Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Orthop Sci ; 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37121790

RESUMO

BACKGROUND: The efficacy and safety of enhanced recovery after surgery (ERAS) protocols for patients undergoing total knee arthroplasty (TKA) have been generally proven. Previous studies investigating patients undergoing simultaneous bilateral TKA (SBTKA) focused on complications, mortality, and pain and did not examine patients' functional limitations. Therefore, the aim of this study was to investigate to what extent patients undergoing SBTKA are able to meet functional discharge criteria originally designed for their counterparts undergoing unilateral TKA (UTKA) in an ERAS setting. MATERIALS AND METHODS: All patients who received primary SBTKA between June 2015 and December 2018 were included in this retrospective analysis. For comparison, UTKA patients were matched 1:1 to SBTKA patients using Propensity Score Matching based on age, gender, and BMI. The times to achieving the rehabilitation checkpoints of walking 150 m, walking a flight of stairs, and 90° knee flexion were evaluated. RESULTS: 63 (SBTKA group) and 64 (UTKA group) patients were included. Due to the Propensity-Score-Matching there were no differences regarding age, gender, and BMI. The mean length of stay (LOS) was 9.1 days in the SBTKA and 7.6 days in the UTKA group (p = 0.003). On average, it took SBTKA patients 5.4 days to achieve an uninterrupted walking distance of at least 150 m, while it took UTKA patients 4.1 days (p < 0.001). Mean time to walking a flight of stairs was 6.3 days for SBTKA patients and 4.7 days for UTKA patients (p < 0.001). 90° flexion was achieved after 4.1 days by SBTKA patients and 3.5 days by UTKA patients (p = 0.241). CONCLUSION: The vast majority of SBTKA patients were able to achieve functional discharge criteria within their inpatient stay when allowed about 30% extra time. Therefore, functional discharge criteria in ERAS protocols designed for UTKA can be considered appropriate for SBTKA patients. LEVEL OF EVIDENCE: Therapeutic Level III.

2.
Int Orthop ; 38(6): 1255-60, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24402556

RESUMO

PURPOSE: Surgical treatment of distal tibial fractures demands a stable fracture fixation while minimizing the irritation to the soft tissues by approach and implant. Biomechanical studies have demonstrated superior performance for angular-stable locked nails over standard locked nails in distal tibial fractures. The experimental Retrograde Tibial Nail (RTN) is a minimally invasive local intramedullary osteosynthesis, which has been under design by our group. We conducted a biomechanical comparison in composite tibiae of the Retrograde Tibial Nail against the Expert Tibial Nail (Synthes®). Our hypothesis was that the RTN would provide equivalent biomechanical stability with respect to extra-axial compression, torsion and load to failure testing, in an extra-articular distal tibia fracture model. METHODS: Biomechanical composite bone testing was conducted in 14 biomechanical composite tibiae in an AO 43 A3 fracture model. In both groups, triple angle stable interlocking was performed in the distal fragment. RESULTS: Results show a statistically non-significant higher stability of the ETN during the axial loading tests. Torsional stability testing resulted in a statistically superior performance for the RTN (p = 0.018). Destructive extra-axial compression resulted in failure of six ETN constructs, while all RTN specimens survived the maximal load. CONCLUSIONS: The experimental Retrograde Tibial Nail provides the key features for the treatment of distal tibial fractures. It combines a minimally invasive local intramedullary osteosynthesis with the ability to securely fix the fracture by multiple angle stable locking options.


Assuntos
Fraturas do Tornozelo/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Fraturas da Tíbia/cirurgia , Fraturas do Tornozelo/fisiopatologia , Fenômenos Biomecânicos , Pinos Ortopédicos , Fixação Intramedular de Fraturas/métodos , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos , Modelos Anatômicos , Desenho de Prótese , Fraturas da Tíbia/fisiopatologia
3.
Eur J Trauma Emerg Surg ; 48(5): 3693-3700, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34859267

RESUMO

OBJECTIVES: Retrograde tibial nailing using the Distal Tibia Nail (DTN) is a novel surgical option in the treatment of distal tibial fracture. Its unique retrograde insertion increases the range of surgical options in far distal fractures of the tibia beyond the use of plating. The aim of this study was to assess the feasibility of the DTN for far distal tibia fractures where only double rather than triple-distal locking is possible due to fracture localisation and morphology. METHODS: Six Sawbones® were instrumented with a DTN and an AO/OTA 43-A3 fracture simulated. Samples were tested in two configurations: first with distal triple locking, second with double locking by removing one distal screw. Samples were subjected to compressive (350 N, 600 N) and torsional (± 8 Nm) loads. Stiffness construct and interfragmentary movement were quantified and compared between double and triple-locking configurations. RESULTS: The removal of one distal screw resulted in a 60-70% preservation of compressive stiffness, and 90% preservation of torsional stiffness for double locking compared to triple locking. Interfragmentary movement remained minimal for both compressive and torsional loading. CONCLUSIONS: The DTN with a distal double locking can, therefore, be considered for far distal tibia fractures where nailing would be preferred over plating.


Assuntos
Fraturas do Tornozelo , Fixação Intramedular de Fraturas , Fraturas da Tíbia , Fenômenos Biomecânicos , Pinos Ortopédicos , Placas Ósseas , Fixação Intramedular de Fraturas/métodos , Humanos , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia
4.
Sci Rep ; 11(1): 18834, 2021 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-34552116

RESUMO

The Distal Tibia Nail (DTN; Mizuho, Japan) has demonstrated higher biomechanical stiffness to locking plates in previous research for A3 distal tibia fractures. It is here investigated as a fixation option for supramalleolar corrective osteotomies (SMOT). Sixteen Sawbones tibiae were implanted with either a DTN (n = 8) or Medial Distal Tibia Plate (MDTP; n = 8) and a SMOT simulated. Two surgical outcome scenarios were envisaged: "best-case" representing an intact lateral cortex, and "worst-case" representing a fractured lateral cortex. All samples were subjected to compressive (350 N, 700 N) and torsional (± 4 Nm, ± 8 Nm) testing. Samples were evaluated using calculated construct stiffness from force-displacement data, interfragmentary movement and Von Mises' strain distribution. The DTN demonstrated a greater compressive stiffness for the best-case surgical scenario, whereas the MDTP showed higher stiffness (p < 0.05) for the worst-case surgical scenario. In torsional testing, the DTN proved more resistant to torsion in the worst-case surgical setup (p < 0.05) for both ± 4 Nm and ± 8 Nm. The equivalent stiffness of the DTN against the MDTP supports the use of this implant for SMOT fixation and should be considered as a treatment option particularly in patients presenting vascularisation problems where the MDTP is an inappropriate choice.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Fixação Interna de Fraturas/métodos , Osteotomia/métodos , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Pinos Ortopédicos/efeitos adversos , Placas Ósseas/efeitos adversos , Força Compressiva , Fixação Interna de Fraturas/instrumentação , Humanos , Osteotomia/instrumentação , Torção Mecânica
5.
Injury ; 46 Suppl 4: S99-S103, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26542874

RESUMO

In factures of the distal tibia with simple articular extension, the optimal surgical treatment remains debatable. In clinical practice, minimally invasive plate osteosynthesis and intramedullary nailing are both routinely performed. Comparative biomechanical studies of different types of osteosynthesis of intraarticular distal tibial fractures are missing due to the lack of an established model. The goal of this study was first to establish a biomechanical model and second to investigate, which are the biomechanical advantages of angle-stable plate osteosynthesis and intramedullary nailing of distal intraarticular tibial fractures. Seven 4(th) generation biomechanical composite tibiae featuring an AO 43-C2 type fracture were implanted with either osteosynthesis technique. After primary lag screw fixation, 4-hole Medial Distal Tibial Plate (MDTP) with triple proximal and quadruple distal screws or intramedullary nailing with double proximal and triple 4.0mm distal interlocking were implanted. The stiffness of the implant-bone constructs and interfragmentary movement were measured under non-destructive axial compression (350 and 600 N) and torsion (1.5 and 3Nm). Destructive axial compression testing was conducted with a maximal load of up to 1,200 N. No overall superior biomechanical results can be proclaimed for either implant type. Intramedullary nailing displays statistically superior results for axial loading in comparison to the MDTP. Torsional loading resulted in non-statistically significant differences for the two-implant types with higher stability in the MDTP group. From a biomechanical view, the load sharing intramedullary nail might be more forgiving and allow for earlier weight bearing in patients with limited compliance.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Fixação Intramedular de Fraturas/instrumentação , Fraturas Intra-Articulares/cirurgia , Osteotomia , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Estudos de Viabilidade , Fixação Intramedular de Fraturas/métodos , Humanos , Osteotomia/métodos , Torção Mecânica , Suporte de Carga
6.
Injury ; 45 Suppl 1: S81-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24225228

RESUMO

Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group. The implant offers double proximal and triple distal interlocking with an end cap leading to an angle-stable screw-nail construct of the most distal interlocking screw. Its design meets the requirements of a minimally invasive surgical approach, with a stable fracture fixation by multiple locking options. The 8mm diameter curved nail, with a length of 120 mm, is introduced through an entry portal at the medial malleolus. We see possible indications for the RTN in far distal tibial shaft fractures, distal extraarticular metaphyseal tibial fractures and in distal tibia fractures with simple extension into the ankle joint when the nail is combined lag screw fixation. A biomechanical comparison of the current RTN prototype against antegrade nailing (Expert Tibial Nail, Synthes(®), ETN) was performed. Both implants were fixed with double proximal and triple distal interlocking. Seven biomechanical composite tibiae were treated with either osteosynthesis techniques. A 10mm defect osteotomy 40 mm proximal to the joint line served as an AO 43-A3 type distal tibial fracture model. The stiffness of the implant-bone constructs was measured under low and high extra-axial compression (350 and 600 N) and under torsional load (8 Nm). Results show a comparable stability during axial loading for the two implant types with slightly higher stability in the RTN group. Rotational stability was superior for the RTN. Statistical analysis proved a significant difference (p<0.05) between the ETN and RTN for rotational stability. This study suggests that retrograde tibia nailing with the RTN is a promising new concept for the treatment of distal tibia fractures.


Assuntos
Pinos Ortopédicos , Placas Ósseas , Fixação Intramedular de Fraturas , Fraturas da Tíbia/cirurgia , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/patologia , Resultado do Tratamento
7.
J Orthop Surg Res ; 9: 35, 2014 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-24886667

RESUMO

BACKGROUND: Currently, antegrade intramedullary nailing and minimally invasive plate osteosynthesis (MIPO) represent the main surgical alternatives in distal tibial fractures. However, neither choice is optimal for all bony and soft tissue injuries. The Retrograde Tibial Nail (RTN) is a small-caliber prototype implant, which is introduced through a 2-cm-long incision at the tip of the medial malleolus with stab incisions sufficient for interlocking. During this project, we investigated the feasibility of retrograde tibial nailing in a cadaver model and conducted biomechanical testing. METHODS: Anatomical implantations of the RTN were carried out in AO/OTA 43 A1-3 fracture types in three cadaveric lower limbs. Biomechanical testing was conducted in an AO/OTA 43 A3 fracture model for extra-axial compression, torsion, and destructive extra-axial compression. Sixteen composite tibiae were used to compare the RTN against an angle-stable plate osteosynthesis (Medial Distal Tibial Plate, Synthes®). Statistical analysis was performed by Student's t test. RESULTS: Retrograde intramedullary nailing is feasible in simple fracture types by closed manual reduction and percutaneous reduction forceps, while in highly comminuted fractures, the use of a large distractor can aid the reduction. Biomechanical testing shows a statistically superior stability (p < 0.001) of the RTN during non-destructive axial loading and torsion. Destructive extra-axial compression testing resulted in failure of all plate constructs, while all RTN specimens survived the maximal load of 1,200 N. CONCLUSIONS: The prototype retrograde tibial nail meets the requirements of maximum soft tissue protection by a minimally invasive surgical approach with the ability of secure fracture fixation by multiple locking options. Retrograde tibial nailing with the RTN is a promising concept in the treatment of distal tibia fractures.


Assuntos
Placas Ósseas , Fixação Intramedular de Fraturas/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fraturas da Tíbia/cirurgia , Adulto , Fenômenos Biomecânicos/fisiologia , Placas Ósseas/normas , Cadáver , Estudos de Viabilidade , Fixação Intramedular de Fraturas/normas , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/normas , Radiografia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem
8.
Injury ; 41(10): 1015-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20347084

RESUMO

INTRODUCTION: Secondary loss of reduction and pseudarthrosis due to unstable fixation methods remain challenging problems of surgical stabilisation of radial head fractures. The purpose of our study was to determine whether the 3.0mm Headless Compression Screw (HCS) provides superior stability to the standard 2.0 mm cortical screw (COS). MATERIALS AND METHODS: Eight pairs of fresh frozen human cadaveric proximal radii were used for this paired comparison. A standardised Mason II-Fracture was created with a fragment size of 1/3 of the radial head's articular surface that was then stabilised either with two 3.0 mm HCS (Synthes) or two 2.0 mm COS (Synthes) according to a randomisation protocol. The specimens were then loaded axially and transversely with 100 N each for 4 cycles. Cyclic loading with 1000 cycles as well as failure load tests were performed. The Wilcoxon test was used to assess statistically significant differences between the two groups. RESULTS: No statistical differences could be detected between the two fixation methods. Under axial loads the COS showed a displacement of 0.32 mm vs. 0.49 mm for the HCS. Under transverse loads the displacement was 0.25 mm for the COS vs. 0.58 mm for the HCS group. After 1000 cycles of axial loading there were still no significant differences. The failure load for the COS group was 291 N and 282 N for the HCS group. CONCLUSION: No significant differences concerning the stability achieved by 3.0 mm HCS and the 2.0 mm COS could be detected in the experimental setup presented.


Assuntos
Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas do Rádio/cirurgia , Fenômenos Biomecânicos , Cadáver , Fixação Interna de Fraturas/métodos , Humanos , Distribuição Aleatória , Suporte de Carga/fisiologia
9.
J Hand Surg Am ; 32(10): 1569-75, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18070646

RESUMO

PURPOSE: Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs. METHODS: Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0-mm radial head plate. Implants were tested under axial (N/mm) and torsional (Ncm/ degrees ) loads with a servohydraulic materials testing machine. RESULTS: The radial head plate was significantly stiffer than all other implants under axial as well as under torsional loads, with values of 36 N/mm and 13 Ncm/ degrees . The second-stiffest implant was the blade plate, with values of 20 N/mm and 6 Ncm/ degrees . The weakest implants were the 2.0-mm LCP, with values of 6 N/mm and 2 Ncm/ degrees , and the 2.0-mm crossed screws, with values of 18 N/mm and 2 Ncm/ degrees . The 2.4-mm T plate, with values of 14 N/mm and 4 Ncm/ degrees , and the 2.0-mm grid plate, with values of 8 N/mm and 4 Ncm/ degrees came to lie in the midfield. CONCLUSIONS: The 2.0-mm angle-stable plates-depending on their design-allow fixation with comparable or even higher stability than the bulky 2.4-mm nonlocking implants and 2.0-mm crossed screws.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Teste de Materiais , Fraturas do Rádio/cirurgia , Cadáver , Humanos , Desenho de Prótese , Radiografia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Estresse Mecânico , Torção Mecânica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA