECTIVE: A crucial step in designing fenestrated stent grafts for treatment of complex aortic abdominal aneurysms is the accurate positioning of the fenestrations. The deployment of a fenestrated stent graft prototype in a patient-specific rigid aortic model can be used for design verification in vitro, but is time and human resources consuming. Numerical simulation (NS) of fenestrated stent graft deployment using the finite element analysis has recently been developed; the aim of this study was to compare the accuracy of fenestration positioning by NS and in vitro. METHODS: All consecutive cases of complex aortic abdominal aneurysm treated with the Fenestrated Anaconda (Terumo Aortic) in six European centers were included in a prospective, observational study. To compare fenestration positioning, the distance from the center of the fenestration to the proximal end of the stent graft (L) and the angular distance from the 0° position (C) were measured and compared between in vitro testing (L1, C1) and NS (L2, C2). The primary hypothesis was that ΔL (|L2 - L1|) and ΔC (|C2 - C1|) would be 2.5 or less mm in more than 80% of the cases. The duration of both processes was also compared. RESULTS: Between May 2018 and January 2019, 50 patients with complex aortic abdominal aneurysms received a fenestrated stent graft with a total of 176 fenestrations. The ΔL and ΔC was 2.5 mm or less for 173 (98%) and 174 (99%) fenestrations, respectively. The NS process duration was significantly shorter than the in vitro (2.1 days [range, 1.0-5.2 days] vs 20.6 days [range, 9-82 days]; P < .001). CONCLUSIONS: Positioning of fenestrations using NS is as accurate as in vitro and could significantly decrease delivery time of fenestrated stent grafts.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Modelos Cardiovasculares , Complicações Pós-Operatórias/epidemiologia , Stents/efeitos adversos , Aorta Abdominal/anatomia & histologia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Simulação por Computador , Humanos , Modelos Anatômicos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento
2.
Eur J Vasc Endovasc Surg ; 59(2): 237-246, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31865026

RESUMO

OBJECTIVE: The aim was to validate a computational patient specific model of Zenith® fenestrated device deployment in abdominal aortic aneurysms to predict fenestration positions. METHODS: This was a retrospective analysis of the accuracy of numerical simulation for fenestrated stent graft sizing. Finite element computational simulation was performed in 51 consecutive patients that underwent successful endovascular repair with Zenith® fenestrated stent grafts in two vascular surgery units with a high volume of aortic procedures. Longitudinal and rotational clock positions of fenestrations were measured on the simulated models. These measurements were compared with those obtained by (i) an independent observer on the post-operative computed tomography (CT) scan and (ii) by the stent graft manufacturer planning team on the pre-operative CT scan. (iii) Pre- and post-operative positions were also compared. Longitudinal distance and clock face discrepancies >3 mm and 15°, respectively, were considered significant. Reproducibility was assessed using Bland-Altman and linear regression analysis. RESULTS: A total of 195 target arteries were analysed. Both Bland-Altman and linear regression showed good reproducibility between the three measurement techniques performed. The median absolute difference between the simulation and post-operative CT scan was 1.0 ± 1.1 mm for longitudinal distance measurements and 6.9 ± 6.1° for clock positions. The median absolute difference between the planning centre and post-operative CT scan was 0.8 ± 0.8 mm for longitudinal distance measurements and 5.1 ± 5.0° for clock positions. Finally, the median absolute difference between the simulation and the planning centre was 0.96 ± 0.97 mm for longitudinal distance measurements and 4.8 ± 3.6° for clock positions. CONCLUSION: The numerical model of deployed fenestrated stent grafts is accurate for planning position of fenestrations. It has been validated in 51 patients, for whom fenestration locations were similar to the sizing performed by physicians and the planning centre.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Modelagem Computacional Específica para o Paciente , Stents , Aorta/diagnóstico por imagem , Aortografia/métodos , Procedimentos Endovasculares/métodos , Humanos , Período Pós-Operatório , Período Pré-Operatório , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
4.
Ann Vasc Surg ; 57: 91-97, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30500648

RESUMO

BACKGROUND: The purpose of this study was to report our experience of treatment of aortic aneurysms using combination of renal and visceral arteries bypasses and fenestrated/branched stent graft in various complex anatomical situations. METHODS: Between November 2005 and March 2017, 10 patients underwent a hybrid strategy combining bypasses for renal and/or visceral arteries and custom-made fenestrated/branched stent grafts. Two patients had abdominal aortic aneurysm (1 juxtarenal and 1 suprarenal), and 8 patients had thoracoabdominal aortic aneurysm (1 type I, 2 type II including one dissection, 2 type III, 1 type IV, and 2 type V). In total, 37 renal and visceral arteries were targeted, of which 23 were treated using fenestrated or branched stent graft and 14 were treated by bypass (11 to renal artery and 3 to celiac trunk). RESULTS: Technical success was 100%, and no patient died during a mean follow-up of 24.3 ± 21 months. Six patients had 7 postoperative complications after bypass surgery, and 3 patients had 3 complications after fenestrated or branched endovascular aneurysm repair (FEVAR/BEVAR) procedure. Seven reinterventions were performed in 3 patients. No occlusion of target vessels occurred. Renal function was stable during follow-up in all patients except one who developed end-stage renal failure requiring permanent dialysis. On the last follow-up computed tomography scan, aneurysm diameter decreased for 6 patients, was stable for 3 patients, and increased for one patient, in which persistent type II endoleak was observed. Aneurysm exclusion was complete in the remaining 9 patients. CONCLUSIONS: Combination of FEVAR/BEVAR procedures with renal and/or visceral artery bypass in patients with complex aortic aneurysms is feasible with acceptable results. Morbidity associated with bypass surgery has to be carefully balanced with the risk of catheterization difficulties in the setting of adverse anatomical features of the visceral/renal arteries or the aorta.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Artéria Renal/cirurgia , Stents , Vísceras/irrigação sanguínea , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , França , Humanos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
J Vasc Surg ; 67(2): 468-477, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28826728

RESUMO

OBJECTIVE: The objective of this study was to evaluate the early and long-term outcome of cryopreserved arterial allografts (CAAs) used for in situ reconstruction of abdominal aortic native or secondary graft infection and to identify predictors of mortality. METHODS: We retrospectively included 71 patients (mean age, 65.2 years [range, 41-84 years]; men, 91.5%) treated for abdominal aortic native or secondary graft infection (65 prosthetic graft infections; 16 of them had secondary aortoenteric fistula, 2 venous graft infections, and 4 mycotic aneurysms) by in situ reconstruction with CAA in the university hospitals of Clermont-Ferrand and Saint-Etienne from 2000 to 2016. The cryopreservation protocol was identical in both centers (-140°C). Early (<30 days) and late (>30 days) mortality and morbidity, reinfection, and CAA patency were assessed. Computed tomography was performed in all survivors. Survival was analyzed with the Kaplan-Meier method. Univariate analyses were performed with the log-rank test and multivariate analysis with the Cox regression model. RESULTS: Mean follow-up was 45 months (0-196 months). Early postoperative mortality rate was 16.9% (11/71). Early postoperative CAA-related mortality rate was 2.8% (2/71); both patients died of proximal anastomotic rupture on postoperative days 4 and 15. Early CAA-related reintervention rate was 5.6% (4/71); all had an anastomotic rupture, and two were lethal. Early postoperative reintervention rate was 15.5% (11/71). Intraoperative bacteriologic samples were positive in 56.3%, and 31% had a sole microorganism. Escherichia coli was more frequently identified in the secondary aortoenteric fistula and Staphylococcus epidermidis in the infected prosthesis. Late CAA-related mortality rate was 2.8%: septic shock at 2 months in one patient and proximal anastomosis rupture at 1 year in one patient. Survival at 1 year, 3 years, and 5 years was 75%, 64%, and 54%, respectively. Multivariate analysis identified type 1 diabetes (hazard ratio, 2.49; 95% confidence interval, 1.05-5.88; P = .04) and American Society of Anesthesiologists class 4 (hazard ratio, 2.65; 95% confidence interval, 1.07-6.53; P = .035) as predictors of mortality after in situ CAA reconstruction. Reinfection rate was 4% (3/71). Late CAA-related reintervention rate was 12.7% (9/71): proximal anastomotic rupture in one, CAA branch stenosis/thrombosis in five, ureteral-CAA branch fistula in one, and distal anastomosis false aneurysm in two. Primary patency at 1 year, 3 years, and 5 years was 100%, 93%, and 93%, respectively. Assisted primary patency at 1 year, 3 years, and 5 years was 100%, 96%, and 96%, respectively. No aneurysm or dilation was observed. CONCLUSIONS: The prognosis of native or secondary aortic graft infections is poor. Aortic in situ reconstruction with CAA offers acceptable early and late results. Patients with type 1 diabetes and American Society of Anesthesiologists class 4 are at higher risk of mortality.


Assuntos
Aneurisma Infectado/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Artérias/transplante , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Criopreservação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Infecções Relacionadas à Prótese/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aloenxertos , Aneurisma Infectado/diagnóstico , Aneurisma Infectado/microbiologia , Aneurisma Infectado/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/microbiologia , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Remoção de Dispositivo , Procedimentos Endovasculares/mortalidade , Feminino , França , Hospitais Universitários , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/mortalidade , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
6.
Pediatr Nephrol ; 32(10): 1935-1940, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28429121

RESUMO

BACKGROUND: This study describes the long-term results of renal autotransplantation for renovascular hypertension performed in children who are now 21 years of age or older. METHODS: Sixteen children (4 boys, 12 girls) with a mean age of 11.2 years at the time of the procedure underwent ex-vivo surgery at the university hospital of Saint-Etienne between 1992 and 2008. Acetylsalicylic acid was used for antiplatelet therapy in the postoperative period, without routine anticoagulation. The mean follow-up period was 15 years. The clinical course of these patients was retrospectively reviewed in adulthood and the results analyzed. RESULTS: The children were treated with a mean of 2.37 drugs per patient, and the mean preoperative blood pressure of the entire patient population was 151/89 mmHg. Mean preoperative creatinine clearance was 80 ml/min/1.73 m2. There was no postoperative death. One patient experienced a thrombosis immediately after the surgery, leading to a redo surgery. In this patient diuresis was restarted, but without efficient concentration and filtration, ultimately leading the patient to have a renal transplant after 1 year. At the end of the follow-up period, eight of the 16 patients (50%) were cured and the others were improved. At the last follow-up the mean blood pressure was 127/70 mmHg, and the mean number of drugs per patient was 0.68. The mean creatinine clearance at last follow-up was 104.3 ml/min/1.73 m2. Three patients had secondary procedures, with two undergoing percutaneous angioplasty (at postoperative months 9 and 12, respectively) and one having an hepatorenal bypass at postoperative year 4. Primary patency was 12/16 (75%); primary assisted patency was 15/16 (94%); secondary patency was 16/16 (100%). CONCLUSION: This study shows that renal autotransplantation has good and stable long-term results and is an effective conservative strategy for treating renovascular hypertension in children, thus avoiding nephrectomy.


Assuntos
Hipertensão Renovascular/cirurgia , Complicações Pós-Operatórias/epidemiologia , Artéria Renal/transplante , Trombose/epidemiologia , Enxerto Vascular/efeitos adversos , Adolescente , Adulto , Criança , Quimioterapia Combinada/métodos , Feminino , Seguimentos , Taxa de Filtração Glomerular , Humanos , Hipertensão Renovascular/diagnóstico , Hipertensão Renovascular/etiologia , Hipertensão Renovascular/fisiopatologia , Rim/irrigação sanguínea , Rim/fisiopatologia , Masculino , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Período Pós-Operatório , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Trombose/etiologia , Trombose/prevenção & controle , Transplante Autólogo/efeitos adversos , Transplante Autólogo/métodos , Resultado do Tratamento , Enxerto Vascular/métodos , Grau de Desobstrução Vascular , Adulto Jovem
7.
Ann Vasc Surg ; 44: 245-252, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28479451

RESUMO

BACKGROUND: Kidney recipients are increasingly older with arterial disease and extended arterial calcifications. In a kidney transplantation population, the prognosis value of aortic and iliac calcifications remains poorly explored. We aimed to assess the impact of pretransplantation aortoiliac vascular calcifications on patients, grafts survival, and cardiovascular events. METHODS: This retrospective study included kidney transplantation patients from 2006 to 2012 for whom we had available presurgery abdominal computed tomography results (n = 100). We designed a score to quantify aortoiliac calcifications. Primary end points were patient and graft survival. Secondary end points were renal function and cardiovascular morbidity. Predictive performances of calcification score were assessed using area under receiver-operating characteristic curves. Patients were classified in quartiles depending on global calcium score value. RESULTS: The cumulated rate of death and graft loss was 13% with no significant differences for survival between quartiles. No significant difference was observed in renal function (P = 0.4). Seventeen cardiovascular events were registered with a significant correlation between calcium score elevation and need of cardiovascular surgery during the follow-up (P = 0.01). Global calcium score had a predictive value of 74.5% (95% confidence interval 0.62-0.87) with 71% sensitivity and 73% specificity. CONCLUSIONS: Aortoiliac calcifications do not decrease patient and graft survival. High calcium score predict cardiovascular events and procedures during the follow-up.


Assuntos
Doenças da Aorta/complicações , Artéria Ilíaca , Transplante de Rim , Calcificação Vascular/complicações , Idoso , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/mortalidade , Área Sob a Curva , Angiografia por Tomografia Computadorizada , Feminino , Sobrevivência de Enxerto , Humanos , Artéria Ilíaca/diagnóstico por imagem , Estimativa de Kaplan-Meier , Transplante de Rim/efeitos adversos , Transplante de Rim/mortalidade , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/mortalidade
8.
Ann Vasc Surg ; 43: 317.e5-317.e11, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28495541

RESUMO

An 81-year-old woman was referred for the treatment of a 79-mm-diameter short neck abdominal aortic aneurysm with highly tortuous iliac arteries. She was considered at high risk for open repair and not suitable for standard endovascular repair given the short length of the proximal neck. Delay for a manufactured custom-made fenestrated stent graft was too long given the diameter of the aneurysm. A flexible stent graft was preferred because of severe iliac tortuosity. Endovascular repair was performed using a physician-modified Anaconda stent graft with 1 fenestration for the left renal artery. The technique for device modification and implantation is described. Postoperative course was uneventful and 1-year computed tomography scan showed complete exclusion of the aneurysm sac and patent left renal artery.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/instrumentação , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Desenho de Prótese , Resultado do Tratamento
9.
Ann Vasc Surg ; 40: 1-9, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27575304

RESUMO

BACKGROUND: The purpose of this study was to define predictive factors of early renal impairment after fenestrated or branched endovascular aortic repair (FEVAR or BEVAR) for aortic aneurysm. METHODS: Eighty-two patients underwent FEVAR or BEVAR for aortic aneurysm from January 2008 to December 2014. The primary end point was postoperative renal impairment on day 15 (D15). Renal impairment was defined as a 25% decrease in the glomerular filtration rate (GFR) and a GFR < 60 mL/min/1.73 m2 according to the Risk Injury Failure Loss and End-Stage criteria. Univariate and multivariate analyses were used to determine variables associated with early postoperative renal impairment. RESULTS: Seventy-seven of the 82 patients had a creatinine level on D15 and were included in this study, including a total of 145 target renal arteries. A preoperative GFR < 60 mL/min/1.73 m2 was present in 16 (20.8%) patients. On D15, 8 (10.4%) patients had an early postoperative renal impairment and 21 (27.3%) patients had a GFR < 60 mL/min/1.73 m2. A single patient had immediate postoperative dialysis for 10 days. "Perirenal hematoma" and "preoperative renal length under 100 mm" were significantly associated with the occurrence of the renal impairment after mutual adjustment in multivariate analysis (P < 0.001 and P = 0.01). No significant association was found between preoperative renal insufficiency combining all stages or with a GFR < 60 mL/min/1.73 m2 and early renal impairment after surgery (P = 0.096 and P = 0.263). CONCLUSION: The presence of a reduced preoperative renal length and the postoperative occurrence of a perirenal hematoma are predictive factors of renal impairment on D15 for patients treated with FEVAR or BEVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Taxa de Filtração Glomerular , Rim/fisiopatologia , Insuficiência Renal/etiologia , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Feminino , França , Hematoma/etiologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Desenho de Prótese , Diálise Renal , Insuficiência Renal/diagnóstico , Insuficiência Renal/fisiopatologia , Insuficiência Renal/terapia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-38801398

RESUMO

AIMS: As transcatheter mitral valve (MV) interventions are expanding and more device types and sizes become available, a tool supporting operators in preprocedural planning and the clinical decision-making process is highly desirable. We sought to develop a finite element (FE) computational simulation model to predict results of transcatheter edge-to-edge (TEER) interventions. METHODS AND RESULTS: We prospectively enrolled patients with secondary mitral regurgitation (MR) referred for a clinically indicated TEER. Three-dimensional (3D) transesophageal echocardiograms performed at the beginning of the procedure were used to perform the simulation. On the 3D dynamic model of the MV that was first obtained, we simulated the clip implantation using the same clip(s) type, size, number, and implantation location that was used during the intervention. The 3D model of the MV obtained after simulation of the clip implantation was compared to the clinical results obtained at the end of the intervention. We analyzed the degree and location of residual MR and the shape and area of the diastolic mitral valve area. We performed computational simulation on 5 patients. Overall, the simulated models predicted well the degree and location of the residual regurgitant orifice(s) but tended to underestimate the diastolic mitral orifice area. CONCLUSIONS: In this proof-of-concept study, we present preliminary results on our algorithm simulating clip implantation in 5 patients with functional MR. We show promising results regarding the feasibility and accuracy in terms of predicting residual MR and the need to improve the estimation of the diastolic mitral valve area.

11.
J Endovasc Ther ; 20(4): 523-35, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23914862

RESUMO

PURPOSE: To assess numerically the flexibility and mechanical stresses undergone by stents and fabric of currently manufactured stent-grafts. METHODS: Eight marketed stent-graft limbs (Aorfix, Anaconda, Endurant, Excluder, Talent, Zenith Flex, Zenith LP, and Zenith Spiral-Z) were modeled using finite element analysis. A numerical benchmark combining bending up to 180° and pressurization at 150 mmHg of the stent-grafts was performed. Stent-graft flexibility, assessed by the calculation of the luminal reduction rate, maximal stresses in stents, and maximal strains in fabric were assessed. RESULTS: The luminal reduction rate at 90° was <20% except for the Talent stent-graft. The rate at 180° was higher for Z-stented models (Talent, Endurant, Zenith, and Zenith LP; range 39%-78%) than spiral (Aorfix, Excluder, and Zenith Spiral-Z) or circular-stented (Anaconda) devices (range 14%-26%). At 180°, maximal stress was higher for Z-stented stent-grafts (range 370-622 MPa) than spiral or circular-stented endografts (range 177-368 MPa). At 90° and 180°, strains in fabric were low and did not differ significantly among the polyester stent-grafts (range 0.5%-7%), while the expanded polytetrafluoroethylene fabric of the Excluder stent-graft underwent higher strains (range 11%-18%). CONCLUSION: Stent design strongly influences mechanical performances of aortic stent-grafts. Spiral and circular stents provide greater flexibility, as well as lower stress values than Z-stents, and thus better durability.


Assuntos
Prótese Vascular , Análise de Elementos Finitos , Stents , Aneurisma da Aorta Abdominal/cirurgia , Fenômenos Mecânicos , Desenho de Prótese
12.
Ann Vasc Surg ; 27(2): 131-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23380549

RESUMO

BACKGROUND: The purpose of this study was to evaluate short-term results of endovascular treatment of common iliac artery (CIA) aneurysms without a distal neck by using iliac branch devices (IBDs), which enable maintenance of antegrade perfusion to the internal iliac artery (IIA). METHODS: Our investigation was done in a prospective, multicenter, nonrandomized manner. IBD were implanted to exclude CIA aneurysms with a diameter >25 mm in patients unfit for open repair. The stent grafts were designed based on preoperative angio-CT findings. A covered stent implantation between the IBD and the target IIA was performed during the same surgical procedure. Angio-CT was performed within the 30 days after the procedure. From January 2009 to April 2010, 39 patients were included in our study (38 men and 1 woman, mean age 73 years). RESULTS: The CIA aneurysm (mean diameter 32.3 mm) was isolated in 15 patients and associated with an abdominal aorta aneurysm (mean diameter 66 mm) in 24 patients. The IBD was systematically connected to a bifurcated aortobiiliac stent graft. The bifurcated stent graft was implanted during the same procedure in all patients, except for two who had a bifurcated stent graft history. Median surgery time, fluoroscopy time, and volume of contrast product were 192 (range 90-360) minutes, 32 (10-120) minutes, and 150 (60-352) mL, respectively. In 37 patients (95%), the internal iliac branch was patent at the end of the surgery. In two patients (5%), it was occluded, entailing a subischemic colic episode and buttock claudication in one of them. To treat a type I endoleak, a proximal extension partially covering a renal artery was implanted during the same surgery. A type III endoleak was diagnosed on the postoperative angio-CT. In three patients, a cross-over femorofemoral bypass was performed for an external iliac leg thrombosis (and for an internal iliac branch thrombosis in one case). In all, at 30 days, no death was reported and the success rate was 90% (three leg stenoses and a type III endoleak). CONCLUSIONS: IBD implantation to maintain an antegrade internal iliac perfusion is possible and has shown promising early success. Our results can be compared with those in the published literature. A learning curve will be needed to improve the technical success rate.


Assuntos
Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , França , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Pessoa de Meia-Idade , Período Perioperatório , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Desenho de Prótese , Reoperação , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
13.
Ann Vasc Surg ; 26(6): 790-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22534262

RESUMO

BACKGROUND: Carotid angioplasty and stenting has been proposed as an alternative to carotid endarterectomy (CEA) in patients deemed as at high risk for this surgical procedure. To date, definitely accepted criteria to identify "high-risk" patients for CEA do not exist. Our objective was to assess the relevance of numerous supposed high-risk factors in our experience, as well as their possible effect on our early postoperative results. METHODS: A retrospective review of 1,033 consecutive CEAs performed during a 5.6-year period at a single institution was conducted (Vascular Surgery Department, St. Etienne University Hospital, France). Early results in terms of mortality and neurologic events were recorded. Univariate and multivariate analyses for early risk of stroke, myocardial infarction, and death were performed, considering the influence of age, sex, comorbidities, clinical symptoms, and anatomic features. RESULTS: The cumulative 30-day stroke and death rate was 1.2%. A total of 10 strokes occurred and resulted in three deaths. The postoperative stroke risk was significantly higher in the subgroup of patients treated for symptomatic carotid artery disease: 2,6% (P = 0,004). Univariate analysis and logistic regression did not show statistical significance for 30-day results in any of the considered variables. CONCLUSION: Patients with significant medical comorbidities, contralateral carotid occlusion, and high carotid lesions can undergo surgery without increased complications. Those parameters should not be used as exclusion criteria for CEA.


Assuntos
Artéria Carótida Interna/cirurgia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Hospitais Universitários/estatística & dados numéricos , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Estenose das Carótidas/mortalidade , Distribuição de Qui-Quadrado , Endarterectomia das Carótidas/mortalidade , Feminino , França , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Razão de Chances , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do Tratamento
14.
Ann Vasc Surg ; 26(2): 166-74, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22037143

RESUMO

BACKGROUND: To study the incidence, the types, and the results of secondary procedures performed after endovascular treatment of infrarenal abdominal aortic aneurysm (AAA). To compare the population of patients who underwent secondary procedure (P2) with the population of those who did not require it. MATERIAL AND METHODS: Between 1998 and 2008, this study included all the patients electively treated for AAA with stentgrafts that were still available on the market on January 1, 2009. Data were prospectively collected and retrospectively analyzed. The postoperative follow-up included at least a systematic computed tomography scan at 6, 12, 18, and 24 months and then every year. P2 were defined as any additionnal procedures performed to treat aneurysm related complications after initial stentgraft implantation. RESULTS: We studied 162 patients with a mean 40 ± 31 months' follow-up. In 32 patients (19.7%), there were 46 P2, 3 of them were surgical conversion and 1 with endovascular conversion. Thirty-nine P2 were scheduled, and seven were performed in emergency. Nine patients underwent more than one P2. P2 was indicated for type II endoleak in 17 cases, 13 of them with a diameter increase; for type I endoleak in 10 cases; for AAA rupture in 3 cases; for occlusion or stentgraft stenosis in 13 cases; and for 1 type III endoleak, 1 endotension, and 1 femoro-femoral crossover bypass infection. Two ruptures occurred in patients who had undergone P2. The immediate technical success was 89.1%. At 30 days, morbidity was 10.9%, and there was no mortality. Survival rates at 3 and 5 years were respectively 85.2% and 71.9% in patients with secondary procedure and 70.6% and 47.5% in the others (p = 0.046). CONCLUSIONS: In patients treated for AAA with second generation stentgrafts, in the long term, secondary procedure rate was 19.7%. Survival rate for patients who underwent a secondary procedure was better, which was probably related to the fact that they were younger at the time of stentgraft implantation. Large AAA diameter was a secondary-procedure risk factor.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/cirurgia , Procedimentos Endovasculares/instrumentação , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , França , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Front Med Technol ; 3: 704806, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35047943

RESUMO

Fenestrated Endovascular Aortic Repair, also known as FEVAR, is a minimally invasive procedure that allows surgeons to repair the aorta while still preserving blood flow to kidneys and other critical organs. Given the high complexity of FEVAR, there is a pressing need to develop numerical tools that can assist practitioners at the preoperative planning stage and during the intervention. The aim of the present study is to introduce and to assess an assistance solution named Fast Method for Virtual Stent-graft Deployment for computer assisted FEVAR. This solution, which relies on virtual reality, is based on a single intraoperative X-ray image. It is a hybrid method that includes the use of intraoperative images and a simplified mechanical model based on corotational beam elements. The method was verified on a phantom and validated on three clinical cases, including a case with fenestrations. More specifically, we quantified the errors induced by the different simplifications of the mechanical model, related to fabric simulation and aortic wall mechanical properties. Overall, all errors for both stent and fenestration positioning were less than 5 mm, making this method compatible with clinical expectations. More specifically, the errors related to fenestration positioning were less than 3 mm. Although requiring further validation with a higher number of test cases, our method could achieve an accuracy compatible with clinical specifications within limited calculation time, which is promising for future implementation in a clinical context.

16.
Ann Vasc Surg ; 24(5): 663-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20413255

RESUMO

BACKGROUND: To compare the outcome of endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with and without associated common iliac artery aneurysm (CIAA) extending to the iliac bifurcation. METHODS: Review of 157 patients who underwent endovascular aneurysm repair between 1999 and 2007. Group 1 included 133 patients with and without CIAA and suitable distal common iliac neck (type A, B, C, or D). Group 2 included 24 patients with associated CIAA extending to the iliac bifurcation (type E). Stent-grafts were Powerlink (Endologix, Irvine, CA) in 42, Zenith (Cook, Bjaeverskov, Danemark) in 55, and Talent (Medtronic, Sunnyvale, CA) in 60 patients. Forty patients had aorto-uni-iliac stent-grafts. RESULTS: No difference in overall mortality and AAA rupture was observed. AAA-related complication-free survival at 5 year was 72 +/- 5% and 41 +/- 14% in group 1 and 2, respectively (p = 0.006). Secondary intervention-free survival was 84 +/- 5% and 55 +/- 12% in group 1 and 2, respectively (p = 0.0008). Incidence of distal type 1 endoleak and stent-graft thrombosis was 17 and 8 % in group 2, 3.8 and 0.8 % in group 1, respectively (p = 0.07 and p = 0.01, respectively). CONCLUSION: AAA-related complications and secondary interventions occur more frequently in patients with type E AAA. Distal type 1 endoleak and stent-graft thrombosis are more frequent in these patients. These results warrant further development of technologies that are better adapted for treatment of CIAAs, such as branched and flexible stent-grafts.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Aneurisma Ilíaco/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/patologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , França , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Humanos , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/patologia , Estimativa de Kaplan-Meier , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Trombose/etiologia , Trombose/cirurgia , Fatores de Tempo , Resultado do Tratamento
17.
Ann Vasc Surg ; 24(3): 308-14, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20053527

RESUMO

BACKGROUND: The aim of this study was to evaluate the quality of the current treatment of patients presenting with ruptured abdominal aortic aneurysms (RAAAs), from the first symptoms to the operating room with an analysis of preoperative mortality risk factors. METHODS: For 3 years, in four vascular surgery departments, we have collected all the consecutive cases of patients operated on for RAAA. We analyzed the initial clinical situation, the means of transportation, the time elapsed before treatment, and the mortality rate at 3 days. Sixty-six RAAAs were operated on. Mean patient age was 76 years (range, 52-93 years). RESULTS: The initial symptoms were a precisely located pain either abdominal (45.3%), lumbar (17.2%), or both (14.1%) or feeling faint (10.9%). In 22.7% of the cases, an initial hemodynamic instability was observed. In 46.8% of the cases, patients first went to a peripheral hospital before being admitted into a referral centre. In 84.5% of the cases, medical mean of transportation was used. The mean distance covered was 59.8 kilometers (range, <5 km to 213 km). The initial diagnosis was accurate in 67.3% of the cases. The mean intrahospital waiting period between the arrival at a reference center and the admission into an operating room was 127 minutes. Global mortality rate was 44.2%. The main preoperative mortality factor to be noticed was the initial hemodynamic instability (p=0.0031). Among stable patients, only two of them (5.4%) worsened during the preoperative treatment. CONCLUSION: In our study, hemodynamic instability corresponds to the main prognosis factor of mortality. In most cases, the initial stability persisted and allowed additional evaluation. However, the intrahospital waiting periods appeared to be too long. To be optimal, the adequate treatment should be specifically designed as soon as a diagnosis has been established.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Ruptura Aórtica/terapia , Serviços Médicos de Emergência , Acessibilidade aos Serviços de Saúde , Hemodinâmica , Qualidade da Assistência à Saúde , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/diagnóstico , Ruptura Aórtica/mortalidade , Ruptura Aórtica/fisiopatologia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Distribuição de Qui-Quadrado , Feminino , França , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Encaminhamento e Consulta , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Transporte de Pacientes , Resultado do Tratamento
18.
Ann Vasc Surg ; 23(1): 49-59, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18973982

RESUMO

Usual imaging after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) consists of AAA diameter monitoring and endoleak detection. Among additional predictor parameters previously proposed to help clinicians in better identifying subgroups of AAA still at risk of rupture, AAA wall motion after EVAR has been studied, but its value was not clearly established. Tissue Doppler imaging (TDI) is an ultrasonographic modality which allows wall motion measurements along an arterial segment. The aim of the current study was to analyze AAA wall motion with TDI before and after EVAR and to describe its evolution in patients with more than 1 month of follow-up. Twenty-five consecutive patients undergoing EVAR between February 2005 and June 2007 gave informed consent to be prospectively investigated with the TDI system before EVAR and at each visit during follow-up. The mean (SD) follow-up was 13.7 (9.7) months. Maximum mean segmental dilation (MMSD), segmental compliance, dilation at maximum diameter, pressure strain elastic modulus (Ep), and stiffness were compared between three periods (before stenting, before discharge, and at last follow-up), and their relation with AAA diameter was analyzed. A significant decrease in AAA compliance was immediately observed after successful EVAR and remained stable during later follow-up. On the other hand, AAA diameter progressively decreased along time and was statistically lower at the last control compared to the initial value. MMSD, segmental compliance, and dilation at maximum diameter were positively related to AAA diameter. This means that the larger the AAA diameter after stenting, the higher the value for these parameters can be expected. On the contrary, percentage of AAA diameter decrease and percentage of MMSD decrease were not related after successful EVAR. There was no parallelism between loss in compliance and diameter decrease along time, and there is not a unique pattern of AAA diameter and compliance evolution after EVAR. Even if comparison between patients without and with endoleak was weak due to the small sample of the latter group (five patients with endoleak), compliance tended to be greater in case of endoleak. AAA wall motion after successful EVAR reflects complex interactions between all the components of the stented aneurysm which evolve over time, including true compliance of the aneurysm wall itself; intra-aneurysm sac pressure with possible different effects for peak, mean, and pulse pressures; remodeling of the thrombus; stiffness characteristics of the graft; and systemic pressure. Combining simultaneous MMSD records with actual intrasaccular pressure measurements in patients with and without endoleak would improve our understanding of the clinical pulsatility mechanism within AAA after EVAR.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Ultrassonografia Doppler , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Complacência (Medida de Distensibilidade) , Dilatação Patológica , Método Duplo-Cego , Módulo de Elasticidade , Feminino , Seguimentos , Humanos , Masculino , Valor Preditivo dos Testes , Pressão , Estudos Prospectivos , Falha de Prótese , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
19.
J Vasc Surg ; 48(4): 852-8, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18723311

RESUMO

BACKGROUND: To lower the risk of complications, carotid angioplasty and stenting (CAS) has been proposed as an alternative to open surgery for carotid artery stenosis after neck irradiation. However, there are little postoperative data to support the benefits of this strategy. This study evaluated the outcome of CAS in patients who had undergone neck irradiation. METHODS: This retrospective study was conducted at 15 vascular surgery or interventional radiology centers in France between January 1998 and July 2006. A total of 135 patients (115 men) with a mean age of 67 +/- 8 years (range, 43-88) underwent CAS for 149 irradiation-induced lesions. The interval between irradiation and discovery of the lesions was 12 +/- 8 years. Mean diameter reduction was 81% (range, 50%-95%), and stenosis was symptomatic in 34%. Contralateral carotid lesions were observed in 48% of patients, including thrombosis in 18 and stenosis >50% in 53. RESULTS: Technical failure occurred during CAS in three cases. The overall technical success rate was 98%. A cerebral protection device was used in 59%. No death, one transient ischemic attack, and two strokes occurred during the first postoperative month. Mean follow-up was 30 months. Six patients were lost to follow-up. Survival rates were 93.9% at 1 year and 75.3% at 3 years. Complications after the first postoperative month included neurologic events in six, carotid thrombosis in nine, and restenosis in 18. The rates of freedom from neurologic and anatomic events were, respectively, 96.2% and 93.2% at 1 year and 93.1% and 85.9% at 3 years. CONCLUSION: The immediate outcome of CAS for irradiation-induced carotid artery stenosis was satisfactory. Medium-term neurologic outcome was acceptable, but the incidence of anatomic events such as thrombosis and restenosis was high. A randomized study is needed to confirm that the outcome of the endovascular and surgical therapy is comparable in this indication.


Assuntos
Angioplastia , Estenose das Carótidas/etiologia , Estenose das Carótidas/cirurgia , Lesões por Radiação/etiologia , Lesões por Radiação/cirurgia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço , Complicações Pós-Operatórias/epidemiologia , Radioterapia/efeitos adversos , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA