Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Diabetes Obes Metab ; 23(6): 1389-1396, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33606901

RESUMO

AIM: To evaluate the use of hybrid closed-loop glucose control with faster-acting insulin aspart (Fiasp) in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: In a double-blind, multinational, randomized, crossover study, 25 adults with T1D using insulin pump therapy (mean ± SD, age 38 ± 9 years, HbA1c 7.4% ± 0.8% [57 ± 8 mmol/mol]) underwent two 8-week periods of unrestricted living comparing hybrid closed-loop with Fiasp and hybrid closed-loop with standard insulin aspart in random order. During both interventions the CamAPS FX closed-loop system incorporating the Cambridge model predictive control algorithm was used. RESULTS: In an intention-to-treat analysis, the proportion of time sensor glucose was in the target range (3.9-10.0 mmol/L; primary endpoint) was not different between interventions (75% ± 8% vs. 75% ± 8% for hybrid closed-loop with Fiasp vs. hybrid closed-loop with standard insulin aspart; mean-adjusted difference -0.6% [95% CI -1.8% to 0.7%]; p < .001 for non-inferiority [non-inferiority margin 5%]). The proportion of time with sensor glucose less than 3.9 mmol/L (median [IQR] 2.4% [1.2%-3.2%] vs. 2.9% [1.7%-4.0%]; p = .01) and less than 3.0 mmol/L (median [IQR] 0.4% [0.2%-0.7%] vs. 0.7% [0.2%-0.9%]; p = .03) was reduced with Fiasp versus standard insulin aspart. There was no difference in mean glucose (8.1 ± 0.8 vs. 8.0 ± 0.8 mmol/L; p = .13) or glucose variability (SD of sensor glucose 2.9 ± 0.5 vs. 2.9 ± 0.5 mmol/L; p = .90). Total daily insulin requirements did not differ (49 ± 15 vs. 49 ± 15 units/day; p = .45). No severe hypoglycaemia or ketoacidosis occurred. CONCLUSIONS: The use of Fiasp in the CamAPS FX closed-loop system may reduce hypoglycaemia without compromising glucose control compared with standard insulin aspart in adults with T1D.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina Aspart , Adulto , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Insulina Aspart/uso terapêutico , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade
2.
Pediatr Diabetes ; 20(6): 794-799, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31140654

RESUMO

OBJECTIVE: To evaluate the experiences of families with very young children aged 1 to 7 years (inclusive) with type 1 diabetes using day-and-night hybrid closed-loop insulin delivery. METHODS: Parents/caregivers of 20 children aged 1 to 7 years with type 1 diabetes completed a closed-loop experience survey following two 3-week periods of unrestricted day-and-night hybrid closed-loop insulin therapy using Cambridge FlorenceM system at home. Benefits, limitations, and improvements of closed-loop technology were explored. RESULTS: Responders reported reduced burden of diabetes management, less time spent managing diabetes, and improved quality of sleep with closed-loop. Ninety percent of the responders felt less worried about their child's glucose control using closed-loop. Size of study devices, battery performance and connectivity issues were identified as areas for improvement. Parents/caregivers wished for more options to input information to the system such as temporary glucose targets. CONCLUSIONS: Parents/caregivers of very young children reported important quality of life benefits associated with using closed-loop, supporting adoption of this technology in this population.


Assuntos
Efeitos Psicossociais da Doença , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Qualidade de Vida , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia , Cuidadores/psicologia , Cuidadores/estatística & dados numéricos , Criança , Pré-Escolar , Ritmo Circadiano/fisiologia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/epidemiologia , Diabetes Mellitus Tipo 1/psicologia , Família/psicologia , Feminino , Humanos , Lactente , Insulina/efeitos adversos , Masculino , Pais/psicologia , Inquéritos e Questionários
3.
Diabetes Care ; 46(4): 757-764, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36710473

RESUMO

OBJECTIVE: To evaluate the pharmacokinetics, pharmacodynamics, and safety of a novel U500 insulin aspart formulation (AT278 U500) compared with insulin aspart (IAsp U100). RESEARCH DESIGN AND METHODS: This single-center, randomized, double-blind study was conducted in 38 men with type 1 diabetes (body weight ≤100 kg and total insulin dose <1.2 units/kg/day). Participants received a single dose of either AT278 U500 or IAsp U100 (0.3 units/kg s.c.) in a crossover design, followed by an 8-h euglycemic clamp in the absence of basal insulin. RESULTS: With AT278 U500, onset of appearance in serum was 6 min earlier (P < 0.0001) and reached 50% of maximum concentration 23 min faster (P < 0.0001). Insulin exposure with AT278 U500 was 4.0-fold higher within the first 30 min (95% CI 3.29, 4.90), 1.5-fold higher within the first 60 min (95% CI 1.35, 1.76), and statistically superior up to 90 min postdose (P < 0.05). With AT278 U500, onset of action was 10 min earlier (P < 0.0001) and reached 50% of maximum glucose infusion rate 20 min faster (P < 0.0001). The glucose-lowering effect with AT278 U500 was 8.9-fold higher within the first 30 min (95% CI 5.96, 17.46), 2.4-fold higher within the first 60 min (95% CI 1.92, 3.22), and statistically superior up to 2 h postdose (P < 0.0001). Overall insulin exposure and glucose-lowering effect were comparable. No significant safety findings were observed. CONCLUSIONS: AT278 U500 offers rapid-acting characteristics in a reduced dose volume, with accelerated absorption and onset of action compared with IAsp U100 in the studied population.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Insulina Aspart , Humanos , Masculino , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina Aspart/efeitos adversos , Insulina Aspart/farmacocinética , Insulina Aspart/farmacologia , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/farmacocinética , Hipoglicemiantes/farmacologia , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade
4.
Front Endocrinol (Lausanne) ; 12: 721028, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34456876

RESUMO

Background: Type 1 diabetes in young children is a heavy parental burden. As part of pilot phase of the KIDSAP01 study, we conducted a baseline assessment in parents to study the association between hypoglycemia fear, parental well-being and child behavior. Methods: All parents were invited to fill in baseline questionnaires: hypoglycemia fear survey (HFS), WHO-5, Epworth Sleepiness Scale and Strength and Difficulties Questionnaire (SDQ). Results: 24 children (median age: 5-year, range 1-7 years, 63% male, mean diabetes duration: 3 ± 1.7 years) participated. 23/24 parents filled out the questionnaires. We found a higher score for the hypoglycemia fear behavior 33.9 ± 5.6 compared to hypoglycemia worry 34.6 ± 12.2. Median WHO-5 score was 16 (8 - 22) with poor well-being in two parents. Median daytime sleepiness score was high in five parents (>10). For six children a high total behavioral difficulty score (>16) was reported. Pro social behavior score was lower than normal in six children (<6). Parental well-being was negatively associated with HFS total (r = - 0.50, p <.05) and subscale scores (r = - 0.44, p <.05 for HFS-Worry and HFS-Behavior), child behavior (r = - 0.45, p = .05) and positively with child age and diabetes duration (r = 0.58, p <.01, r = 0.6, p <.01). HFS, parental well-being nor daytime sleepiness are associated with the HbA1c. Conclusion: Regular screening of parental well-being, hypoglycemia fear and child behavior should be part of routine care to target early intervention.


Assuntos
Diabetes Mellitus Tipo 1/psicologia , Pais/psicologia , Adulto , Idade de Início , Ansiedade/epidemiologia , Ansiedade/psicologia , Criança , Comportamento Infantil/psicologia , Pré-Escolar , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Europa (Continente)/epidemiologia , Medo/psicologia , Feminino , Humanos , Hipoglicemia/prevenção & controle , Hipoglicemia/psicologia , Lactente , Insulina/administração & dosagem , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Masculino , Inquéritos e Questionários
5.
Diabetes Technol Ther ; 22(6): 468-475, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32048877

RESUMO

Background: We explored health professionals' views about the training, support, and resourcing needed to support people using closed-loop technology in routine clinical care to help inform the development of formal guidance. Methods: Interviews were conducted with health professionals (n = 22) delivering the Closed Loop from Onset in Type 1 Diabetes (CLOuD) trial after they had ≥6 months' experience of supporting participants using a closed-loop system. Data were analyzed descriptively. Results: Interviewees described how, compared with other insulin regimens, teaching and supporting individuals to use a closed-loop system could be initially more time-consuming. However, they also noted that after an initial adjustment period, users had less need for initiating contact with the clinical team compared with people using pumps or multiple daily injections. Interviewees highlighted how a lessened need for ad hoc clinical input could result in new challenges; specifically, they had fewer opportunities to reinforce users' diabetes knowledge and skills and detect potential psychosocial problems. They also observed heightened anxiety among some parents due to the constant availability of data and unrealistic expectations about the system's capabilities. Interviewees noted that all local diabetes teams should be empowered to deliver closed-loop system care, but stressed that health professionals supporting closed-loop users in routine care will need comprehensive technology training and standardized clinical guidance. Conclusion: These findings constitute an important starting point for the development of formal guidance to support the rollout of closed-loop technology. Our recommendations, if actioned, will help limit the potential additional burden of introducing closed-loop systems in routine clinical care and help inform appropriate user education and support.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Pessoal de Saúde/educação , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Automonitorização da Glicemia , Humanos , Pesquisa Qualitativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA