Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 118(4)2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33468681

RESUMO

Glacial landforms, including lobate debris aprons, are a global water ice reservoir on Mars preserving ice from past periods when high orbital obliquity permitted nonpolar ice accumulation. Numerous studies have noted morphological similarities between lobate debris aprons and terrestrial debris-covered glaciers, an interpretation supported by radar observations. On Earth and Mars, these landforms consist of a core of flowing ice covered by a rocky lag. Terrestrial debris-covered glaciers advance in response to climate forcing driven by obliquity-paced changes to ice mass balance. However, on Mars, it is not known whether glacial landforms emplaced over the past 300 to 800 formed during a single, long deposition event or during multiple glaciations. Here, we show that boulders atop 45 lobate debris aprons exhibit no evidence of monotonic comminution but are clustered into bands that become more numerous with increasing latitude, debris apron length, and pole-facing flow orientation. Boulder bands are prominent at glacier headwalls, consistent with debris accumulation during the current Martian interglacial. Terrestrial glacier boulder bands occur near flow discontinuities caused by obliquity-driven hiatuses in ice accumulation, forming internal debris layers. By analogy, we suggest that Martian lobate debris aprons experienced multiple cycles of ice deposition, followed by ice destabilization in the accumulation zone, leading to boulder-dominated lenses and subsequent ice deposition and continued flow. Correlation between latitude and boulder clustering suggests that ice mass-balance works across global scales on Mars. Lobate debris aprons may preserve ice spanning multiple glacial/interglacial cycles, extending Mars climate records back hundreds of millions of years.

2.
J Antimicrob Chemother ; 78(11): 2653-2659, 2023 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-37681452

RESUMO

BACKGROUND: Feminizing hormone therapy (FHT) is essential to many trans women. Concern about negative drug interactions between FHT and ART can be an ART adherence barrier among trans women with HIV. OBJECTIVES: In this single-centre, parallel group, cross-sectional pilot study, we measured serum oestradiol concentrations in trans women with HIV taking FHT and unboosted integrase strand transfer inhibitor (INSTI)-based ART versus trans women without HIV taking FHT. METHODS: We included trans women with and without HIV, aged ≥18 years, taking ≥2 mg/day of oral oestradiol for at least 3 months plus an anti-androgen. Trans women with HIV were on suppressive ART ≥3 months. Serum oestradiol concentrations were measured prior to medication dosing and 2, 4, 6 and 8 h post-dose. Median oestradiol concentrations were compared between groups using Wilcoxon rank-sum tests. RESULTS: Participants (n = 8 with HIV, n = 7 without) had a median age of 32 (IQR: 28, 39) years. Among participants, the median oral oestradiol dose was 4 mg (range 2-6 mg). Participants had been taking FHT for a median of 4 years (IQR: 2, 8). Six trans women with HIV were taking bictegravir/emtricitabine/tenofovir alafenamide and two were taking dolutegravir/abacavir/lamivudine. All oestradiol concentrations were not significantly different between groups. Eleven (73%) participants had target oestradiol concentrations in the range 200-735 pmol/L at C4h (75% among women with HIV, 71% among those without HIV). CONCLUSIONS: Oestradiol concentrations were not statistically different in trans women with HIV compared with those without HIV, suggesting a low probability of clinically relevant drug-drug interactions between FHT and unboosted INSTI-based ART.


Assuntos
Infecções por HIV , Inibidores de Integrase de HIV , HIV-1 , Humanos , Feminino , Adolescente , Adulto , Infecções por HIV/tratamento farmacológico , Projetos Piloto , Emtricitabina/uso terapêutico , Estudos Transversais , Inibidores de Integrase de HIV/uso terapêutico
3.
Eur J Nucl Med Mol Imaging ; 50(4): 980-995, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36469107

RESUMO

PURPOSE: Quantitative SPECT-CT is a modality of growing importance with initial developments in post radionuclide therapy dosimetry, and more recent expansion into bone, cardiac and brain imaging together with the concept of theranostics more generally. The aim of this document is to provide guidelines for nuclear medicine departments setting up and developing their quantitative SPECT-CT service with guidance on protocols, harmonisation and clinical use cases. METHODS: These practice guidelines were written by members of the European Association of Nuclear Medicine Physics, Dosimetry, Oncology and Bone committees representing the current major stakeholders in Quantitative SPECT-CT. The guidelines have also been reviewed and approved by all EANM committees and have been endorsed by the European Association of Nuclear Medicine. CONCLUSION: The present practice guidelines will help practitioners, scientists and researchers perform high-quality quantitative SPECT-CT and will provide a framework for the continuing development of quantitative SPECT-CT as an established modality.


Assuntos
Medicina Nuclear , Humanos , Cintilografia , Medicina Nuclear/métodos , Diagnóstico por Imagem , Radioisótopos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único
4.
J Nucl Cardiol ; 29(1): 56-68, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32440990

RESUMO

BACKGROUND: In myocardial perfusion PET, images are acquired during vasodilator stress, increasing the likelihood of intra-frame motion blurring of the heart in reconstructed static images to assess relative perfusion. This work evaluated a prototype data-driven motion correction (DDMC) algorithm designed specifically for cardiac PET. METHODS: A cardiac torso phantom, with a solid defect, was scanned stationary and being manually pulled to-and-fro in the axial direction with a random motion. Non-motion-corrected (NMC) and DDMC images were reconstructed. Total perfusion deficit was measured in the defect and profiles through the cardiac insert were defined. In addition, 46 static perfusion images from 36 rubidium-82 MPI patients were selected based upon a perception of motion blurring in the images. NMC and DDMC images were reconstructed, blinded, and scored on image quality and perceived motion. RESULTS: Phantom data demonstrated near-perfect recovery of myocardial wall visualization and defect quantification with DDMC compared with the stationary phantom. Quality of clinical images was NMC: 10 non-diagnostic, 31 adequate, and 5 good; DDMC images: 0 non-diagnostic, 6 adequate, and 40 good. CONCLUSION: The DDMC algorithm shows great promise in rubidium MPI PET with substantial improvements in image quality and the potential to salvage images considered non-diagnostic due to significant motion blurring.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Imagem de Perfusão do Miocárdio/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio
5.
J Nucl Cardiol ; 29(4): 1596-1606, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33608851

RESUMO

BACKGROUND: Motion of the heart is known to affect image quality in cardiac PET. The prevalence of motion blurring in routine cardiac PET is not fully appreciated due to challenges identifying subtle motion artefacts. This study utilizes a recent prototype Data-Driven Motion Correction (DDMC) algorithm to generate corrected images that are compared with non-corrected images to identify visual differences in relative rubidium-82 perfusion images due to motion. METHODS: 300 stress and 300 rest static images were reconstructed with DDMC and without correction (NMC). The 600 DDMC/NMC image pairs were assigned Visual Difference Score (VDS). The number of non-diagnostic images were noted. A "Dwell Fraction" (DF) was derived from the data to quantify motion and predict image degradation. RESULTS: Motion degradation (VDS = 1 or 2) was evident in 58% of stress images and 33% of rest images. Seven NMC images were non-diagnostic-these originated from six studies giving a 2% rate of non-diagnostic studies due to motion. The DF metric was able to effectively predict image degradation. The DDMC heart identification and tracking was successful in all images. CONCLUSION: Motion degradation is present in almost half of all relative perfusion images. The DDMC algorithm is a robust tool for predicting, assessing and correcting image degradation.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Artefatos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Movimento , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio
6.
Appl Opt ; 61(28): 8540-8552, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36256172

RESUMO

We report here the first implementation of chemically specific imaging in the exhaust plume of a gas turbine typical of those used for propulsion in commercial aircraft. The method used is chemical species tomography (CST) and the target species is CO2, absorbing in the near-infrared at 1999.4 nm. A total of 126 beams propagate transverse to the plume axis, along 7 m paths in a coplanar geometry, to probe a central region of diameter ≈1.5m. The CO2 absorption spectrum is measured using tunable diode laser spectroscopy with wavelength modulation, using the second harmonic to first harmonic (2f/1f) ratio method. The engine is operated over the full range of thrust, while data are recorded in a quasi-simultaneous mode at frame rates of 1.25 and 0.3125 Hz. Various data inversion methodologies are considered and presented for image reconstruction. At all thrust levels a persistent ring structure of high CO2 concentration is observed in the central region of the measurement plane, with a raised region in the middle of the plume assumed to be due to the engine's boat tail. With its potential to target various exhaust species, the CST method outlined here offers a new approach to turbine combustion research, turbine engine development, and aviation fuel research and development.

7.
J Nucl Cardiol ; 28(4): 1334-1346, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-31388967

RESUMO

BACKGROUND: Patient motion during pharmacological stressing can have substantial impact on myocardial blood flow (MBF) estimated from dynamic PET. This work evaluated a motion correction algorithm with and without adjustment of the PET attenuation map. METHODS: Frame-by-frame motion correction was performed by three users on 30 rubidium-82 studies. Data were divided equally into three groups of motion severity [mild (M1), moderate (M2) and severe (M3)]. MBF data were compared for non-motion corrected (NC), motion-corrected-only (MC) and with adjustment of the attenuation map (MCAC). Percentage differences of MBF were calculated in the coronary territories and 17-segment polar plots. Polar plots of spill-over were also generated from the data. RESULTS: Median differences of 23% were seen in the RCA and 18% for the LAD in the M3 category for MC vs NC images. Differences for MCAC vs MC images were considerably smaller and typically < 10%. Spill-over plots for MC and MCAC were notably more uniform compared with NC images. CONCLUSION: Motion correction for dynamic rubidium data is desirable for future MBF software updates. Adjustment of the PET attenuation map results in only marginal differences and therefore is unlikely to be an essential requirement. Assessing the uniformity of spill-over plots is a useful visual aid for verifying motion correction techniques.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária/fisiologia , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Doença da Artéria Coronariana/fisiopatologia , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Radioisótopos de Rubídio
8.
Emerg Radiol ; 28(5): 869-875, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33914184

RESUMO

PURPOSE: To analyze the change in utilization of healthcare resources through a review of ultrasound examinations performed in the emergency department of an urban healthcare system in NYC during the time of peak COVID-19 outbreak. METHODS: This is a retrospective review analyzing ED ultrasound exams performed by the radiology department of an urban healthcare system during the 8-week time period of the peak COVID-19 outbreak in NYC, compared to a time-matched period one year prior. Data regarding the examination type and indication were obtained in addition to patient demographics and indicators of outcomes including admission, length of stay, and mortality. RESULTS: There was a 58% decrease in ED ultrasounds performed by the radiology department during the COVID-19 time period. Exams performed during the pandemic compared to the pre-pandemic period were more likely to be performed on men (28.3 vs 18.0%, p < 0.01), older patients (36 vs. 35 years, p = 0.02), and patients subsequently admitted (17.8 vs. 13.4%, p = 0.03). There was also a difference in the distribution of exam type (p = 0.01). There was no difference in death, rate of surgery/intervention performed, or distribution of clinical indication. When correcting for gender, there was only an increase in studies leading to hospital admission in the female-only group (14.9 vs. 10.7%, p = 0.05). CONCLUSION: COVID-19 had a drastic impact on the utilization of emergency department ultrasounds performed by the radiology department, with a decrease in total exams performed and changes in patient demographics, including a higher proportion of male patients and increases in some markers of disease severity, including rate of hospital admission.


Assuntos
COVID-19 , Radiologia , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pandemias , Estudos Retrospectivos , SARS-CoV-2
9.
Bioorg Med Chem ; 28(20): 115696, 2020 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-33069065

RESUMO

Antibacterial drug resistance is a global health concern that requires multiple solution approaches including development of new antibacterial compounds acting at novel targets. Targeting regulatory RNA is an emerging area of drug discovery. The T-box riboswitch is a regulatory RNA mechanism that controls gene expression in Gram-positive bacteria and is an exceptional, novel target for antibacterial drug design. We report the design, synthesis and activity of a series of conformationally restricted oxazolidinone-triazole compounds targeting the highly conserved antiterminator RNA element of the T-box riboswitch. Computational binding energies correlated with experimentally-derived Kd values indicating the predictive capabilities for docking studies within this series of compounds. The conformationally restricted compounds specifically inhibited T-box riboswitch function and not overall transcription. Complex disruption, computational docking and RNA binding specificity data indicate that inhibition may result from ligand binding to an allosteric site. These results highlight the importance of both ligand affinity and RNA conformational outcome for targeted RNA drug design.


Assuntos
Antibacterianos/farmacologia , Descoberta de Drogas , Bactérias Gram-Positivas/efeitos dos fármacos , Oxazolidinonas/farmacologia , RNA Bacteriano/efeitos dos fármacos , Riboswitch/efeitos dos fármacos , Triazóis/farmacologia , Antibacterianos/síntese química , Antibacterianos/química , Relação Dose-Resposta a Droga , Bactérias Gram-Positivas/genética , Testes de Sensibilidade Microbiana , Conformação Molecular , Oxazolidinonas/química , RNA Bacteriano/metabolismo , Relação Estrutura-Atividade , Triazóis/química
10.
Neurosurg Rev ; 43(2): 425-441, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29998371

RESUMO

Spinal cord injury (SCI) is a life-shattering neurological condition that affects between 250,000 and 500,000 individuals each year with an estimated two to three million people worldwide living with an SCI-related disability. The incidence in the USA and Canada is more than that in other countries with motor vehicle accidents being the most common cause, while violence being most common in the developing nations. Its incidence is two- to fivefold higher in males, with a peak in younger adults. Apart from the economic burden associated with medical care costs, SCI predominantly affects a younger adult population. Therefore, the psychological impact of adaptation of an average healthy individual as a paraplegic or quadriplegic with bladder, bowel, or sexual dysfunction in their early life can be devastating. People with SCI are two to five times more likely to die prematurely, with worse survival rates in low- and middle-income countries. This devastating disorder has a complex and multifaceted mechanism. Recently, a lot of research has been published on the restoration of locomotor activity and the therapeutic strategies. Therefore, it is imperative for the treating physicians to understand the complex underlying pathophysiological mechanisms of SCI.


Assuntos
Traumatismos da Medula Espinal/epidemiologia , Traumatismos da Medula Espinal/patologia , Adulto , Idoso , Progressão da Doença , Humanos , Incidência , Pessoa de Meia-Idade , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/psicologia , Adulto Jovem
12.
J Nucl Cardiol ; 26(2): 405-412, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-28497418

RESUMO

BACKGROUND: Time-of-flight (TOF) is known to increase signal-to-noise ratio (SNR) and facilitate reductions in administered activity. Established measures of SNR gain are derived from areas of uniform uptake, which is not applicable to the heterogeneous uptake in cardiac PET images using fluoro-deoxyglucose (FDG). This study aimed to develop a technique to quantify SNR gains within the myocardium due to TOF. METHODS: Reference TOF SNR gains were measured in 88 FDG oncology patients. Phantom data were used to translate reference SNR gains and validate a method of quantifying SNR gains within the myocardium from parametric images produced from multiple replicate images. This technique was applied to 13 FDG cardiac viability patients. RESULTS: Reference TOF SNR gains of +23% ± 8.5% were measured in oncology patients. Measurements of SNR gain from the phantom data were in agreement and showed the parametric image technique to be sufficiently robust. SNR gains within the myocardium in the viability patients were +21% ± 2.8%. CONCLUSION: A method to quantify SNR gains from TOF within the myocardium has been developed and evaluated. SNR gains within the myocardium are comparable to those observed by established methods. This allows guidance for protocol optimization for TOF systems in cardiac PET.


Assuntos
Coração/diagnóstico por imagem , Miocárdio/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Fluordesoxiglucose F18 , Humanos , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Radioisótopos de Rubídio , Razão Sinal-Ruído
13.
J Nucl Cardiol ; 25(2): 596-605, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-27624818

RESUMO

BACKGROUND: Rubidium-82 myocardial perfusion imaging is a well-established technique for assessing myocardial ischemia. With continuing interest on myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurements, there is a requirement to fully appreciate the impact of technical aspects of the process. One such factor for rubidium-82 is prompt gamma compensation (PGC). This study aims to assess the impact of PGC on MBF and MFR calculated from dynamic Rb-82 data. METHODS: Dynamic rest and stress images were acquired on a Siemens Biograph mCT and reconstructed with and without PGC in 50 patients (29 male). MBF and MFR were measured in the three main coronary territories as well as globally. RESULTS: With PGC, statistically significant reductions in MBF were observed in LAD (-6.9%), LCx (-4.8%), and globally (-6.5%) but only in obese patients. Significant increases in MBF were observed in RCA (+6.4%) in only nonobese patients. In very obese patients, differences of up to 40% in MBF were observed between PGC and non-PGC images. In nearly all cases, similar PGC differences were observed at stress and rest so there were no significant differences in MFR; however, in a small number of very obese patients, differences in excess of 20% were observed. CONCLUSION: PGC results in statistically significant changes in MBF, with the greatest reductions observed in the LAD and LCx territories of obese patients. In most cases, the impact on stress and rest data is of similar relative magnitudes and changes to MFR are small.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Coração/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica , Imagem de Perfusão do Miocárdio , Miocárdio/patologia , Obesidade/complicações , Obesidade/diagnóstico por imagem , Radioisótopos de Rubídio
14.
J Nucl Cardiol ; 24(2): 596-604, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26809437

RESUMO

BACKGROUND: There is a growing focus on reducing radiation dose to patients undergoing myocardial perfusion imaging. This preliminary phantom study aims to evaluate the use of general-purpose collimators with resolution recovery (RR) to allow a reduction in patient radiation dose. METHODS: Images of a cardiac torso phantom with inferior and anterior wall defects were acquired on a GE Infinia and Siemens Symbia T6 using both high-resolution and general-purpose collimators. Imaging time, a surrogate for administered activity, was reduced between 35% and 40% with general-purpose collimators to match the counts acquired with high-resolution collimators. Images were reconstructed with RR with and without attenuation correction. Two pixel sizes were also investigated. Defect contrast was measured. RESULTS: Defect contrast on general-purpose images was superior or comparable to the high-resolution collimators on both systems despite the reduced imaging time. Infinia general-purpose images required a smaller pixel size to be used to maintain defect contrast, while Symbia T6 general-purpose images did not require a change in pixel size to that used for standard myocardial perfusion SPECT. CONCLUSION: This study suggests that general-purpose collimators with RR offer a potential for substantial dose reductions while providing similar or better image quality to images acquired using high-resolution collimators.


Assuntos
Imagem de Perfusão do Miocárdio/instrumentação , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Projetos Piloto , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Nucl Cardiol ; 23(6): 1457-1466, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-26403147

RESUMO

BACKGROUND: Quantitative assessment of [18F]-FDG PET/CT images has been shown to be useful in the diagnosis of cardiac implantable electronic device (CIED) infection. This study aimed to compare the accuracy of various quantitative methods, using the same patient cohort and to assess the utility of dual time point imaging. METHODS: The study comprised a retrospective review of 80 [18F]-FDG PET/CT studies. Of these, 41 were oncological patients with an asymptomatic CIED in situ (Group 1), and 39 were studies performed in patients with symptomatic devices. Of these, 14 were subsequently deemed on follow-up to be non-infected (Group 2), and 25 confirmed as infected post-device extraction (Group 3). Ratios of maximal uptake around the CIED in both the attenuation corrected and non-attenuation corrected images were calculated to regions of normal physiological uptake, along with the maximal standardized uptake value (SUVmax) alone. Receiver operating characteristic analysis was performed for all methods at both time points. Measurement reliability was assessed using the intraclass correlation coefficient (ICC). RESULTS: Using Group 1 as a reference, all methods gave an area under the curve (AUC) greater than 0.93. Using Group 2 as reference, the accuracy varied greatly, with AUC values ranging from 0.71 to 0.97. The hepatic blood pool (HBP) ratio gave the highest AUC values. The calculated ICC values for each method showed the SUVmax and HBP measurement to have the greatest reliability, with values of 1.0 and 0.97, respectively. CONCLUSIONS: Quantitation of [18F] FDG uptake was found to have a high degree of accuracy in confirming the diagnosis of CIED infection. Normalization to HBP uptake was found to give the greatest AUC and demonstrated excellent reliability. Inconsistencies from published data indicate that individual imaging centers should only use published data for guidance.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Fluordesoxiglucose F18/farmacocinética , Miocardite/etiologia , Miocardite/metabolismo , Marca-Passo Artificial/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocardite/diagnóstico por imagem , Infecções Relacionadas à Prótese/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
18.
J Nucl Cardiol ; 21(3): 467-74, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24477406

RESUMO

BACKGROUND: Myocardial flow reserve (MFR) obtained from dynamic cardiac positron emission tomography (PET) with rubidium-82 (Rb-82) has been shown to be a useful measurement in assessing coronary artery disease. Advanced PET reconstructions with point spread function modeling and time-of-flight have been shown to improve image quality but also have an impact on kinetic analysis of dynamic data. This study aims to determine the impact of these algorithms on MFR data. METHODS: Dynamic Rb-82 cardiac PET images from 37 patients were reconstructed with standard and advanced reconstructions. Area under curve (AUC) of the blood input function (BIF), myocardial blood flow (MBF) and MFR were compared with each reconstruction. RESULTS: No significant differences were seen in MFR for the two reconstructions. A relatively small mean difference in MBF data of +11.9% was observed with advanced reconstruction compared with the standard reconstruction but there was considerable variability in the degree of change (95% confidence intervals of -16.2% to +40.0%). Small systematic relative differences were seen for AUC BIF (mean difference of -6.3%; 95% CI -17.5% to +5.4%). CONCLUSION: MFR results from Rb-82 dynamic PET appear to be robust when generated by standard or advanced PET reconstructions. Considerable increases in MBF values may occur with advanced reconstructions, and further work is required to fully understand this.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Reserva Fracionada de Fluxo Miocárdico , Tomografia por Emissão de Pósitrons/métodos , Radioisótopos de Rubídio/farmacocinética , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Modelos Cardiovasculares , Modelos Estatísticos , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Am J Geriatr Psychiatry ; 21(12): 1239-43, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23602305

RESUMO

OBJECTIVES: Delirium is associated with an increased risk of long-term cognitive decline, suggesting the possibility of concurrent central nervous system (CNS) injury. S100B is a putative biomarker of CNS injury and elevated serum levels in delirium have been reported. Here we hypothesize that delirium is associated with raised concentrations of cerebrospinal fluid (CSF) S100B. METHODS: Forty-five patients with hip fracture aged over 60 and awaiting surgery under spinal anesthesia were assessed for delirium pre- and post-operatively. CSF S100B levels were measured in samples collected at the onset of surgery. RESULTS: Participants with pre-operative delirium (N = 8) had elevated Log10 CSF S100B (mean: -0.156; SD: 0.238) compared with those without delirium (mean: -0.306; SD: 0.162), Student's t-test t = 2.18, df = 43, p = 0.035. CONCLUSIONS: This study provides preliminary evidence of elevated CSF S100B in current delirium, consistent with findings in serum and with other studies showing elevated S100B in the presence of diverse forms of CNS injury.


Assuntos
Delírio/líquido cefalorraquidiano , Fraturas do Quadril/cirurgia , Subunidade beta da Proteína Ligante de Cálcio S100/líquido cefalorraquidiano , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/líquido cefalorraquidiano , Delírio/complicações , Feminino , Fraturas do Quadril/complicações , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA