Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Bases de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Blood ; 137(12): 1591-1602, 2021 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-33275650

RESUMO

Digital protein assays have great potential to advance immunodiagnostics because of their single-molecule sensitivity, high precision, and robust measurements. However, translating digital protein assays to acute clinical care has been challenging because it requires deployment of these assays with a rapid turnaround. Herein, we present a technology platform for ultrafast digital protein biomarker detection by using single-molecule counting of immune-complex formation events at an early, pre-equilibrium state. This method, which we term "pre-equilibrium digital enzyme-linked immunosorbent assay" (PEdELISA), can quantify a multiplexed panel of protein biomarkers in 10 µL of serum within an unprecedented assay incubation time of 15 to 300 seconds over a 104 dynamic range. PEdELISA allowed us to perform rapid monitoring of protein biomarkers in patients manifesting post-chimeric antigen receptor T-cell therapy cytokine release syndrome, with ∼30-minute sample-to-answer time and a sub-picograms per mL limit of detection. The rapid, sensitive, and low-input volume biomarker quantification enabled by PEdELISA is broadly applicable to timely monitoring of acute disease, potentially enabling more personalized treatment.


Assuntos
Citocinas/sangue , Doenças do Sistema Imunitário/sangue , Testes Imediatos , Biomarcadores/sangue , Proteínas Sanguíneas/análise , Ensaio de Imunoadsorção Enzimática , Desenho de Equipamento , Humanos
2.
JMIR Res Protoc ; 2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34115607

RESUMO

BACKGROUND: The COVID-19 pandemic has impacted lives significantly and greatly affected an already vulnerable population, college students, in relation to mental health and public safety. Social distancing and isolation have brought about challenges to student's mental health. Mobile health apps and wearable sensors may help to monitor students at risk for COVID-19 and support their mental well-being. OBJECTIVE: Through the use of a wearable sensor and smartphone-based survey completion, this study aimed to monitor students at risk for COVID-19. METHODS: We conducted a prospective study of students, undergraduate and graduate, at a public university in the Midwest. Students were instructed to download the Fitbit, Social Rhythms, and Roadmap 2.0 apps onto their personal mobile devices (Android or iOS). Subjects consented to provide up to 10 saliva samples during the study period. Surveys were administered through the Roadmap 2.0 app at five timepoints - at baseline, 1-month later, 2-months later, 3-months later, and at study completion. The surveys gathered information regarding demographics, COVID-19 diagnoses and symptoms, and mental health resilience, with the aim of documenting the impact of COVID-19 on the college student population. RESULTS: This study enrolled 2,158 college students between September 2020 and January 2021. Subjects are currently being followed on-study for one academic year. Data collection and analysis are ongoing. CONCLUSIONS: This study examined student health and well-being during the COVID-19 pandemic. It also assessed the feasibility of wearable sensor use and survey completion in a college student population, which may inform the role of our mobile health tools on student health and well-being. Finally, using wearable sensor data, biospecimen collection, and self-reported COVID-19 diagnosis, our results may provide key data towards the development of a model for the early prediction and detection of COVID-19. CLINICALTRIAL: ClinicalTrials.gov NCT04766788.

3.
JMIR Res Protoc ; 10(5): e29562, 2021 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-33945497

RESUMO

BACKGROUND: Health care workers (HCWs) have been working on the front lines of the COVID-19 pandemic with high risks of viral exposure, infection, and transmission. Standard COVID-19 testing is insufficient to protect HCWs from these risks and prevent the spread of disease. Continuous monitoring of physiological data with wearable sensors, self-monitoring of symptoms, and asymptomatic COVID-19 testing may aid in the early detection of COVID-19 in HCWs and may help reduce further transmission among HCWs, patients, and families. OBJECTIVE: By using wearable sensors, smartphone-based symptom logging, and biospecimens, this project aims to assist HCWs in self-monitoring COVID-19. METHODS: We conducted a prospective, longitudinal study of HCWs at a single institution. The study duration was 1 year, wherein participants were instructed on the continuous use of two wearable sensors (Fitbit Charge 3 smartwatch and TempTraq temperature patches) for up to 30 days. Participants consented to provide biospecimens (ie, nasal swabs, saliva swabs, and blood) for up to 1 year from study entry. Using a smartphone app called Roadmap 2.0, participants entered a daily mood score, submitted daily COVID-19 symptoms, and completed demographic and health-related quality of life surveys at study entry and 30 days later. Semistructured qualitative interviews were also conducted at the end of the 30-day period, following completion of daily mood and symptoms reporting as well as continuous wearable sensor use. RESULTS: A total of 226 HCWs were enrolled between April 28 and December 7, 2020. The last participant completed the 30-day study procedures on January 16, 2021. Data collection will continue through January 2023, and data analyses are ongoing. CONCLUSIONS: Using wearable sensors, smartphone-based symptom logging and survey completion, and biospecimen collections, this study will potentially provide data on the prevalence of COVID-19 infection among HCWs at a single institution. The study will also assess the feasibility of leveraging wearable sensors and self-monitoring of symptoms in an HCW population. TRIAL REGISTRATION: ClinicalTrials.gov NCT04756869; https://clinicaltrials.gov/ct2/show/NCT04756869. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/29562.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA