Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Bases de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(12)2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37420685

RESUMO

We present the development of an electrochemical paper-based analytical device (ePAD) for the detection of methamphetamine. Methamphetamine is a stimulant that young people use as an addictive narcotic, and it must be detected quickly since it may be hazardous. The suggested ePAD has the advantages of being simple, affordable, and recyclable. This ePAD was developed by immobilizing a methamphetamine-binding aptamer onto Ag-ZnO nanocomposite electrodes. The Ag-ZnO nanocomposites were synthesized via a chemical method and were further characterized via scanning electron microscopy, Fourier transform infrared spectroscopy, and UV-vis spectrometry in terms of their size, shape, and colloidal activity. The developed sensor showed a limit of detection of about 0.1 µg/mL, with an optimum response time of about 25 s, and its extensive linear range was between 0.01 and 6 µg/mL. The application of the sensor was recognized by spiking different beverages with methamphetamine. The developed sensor has a shelf life of about 30 days. This cost-effective and portable platform might prove to be highly successful in forensic diagnostic applications and will benefit those who cannot afford expensive medical tests.


Assuntos
Metanfetamina , Nanocompostos , Óxido de Zinco , Humanos , Adolescente , Óxido de Zinco/química , Prata/química , Nanocompostos/química , Eletrodos , Técnicas Eletroquímicas/métodos
2.
Micromachines (Basel) ; 15(3)2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38542559

RESUMO

Ketamine is one of the most commonly abused drugs globally, posing a severe risk to social stability and human health, not only it is being used for recreational purposes, but this tasteless, odourless, and colourless drug also facilitates sexual assaults when it is mixed with drinks. Ketamine abuse is a threat for safety, and this misuse is one of the main uses of the drug. The crucial role of ketamine detection is evident in its contributions to forensic investigations, law enforcement, drug control, workplace integrity, and public health. Electrochemical sensors have gained considerable interest among researchers due to their various advantages, such as low cost and specificity, and particularly screen-printed paper-based electrode (SPBE) biosensors have gained attention. Here, we reported an ePAD (electrochemical paper-based analytical device) for detecting the recreational drug ketamine. The advantages of using a paper-based electrode are that it reduces the electrode's production costs and is disposable and environmentally friendly. At the same time, nanographite sheets (NGSs) assisted in amplifying the signals generated in the cyclic voltammetry system when ketamine was present. This ePAD was developed by immobilizing a ketamine aptamer on NGS electrodes. The characterization of proper synthesized NGSs was performed by Scanning Electron Microscopy (SEM), XRD (X-ray Diffraction), Fourier-transform infrared spectroscopy (FTIR), and UV-Vis spectroscopy. Electrochemical techniques, including cyclic voltammetry (CV) and linear sweep voltammetry (LSV), were employed to validate the results and confirm each attachment. Furthermore, the versatility of the proposed sensor was explored in both alcoholic and non-alcoholic beverages. The developed sensor showed a low LOD of about 0.01 µg/mL, and the linear range was between 0.01 and 5 µg/mL. This approach offers a valid diagnostic technique for onsite service with minimal resources. This cost effective and portable platform offers desirable characteristics like sensitivity and selectivity and can also be used for POC (point of care) testing to help in the quick identification of suspicious samples and for testing at trafficking sites, amusement parks, and by the side of the road.

3.
Biosensors (Basel) ; 13(10)2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37887127

RESUMO

Illicit drug misuse has become a widespread issue that requires continuous drug monitoring and diagnosis. Wearable electrochemical drug detection devices possess the potential to function as potent screening instruments in the possession of law enforcement personnel, aiding in the fight against drug trafficking and facilitating forensic investigations conducted on site. These wearable sensors are promising alternatives to traditional detection methods. In this study, we present a novel wearable electrochemical glove-based analytical device (eGAD) designed especially for detecting the club drug, methamphetamine. To develop this sensor, we immobilized meth aptamer onto silver nanoparticle (AgNPs)-modified electrodes that were printed onto latex gloves. The characteristics of AgNPs, including their shape, size and purity were analysed using FTIR, SEM and UV vis spectrometry, confirming the successful synthesis. The developed sensor shows a 0.1 µg/mL limit of detection and 0.3 µg/mL limit of quantification with a linear concentration range of about 0.01-5 µg/mL and recovery percentages of approximately 102 and 103%, respectively. To demonstrate its applicability, we tested the developed wearable sensor by spiking various alcoholic and non-alcoholic drink samples. We found that the sensor remains effective for 60 days, making it a practical option with a reasonable shelf-life. The developed sensor offers several advantages, including its affordability, ease of handling and high sensitivity and selectivity. Its portable nature makes it an ideal tool for rapid detection of METH in beverages too.


Assuntos
Nanopartículas Metálicas , Metanfetamina , Dispositivos Eletrônicos Vestíveis , Nanopartículas Metálicas/química , Prata/química , Eletrodos , Técnicas Eletroquímicas/métodos
4.
Int J Biol Macromol ; 217: 435-448, 2022 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-35817236

RESUMO

The virus known as Japanese Encephalitis (JEV) is among the common viral persisting Encephalitis caused by Flavivirus around the Globe, especially in Southeast Asian nations. JEV may be a leading reason for neurological illness in humans, with an estimated 70,000 human cases and 10,000 fatalities per annum. The conventional methods like PRNT (Plaque Reduction Neutralization Test), ELISA (Enzyme-linked immunosorbent assay) RT-PCR (reverse transcription-polymerase chain reaction), and virus isolation are few commercial tests being availed these days, but they have a variety of drawbacks, including being extremely expensive, time-consuming, and requiring expertise. Therefore, researches are being made in the development of improved inexpensive, shorter, sensitive, and time-saving strategies to diagnose the Japanese Encephalitis Virus. A number of these researches encompass the employment of immunosensors, electrochemical sensors and along with the applications of nanotechnology to create highly sensitive detecting device. This review article is based on contemporary breakthroughs in diagnosing Japanese Encephalitis Virus, which are crucial in severing the connection between the propagation of zoonotic disease into the current race, where humans function as dead-end hosts.


Assuntos
Técnicas Biossensoriais , Vírus da Encefalite Japonesa (Espécie) , Encefalite Japonesa , Encefalite Japonesa/diagnóstico , Humanos , Imunoensaio , Sensibilidade e Especificidade
5.
Micromachines (Basel) ; 13(11)2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36363867

RESUMO

A notable diagnostic for the detection of hemolytic diseases is bilirubin, a by-product of haemoglobin breakdown. The concentration of bilirubin ranges from 0.3 to 1.9 mg in 100 mL of blood. Low blood bilirubin levels are associated with a greater risk of coronary heart disease and anaemia. Hyperbilirubinemia results from a serum bilirubin level of more than 2.5 mg/100 mL. Therefore, it is very crucial to check the serum bilirubin level. Analytical equipment for point-of-care testing must be portable, small, and affordable. A unique method is used to detect bilirubin selectively using paper-based screen-printed carbon electrodes that were covalently linked with nanoparticles, that serves as a key biomarker for jaundice. In order to create an electrochemical biosensor, bilirubin oxidase was immobilised on electrodes modified with AgNPs. The morphology of Ag nanoparticles in terms of size and shape was determined using both UV- Vis Spectroscopy and transmission electron microscopy (TEM). The biosensor's analytical response was assessed using potentiostat (Cyclic voltammetry (CV) and linear sweep voltammetry (LSV)). The developed paper-based sensor provided optimum feedback and a broad linear range of 1 to 9 µg/mL for bilirubin, with a lower LOD of 1 µg/mL. Through tests of bilirubin in artificial blood serum, the viability is confirmed. The method that is being used makes it possible to create and use an inexpensive, miniature electrochemical sensor.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA