Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 115
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 47(3): 383-391, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38348921

RESUMO

OBJECTIVE: The presence of cannon A waves, the so called "frog sign", has traditionally been considered diagnostic of atrioventricular nodal re-entrant tachycardia (AVNRT). Nevertheless, it has never been systematically evaluated. The aim of this study is to assess the independent diagnostic utility of cannon A waves in the differential diagnosis of supraventricular tachycardias (SVTs). METHODS: We prospectively included 100 patients who underwent an electrophysiology (EP) study for SVT. The right jugular venous pulse was recorded during the study. In 61 patients, invasive central venous pressure (CVP) was registered as well. CVP increase is thought to be related with the timing between atria and ventricle depolarization; two groups were prespecified, the short VA interval tachycardias (including typical AVNRT and atrioventricular reciprocating tachycardia (AVRT) mediated by a septal accessory pathway) and the long VA interval tachycardias (including atypical AVNRT and AVRT mediated by a left free wall accessory pathway). RESULTS: The relationship between cannon A waves and AVNRT did not reach the statistical significance (OR: 3.01; p = .058); On the other hand, it was clearly associated with the final diagnosis of a short VA interval tachycardia (OR: 10.21; p < .001). CVP increase showed an inversely proportional relationship with the VA interval during tachycardia (b = -.020; p < .001). CVP increase was larger in cases of AVNRT (4.0 mmHg vs. 1.2 mmHg; p < .001) and short VA interval tachycardias (3.9 mmHg vs. 1.2 mmHg; p < .001). CONCLUSION: The presence of cannon A waves is associated with the final diagnosis of short VA interval tachycardias.


Assuntos
Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Paroxística , Taquicardia Supraventricular , Taquicardia Ventricular , Humanos , Taquicardia Supraventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Fascículo Atrioventricular , Taquicardia Ventricular/diagnóstico , Átrios do Coração , Diagnóstico Diferencial , Eletrocardiografia
2.
J Cardiovasc Electrophysiol ; 33(12): 2485-2495, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36168873

RESUMO

INTRODUCTION: Ablation of atrial fibrillation (AF) is usually not considered in patients with rheumatic mitral stenosis (RMS). We analyzed the results of a combined procedure of AF ablation and percutaneous balloon mitral commissurotomy (PBMC). METHODS: We prospectively included 22 patients with severe RMS to undergo a combined PBMC + AF ablation procedure. Noninvasive mapping of the atria was also performed. A historical sample of propensity-scored matched patients who underwent PBMC alone was used as controls. The primary endpoint was freedom from AF/AT at 1-year. Multivariate analysis evaluated sinus rhythm (SR) predictors. RESULTS: Successful pulmonary vein isolation and electrocardiographic imaging-based drivers ablation was performed in 20 patients following PBMC. At 1-year, 75% of the patients in the combined group were in SR compared to 40% in the propensity-score matched group (p = 0.004). The composite of AF recurrence, need for mitral surgery and all-cause mortality was also more frequent in the control group (65% vs. 30%; p = 0.005). Catheter ablation (odds ratio [OR] 1.58; 95% confidence interval [CI] [1.17-17.37]; p = 0.04) and AF type (OR 1.46; 95% CI [1.05-82.64]; p < 0.001) were the only independent predictors of SR at 1-year. Noninvasive mapping in the combined group showed that the number of simultaneous rotors (OR 2.10; 95% CI [1.41-10.2]; p = 0.04) was the only independent predictor of AF. CONCLUSION: A combined procedure of AF ablation and PBMC significantly increased the proportion of patients in sinus rhythm at 1-year. Noninvasive mapping may help to improve AF characterization and guide personalized AF treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Estenose da Valva Mitral , Cardiopatia Reumática , Humanos , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cardiopatia Reumática/diagnóstico , Cardiopatia Reumática/diagnóstico por imagem , Leucócitos Mononucleares , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
3.
Am J Physiol Heart Circ Physiol ; 320(4): H1337-H1347, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33513086

RESUMO

Although atrial fibrillation (AF) is the most common cardiac arrhythmia, its early identification, diagnosis, and treatment is still challenging. Due to its heterogeneous mechanisms and risk factors, targeting an individualized treatment of AF demands a large amount of patient data to identify specific patterns. Artificial intelligence (AI) algorithms are particularly well suited for treating high-dimensional data, predicting outcomes, and eventually, optimizing strategies for patient management. The analysis of large patient samples combining different sources of information such as blood biomarkers, electrical signals, and medical images opens a new paradigm for improving diagnostic algorithms. In this review, we summarize suitable AI techniques for this purpose. In particular, we describe potential applications for understanding the structural and functional bases of the disease, as well as for improving early noninvasive diagnosis, developing more efficient therapies, and predicting long-term clinical outcomes of patients with AF.


Assuntos
Inteligência Artificial , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Diagnóstico por Computador , Testes de Função Cardíaca , Terapia Assistida por Computador , Potenciais de Ação , Fibrilação Atrial/fisiopatologia , Tomada de Decisão Clínica , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Aprendizado de Máquina , Redes Neurais de Computação , Reconhecimento Automatizado de Padrão , Valor Preditivo dos Testes
4.
Europace ; 23(2): 254-263, 2021 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-33083813

RESUMO

AIMS: We determined the incidence and type of arrhythmias at 2-year follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: Multicentre prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR (SAPIEN XT/3: 53; CoreValve/Evolut R: 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted before hospital discharge and patients had continuous monitoring for up to 2 years. Arrhythmic events were adjudicated in a central core lab. 1836 new arrhythmic events (tachyarrhythmias: 1655 and bradyarrhythmias: 181) occurred at 2 years. Of these, 283 (15%) occurred beyond 1 year (tachyarrhythmias 212, bradyarrhythmias 71) in 33 (36%) patients, without differences between valve type. Most late (>1 year) arrhythmic events were asymptomatic (94%) and led to a treatment change in 17 (19%) patients. A total of 71 late bradyarrhythmias [high-degree atrioventricular block (HAVB): 3, severe bradycardia: 68] were detected in 17 (21%) patients. At 2 years, 18 (17%) patients had received a permanent pacemaker (PPM) or implantable cardiac-defibrillator. PPM implantation due to HAVB predominated in the early phase post-TAVR, with only 1 HAVB event requiring PPM implantation after 1 year. CONCLUSION: Patients with new-onset LBBB post-TAVR exhibited a very high burden of arrhythmic events within the 2 years post-procedure. While new tachyarrhythmic events were homogeneously distributed over time, the vast majority of new HAVB episodes leading to PPM implantation occurred early after the procedure. These results should help to guide the management of this challenging group of patients. (clinicaltrials.gov: NCT02153307).


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Humanos , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 44(3): 519-527, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33538337

RESUMO

BACKGROUND: Multipoint pacing (MPP) in cardiac resynchronization therapy (CRT) activates the left ventricle from two locations, thereby shortening the QRS duration and enabling better resynchronization; however, compared with conventional CRT, MPP reduces battery longevity. On the other hand, electrocardiogram-based optimization using the fusion-optimized intervals (FOI) method achieves more significant reverse remodeling than nominal CRT programming. Our study aimed to determine whether MPP could attain better resynchronization than single-point pacing (SPP) optimized by FOI. METHODS: This prospective study included 32 consecutive patients who successfully received CRT devices with MPP capabilities. After implantation, the QRS duration was measured during intrinsic rhythm and with three pacing configurations: MPP, SPP-FOI, and MPP-FOI. In 14 patients, biventricular activation times (by electrocardiographic imaging, ECGI) were obtained during intrinsic rhythm and for each pacing configuration to validate the findings. Device battery longevity was estimated at the 45-day follow-up. RESULTS: The SPP-FOI method achieved greater QRS shortening than MPP (-56 ± 16 vs. -42 ± 17 ms, p < .001). Adding MPP to the best FOI programming did not result in further shortening (MPP-FOI: -58 ± 14 ms, p = .69). Although biventricular activation times did not differ significantly among the three pacing configurations, only the two FOI configurations achieved significant shortening compared with intrinsic rhythm. The estimated battery longevity was longer with SPP than with MPP (8.1 ± 2.3 vs. 6.3 ± 2.0 years, p = .03). CONCLUSIONS: SPP optimized by FOI resulted in better resynchronization and longer battery duration than MPP.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Disfunção Ventricular Esquerda/terapia , Idoso , Ecocardiografia , Fontes de Energia Elétrica , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Disfunção Ventricular Esquerda/fisiopatologia
6.
Europace ; 20(8): 1334-1342, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29036312

RESUMO

Aims: Radiofrequency ablation (RFA) of septal accessory pathways (APs) is associated with a significant rate of first procedure failures and complications. Cryoablation is an alternative energy source but there are no studies comparing both ablation techniques. We aimed to systematically review the literature and compare the efficacy and safety of cryoablation vs. RFA of septal APs. Methods and results: We conducted two separate meta-analysis of cryoablation and RFA of septal APs and calculated the global estimates of the efficacy and safety. Sixty-four articles were included: 38 articles reporting RFA and 27 articles reporting cryoablation procedures. Additionally, we included the previously non-published cryoablation registry of septal APs performed at our institution. Overall, 4244 septal APs constitute our study population, 3495 in the RFA cohort and 749 in the cryoablation cohort. Acute procedural success rate of cryoablation was 86.0% (95% CI 81.6-89.4%) and RFA 89.0% (95% CI 86.8-91.0%). Recurrence rate of cryoablation was 18.1% (95% CI 14.8-21.8%) and RFA 9.9% (95% CI 8.2-12.0%). Long-term success rate after multiple ablation procedures of cryoablation was 75.9% (95% CI 68.2-82.3%) and RFA 88.4% (95% CI 84.7-91.3%). There were no reported cases of persistent atrioventricular block (AVB) with cryoablation and 2.7% (95% CI 2.2-3.4%) with RFA. Conclusion: Studies of RFA for treatment of septal APs report higher efficacy rates than do studies using cryoablation, but a significantly higher rate of AVB.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Ablação por Cateter , Criocirurgia , Feixe Acessório Atrioventricular/fisiopatologia , Potenciais de Ação , Adolescente , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/fisiopatologia , Ablação por Cateter/efeitos adversos , Criança , Pré-Escolar , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
7.
Circulation ; 133(12): 1189-98, 2016 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-26873943

RESUMO

BACKGROUND: Self-management interventions are widely implemented in the care for patients with heart failure (HF). However, trials show inconsistent results, and whether specific patient groups respond differently is unknown. This individual patient data meta-analysis assessed the effectiveness of self-management interventions in patients with HF and whether subgroups of patients respond differently. METHODS AND RESULTS: A systematic literature search identified randomized trials of self-management interventions. Data from 20 studies, representing 5624 patients, were included and analyzed with the use of mixed-effects models and Cox proportional-hazard models, including interaction terms. Self-management interventions reduced the risk of time to the combined end point of HF-related hospitalization or all-cause death (hazard ratio, 0.80; 95% confidence interval [CI], 0.71-0.89), time to HF-related hospitalization (hazard ratio, 0.80; 95% CI, 0.69-0.92), and improved 12-month HF-related quality of life (standardized mean difference, 0.15; 95% CI, 0.00-0.30). Subgroup analysis revealed a protective effect of self-management on the number of HF-related hospital days in patients <65 years of age (mean, 0.70 versus 5.35 days; interaction P=0.03). Patients without depression did not show an effect of self-management on survival (hazard ratio for all-cause mortality, 0.86; 95% CI, 0.69-1.06), whereas in patients with moderate/severe depression, self-management reduced survival (hazard ratio, 1.39; 95% CI, 1.06-1.83, interaction P=0.01). CONCLUSIONS: This study shows that self-management interventions had a beneficial effect on time to HF-related hospitalization or all-cause death and HF-related hospitalization alone and elicited a small increase in HF-related quality of life. The findings do not endorse limiting self-management interventions to subgroups of patients with HF, but increased mortality in depressed patients warrants caution in applying self-management strategies in these patients.


Assuntos
Insuficiência Cardíaca/terapia , Autocuidado , Idoso , Comorbidade , Depressão/epidemiologia , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/psicologia , Hospitalização/estatística & dados numéricos , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Autocuidado/psicologia , Resultado do Tratamento
8.
J Mol Cell Cardiol ; 99: 162-173, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27545043

RESUMO

MicroRNAs (miR) have considerable potential as therapeutic tools in cardiac diseases. Alterations in atrial miR are involved in the development of atrial fibrillation (AF), but the molecular mechanism underlying their contribution to atrial remodeling in chronic atrial fibrillation (CAF) is only partially understood. Here we used miR array to analyze the miR profile of atrial biopsies from sinus rhythm (SR) and CAF patients. qRT-PCR identified a distinctive CAF-miR signature and described conserved miR-208b upregulation in human and ovine AF atrial tissue. We used bioinformatics analysis to predict genes and signaling pathways as putative miR-208b targets, which highlighted genes from the cardiac muscle gene program and from canonical WNT, gap-junction and Ca2+ signaling networks. Results from analysis of miR-208b-overexpressing HL-1 atrial myocytes and from myocytes isolated from CAF patients showed that aberrant miR-208b levels reduced the expression and function of L-type Ca2+ channel subunits (CACNA1C and CACNB2) as well as the sarcoplasmic reticulum-Ca2+ pump SERCA2. These findings clearly pointed to CAF-specific upregulated miR-208b as an important mediator in Ca2+ handling impairment during atrial remodeling.


Assuntos
Fibrilação Atrial/genética , Fibrilação Atrial/metabolismo , Cálcio/metabolismo , Átrios do Coração/citologia , Átrios do Coração/metabolismo , MicroRNAs/genética , Miócitos Cardíacos/metabolismo , Regiões 3' não Traduzidas , Animais , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Sequência de Bases , Canais de Cálcio Tipo L/genética , Canais de Cálcio Tipo L/metabolismo , Linhagem Celular , Doença Crônica , Conexina 43/metabolismo , Perfilação da Expressão Gênica , Regulação da Expressão Gênica , Átrios do Coração/fisiopatologia , Humanos , Miosinas/genética , Ligação Proteica , Interferência de RNA , RNA Mensageiro/genética , ATPases Transportadoras de Cálcio do Retículo Sarcoplasmático/metabolismo , Ovinos , Proteínas Wnt/metabolismo
9.
J Cardiovasc Electrophysiol ; 27(4): 435-42, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26776725

RESUMO

INTRODUCTION: Ablation of high dominant frequency (DF) sources in patients with atrial fibrillation (AF) is an effective treatment option for paroxysmal AF. The aim of this study was to evaluate the accuracy of noninvasive estimation of DF and electrical patterns determination by solving the inverse problem of the electrocardiography. METHODS: Four representative AF patients with left-to-right and right-to-left atrial DF patterns were included in the study. For each patient, intracardiac electrograms from both atria were recorded simultaneously together with 67-lead body surface recordings. In addition to clinical recordings, realistic mathematical models of atria and torso anatomy with different DF patterns of AF were used. For both mathematical models and clinical recordings, inverse-computed electrograms were compared to intracardiac electrograms in terms of voltage, phase, and frequency spectrum relative errors. RESULTS: Comparison between intracardiac and inverse computed electrograms for AF patients showed 8.8 ± 4.4% errors for DF, 32 ± 4% for voltage, and 65 ± 4% for phase determination. These results were corroborated by mathematical simulations showing that the inverse problem solution was able to reconstruct the frequency spectrum and the DF maps with relative errors of 5.5 ± 4.1%, whereas the reconstruction of the electrograms or the instantaneous phase presented larger relative errors (i.e., 38 ± 15% and 48 ± 14 % respectively, P < 0.01). CONCLUSIONS: Noninvasive reconstruction of atrial frequency maps can be achieved by solving the inverse problem of electrocardiography with a higher accuracy than temporal distribution patterns.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Mapeamento Epicárdico/métodos , Modelos Cardiovasculares , Pericárdio/fisiopatologia , Algoritmos , Simulação por Computador , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Am J Physiol Heart Circ Physiol ; 309(11): H1964-73, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26408535

RESUMO

The objective of this article is to present an in vitro model of atrial cardiac tissue that could serve to study the mechanisms of remodeling related to atrial fibrillation (AF). We analyze the modification on gene expression and modifications on rotor dynamics following tissue remodeling. Atrial murine cells (HL-1 myocytes) were maintained in culture after the spontaneous initiation of AF and analyzed at two time points: 3.1 ± 1.3 and 9.7 ± 0.5 days after AF initiation. The degree of electrophysiological remodeling (i.e., relative gene expression of key ion channels) and structural inhomogeneity was compared between early and late cell culture times both in nonfibrillating and fibrillating cell cultures. In addition, the electrophysiological characteristics of in vitro fibrillation [e.g., density of phase singularities (PS/cm(2)), dominant frequency, and rotor meandering] analyzed by means of optical mapping were compared with the degree of electrophysiological remodeling. Fibrillating cell cultures showed a differential ion channel gene expression associated with atrial tissue remodeling (i.e., decreased SCN5A, CACN1C, KCND3, and GJA1 and increased KCNJ2) not present in nonfibrillating cell cultures. Also, fibrillatory complexity was increased in late- vs. early stage cultures (1.12 ± 0.14 vs. 0.43 ± 0.19 PS/cm(2), P < 0.01), which was associated with changes in the electrical reentrant patterns (i.e., decrease in rotor tip meandering and increase in wavefront curvature). HL-1 cells can reproduce AF features such as electrophysiological remodeling and an increased complexity of the electrophysiological behavior associated with the fibrillation time that resembles those occurring in patients with chronic AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Potenciais de Ação , Animais , Antiarrítmicos/farmacologia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/genética , Fibrilação Atrial/metabolismo , Remodelamento Atrial/efeitos dos fármacos , Canais de Cálcio Tipo L/genética , Canais de Cálcio Tipo L/metabolismo , Linhagem Celular , Conexina 43/genética , Conexina 43/metabolismo , Regulação da Expressão Gênica , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/metabolismo , Átrios do Coração/fisiopatologia , Camundongos , Modelos Cardiovasculares , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Canal de Sódio Disparado por Voltagem NAV1.5/metabolismo , Canais de Potássio Corretores do Fluxo de Internalização/genética , Canais de Potássio Corretores do Fluxo de Internalização/metabolismo , Canais de Potássio Shal/genética , Canais de Potássio Shal/metabolismo , Fatores de Tempo , Imagens com Corantes Sensíveis à Voltagem
13.
Biomed Eng Online ; 14: 59, 2015 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-26091857

RESUMO

BACKGROUND: Fast and accurate quality estimation of the electrocardiogram (ECG) signal is a relevant research topic that has attracted considerable interest in the scientific community, particularly due to its impact on tele-medicine monitoring systems, where the ECG is collected by untrained technicians. In recent years, a number of studies have addressed this topic, showing poor performance in discriminating between clinically acceptable and unacceptable ECG records. METHODS: This paper presents a novel, simple and accurate algorithm to estimate the quality of the 12-lead ECG by exploiting the structure of the cross-covariance matrix among different leads. Ideally, ECG signals from different leads should be highly correlated since they capture the same electrical activation process of the heart. However, in the presence of noise or artifacts the covariance among these signals will be affected. Eigenvalues of the ECG signals covariance matrix are fed into three different supervised binary classifiers. RESULTS AND CONCLUSION: The performance of these classifiers were evaluated using PhysioNet/CinC Challenge 2011 data. Our best quality classifier achieved an accuracy of 0.898 in the test set, while having a complexity well below the results of contestants who participated in the Challenge, thus making it suitable for implementation in current cellular devices.


Assuntos
Algoritmos , Eletrocardiografia , Processamento de Sinais Assistido por Computador , Artefatos , Humanos , Controle de Qualidade , Razão Sinal-Ruído , Aprendizado de Máquina Supervisionado
14.
Rev Esp Cardiol (Engl Ed) ; 77(1): 69-78, 2024 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37926340

RESUMO

Heart transplant (HT) remains the best therapeutic option for patients with advanced heart failure (HF). The allocation criteria aim to guarantee equitable access to HT and prioritize patients with a worse clinical status. To review the HT allocation criteria, the Heart Failure Association of the Spanish Society of Cardiology (HFA-SEC), the Spanish Society of Cardiovascular and Endovascular Surgery (SECCE) and the National Transplant Organization (ONT), organized a consensus conference involving adult and pediatric cardiologists, adult and pediatric cardiac surgeons, transplant coordinators from all over Spain, and physicians and nurses from the ONT. The aims of the consensus conference were as follows: a) to analyze the organization and management of patients with advanced HF and cardiogenic shock in Spain; b) to critically review heart allocation and priority criteria in other transplant organizations; c) to analyze the outcomes of patients listed and transplanted before and after the modification of the heart allocation criteria in 2017; and d) to propose new heart allocation criteria in Spain after an analysis of the available evidence and multidisciplinary discussion. In this article, by the HFA-SEC, SECCE and the ONT we present the results of the analysis performed in the consensus conference and the rationale for the new heart allocation criteria in Spain.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Adulto , Humanos , Criança , Espanha/epidemiologia , Insuficiência Cardíaca/cirurgia , Consenso , Choque Cardiogênico
15.
Front Physiol ; 14: 1057700, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36793415

RESUMO

Pulmonary vein isolation (PVI) is the most successful treatment for atrial fibrillation (AF) nowadays. However, not all AF patients benefit from PVI. In this study, we evaluate the use of ECGI to identify reentries and relate rotor density in the pulmonary vein (PV) area as an indicator of PVI outcome. Rotor maps were computed in a set of 29 AF patients using a new rotor detection algorithm. The relationship between the distribution of reentrant activity and the clinical outcome after PVI was studied. The number of rotors and proportion of PSs in different atrial regions were computed and compared retrospectively in two groups of patients: patients that remained in sinus rhythm 6 months after PVI and patients with arrhythmia recurrence. The total number of rotors obtained was higher in patients returning to arrhythmia after the ablation (4.31 ± 2.77 vs. 3.58 ± 2.67%, p = 0.018). However, a significantly higher concentration of PSs in the pulmonary veins was found in patients that remained in sinus rhythm (10.20 ± 12.40% vs. 5.19 ± 9.13%, p = 0.011) 6 months after PVI. The results obtained show a direct relationship between the expected AF mechanism and the electrophysiological parameters provided by ECGI, suggesting that this technology offers relevant information to predict the clinical outcome after PVI in AF patients.

16.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38000625

RESUMO

INTRODUCTION AND OBJECTIVES: There is limited evidence regarding the use of subcutaneous implantable cardioverter-defibrillators (S-ICD) in pediatric patients. The aim of this study was to determine the incidence of complications in these patients at our center, according to the type of ICD and patient size. METHODS: We included all patients aged<18 years who received an S-ICD since 2016 at our center. As a control group, we also included contemporary patients (since 2014) who received a transvenous ICD (TV-ICD). The primary endpoint was a composite of complications and inappropriate shocks. RESULTS: A total of 26 patients received an S-ICD (median age, 14 [5-17] years; body mass index [BMI], 20.2 kg/m2). Implantation was intermuscular in 23 patients (88%) and subserratus in the remainder. Two incisions were used in 24 patients (92%). In all patients, 2 zones were programmed: a conditional zone set at 230 (220-230) bpm, and a shock zone set at 250 bpm. Nineteen patients received a TV-ICD (median age, 11 [range, 5-16] years; BMI, 19.2 kg/m2, 79% single-chamber). Survival free from the primary endpoint at 5 years was 80% in the S-ICD group and 63% in the TV-ICD group (P=.54). Survival free from inappropriate shocks was similar (85% vs 89%, P=.86), while survival free from complications was higher in the S-ICD group (96% vs 57%, cloglog P=.016). There were no therapy failures in the S-ICD group, and no increased complication rates were observed in patients with BMI ≤20 kg/m2. CONCLUSIONS: With contemporary implantation techniques and programming, S-ICD is a safe and effective therapy in pediatric patients. The number of inappropriate shocks is similar to TV-ICD, with fewer short- and mid-term complications.

17.
Int J Cardiol ; 391: 131291, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37619880

RESUMO

BACKGROUND: Myocardial ischemia induces intracellular accumulation of non-glycosylated apolipoprotein J that results in a reduction of circulating glycosylated ApoJ (ApoJ-Glyc). The latter has been suggested to be a marker of transient myocardial ischemia. OBJECTIVE: This proof-of-concept clinical study aimed to assess whether changes in circulating ApoJ-Glyc could detect myocardial ischemia in patients attending the emergency department (ED) with chest pain suggestive of acute coronary syndrome (ACS). METHODS: In suspected ACS patients, EDICA (Early Detection of Myocardial Ischemia in Suspected Acute Coronary Syndromes by ApoJ-Glyc a Novel Pathologically based Ischemia Biomarker), a multicentre, international, cohort study assessed changes in 2 glycosylated variants of ApoJ-Glyc, (ApoJ-GlycA2 and ApoJ-GlycA6), in serum samples obtained at ED admission (0 h), and 1 h and 3 h thereafter, blinded to the clinical diagnosis (i.e. STEMI, NSTEMI, unstable angina, non-ischemic). RESULTS: 404 patients were recruited; 291 were given a clinical diagnosis of "non-ischemic" chest pain and 113 were considered to have had an ischemic event. ApoJ-GlycA6 was lower on admission in ischemic compared with "non-ischemic" patients (66 [46-90] vs. 73 [56-95] µg/ml; P = 0.04). 74% of unstable angina patients (all with undetectable hs-Tn), had ischemic changes in ApoJ-Glyc at 0 h and 89% at 1 h. Initially low ApoJ-Glyc levels in 62 patients requiring coronary revascularization increased significantly after successful percutaneous intervention. CONCLUSIONS: Circulating ApoJ-Glyc concentrations decrease early in ED patients with myocardial ischemia compared with "non-ischemic" patients, even in the absence of troponin elevations. ApoJ-Glyc may be a useful marker of myocardial ischemia in the ED setting.

18.
J Cardiovasc Electrophysiol ; 23(5): 506-14, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22151407

RESUMO

INTRODUCTION: The implantable cardioverter-defibrillator (ICD) electrogram (EG) is a documentation of ventricular tachycardia. We prospectively analyzed EGs from ICD electrodes located at the right ventricle apex to establish (1) ability to regionalize origin of left ventricle (LV) impulses, and (2) spatial resolution to distinguish between paced sites. METHODS AND RESULTS: LV electro-anatomic maps were generated in 15 patients. ICD-EGs were recorded during pacing from 22 ± 10 LV sites. Voltage of far-field EG deflections (initial, peak, final) and time intervals between far-field and bipolar EGs were measured. Blinded visual analysis was used for spatial resolution. Initial deflections were more negative and initial/peak ratios were larger for lateral versus septal and superior versus inferior sites. Time intervals were shorter for apical versus basal and septal versus lateral sites. Best predictive cutoff values were voltage of initial deflection <-1.24 mV, and initial/peak ratio >0.45 for a lateral site, voltage of final deflection <-0.30 for an inferior site, and time interval <80 milliseconds for an apical site. In a subsequent group of 9 patients, these values predicted correctly paced site location in 54-75% and tachycardia exit site in 60-100%. Recognition of paced sites as different by EG inspection was 91% accurate. Sensitivity increased with distance (0.96 if ≥ 2 cm vs 0.84 if < 2 cm, P < 0.001) and with presence of low-voltage tissue between sites (0.94 vs 0.88, P < 0.001). CONCLUSIONS: Standard ICD-EG analysis can help regionalize LV sites of impulse formation. It can accurately distinguish between 2 sites of impulse formation if they are ≥2 cm apart.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração/fisiopatologia , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/diagnóstico , Estimulação Cardíaca Artificial , Análise Discriminante , Desenho de Equipamento , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Espanha , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/terapia , Função Ventricular Esquerda
19.
Europace ; 14(11): 1560-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22696516

RESUMO

AIMS: Research on paroxysmal atrial fibrillation (AF) assumes that fibrillation induced by rapid pacing adequately reproduces spontaneously occurring paroxysmal AF in humans. We aimed to compare the spectral properties of spontaneous vs. induced AF episodes in paroxysmal AF patients. METHODS AND RESULTS: Eighty-five paroxysmal AF patients arriving in sinus rhythm to the electrophysiology laboratory were evaluated prior to ablation. Atrial fibrillation was induced by rapid pacing from the pulmonary vein-left atrial junctions (PV-LAJ), the coronary sinus (CS), or the high right atrium (HRA). Simultaneous recordings were obtained using multipolar catheters. Off-line power spectral analysis of 5 s bipolar electrograms was used to determine dominant frequency (DF) at recording sites with regularity index >0.2. Sixty-eight episodes were analysed for DF. Comparisons were made between spontaneous (n = 23) and induced (n = 45) AF episodes at each recording site. No significant differences were observed between spontaneous and induced AF episodes in HRA (5.18 ± 0.69 vs. 5.06 ± 0.91 Hz; P = 0.64), CS (5.27 ± 0.69 vs. 5.36 ± 0.76 Hz; P = 0.69), or LA (5.72 ± 0.88 vs. 5.64 ± 0.75 Hz; P = 0.7) regardless of pacing site. Consistent with these results, paired analysis in seven patients with both spontaneous and induced AF episodes, showed no regional DFs differences. Moreover, a left-to-right DF gradient was also present in both spontaneous (PV-LAJ 5.71 ± 0.81 vs. HRA 5.18 ± 0.69 Hz; P = 0.005) and induced (PV-LAJ 5.62 ± 0.72 vs. HRA 5.07 ± 0.91 Hz; P = 0.002) AF episodes, with no differences between them (P = not specific). CONCLUSION: In patients with paroxysmal AF, high-rate pacing-induced AF adequately mimics spontaneously initiated AF, regardless of induction site.


Assuntos
Fibrilação Atrial/diagnóstico , Estimulação Cardíaca Artificial , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação , Adulto , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Distribuição de Qui-Quadrado , Seio Coronário/fisiopatologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Imagens com Corantes Sensíveis à Voltagem
20.
Front Cardiovasc Med ; 9: 819429, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35387439

RESUMO

Background: Structural and post-ablation gender differences are reported in atrial fibrillation (AF). We analyzed the gender differences in structural remodeling and AF mechanisms in patients with persistent/long-lasting AF who underwent wide area circumferential pulmonary vein isolation (WACPVI). Materials and Methods: Ultra-high-density mapping was used to study atrial remodeling and AF drivers in 85 consecutive patients. Focal and rotational activity (RAc) were identified with the CartoFinder system and activation sequence analysis. The impact of RAc location on post-ablation outcomes was analyzed. Results: This study included 64 men and 21 women. RAc was detected in 73.4% of men and 38.1% of women (p = 0.003). RAc patients had higher left atrium (LA) voltage (0.64 ± 0.3 vs. 0.50 ± 0.2 mV; p = 0.01), RAc sites had higher voltage than non-RAc sites 0.77 ± 0.46 vs. 0.53 ± 0.37 mV (p < 0.001). Women had lower LA voltage than men (0.42 vs. 0.64 mV; p < 0.001), including pulmonary vein (PV) antra (0.16 vs. 0.30 mV; p < 0.001) and posterior wall (0.34 vs. 0.51 mV; p < 0.001). RAc in the posterior atrium was recorded in few women (23.8 vs. 54.7% in men; p = 0.014). AF recurrence rate was higher in patients with RAc outside WACPVI than those with all RAc inside WACPVI or no RAc (63.4 vs. 11.1 and 31.0%; p = 0.008 and p = 0.01). Comparison of selected patients using propensity score matching confirmed lower atrial voltage (0.4 ± 0.2 vs. 0.7 ± 0.3 mV; p = 0.007) and less RAc (38 vs. 75%; p = 0.02) in women. Conclusion: Women have shown more advanced structural remodeling at ablation, which is associated with a lower incidence of RAc (usually located outside the WACPVI). These findings could explain post-ablation gender differences.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA