Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiothorac Vasc Anesth ; 35(6): 1654-1662, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33431273

RESUMO

OBJECTIVE: Determine whether the intraoperative three-dimensional left ventricular outflow tract cross-sectional area may be inversely correlated with pressure gradients as a determinant of surgical success after septal myectomy in hypertrophic cardiomyopathy patients. DESIGN: Perioperative data were obtained by retrospective review. SETTING: Toronto General Hospital, University of Toronto, Toronto, Canada, a tertiary hospital. PARTICIPANTS: The study comprised 67 patients with hypertrophic obstructive cardiomyopathy. INTERVENTIONS: Transthoracic and intraoperative transesophageal echocardiographic assessment of pressure gradients. Transesophageal measurement of the three-dimensional left ventricular outflow tract cross-sectional area. MEASUREMENTS AND MAIN RESULTS: The smallest left ventricular outflow tract area increased on average 1.883 cm2 (98.3%) after septal myectomy. There was a significant correlation between the increase in the area and the transesophageal pressure gradients (r = -0.32; p = 0.01) after myectomy, but none with postoperative transthoracic gradients at rest (r = -0.10; p = 0.42). Postoperative transesophageal and transthoracic gradients were significantly correlated (r = 0.26; p = 0.04). The best risk factors to predict high residual gradients were preoperative transesophageal gradient >97 mmHg, postoperative transesophageal area <3.16 cm2, and moderate or more residual transesophageal mitral regurgitation (specificity 89%, 81%, and 78%, respectively). CONCLUSIONS: Three-dimensional left ventricular outflow tract area measurements with transesophageal echocardiography after myectomy correlated fairly well with postoperative transesophageal pressure gradients. Patients with residual transthoracic elevated gradients after surgery at follow-up had a smaller transesophageal area and higher transesophageal pressure gradients immediately after the procedure. However, transesophageal pressure gradients after myectomy correlated poorly with follow-up transthoracic gradients at rest.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Obstrução do Fluxo Ventricular Externo , Canadá , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Ecocardiografia Transesofagiana , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/cirurgia
2.
J Chromatogr B Biomed Sci Appl ; 754(1): 77-83, 2001 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-11318429

RESUMO

The CB.Hep-1 monoclonal antibody was coupled to CNBr-activated Sepharose CL 4B at three different immobilization scales for purification of recombinant hepatitis B surface antigen. Standard laboratory apparatus to obtain immunosorbents of 1 l (scale I) and 3 l (scale II) as well as a stirrer tank to prepare 6 l immunosorbents (scale III) were used. The binding capacity at scale III was 2- and 1.5-fold higher with respect to the scales II and I, while a reduction in the ligand leakage of 5- and 2-folds was observed. Immunosorbents from scale II showed a significantly reduced adsorption, and an increased ligand leakage. Differences in the coupling efficiency were not observed. Antigen purity eluted from the immunosorbents was always above 85%.


Assuntos
Anticorpos Monoclonais , Antígenos de Superfície da Hepatite B/isolamento & purificação , Técnicas de Imunoadsorção/instrumentação , Antígenos de Superfície da Hepatite B/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA