Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Bases de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmology ; 129(6): 614-625, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35131359

RESUMO

PURPOSE: To evaluate safety and efficacy of a custom-manufactured artificial iris device (CustomFlex Artificial Iris; HumanOptics AG) for the treatment of congenital and acquired iris defects. DESIGN: Multicenter, prospective, unmasked, nonrandomized, interventional clinical trial. PARTICIPANTS: Patients with photophobia, sensitivity secondary to partial or complete congenital or acquired iris defects, or both. METHODS: Eyes were implanted from November 26, 2013, to December 1, 2017, with a custom, foldable artificial iris by 1 of 4 different surgical techniques. Patients were evaluated 1 day, 1 week, and 1, 3, 6, and 12 months after surgery. At each examination, slit-lamp findings, intraocular pressure, implant position, subjective visual symptoms, and complications were recorded. Corrected distance visual acuity (CDVA) and endothelial cell density (ECD) were measured at 3, 6, or 12 months as additional safety evaluations. The 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) was used to assess health-related quality of life affected by vision. The Global Aesthetic Improvement Scale was used to assess cosmetic results. MAIN OUTCOME MEASURES: Photosensitivity, glare, visual symptoms, NEI VFQ-25 score, Global Aesthetic Improvement Scale rating, prosthesis-related adverse events, intraocular lens (IOL)-related adverse events, and surgery-related adverse events 12 months after surgery. RESULTS: At the 12-month postoperative examination, a 59.7% reduction in marked to severe daytime light sensitivity (P < 0.0001), a 41.5% reduction in marked to severe nighttime light sensitivity (P < 0.0001), a 53.1% reduction in marked to severe daytime glare (P < 0.0001), and a 48.5% reduction in severe nighttime glare (P < 0.0001) were found. A 15.4-point improvement (P < 0.0001) in the NEI VFQ-25 total score was found, and 93.8% of patients reported an improvement in cosmesis as measured by the Global Aesthetic Improvement Scale 12 months after surgery. No loss of CDVA of > 2 lines related to the device was found. Median ECD loss was 5.3% at 6 months after surgery and 7.2% at 12 months after surgery. CONCLUSIONS: The artificial iris surpassed all key safety end points for adverse events related to the device, IOL, or implant surgery and met all key efficacy end points, including decreased light and glare sensitivity, improved health-related quality of life, and satisfaction with cosmesis. The device is safe and effective for the treatment of symptoms and an unacceptable cosmetic appearance created by congenital or acquired iris defects.


Assuntos
Iris , Implante de Lente Intraocular , Humanos , Iris/anormalidades , Iris/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Fotofobia/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estados Unidos , United States Food and Drug Administration
2.
Curr Opin Ophthalmol ; 27(3): 244-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26871656

RESUMO

PURPOSE OF REVIEW: This review examines the advantages and limitations of the various iris prostheses as treatment for aniridia. RECENT FINDINGS: Multiple prosthetic iris devices have been developed for implantation in eyes with aniridia. However, none is currently approved for use in the USA. SUMMARY: Aniridia can be congenital or traumatic in etiology and can lead to glare and other visual disturbances. Treatment options include colored contact lenses, corneal tattooing, and corneal stromal implants, although these carry significant risks of infection and corneal scarring. Prosthetic iris devices can often simultaneously treat aphakia or cataract as well as aniridia, and various models are currently available around the world from Morcher GMBH (Kapuzinerweg 12, 70374 Stuttgart, Germany), Ophtec USA Inc. (6421 Congress Ave Suite 12, Boca Raton, FL 33487, USA) and HumanOptics (Erlangen, Germany). Surgical planning and technique are important in optimizing the safety of these devices. The CustomFlex iris prosthesis from HumanOptics can be implanted within the capsular bag or ciliary sulcus with scleral fixation and offers excellent cosmetic outcomes. At present, the HumanOptics prosthetic iris is being investigated in a multicenter clinical trial.


Assuntos
Aniridia/cirurgia , Doenças da Íris/cirurgia , Humanos , Próteses e Implantes , Implantação de Prótese , Técnicas de Sutura , Acuidade Visual
3.
J Glaucoma ; 33(1): 55-58, 2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37523651

RESUMO

Herein we describe 2 cases of persistent mydriasis after gonioscopy-assisted transluminal trabeculotomy for open angle glaucoma. Both surgeries were uneventful, but the patients experienced postoperative hyphema and intraocular pressure elevation. They then developed persistent fixed and dilated pupils resistant to pilocarpine that led to intolerable photosensitivity and glare. An iris cerclage pupilloplasty was performed with adequate relief of symptoms in one case.


Assuntos
Glaucoma de Ângulo Aberto , Midríase , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular , Seguimentos , Resultado do Tratamento , Gonioscopia , Midríase/diagnóstico , Midríase/etiologia , Midríase/cirurgia , Estudos Retrospectivos , Doença Crônica
4.
Clin Ophthalmol ; 18: 1525-1534, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38827771

RESUMO

Purpose: To evaluate dry eye disease (DED) signs and symptoms six months after a single treatment with Localized Heat Therapy (LHT) (TearCare, Sight Sciences) for patients previously treated for six months with cyclosporine (0.05%) ophthalmic emulsion (CsA) BID (Restasis, Allergan). Setting: Nineteen ophthalmic and optometric practices in 11 US states. Design: Multicenter, cross-over, six month extension to the SAHARA randomized, controlled trial (RCT). Included patients were those randomized to CsA in Phase 1 of the SAHARA RCT. Methods: This was the second phase of the SAHARA RCT in which, following the 6-month endpoint, all patients that had been randomized to CsA discontinued CsA and were treated with LHT and subsequently followed for an additional six months. Outcome measures at 12 months for CsA patients crossed over to LHT included TBUT, OSDI and MGSS. Results: One hundred and sixty-one patients (322 eyes) were analyzed. Mean (SD) baseline TBUT prior to CsA was 4.4 (1.2) seconds, 5.6 (2.6) at 6 months which improved to 6.6 (3.2) and 6.1 (2.8) seconds (both P < 0.001) at 9 and 12 months (3, 6 months post LHT). Mean (SD) OSDI was 50.0 (14.9) at baseline and 34.2 (21.5) after CsA. With LHT at 6 months, this improved to 30.0 (20.6) and 31.0 (19.5) at 9 and 12 months (P = 0.162 vs month 6, P < 0.0001 vs baseline). MGSS was 7.1 (3.2) at baseline, 13.3 (8.2) at the end of CsA treatment which improved to 17.4 (8.8) and 16.1 (9.0) at 9 and 12 months; both P <0.001. Conclusion: SAHARA showed 6-month superiority of LHT to CsA in clinical signs and non-inferiority in symptom scores. This extension shows that patients treated with CsA for 6 months can achieve meaningful additional improvement in signs and symptoms lasting for as long as 6 months following a single LHT treatment without the need for topical prescription therapy.

5.
Can J Ophthalmol ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38815959

RESUMO

OBJECTIVE: To compare clinical outcomes of combined pars plana vitrectomy (PPV) and secondary scleral fixation of an intraocular lens (IOL) using Gore-Tex suture versus flanged intrascleral haptic fixation (FIHF) using double needles. DESIGN: Single-centre retrospective cohort series. PARTICIPANTS: Eyes undergoing PPV with simultaneous scleral fixation of an IOL. METHOD: Eyes that underwent fixation of a Bausch & Lomb Akreos AO60 or enVista MX60E IOL using Gore-Tex suture or a Tecnis ZA9003 or Zeiss CT LUCIA 602 IOL using FIHF were included. The primary outcome was change from baseline visual acuity to postoperative month 3. Secondary outcomes included deviation from refractive target aim and rates of postoperative complications. RESULTS: Seventy-nine eyes of 72 patients were included. Mean (±SD) follow-up was 16 ± 10.5 months (range, 4.5-45.2 months). Fifty-three eyes (67.1%) underwent Gore-Tex suture fixation, and 26 eyes (32.9%) underwent FIHF. Across all eyes, mean visual acuity improved from 1.30 ± 0.74 logMAR (20/399 Snellen equivalent) preoperatively to 0.36 ± 0.36 logMAR (20/45 Snellen equivalent) at 3 months (p < 0.001). No difference in visual acuity at month 3 was noted between the 2 techniques (p = 0.34). Mean deviation from refractive target aim was not significantly different between the Gore-Tex and FIHF groups (+0.14 ± 1.33 D vs -0.16 ± 0.88 D; p = 0.45). Reoperation rates were similar between groups (2 of 53 eyes in the Gore-Tex group vs 3 of 26 eyes in the FIHF group; p = 0.32). CONCLUSION: Combined PPV and scleral fixation of IOLs with Gore-Tex suture and FIHF resulted in similar improvements in visual acuity. No significant differences in refractive outcome and postoperative complication profiles were noted.

6.
J Cataract Refract Surg ; 50(8): 876-882, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38350160

RESUMO

Blepharitis is a common ophthalmic condition with multiple etiologies and no definitive, universal treatment. The treatment modalities for managing lid margin diseases vary depending on the disease's cause, location, and severity. For anterior blepharitis, management options include eyelid hygiene with warm compresses, eyelid scrubs, baby shampoo, and over-the-counter eyelid cleansers. Topical antibiotics and antibiotic-steroid combination drops/ointments for the eye and eyelid may accompany these. For posterior blepharitis/meibomian gland dysfunction (MGD), at-home warm compress or in-office administration of heat therapy/thermal pulsation treatment that aims to clear obstruction in the meibomian glands and restore meibum secretions to maintain a healthy tear film is recommended. In addition to the above treatment strategies, various other compounds to manage lid margin diseases are in the late stages of development. This review summarizes the available treatment modalities or those in the pipeline for treating blepharitis and MGD.


Assuntos
Blefarite , Disfunção da Glândula Tarsal , Humanos , Blefarite/terapia , Blefarite/fisiopatologia , Disfunção da Glândula Tarsal/terapia , Disfunção da Glândula Tarsal/fisiopatologia , Antibacterianos/uso terapêutico , Glândulas Tarsais/fisiopatologia , Medicina Baseada em Evidências
7.
J Cataract Refract Surg ; 50(8): 868-875, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38758201

RESUMO

The eyelid margin is vital to ocular surface integrity. Much peer-reviewed literature has been established in eyelid margin inflammation, better known as blepharitis. The purpose was to review and understand the impact of eyelid margin disease. Anterior blepharitis causes inflammation at the eyelash base, ciliary follicles, and the palpebral skin. Posterior blepharitis occurs when there is inflammation with the posterior eyelid margin disease. In common usage, the term "blepharitis" used alone almost always refers to anterior blepharitis. Classification of eyelid margin disease should be based on etiopathogenesis, location, primary vs secondary, and chronicity. Blepharitis has several etiopathologies (infectious, inflammatory, and squamous). Meibomian gland dysfunction (MGD) can refer to the functional and/or structural problems with the meibomian gland. Meibomitis (or meibomianitis) occurs when there is inflammation associated with the MGD. The presence of blepharitis and/or MGD (with or without inflammation) can affect the ocular surface and thereby affect anterior segment and cataract surgeries. This review article evaluates the differential diagnoses of eyelid margin disease, including various forms of blepharitis, MGD, and meibomitis.


Assuntos
Blefarite , Humanos , Blefarite/diagnóstico , Glândulas Tarsais/patologia , Glândulas Tarsais/diagnóstico por imagem , Doenças Palpebrais/diagnóstico , Pálpebras/patologia , Disfunção da Glândula Tarsal/diagnóstico , Diagnóstico Diferencial
8.
Eye Contact Lens ; 39(5): 341-7, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23945524

RESUMO

OBJECTIVE: To evaluate the indications and outcomes of sutureless amniotic membrane transplant (AMT; ProKera) in the management of ocular surface disorders. METHODS: Chart review of patients who had ProKera (Bio-Tissue, Inc.) implantation for ocular surface disorders between June 2008 and May 2012 at 3 ophthalmology practices in Philadelphia, PA. The parameters evaluated included age, sex, indication for AMT, any other combined procedure, duration of retention of amniotic membrane, the effect of amniotic membrane on ocular surface healing, follow-up time, and complications. RESULTS: There were 35 eyes of 33 patients with a mean age of 68.2±19.5 years (range: 17-99 years). There were 25 male patients, and median follow-up was 110 days (mean: 164.6 days; range: 30-960 days). The indication for insertion of ProKera was nonhealing corneal ulcers of infective origin (group 1) in 9 eyes (25.7%), neurotrophic keratopathy (group 2) in 11 eyes (31.4%), chemical injury (group 3) in 5 eyes (14.3%), and other indications (group 4) in 10 eyes (28.6%). Complete or partial success was seen in a total of 44%, 64%, 80%, and 70% eyes in groups 1 to 4, respectively. Discomfort with the device was seen in 6 (17.1%) of 35 eyes, and recurrence of primary pathologic condition occurred in 5 (14.3%) of 35 eyes. CONCLUSION: ProKera treatment is easy to use and reasonably well tolerated, with moderate success in corneal ulcers and encouraging results in acute moderate chemical injury. Recurrence of primary pathologic condition is seen particularly associated with neurotrophic keratitis and dry eye syndrome.


Assuntos
Âmnio/transplante , Doenças da Córnea/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Queimaduras Químicas/cirurgia , Úlcera da Córnea/cirurgia , Queimaduras Oculares/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Técnicas de Sutura , Adulto Jovem
9.
J Cataract Refract Surg ; 49(5): 545-550, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37088938

RESUMO

A 61-year-old man presented with gradual blurring of vision and glare in both eyes for a couple of years, with worsening of the vision in his right eye over the past 2 months. He had no medical history of note. On clinical examination, his visual acuities were 20/80 in the right eye and 20/30 in the left eye, uncorrected. The cornea was clear, and the anterior chamber (AC) was deep in both eyes. He had bilateral mild nuclear sclerosis with round central onion-ring-like posterior opacities. The opacities measured approximately 2 mm in diameter and were marginally larger in the right eye than in the left eye (Figure 1JOURNAL/jcrs/04.03/02158034-202305000-00018/figure1/v/2023-04-20T184543Z/r/image-tiff). In addition, there were 2 curvilinear lines across the right posterior capsule (PC), one of which passed across the lens opacity (Figure 2JOURNAL/jcrs/04.03/02158034-202305000-00018/figure2/v/2023-04-20T184543Z/r/image-tiff). Fundus examination was normal in both eyes, and the vitreous was clear. Optical coherence tomography (OCT) of the macular and optic nerve in both eyes was normal. The endothelial cell count in both eyes exceeded 2000 cells/mm2. He had been told by a previous ophthalmologist to have bilateral cataracts and was now keen for surgery starting with the right eye. He works as a manager in a large company and is an avid golf player. He is emmetropic and wears spectacles for near work. Optical biometry using predicated posterior corneal astigmatism did not recommend a toric intraocular lens (IOL). He had done his internet research on IOL options and requested trifocal IOLs. What is your surgical plan for right cataract removal? Explain which IOL you would choose to implant.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Masculino , Humanos , Pessoa de Meia-Idade , Implante de Lente Intraocular/métodos , Complicações Pós-Operatórias , Catarata/complicações , Catarata/diagnóstico , Extração de Catarata/métodos
10.
Clin Ophthalmol ; 17: 2083-2096, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37521151

RESUMO

Background: Ophthalmic viscosurgical devices (OVDs) are commonly used during cataract surgery to protect the corneal endothelium. A systematic literature review and meta-analysis were conducted to assess the clinical evidence of OVDs composed of chondroitin sulfate-hyaluronic acid (CS-HA) versus other OVDs in maintaining endothelial cell density (ECD) and corneal thickness (CT). Methods: MEDLINE and EMBASE databases were searched from 2000 to 2020. Randomized controlled trials (RCTs, N ≥ 20 per group) comparing an OVD containing CS-HA (ie, VISCOAT®, DuoVisc® or DisCoVisc®) to any other OVD were included. The identified comparators were limited to the OVDs found in the literature, which included those composed of HA-only or hydroxypropyl methylcellulose (HPMC). Outcomes of focus included changes in ECD (baseline to 3 months) and CT (baseline to 24 hours). Meta-analyses were performed using R software, to assess mean differences (MD) in ECD and CT change between CS-HA OVDs and HA-only or HPMC OVDs. Results: A total of 966 abstracts were screened, and data were extracted from 12 RCTs. Meta-analyses using a random-effects model revealed significantly lower percent (%) decrease in ECD for CS-HA OVDs compared to both HA-only (MD: -4.10%; 95% CI: -5.81 to -2.40; p < 0.0001; 9 studies) and HPMC (MD: -6.47%; 95% CI: -10.41 to -2.52; p = 0.001; 2 studies) products. Similarly, % CT increase was significantly lower with CS-HA than with HA-only OVDs (MD: -3.22%; 95% CI: -6.24% to -0.20%; p = 0.04; 4 studies). However, there were no significant differences when comparing % CT change between CS-HA and HPMC OVDs (MD: 2.65%; 95% CI: -0.43% to 0.95%; p = 0.4; 2 studies). Conclusion: CS-HA OVDs lead to less postoperative loss of endothelial cells and may better protect corneal endothelium during cataract surgery, relative to other OVDs. Future randomized studies may be needed to solidify these findings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA