Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

Bases de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 47(6): 853-861, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38655610

RESUMO

AIMS: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome. METHODS: From our prospective PM and ICD implantation registry, all patients who underwent PM and/or ICD implantations at our center were analyzed. Patient characteristics and outcomes of PM patients with subsequent ICD upgrade were compared to age- and sex-matched patients with de novo ICD implantation, and to PM patients without subsequent upgrade. RESULTS: Of 1'301 ICD implantations, 60 (5%) were upgraded from PMs. Median time from PM implantation to ICD upgrade was 2.6 years (IQR 1.3-5.4). Of 2'195 PM patients, 28 patients underwent subsequent ICD upgrades, corresponding to an estimated annual incidence of an ICD upgrade of at least 0.33%. Lower LVEF (p = .05) and male sex (p = .038) were independent predictors for ICD upgrade. Survival without death, transplant and LVAD implantation were worse both for upgraded ICD patients compared to matched patients with de novo ICD implantation (p = .05), as well as for PM patients with subsequent upgrade compared to matched PM patients not requiring an upgrade (p = .036). CONCLUSIONS: One of 20 ICD implantations are upgrade of patients with a PM. At least one of 30 PM patients will require an ICD upgrade in the following 10 years. Predictors for ICD upgrade are male sex and lower LVEF at PM implantation. Upgraded patients have worse outcomes.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Masculino , Feminino , Idoso , Resultado do Tratamento , Estudos Prospectivos , Sistema de Registros , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida
2.
J Cardiovasc Electrophysiol ; 34(2): 292-299, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36490307

RESUMO

INTRODUCTION: Contact force sensing catheters are widely used for ablation of cardiac arrhythmias. They allow quantification of catheter-to-tissue contact, which is an important determinant for lesion formation and may reduce the risk of complications. The accuracy of these sensors may vary across the measurement range, catheter-to-tissue angle, and amongst manufacturers. We aim to compare the accuracy and reproducibility of four different force sensing ablation catheters. METHODS: A measurement setup containing a heated saline water bath with an integrated force measurement unit was constructed and validated. Subsequently, we investigated four different catheter models, each equipped with a unique measurement technology: Tacticath Quartz (Abbott), AcQBlate Force (Biotronik/Acutus), Stablepoint (Boston Scientific), and Smarttouch SF (Biosense Webster). For each model, the accuracy of three different catheters was measured within the range of 0-60 g and at contact angles of 0°, 30°, 45°, 60°, and 90°. RESULTS: In total, 6685 measurements were performed using 4 × 3 catheters (median of 568, interquartile range: 511-606 measurements per catheter). Over the entire measurement-range, the force measured by the catheters deviated from the real force by the following absolute mean values: Tacticath 1.29 ± 0.99 g, AcQBlate Force 2.87 ± 2.37 g, Stablepoint 1.38 ± 1.29 g, and Smarttouch 2.26 ± 2.70 g. For some models, significant under- and overestimation of >10 g were observed at higher forces. Mean absolute errors of all models across the range of 10-40 g were <3 g. CONCLUSION: Contact measured by force-sensing catheters is accurate with 1-3 g deviation within the range of 10-40 g. Significant errors can occur at higher forces with potential clinical consequences.


Assuntos
Ablação por Cateter , Catéteres , Humanos , Reprodutibilidade dos Testes , Desenho de Equipamento , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Cateteres Cardíacos
3.
Pacing Clin Electrophysiol ; 46(10): 1186-1196, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37616339

RESUMO

BACKGROUND: Prediction of the chamber of origin in patients with outflow tract ventricular arrhythmias (OTVA) remains challenging. A clinical risk score based on age, sex and presence of hypertension was associated with a left ventricular outflow tract (LVOT) origin. We aimed to validate this clinical score to predict an LVOT origin in patients with OTVA. METHODS: In a two-center observational cohort study, unselected patients undergoing catheter ablation (CA) for OTVA were enrolled. All procedures were performed using an electroanatomical mapping system. Successful ablation was defined as a ≥80% reduction of the initial overall PVC burden after 3 months of follow-up. Patients with unsuccessful ablation were excluded from this analysis. RESULTS: We included 187 consecutive patients with successful CA of idiopathic OTVA. Mean age was 52 ± 15 years, 102 patients (55%) were female, and 74 (40%) suffered from hypertension. A LVOT origin was found in 64 patients (34%). A score incorporating age, sex and presence of hypertension reached 73% sensitivity and 67% specificity for a low (0-1) and high (2-3) score, to predict an LVOT origin. The combination of one ECG algorithm (V2 S/V3 R-index) with the clinical score resulted in a sensitivity and specificity of 81% and 70% for PVCs with R/S transition at V3 . CONCLUSION: The published clinical score yielded a lower sensitivity and specificity in our cohort. However, for PVCs with R/S transition at V3, the combination with an existing ECG algorithm can improve the predictability of LVOT origin.

4.
Pacing Clin Electrophysiol ; 46(5): 365-375, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36912446

RESUMO

BACKGROUND: The implantation procedure of left ventricular (LV) leads and the management of cardiac resynchronization therapy (CRT) patients can be challenging. The IS-4 standard for CRT offers additional pacing vectors compared to bipolar leads (IS-1). IS-4 leads improve procedural outcome and may also result in lower adverse events during follow-up (FU) and improve clinical outcome in CRT patients. Further long-term FU data comparing the two lead designs are necessary. METHODS: In this retrospective, single-center study we included adult patients implanted with a CRT-Defibrillator (CRT-D) or CRT-Pacemaker (CRT-P) with a quadripolar (IS-4 group) or bipolar (IS-1 group) LV lead and with available ≥3 years clinical FU. The combined primary endpoint was a combination of predefined, lead-related adverse events. Secondary endpoints were all single components of the primary endpoint. RESULTS: Overall, 133 patients (IS-4 n = 66; IS-1 n = 67) with a mean FU of 4.03 ± 1.93 years were included. Lead-related adverse events were less frequent in patients with an IS-4 lead than with an IS-1 lead (n = 8, 12.1% vs. n = 23, 34.3%; p = .002). The secondary outcomes showed a lower rate of LV lead deactivation/explantation and LV lead dislodgement/dysfunction (4.5% vs. 22.4%; p = .003; 4.5% vs. 17.9%; p = .015, respectively) in the IS-4 patient group. Less patients suffered from unresolved phrenic nerve stimulation with an IS-4 lead (3.0% vs. 13.4%; p = .029). LV lead-related re-interventions were fewer in case of an IS-4 lead (6.1% vs. 17.9%; p = .036). CONCLUSION: In this retrospective analysis, the IS-4 LV lead is associated with lower lead-related complication rates than the IS-1 lead at long-term FU.


Assuntos
Transtorno Bipolar , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Adulto , Humanos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Estudos Retrospectivos , Transtorno Bipolar/terapia , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia , Sistema de Registros , Eletrodos Implantados
5.
J Cardiovasc Electrophysiol ; 33(7): 1617-1627, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35614867

RESUMO

INTRODUCTION: Conventional transvenous pacemaker leads may interfere with the tricuspid valve leaflets, tendinous chords, and papillary muscles, resulting in significant tricuspid valve regurgitation (TR). Leadless pacemakers (LLPMs) theoretically cause less mechanical interference with the tricuspid valve apparatus. However, data on TR after LLPM implantation are sparse and conflicting. Our goal was to investigate the prevalence of significant TR before and after LLPM implantation. METHODS: Patients who received a leadless LLPM (Micra™ TPS, Medtronic) between May 2016 and May 2021 at our center were included in this observational study if they had at least a pre- and postinterventional echocardiogram (TTE). The evolution of TR severity was assessed. Following a systematic literature review on TR evolution after implantation of a LLPM, data were pooled in a random-effects meta-analysis. RESULTS: We included 69 patients (median age 78 years [interquartile range (IQR) 72-84 years], 26% women). Follow-up duration between baseline and follow-up TTE was 11.4 months (IQR 3.5-20.1 months). At follow-up, overall TR severity was not different compared to baseline (p = .49). Six patients (9%) had new significant TR during follow-up after LLPM implantation, whereas TR severity improved in seven patients (10%). In the systematic review, we identified seven additional articles that investigated the prevalence of significant TR after LLPM implantation. The meta-analysis based on 297 patients failed to show a difference in significant TR before and after LLPM implantation (risk ratio 1.22, 95% confidence interval 0.97-1.53, p = .11). CONCLUSION: To date, there is no substantial evidence for a significant change in TR after implantation of a LLPM.


Assuntos
Marca-Passo Artificial , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Observacionais como Assunto , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/epidemiologia
6.
Europace ; 24(8): 1248-1255, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35699395

RESUMO

AIMS: To validate the performance of a multipolar pulsed-field ablation (PFA) catheter compared to a standard pentaspline 3D-mapping catheter for endpoint assessment of pulmonary vein isolation (PVI). PFA for PVI using single-shot devices combines the benefits of high procedural efficacy and safety. A newly available multipolar PFA catheter allows real-time recording of pulmonary vein (PV) signals during PVI. METHODS AND RESULTS: Patients undergoing first PVI using PFA with the standard ablation protocol (eight applications per PV) were studied. Entrance and exit block (10 V/2 ms) were assessed using the PFA catheter. Subsequently, a high-density 3D electroanatomical bipolar voltage map (3D-EAM) was constructed using a standard pentaspline 3D-mapping catheter. Additional PFA applications were delivered only after confirmation of residual PV connection by 3D-EAM. In 56 patients, 213 PVs were targeted for ablation. Acute PVI was achieved in 100% of PVs: in 199/213 (93%) PVs with the standard ablation protocol alone and in the remaining 14 PVs after additional PFA applications. The accuracy of PV assessment with the PFA catheter after the standard ablation protocol was 91% (194/213 veins). In 5/213 (2.3%) PVs, the PFA catheter incorrectly indicated PV-isolation. In 14/213 (6.6%), the PFA catheter incorrectly indicated residual PV-conduction due to high-output pace-capture. Lowering the output to 5 V/1 ms reduced this observation to 0.9% (2/213) and increased the overall accuracy to 97% (206/213). CONCLUSION: A novel multipolar PFA catheter allows reliable endpoint assessment for PVI. Due to its design, far-field sensing and high-output pace-capture can occur. Lowering the pacing output increases the accuracy from 91 to 97%.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
7.
Europace ; 24(12): 1926-1932, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-35727739

RESUMO

AIMS: The aim of the study was to compare the 1-year efficacy and safety of a novel cryoballoon (NCB) ablation system (POLARx; Boston Scientific) for pulmonary vein isolation (PVI) compared with the standard cryoballoon (SCB) system (Arctic Front, Medtronic). METHODS AND RESULTS: Consecutive patients with atrial fibrillation (AF) undergoing PVI using the NCB and the SCB at two centres were included. We report 1-year efficacy after 12 months, short-term safety and hospitalizations within the blanking period, and predictors for AF recurrence. In case of repeat procedures, pulmonary vein (PV) reconnection patterns were characterized. Eighty patients (age 66 ± 10 years, ejection fraction 57 ± 10%, left atrial volume index 39 ± 13 mL/m2, paroxysmal AF in 64%) were studied. After a single procedure and a follow-up of 12 months, 68% in the NCB group and 70% in the SCB group showed no recurrence of AF/atrial tachycardias (P = 0.422). One patient in the NCB group suffered a periprocedural stroke with full recovery. There were no differences regarding hospitalizations during follow-up between the groups. PV reconnection observed during 12 repeat procedures (4 NCB, 8 SCB) pattern was comparable between the groups with more reconnections in the right-sided compared with the left-sided PVs. CONCLUSION: In this multicentre study comparing two currently available cryoballoon ablation systems for PVI, no differences were observed in the efficacy and safety during a follow-up of 12 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
8.
Artif Organs ; 46(6): 1132-1141, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34978729

RESUMO

BACKGROUND: Implanted cardioverter defibrillators (ICDs) and left ventricular assist devices (LVADs) are established interventions that prolong life in advanced heart failure, but their combination has not been demonstrated as beneficial. Electromagnetic interference (EMI) produced by a LVAD can preclude ICD interrogation with external programmers. We undertook a systematic evaluation of the LVAD-ICD interaction "in-vitro" to clarify the extent of this interaction. METHODS: Using explanted ICDs and VADs in a mock physiological rig, we assessed interrogation and reprogramming of ICD devices in the presence of a running LVAD. When connectivity between the ICD programmer and the ICD failed, we attempted three different techniques to re-establish connectivity: (1) Electromagnetic shielding of the ICD with a pseudo-faraday cage; (2) altering the LVAD speed; and (3) increasing the distance between the VAD and the ICD. RESULTS: We tested a total of 24 ICDs from different manufacturers in the presence of the Heartware (HW) and HeartMate 3 (HM3) LVADs. With HW, we only observed interaction with Biotronik ICD devices at very close range (0-6 cm). With HM3, only Medtronic ICD devices showed no interaction. Interactions could be mitigated by increasing the VAD-ICD distance. CONCLUSIONS: LVADs, notably the HM3, produce EMI that interferes with the communication between an ICD and its respective programmer. This may need to be considered when choosing the type of VAD to implant in patients with a previously implanted left-sided ICD. The only safe way to regain connectivity is to increase the distance between the VAD and the ICD, with patients raising their arm above their head.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Dexametasona , Fenômenos Eletromagnéticos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos
9.
J Cardiovasc Electrophysiol ; 32(6): 1610-1619, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33928711

RESUMO

INTRODUCTION: Chemical ablation by retrograde infusion of ethanol into the vein of Marshall (VOM-EI) can facilitate the achievement of mitral isthmus block. This study sought to describe the efficacy and safety of this technique. METHODS AND RESULTS: Twenty-two consecutive patients (14 males, median age 71 years) with attempted VOM-EI for mitral isthmus ablation were included in the study. VOM-EI was successfully performed with a median of 4 ml of 96% ethanol in 19 patients (86%) and the mitral isthmus was successfully blocked in all (100%). Touch up endocardial and/or epicardial ablation after VOM-EI was necessary for 12 patients (63%). Perimitral flutter was present in 12 patients (63%) during VOM-EI and terminated or slowed by VOM-EI in 4 and 3 patients, respectively. The low-voltage area of the mitral isthmus region increased from 3.1 cm2 (interquartile range [IQR] 0-7.9) before to 13.2 cm2 (IQR: 8.2-15.0) after VOM-EI and correlated significantly with the volume of ethanol injected (p = .03). Median high-sensitive cardiac troponin-T increased significantly from 330 ng/L (IQR: 221-516) the evening of the procedure to 598 ng/L (IQR: 382-769; p = .02) the following morning. A small pericardial effusion occurred in three patients (16%), mild pericarditis in one (5%), and uneventful VOM dissection in two (11%). After a median follow-up of 3.5 months (IQR: 3.0-11.0), 10 of 18 patients (56%) with VOM-EI and available follow-up had arrhythmia recurrence. Repeat ablation was performed in five patients (50%) and peri-mitral flutter diagnosed in three (60%). CONCLUSION: VOM-EI is feasible, safe, and effective to achieve acute mitral isthmus block.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Etanol/efeitos adversos , Humanos , Masculino , Recidiva , Veias
10.
Europace ; 23(4): 603-609, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33207371

RESUMO

AIMS: Catheter ablation of frequent idiopathic pre-mature ventricular contractions (PVC) is increasingly performed. While potential benefits of contact force (CF)-sensing technology for atrial fibrillation ablation have been assessed in several studies, the impact of CF-sensing on ventricular arrhythmia ablation remains unknown. This study aimed to compare outcomes of idiopathic outflow tract PVC ablation when using standard ablation catheters as opposed to CF-sensing catheters. METHODS AND RESULTS: In a retrospective multi-centre study, unselected patients undergoing catheter ablation of idiopathic outflow tract PVCs between 2013 and 2016 were enrolled. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24 h Holter ECG during follow-up. Overall, 218 patients were enrolled (median age 52 years, 51% males). Baseline and procedural data were similar in the standard ablation (24%) and the CF-sensing group (76%). Overall, the median PVC burden decreased from 21% (IQR 10-30%) before ablation to 0.2% (IQR 0-3.0%) after a median follow-up of 2.3 months (IQR 1.4-3.9 months). The rates of both acute (91% vs. 91%, P = 0.94) and sustained success (79% vs. 74%, P = 0.44) were similar in the standard ablation and the CF-sensing groups. No differences were observed in subgroups according to arrhythmia origin from the RVOT (65%) or LVOT (35%). Complications were rare (1.8%) and evenly distributed between the two groups. CONCLUSION: The use of CF-sensing technology is not associated with increased success rate nor decreased complication rate in idiopathic outflow tract PVC ablation.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Ablação por Cateter/efeitos adversos , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tecnologia , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
11.
Pacing Clin Electrophysiol ; 44(4): 703-710, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33675240

RESUMO

BACKGROUND: Radiofrequency catheter ablation of idiopathic premature ventricular complexes (PVCs) is an effective method for eliminating symptoms and preventing/reversing arrhythmia-induced cardiomyopathy. One reason for procedural failure is low PVC frequency during the procedure. We aimed to investigate the relation between pre-procedural PVC burden and outcome of idiopathic PVC catheter ablation. METHODS: Patients who underwent idiopathic PVC ablation between 2013 and 2019 at two tertiary referral centers were retrospectively included. All procedures were performed using irrigated-tip ablation catheters and a 3D electro-anatomical mapping system. Sustained ablation success was defined as a ≥80% reduction of pre-procedural PVC burden determined by 24h-Holter at follow-up. RESULTS: Overall, 254 patients (median age 54 years [IQR 42-64]; 47% male) were enrolled. The median pre-ablation PVC-burden was 22% (IQR 11-31%), which was reduced to a post-ablation PVC burden of 0.3% (IQR 0-4%) after a median of 90 days. Sustained ablation success was achieved in 182 patients (72%). Pre-procedural PVC burden did not differ between patients with sustained ablation success and recurrence during follow-up (median 21% vs. 22%, p = .76). When assessed in pre-ablation PVC-burden groups of ≤5%, 6-15%, 16-30%, and ≥31%, sustained ablation success was achieved in 67%, 75%, 71%, and 72%, respectively, with no significant difference (p = .89). Sustained ablation outcome for PVC-burden ≤5% versus >5% showed no difference either (67% vs. 72%, p = .52). CONCLUSIONS: Pre-procedural Holter-determined PVC burden does not predict the outcome of idiopathic PVC ablation. Thus, catheter ablation may be a reasonable first choice also for patients with symptomatic yet rare PVCs.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Eletrocardiografia Ambulatorial , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Suíça
12.
Pacing Clin Electrophysiol ; 43(2): 234-239, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31849077

RESUMO

INTRODUCTION: Diaphragmatic myopotential oversensing (dMPO) by implantable cardioverter defibrillators (ICDs) is thought to be a rare condition that can be misdiagnosed as lead failure and lead to unnecessary lead replacement. We observed several cases of dMPO in patients with Sorin/LivaNova ICDs (MicroPort Sci.). We sought to systematically assess the incidence of dMPO in patients with Sorin/LivaNova ICDs. METHODS AND RESULTS: A predefined number of 100 consecutive patients with Sorin/LivaNova ICDs were prospectively included in the device clinic of our center. Stored arrhythmia episodes were checked for spontaneous dMPO. In addition, we performed provocation maneuvers by Valsalva. At least one episode of spontaneous or provoked dMPO was seen in 12 (12%) of the 100 patients included in the study (86% males, median age: 66 years). Nine of 89 patients (10%) with true bipolar and 3 of 11 patients (27%) with integrated bipolar sensing configuration were affected. Spontaneous dMPO was observed in 7 of 58 patients (12%) with sensitivity programmed to 0.4 mV and in 2 of 42 patients (5%) with sensitivity programmed to 0.6 mV (not significant). In three patients, dMPO could be provoked with no spontaneous episodes recorded. In two nonpacemaker-dependent patients with a CRT-D, ventricular pacing was temporarily inhibited. No antitachycardia therapy was triggered by dMPO in any patient. CONCLUSIONS: DMPO is frequent in patients with Sorin/LivaNova ICDs, especially with sensitivity programmed to 0.4 mV. It also frequently occurs with true bipolar sensing configuration. DMPO should not be misinterpreted as lead failure to avoid unnecessary lead replacement.


Assuntos
Desfibriladores Implantáveis , Diafragma/inervação , Diafragma/fisiopatologia , Potencial Evocado Motor/fisiologia , Idoso , Erros de Diagnóstico , Falha de Equipamento , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Manobra de Valsalva/fisiologia
13.
J Cardiovasc Electrophysiol ; 29(1): 79-89, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28940781

RESUMO

BACKGROUND: Right ventricular (RV)-scar related ventricular tachycardia (VT) is often due to arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) or cardiac sarcoidosis (CS), but some patients whose clinical course has not been described do not fulfill diagnostic criteria for these diseases. We sought to characterize the electrophysiologic substrate and catheter ablation outcomes of such patients, termed RV cardiomyopathy of unknown source (RCUS). METHODS AND RESULTS: Data of 100 consecutive patients who presented with RV cardiomyopathy and/or RV-related VT for ablation were reviewed (51 ARVC/D, 22 CS; 27 RCUS). Compared to ARVC/D, RCUS patients were older (P = 0.001), less commonly had RV dilatation (P = 0.001) or dysfunction (P = 0.01) and fragmented QRS, parietal block, and T-wave inversion. Compared to CS, R-CUS patients had less severe LV dysfunction. Extent and distribution of endocardial/epicardial scar and inducible VTs in RCUS patients were comparable with ARVC/D and CS patients. At a median follow-up of 23 months, RCUS patients had more favorable VT-free survival (RCUS 71%, ARVC/D 60%, CS 41%, P = 0.03) and survival free of death or cardiac transplant (RCUS 92%, ARVC/D 92%, CS 62%, P = 0.01). No RCUS patients developed new criteria for ARVC/D or CS in follow-up. CONCLUSIONS: Up to one-third of patients with RV scar-related VT are not classifiable as ARVC/D or CS. These patients had a somewhat better prognosis than ARVC/D or sarcoid and did not develop evidence of these diseases during the initial 2 years of follow-up. The extent to which this population comprises mild ARVC/D, CS, or other diseases is not clear.


Assuntos
Cardiomiopatias/complicações , Ablação por Cateter , Frequência Cardíaca , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Função Ventricular Direita , Potenciais de Ação , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Ablação por Cateter/efeitos adversos , Diagnóstico Diferencial , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sarcoidose/diagnóstico , Sarcoidose/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
14.
Europace ; 20(4): 596-603, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339750

RESUMO

Aims: Atrial tachycardia (AT) related to atrial fibrillation (AF) ablation frequently poses a diagnostic challenge. Downstream overdrive pacing (DOP) can be used to rapidly detect reentry and assess proximity of a pacing site to an AT circuit or focus. We hypothesized that systematic DOP using multielectrode catheters would facilitate AT mapping. Methods and results: DOP identified constant fusion when the post-pacing interval (PPI)-tachycardia cycle length (TCL) <40 ms and stimulus to adjacent upstream atrial electrogram interval >75% of TCL. Mapping was performed as follows: (i) CS DOP, (ii) DOP at left atrial (LA) roof, (iii) DOP at selected LA sites based on prior DOP attempts, and (iv) mapping and ablation at regions of fractionated electrograms in region of AT. Activation mapping was performed at operator discretion. AT diagnosis was confirmed by successful ablation or additional mapping when ablation was unsuccessful. Fifty consecutive patients with sustained AT underwent mapping of 68 ATs, of whom 42 (62%) were macroreentrant, 19 were locally reentrant (28%), and 7 (10%) were focal. AT was correctly identified with a median of three DOP attempts. All macroreentrant ATs were identified with ≤6 DOP attempts. One AT (1.6%) was terminated by DOP, and three ATs (4.8%) required activation mapping. Intracardiac concealed fusion was seen in 26 ATs (38%), each of which was successfully ablated. Conclusion: Reentry could be demonstrated in a substantial majority of AF ablation-related AT. A stepwise diagnostic approach using DOP and recognition of intracardiac concealed fusion can be used to rapidly identify and ablate reentrant AT.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Estimulação Cardíaca Artificial , Ablação por Cateter/efeitos adversos , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/diagnóstico , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Valor Preditivo dos Testes , Fatores de Risco , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 28(2): 201-207, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27860063

RESUMO

INTRODUCTION: Women are underrepresented in clinical studies on catheter ablation (CA) for ventricular tachycardia (VT). The role of gender as a predictor for VT recurrence after CA is unclear and complication rates have not been compared in a large cohort. METHODS AND RESULTS: We analyzed data of consecutive patients undergoing CA for sustained monomorphic VT at our center between 2005 and 2015. A total of 948 patients underwent 1314 ablation procedures: 114 patients without structural heart disease (SHD) (48% female), 486 with coronary artery disease (CAD) (9% female), 301 with nonischemic cardiomyopathy (NICM) (22% female), and 46 with arrhythmogenic right ventricular cardiomyopathy (ARVC) (17% female). Women with CAD and NICM were younger than men at first ablation (63 years vs. 68 years, P = 0.05; resp. 53 years vs. 59 years, P = 0.026) with no other significant differences in baseline characteristics. Age, LVEF, NYHA-class, and VT-recurrence but not gender were independently associated with increased mortality in CAD and NICM. Mortality rates in patients with no SHD and ARVC are low in men (0%, 2.6%) and women (1.8%, 0%). CONCLUSIONS: Although heart disease tends to present later in women, our data do not suggest that women are referred later than men. Women with CAD or NICM and VT present for ablation at younger age with disease severity comparable to men. VT ablation in women can be accomplished with success- and complication rates comparable to male patients in both those with and without SHD.


Assuntos
Ablação por Cateter , Taquicardia Ventricular/cirurgia , Adulto , Fatores Etários , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Eletrocardiografia , Feminino , Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
16.
J Cardiovasc Electrophysiol ; 27(12): 1437-1447, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27574120

RESUMO

INTRODUCTION: Substrate-based ablation for scar-related ventricular tachycardia (VT) has gained prominence: however, there is limited data comparing it to ablation guided predominantly by activation and entrainment mapping of inducible and hemodynamically tolerated VTs. We compared the acute procedural efficacy and outcomes of predominantly substrate-based ablation versus ablation guided predominantly by activation and entrainment mapping. METHODS AND RESULTS: Database searches through April 2016 identified 6 eligible studies (enrolling 403 patients, with 1 randomized study) comparing the 2 strategies. The relative risk of VT recurrence at follow-up was assessed as the primary outcome using a random-effects meta-analysis. Secondary endpoints of acute success (based on noninducibility of VT), procedural complications, and mortality were assessed using weighted mean difference with the random effects model. At a median follow-up of 18 months, the relative risk (RR) of VT recurrence was not significantly different with substrate-based versus activation/entrainment guided VT ablation (0.72, 95% confidence interval [CI] 0.44-1.18), P = 0.2). Acute success (RR 1.02, 95% CI 0.95-1.1, P = 0.6), procedural complications (RR 0.8, 95% CI 0.35-1.82, P = 0.5) cardiovascular mortality and total mortality did not differ significantly (RR 0.83, 95% CI 0.38-1.79, P = 0.6 and RR 0.76, 95% CI 0.36-1.59, P = 0.5, respectively). CONCLUSIONS: This meta-analysis demonstrates similar acute procedural efficacy, and complications, VT recurrence and mortality rates when comparing a predominantly substrate-based ablation strategy to a strategy guided predominantly by activation and entrainment mapping of inducible and hemodynamically tolerated VTs.


Assuntos
Ablação por Cateter/métodos , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Potenciais de Ação , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Distribuição de Qui-Quadrado , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Recidiva , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
17.
Curr Opin Cardiol ; 31(1): 29-36, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26569083

RESUMO

PURPOSE OF REVIEW: This article summarizes current understanding of the arrhythmia substrate and effect of catheter ablation for infarct-related ventricular tachycardia, focusing on recent findings. RECENT FINDINGS: Clinical studies support the use of catheter ablation earlier in the course of ischemic disease with moderate success in reducing arrhythmia recurrence and shocks from implantable defibrillators, although mortality remains unchanged. Ablation can be lifesaving for patients presenting with electrical storm. Advanced mapping systems with image integration facilitate identification of potential substrate, and several different approaches to manage hemodynamically unstable ventricular tachycardia have emerged. Novel ablation techniques that allow deeper lesion formation are in development. SUMMARY: Catheter ablation is an important therapeutic option for preventing or reducing episodes of ventricular tachycardia in patients with ischemic cardiomyopathy. Present technologies allow successful ablation in the majority of patients, even when the arrhythmia is hemodynamically unstable. Failure of the procedure is often because of anatomic challenges that will hopefully be addressed with technological progress.


Assuntos
Ablação por Cateter/métodos , Ablação por Cateter/normas , Isquemia Miocárdica/etiologia , Guias de Prática Clínica como Assunto , Taquicardia Ventricular/cirurgia , Eletrocardiografia , Humanos , Isquemia Miocárdica/cirurgia , Taquicardia Ventricular/complicações
18.
Europace ; 17(10): 1571-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25840288

RESUMO

AIMS: In patients presenting with spontaneous sustained ventricular tachycardia (VT) from the outflow-tract region without overt structural heart disease ablation may target premature ventricular contractions (PVCs) when VT is not inducible. We aimed to determine whether inducibility of VT affects ablation outcome. METHODS AND RESULTS: Data from 54 patients (31 men; age, 52 ± 13 years) without overt structural heart disease who underwent catheter ablation for symptomatic sustained VT originating from the right- or left-ventricular outflow region, including the great vessels. A single morphology of sustained VT was inducible in 18 (33%, SM group) patients, and 11 (20%) had multiple VT morphologies (MM group). VT was not inducible in 25 (46%) patients (VTni group). After ablation, VT was inducible in none of the SM group and in two (17%) patients in the MM group. In the VTni group, ablation targeted PVCs and 12 (48%) patients had some remaining PVCs after ablation. During follow-up (21 ± 19 months), VT recurred in 46% of VTni group, 40% of MM inducible group, and 6% of the SM inducible group (P = 0.004). Analysis of PVC morphology in the VTi group further supported the limitations of targeting PVCs in this population. CONCLUSION: Absence of inducible VT and multiple VT morphologies are not uncommon in patients with documented sustained outflow-tract VT without overt structural heart disease. Inducible VT is associated with better outcomes, suggesting that attempts to induce VT to guide ablation are important in this population.


Assuntos
Ablação por Cateter/normas , Eletrocardiografia/classificação , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/cirurgia , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Recidiva , Resultado do Tratamento
19.
BMC Cardiovasc Disord ; 15: 4, 2015 Jan 19.
Artigo em Inglês | MEDLINE | ID: mdl-25599583

RESUMO

BACKGROUND: Arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) is considered a progressive cardiomyopathy. However, data on the clinical features of disease progression are limited. The aim of this study was to assess 12-lead surface electrocardiographic (ECG) changes during long-term follow-up, and to compare these findings with echocardiographic data in our large cohort of patients with ARVC/D. METHODS: Baseline and follow-up ECGs of 111 patients from three tertiary care centers in Switzerland were systematically analyzed with digital calipers by two blinded observers, and correlated with findings from transthoracic echocardiography. RESULTS: The median follow-up was 4 years (IQR 1.9-9.2 years). ECG progression was significant for epsilon waves (baseline 14% vs. follow-up 31%, p = 0.01) and QRS duration (111 ms vs. 114 ms, p = 0.04). Six patients with repolarization abnormalities according to the 2010 Task Force Criteria at baseline did not display these criteria at follow-up, whereas in all patients with epsilon waves at baseline these depolarization abnormalities also remained at follow-up. T wave inversions in inferior leads were common (36% of patients at baseline), and were significantly associated with major repolarization abnormalities (p = 0.02), extensive echocardiographic right ventricular involvement (p = 0.04), T wave inversions in lateral precordial leads (p = 0.05), and definite ARVC/D (p = 0.05). CONCLUSIONS: Our data supports the concept that ARVC/D is generally progressive, which can be detected by 12-lead surface ECG. Repolarization abnormalities may disappear during the course of the disease. Furthermore, the presence of T wave inversions in inferior leads is common in ARVC/D.


Assuntos
Displasia Arritmogênica Ventricular Direita/fisiopatologia , Eletrocardiografia , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Progressão da Doença , Ecocardiografia , Ecocardiografia Doppler em Cores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA