RESUMO
BACKGROUND AND OBJECTIVES: Securing an adequate blood supply relies on accurate knowledge of blood donors and donation practices. As published evidence on Asian populations is sparse, this study aims to gather up-to-date information on blood donors and donation practices in Asia to assist planning and strategy development. MATERIALS AND METHODS: Ten blood collection agencies (BCAs) provided 12 months' data on donors who met eligibility criteria or were deferred, as well as details of their donation practices. Body mass index and blood volumes were calculated and analysed. RESULTS: Data on 9,599,613 donations and 154,834 deferrals from six national and four regional BCAs revealed varied donation eligibility and collection practices. Seven used haemoglobin (Hb) criteria below the World Health Organization anaemia threshold. Seven accepted donors weighing <50 kg. Data collection on the weight and height of donors and on deferrals was inconsistent, often not routine. Deferred donors appear to weigh less, with corresponding lower estimated blood volume. CONCLUSION: The diversity in eligibility criteria and donation practices reflects each BCA's strategy for balancing donor health with securing an adequate blood supply. Use of lower Hb criteria substantiate their appropriateness in Asia and indicate the need to define Hb reference intervals relevant to each population. We encourage routine gathering of donor weight and height data to enable blood volume estimation and local optimization of donation volumes. Blood volume estimation formulae specific for the Asian phenotype is needed. Information from this study would be useful for tailoring donation criteria of Asian donors around the world.
Assuntos
Doação de Sangue , Doadores de Sangue , Humanos , Hemoglobinas/análise , Índice de Massa Corporal , ÁsiaRESUMO
OBJECTIVES: To investigate the blood supply contribution of older donors in five Asia Pacific regions. BACKGROUND: Older people are often the largest blood user group. Thus, as the population ages blood supply needs increase. Minimum and maximum donation age criteria potentially constrain the size of the donor pool. MATERIALS AND METHODS: Haemoglobin values and demographic frequency analytics (sex, age and blood type) were analysed on blood donors aged 60 years or more, from Hong Kong, Indonesia, Japan, Singapore and South Korea over 12 months. RESULTS: Data on 434357 donations was analysed. ABO Rh(D) frequencies of older donors matched that of national frequencies. Older donors were a disproportionately smaller proportion of the total donor pool for each country. Indonesia was the only region with no maximum age limit. Median haemoglobin for older males ranged from 14.2 to 14.8 g/dl and for females 13.1 to 13.9 g/dl. The frequency of female donors was between 15% and 33% of older donors. Older donors had higher donation frequency and lower deferral rates. CONCLUSION: Older donors are loyal and regular donors but under-represented in all regions studied. They could help meet future blood supply needs, especially post-menopausal female donors. Studies including ferritin levels are needed to determine if upper age limits can be safely modified.
Assuntos
Doadores de Sangue , Hemoglobinas , Idoso , Feminino , Hemoglobinas/análise , Hong Kong , Humanos , Japão , Masculino , Pessoa de Meia-Idade , República da CoreiaRESUMO
BACKGROUND: Severe blood donor adverse events are rare, but due to their rarity studying them can be difficult. To get an accurate estimate of their frequency and rate in the donor population it may be necessary to combine donation data across countries. STUDY DESIGN AND METHODS: International blood collection organizations (BCOs) provided data on rare/severe donor reactions as well as denominator information for their donor populations from 2015 to 2017. Donor reactions were classified using standardized definitions. RESULTS: BCOs from six countries provided reaction data for more than 22 million donations. A total of 480 rare reactions were reported of which 76.7% were imputed as definite and 11% probable. Rates of rare reactions were higher in females and first-time donors. Systemic rare reactions were the most common reaction type, accounting for over three quarters of reactions reported. Of systemic reactions, vasovagal reactions with loss of consciousness and injury or off-site (n = 350) made up the majority and occurred 1.53 per 100,000 donations. For the 22.3% that were localized reactions, the majority of these were cellulitis (n = 71, 0.31 per 100,000 donations) followed by deep venous thrombosis (n = 21, 0.09 per 100,000 donations). CONCLUSION: Pulling together data from multiple BCOs across countries allows for a better understanding of rare reactions, such as vasovagal reaction with injury or cellulitis, and for generating a reliable incidence rate for air embolism or compartment syndrome. However, gaps remain due to missing elements such as unknown donor status or location of reaction.
Assuntos
Doadores de Sangue , Celulite (Flegmão)/etiologia , Síncope Vasovagal/etiologia , Trombose Venosa/etiologia , Adolescente , Adulto , Idoso , Remoção de Componentes Sanguíneos/efeitos adversos , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Adulto JovemRESUMO
BACKGROUND: Determination of blood donor hemoglobin (Hb) levels is a pre-requisite to ensure donor safety and blood product quality. We aimed to identify Hb measurement practices across blood donation services and to what extent differences associate with low-Hb deferral rates. METHODS: An online survey was performed among Biomedical Excellence for Safer Transfusion (BEST) Collaborative members, extended with published data. Multivariable negative-binomial regression models were built to estimate adjusted associations of minimum donation intervals, Hb cut-offs (high, ≥13.5 g/dL in men or ≥ 12.5 g/dL in women, vs. lower values), iron monitoring (yes/no), providing or prescribing iron supplementation (yes/no), post-versus pre-donation Hb measurement and geographical location (Asian vs. rest), with low-Hb deferral rates. RESULTS: Data were included from 38 blood services. Low-Hb deferral rates varied from 0.11% to 8.81% among men and 0.84% to 31.85% among women. Services with longer minimum donation intervals had significantly lower deferral rates among both women (rate ratio, RR 0.53, 95%CI 0.33-0.84) and men (RR 0.53, 95%CI 0.31-0.90). In women, iron supplementation was associated with lower Hb deferral rates (RR 0.47, 95%CI 0.23-0.94). Finally, being located in Asia was associated with higher low-Hb deferral rates; RR 9.10 (95%CI 3.89-21.27) for women and 6.76 (95%CI 2.45-18.68) for men. CONCLUSION: Differences in Hb measurement and eligibility criteria, particularly longer donation intervals and iron supplementation in women, are associated with variations in low-Hb deferral rates. These insights could help improve both blood donation service efficiency and donor care.
Assuntos
Doadores de Sangue/estatística & dados numéricos , Hemoglobinas/metabolismo , Transfusão de Sangue/métodos , Seleção do Doador , Feminino , Testes Hematológicos , Humanos , Ferro/metabolismo , Inquéritos e Questionários , Fatores de TempoRESUMO
OBJECTIVES: To understand the worldwide scope of RBC crossmatching and issuing practices and measure efficiency using a novel quality indicator, the crossmatch/issue (C/I) ratio. METHODS: An electronic survey was disseminated to hospital transfusion services collecting details about RBC crossmatching and issuing practices. Respondents were asked to enumerate the number of RBCs crossmatched and issued at their institutions during the 2014 calendar year to calculate the C/I ratio. RESULTS: Fifty-two survey responses were received, mostly from North American transfusion services (28/52, 54%). The electronic crossmatch was the most common technique (n = 29), and most respondents performed the crossmatch at the time that an order for RBCs was received in the transfusion service (even if an order to issue the RBCs was not received). Data to calculate the C/I ratio were supplied by 22 respondents, and the mean ± SD was 1.30 ± 0.34. There was no difference in C/I ratios between services that use the electronic or serologic crossmatch techniques (P = .49). The ratio was the same at the four sites that crossmatch RBCs at the time of issue compared with the time of order receipt (mean ± SD, 1.11 ± 0.09 vs. 1.35 ± 0.36, respectively; P = .19). CONCLUSIONS: Electronic crossmatching is common, and the C/I ratio can be an indicator of efficiency.