Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Front Oncol ; 12: 929727, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35936742

RESUMO

Purpose: Respiratory motion of locally advanced non-small cell lung cancer (LA-NSCLC) adds to the challenge of targeting the disease with radiotherapy (RT). One technique used frequently to alleviate this challenge is an internal gross tumor volume (IGTV) generated from manual contours on a single respiratory phase of the 4DCT via the aid of deformable image registration (DIR)-based auto-propagation. Through assessing the accuracy of DIR-based auto-propagation for generating IGTVs, this study aimed to identify erring characteristics associated with the process to enhance RT targeting in LA-NSCLC. Methods: 4DCTs of 19 patients with LA-NSCLC were acquired using retrospective gating with 10 respiratory phases (RPs). Ground-truth IGTVs (GT-IGTVs) were obtained through manual segmentation and union of gross tumor volumes (GTVs) in all 10 phases. IGTV auto-propagation was carried out using two distinct DIR algorithms for the manually contoured GTV from each of the 10 phases, resulting in 10 separate IGTVs for each patient per each algorithm. Differences between the auto-propagated IGTVs (AP-IGTVs) and their corresponding GT-IGTVs were assessed using Dice coefficient (DICE), maximum symmetric surface distance (MSSD), average symmetric surface distance (ASSD), and percent volume difference (PVD) and further examined in relation to anatomical tumor location, RP, and deformation index (DI) that measures the degree of deformation during auto-propagation. Furthermore, dosimetric implications due to the analyzed differences between the AP-IGTVs and GT-IGTVs were assessed. Results: Findings were largely consistent between the two algorithms: DICE, MSSD, ASSD, and PVD showed no significant differences between the 10 RPs used for propagation (Kruskal-Wallis test, ps > 0.90); MSSD and ASSD differed significantly by tumor location in the central-peripheral and superior-inferior dimensions (ps < 0.0001) while only in the central-peripheral dimension for PVD (p < 0.001); DICE, MSSD, and ASSD significantly correlated with the DI (Spearman's rank correlation test, ps < 0.0001). Dosimetric assessment demonstrated that 79% of the radiotherapy plans created by targeting planning target volumes (PTVs) derived from the AP-IGTVs failed prescription constraints for their corresponding ground-truth PTVs. Conclusion: In LA-NSCLC, errors in DIR-based IGTV propagation present to varying degrees and manifest dependences on DI and anatomical tumor location, indicating the need for personalized consideration in designing RT internal target volume.

2.
Med Dosim ; 44(3): 274-278, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30396725

RESUMO

Regional nodal irradiation (RNI) is an essential part of the treatment of high risk early stage (Stage IIb) and locally advanced (Stage III) breast cancer. Acceptable radiation plans can usually be achieved using 3-dimensional conformal radiation therapy with deep-inspiration breath hold to limit dose to the heart, although in some cases intensity-modulated radiation therapy produces superior results. The goal of this study is to identify radiographic parameters that predict the need for IMRT when delivering RNI. We retrospectively examined breast cancer patients treated with comprehensive RNI including internal mammary lymph nodes, supraclavicular lymph nodes, and undissected axillary lymph nodes at our institution from January 2016 to February 2018. Radiographic parameters including lung volume, internal mammary lymph nodes depth, modified central lung distance (mCLD), tangent length, and target height were recorded. Univariate and multivariate logistic regression was performed using IMRT as a binary endpoint (yes/no). A total of 46 patients were evaluated, of which 9 (20%) required IMRT. Five of the 9 (56%) IMRT patients were postmastectomy with a tissue expander in place. There was an increased likelihood of IMRT per 0.5 cm increase in mCLD (odds ratios [OR]: 3.27; 95% confidence interval [CI]: 1.39 to 9.63; p = 0.01) and per 1 cm increase in target height (OR: 1.77; 95% CI: 1.08 to 3.40; p = 0.04). A threshold value of 3.38 cm was identified for mCLD (OR 10.3; 95% CI: 2.14 to 61.4; p value = 0.005), and 25.2 cm for target height (OR 10.9; 95% CI: 2.19 to 82.7; p value = 0.007). When delivering RNI, larger values of mCLD and target height corresponded to the use of IMRT. Further investigations are warranted to confirm these findings, which may improve the efficiency of the treatment planning process and in turn patient care.


Assuntos
Neoplasias da Mama/radioterapia , Linfonodos/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Feminino , Humanos , Modelos Logísticos , Estudos Retrospectivos
3.
Med Dosim ; 44(4): 405-408, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30928177

RESUMO

For early-stage glottic cancers, intensity-modulated radiation therapy (IMRT) has been shown to have comparable local control to 3D-conformal radiotherapy with the advantage of decreased dose to the carotid arteries. The planning target volume (PTV) for early glottic cancers typically includes the entire larynx, plus a 3 to 5 mm uniform margin. The air cavity within the larynx creates a challenge for the inverse optimization process as the software attempts to "build up" dose within the air. This unnecessary attempt at dose build-up in air can lead to hot spots within the rest of the PTV and surrounding soft tissue. We hypothesized that removal of the air from the PTV would decrease hot spots and allow for a more homogeneous plan while still maintaining adequate coverage of the PTV. We analyzed 20 consecutive patients with early-stage glottic cancer, T1-2N0, who received IMRT at our institution from April 2015 to December 2016. Each patient received 63 to 65.25 Gy in 2.25 Gy per fraction. Two plans were created for each case: one in which the PTV included the laryngeal air cavity and one in which the air cavity was subtracted from the PTV to create a new PTV-air structure. Dosimetric variables were collected for PTV-air structure from both IMRT plans, including V100%, D98% D2%, and D0.2%. Dosimetric variables for spinal cord and the carotid arteries were also recorded. Homogeneity index (HI) defined as D98/D2 was calculated. Two-sided t-tests were used to compare dosimetric variables. The median PTV volume was 69.9 cc (standard deviation [SD] ± 28.7 cc) and the median air cavity volume removed was 11.0 cc (SD ± 3.4 cc). A 2-sided t-test revealed a statistically significant decrease in max dose (112.7% vs 108.8%, p value = 0.0002) and improvement of HI (0.93 vs 0.91, p value = 0.0023) for the PTV air in the IMRT plan optimized for PTV air, which had air excluded, compared to the IMRT plan optimized for PTV with air included. There was no significant worsening of PTV-air coverage or significant increase in doses to the organs at risk (OARs). The removal of the air cavity from the PTV for early-stage glottic cancers does not compromise PTV coverage or sparing of OARs and can result in a more homogeneous IMRT plan. A more homogeneous plan has the potential to reduce treatment morbidity, although further study is warranted to investigate the clinical impact of air cavity removal from the PTV.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Glote , Neoplasias Laríngeas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada , Humanos , Órgãos em Risco/efeitos da radiação , Radiometria , Carga Tumoral
4.
Med Dosim ; 40(1): 89-95, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25534166

RESUMO

To identify anatomic and treatment characteristics that correlate with organ-at-risk (OAR) sparing with deep inspiration breath-hold (DIBH) technique to guide patient selection for this technique. Anatomic and treatment characteristics and radiation doses to OARs were compared between free-breathing and DIBH plans. Linear regression analysis was used to identify factors independently predicting for cardiac sparing. We identified 64 patients: 44 with intact breast and 20 postmastectomy. For changes measured directly on treatment planning scans, DIBH plans decreased heart-chest wall length (6.5 vs 5.0cm, p < 0.001), and increased lung volume (1074.4 vs 1881.3cm(3), p < 0.001), and for changes measured after fields are set, they decreased maximum heart depth (1.1 vs 0.3cm, p < 0.001) and heart volume in field (HVIF) (9.1 vs 0.9cm(3), p < 0.001). DIBH reduced the mean heart dose (3.4 vs 1.8Gy, p < 0.001) and lung V20 (19.6% vs 15.3%, p < 0.001). Regression analysis found that only change in HVIF independently predicted for cardiac sparing. We identified patients in the bottom quartile of the dosimetric benefits seen with DIBH and categorized the cause of this "minimal benefit." Overall, 29% of patients satisfied these criteria for minimal benefit with DIBH and the most common cause was favorable baseline anatomy. Only the reduction in HVIF predicted for reductions in mean heart dose; no specific anatomic surrogate for the dosimetric benefits of DIBH technique could be identified. Most patients have significant dosimetric benefit with DIBH, and this technique should be planned and evaluated for all patients receiving left-sided breast/chest wall radiation.


Assuntos
Neoplasias da Mama/radioterapia , Suspensão da Respiração , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Feminino , Humanos , Inalação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA