Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Heart Vessels ; 30(3): 386-95, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-24820450

RESUMO

The hemodynamic load due to physical activity leads to structural and functional cardiac adaptations known as "Athlete's heart". We aimed to compare myocardial performance in different groups of trained athletes by means of 3D echocardiography and 3D speckle tracking echocardiography (3D-STE). 66 athletes [26 strength-trained athletes (STA) and 40 endurance athletes (ETA)] were prospectively enrolled. A control group of 40 sedentary subjects (sedentary group) was also included. All subjects underwent both standard and 3D evaluation of left ventricular (LV) function including 3D-STE. Left ventricular mass indexed for body surface area, LV end-diastolic (LV Dd) thickness of interventricular septum and posterior wall thickness mean values were significantly increased in athletes (p < 0.001, p < 0.01 and p < 0.001, respectively). LV diastolic diameter index had a significantly higher mean value in ETA in respect to sedentary group (p = 0.001). Despite a preserved mean value of LV ejection fraction (LV EF) in all the groups, subjects in STA group showed a significant reduction of strain in the longitudinal, radial and circumferential directions (p < 0.05 for all). Area strain mean value was also reduced in STA group (p < 0.01). In the overall population, an inverse relationship between longitudinal strain and LV Dd index (r = -0.260, p = 0.008), the E/A ratio (r = -0.249, p = 0.010) and the E' velocity (r = -0.259, p = 0.009) has been identified. Sport-specific patterns of ventricular morphological and functional remodeling are present in athletes performing different kinds of training. 3D-STE is a useful and feasible echocardiographic technique for the assessment of sport-specific pattern of deformational adaptations.


Assuntos
Atletas , Cardiomegalia Induzida por Exercícios , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Contração Miocárdica , Resistência Física , Função Ventricular Esquerda , Remodelação Ventricular , Adaptação Fisiológica , Adulto , Ciclismo , Fenômenos Biomecânicos , Estudos de Casos e Controles , Estudos Transversais , Ecocardiografia Doppler de Pulso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Natação , Fatores de Tempo , Adulto Jovem
2.
J Cardiovasc Med (Hagerstown) ; 17(11): 843-9, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26258717

RESUMO

AIMS: To appraise the early effect of percutaneous mitral valve repair with the MitraClip system on myocardial function using real-time three-dimensional speckle-tracking echocardiography (3D-STE). METHODS: Consecutive patients with moderate-to-severe or severe mitral regurgitation, undergoing mitral valve repair with the MitraClip system, were prospectively evaluated during the peri-procedural workout and follow-up. Left ventricular deformation was evaluated by a two-dimensional and 3D speckle-tracking analysis. 3D-STE acquisitions were elaborated obtaining real-time 3D global longitudinal strain evaluation, and by appraising both volumetric and hemodynamic parameters (i.e. left ventricular end-diastolic volume, left ventricular end-systolic volume, left ventricular ejection fraction, cardiac output, and stroke volume). RESULTS: In all, 30 patients were included. At 1-month follow-up, 3D-STE analysis revealed no changes in left ventricular end-diastolic volume (162.6 ±â€Š73.7 ml at baseline vs. 159.8 ±â€Š64.5 ml at 1-month follow-up; P = 0.63) and a downward trend in left ventricular end-systolic volume (104.7 ±â€Š52.0 vs. 100.1 ±â€Š50.4 ml, respectively; P = 0.06). Left ventricular ejection fraction did not significantly increase (38.1 ±â€Š11.3% at baseline vs. 39.4 ±â€Š11.0% at 1-month follow-up; P = 0.20). No significant changes were reported in cardiac output (4.3 ±â€Š2.0 l/min at baseline vs. 4.0 ±â€Š1.5 l/min at follow-up; P = 0.377) and in stroke volume (59.5 ±â€Š25.5 ml at baseline vs. 59.9 ±â€Š20.7 ml at follow-up; P = 0.867). On the contrary, left ventricular deformation capability significantly improved, with the real-time 3D global longitudinal strain value changing from -9.8 ±â€Š4.1% at baseline to -11.0 ±â€Š4.4% at follow-up (P = 0.018). CONCLUSIONS: Accurately assessing myocardial function by the use of 3D-STE, this study reported irrelevant early changes in left ventricular size, but a positive effect on left ventricular deformation capability following mitral valve repair with the MitraClip system. These preliminary results need to be confirmed in larger series and extended to long-term follow-up.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Volume Sistólico , Dispositivos de Fixação Cirúrgica/estatística & dados numéricos , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Tridimensional , Feminino , Humanos , Masculino , Resultado do Tratamento
3.
Int J Cardiovasc Imaging ; 30(6): 1037-47, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24794426

RESUMO

Subclinical myocardial dysfunction has been identified in obese subjects without cardiovascular risks factors and has been defined as "obesity cardiomyopathy". We evaluated left ventricular (LV) function and geometry in obese patients by using a 3 dimensional echocardiography (3DE). We also aimed to look at the influence of ventricular geometry upon functional parameters of the LV by using 3D speckle tracking imaging (3D-STI). 30 consecutive and asymptomatic obese cases (OB group) with no comorbidities were prospectively enrolled. The control group included 30 healthy volunteers (HS group), matched for age and sex. All subjects underwent 3DE and 3D-STI. Ventricular geometry was evaluated with the LV sphericity index (LV SpI) and the LV diastolic volume to mass ratio (LV EDV/Mass ratio). LV Mass was significantly increased in OB group and the LV EDV/Mass ratio had a significantly lower mean value in this group (p < 0.001 and p = 0.002, respectively). LV SpI was significantly reduced in obese subjects (p < 0.001). A significant reduction in longitudinal (GLS), radial (GRS) and area strain (GAS) was observed in OB group (p = 0.001 for all) while circumferential mechanic (GCS) was not different between the two groups (p = 0.052). LV EDV to mass ratio was significantly related to GLS (r = -0.298, p = 0.022) and GAS (r = -0.289, p = 0.026). On multivariate analysis, GRS and GAS were independently related to LV SpI (ß = 0.222, p = 0.031 and ß = -0.222, p = 0.034, respectively). Geometrical and structural ventricular remodeling negatively influences functional properties of the LV in obese subjects without cardiovascular risks factors. Further studies are needed to assess the prognostic value of our findings.


Assuntos
Ecocardiografia Doppler de Pulso , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Obesidade/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Estudos de Casos e Controles , Diagnóstico Precoce , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Obesidade/diagnóstico por imagem , Obesidade/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
4.
J Cardiovasc Med (Hagerstown) ; 14(4): 317-8, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22801073

RESUMO

Periodic echocardiographic evaluation of valve function is recommended in all patients with prosthetic valves. Usually trans-thoracic echocardiography (TTE) is satisfactory to assess prosthetic function. Nevertheless when the TTE is suboptimal or in case of strong clinical doubt of prosthetic valve dysfunction, trans-esophageal echocardiography (TEE) remains the gold standard of imaging. Recent advancements in echocardiography, with the three-dimensional (3D) reconstruction, provide an incremental diagnostic value as compared to two-dimensional TEE. In addition, 3D-TEE gives unique views that add extra morphological and anatomical information, providing a very accurate presurgical evaluation.


Assuntos
Próteses Valvulares Cardíacas , Valva Mitral/diagnóstico por imagem , Falha de Prótese , Idoso , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Valva Mitral/cirurgia , Trombose/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA