Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
MAGMA ; 29(1): 17-27, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26530323

RESUMO

OBJECTIVES: Reproducibility of myocardial contour determination in cardiac magnetic resonance imaging is important, especially when determining T2* values per myocardial segment as a prognostic factor of heart failure or thalassemia. A method creating a composite image with contrasts optimized for drawing myocardial contours is introduced and compared with the standard method on a single image. MATERIALS AND METHODS: A total of 36 short-axis slices from bright-blood multigradient echo (MGE) T2* scans of 21 patients were acquired at eight echo times. Four observers drew free-hand myocardial contours on one manually selected T2* image (method 1) and on one image composed by blending three images acquired at TEs providing optimum contrast-to-noise ratio between the myocardium and its surrounding regions (method 2). RESULTS: Myocardial contouring by method 2 met higher interobserver reproducibility than method 1 (P < 0.001) with smaller Coefficient of variance (CoV) of T2* values in the presence of myocardial iron accumulation (9.79 vs. 15.91%) and in both global myocardial and mid-ventricular septum regions (12.29 vs. 16.88 and 5.76 vs. 8.16%, respectively). CONCLUSION: The use of contrast-optimized composite images in MGE data analysis improves reproducibility of myocardial contour determination, leading to increased consistency in the calculated T2* values enhancing the diagnostic impact of this measure of iron overload.


Assuntos
Meios de Contraste/química , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Adolescente , Adulto , Algoritmos , Feminino , Coração/fisiologia , Humanos , Ferro , Sobrecarga de Ferro/diagnóstico , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
2.
Eur Radiol ; 22(1): 144-51, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21842431

RESUMO

OBJECTIVES: To present an adapted Clinical Trial Processor (CTP) test set-up for receiving, anonymising and saving Digital Imaging and Communications in Medicine (DICOM) data using external input from the original database of an existing clinical study information system to guide the anonymisation process. METHODS: Two methods are presented for an adapted CTP test set-up. In the first method, images are pushed from the Picture Archiving and Communication System (PACS) using the DICOM protocol through a local network. In the second method, images are transferred through the internet using the HTTPS protocol. RESULTS: In total 25,000 images from 50 patients were moved from the PACS, anonymised and stored within roughly 2 h using the first method. In the second method, an average of 10 images per minute were transferred and processed over a residential connection. In both methods, no duplicated images were stored when previous images were retransferred. The anonymised images are stored in appropriate directories. CONCLUSIONS: The CTP can transfer and process DICOM images correctly in a very easy set-up providing a fast, secure and stable environment. The adapted CTP allows easy integration into an environment in which patient data are already included in an existing information system.


Assuntos
Ensaios Clínicos como Assunto/normas , Confidencialidade , Sistemas Computadorizados de Registros Médicos , Sistemas de Informação em Radiologia , Redes de Comunicação de Computadores , Bases de Dados como Assunto , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA