Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Int J Mol Sci ; 20(13)2019 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-31261853

RESUMO

Conjugation of latent growth factors to superparamagnetic iron oxide nanoparticles (SPIONs) is potentially useful for magnetically triggered release of bioactive macromolecules. Thus, the goal of this work was to trigger the release of active Transforming Growth-Factor Beta (TGF-ß) via magnetic hyperthermia by binding SPIONs to the latent form of TGF-ß, since heat has been shown to induce release of TGF-ß from the latent complex. Commercially available SPIONS with high specific absorption rates (SAR) were hydrolyzed in 70% ethanol to create surface carboxylic acid conjugation sites for carbodiimide chemistry. Fourier-Transform Infra-Red (FTIR) analysis verified the conversion of maleic anhydride to maleic acid. 1-Ethyl-2-(3-dimethyulaminopropyl) carbodiimide (EDC) and N-hydroxysulfosuccinimide (Sulfo-NHS) were used to bind to the open conjugation sites of the SPION in order to graft latent TGF-ß onto the particles. The resulting conjugated particles were imaged with transmission electron microscopy (TEM), and the complexed particles were characterized by dynamic light scattering (DLS) and superconducting quantum interference device (SQUID) magnetometry. Enzyme-linked immunosorbent assay (ELISA) was used to assess the thermally triggered release of active TGF-ß from the latent complex, demonstrating that conjugation did not interfere with release. Results showed that latent TGF-ß was successfully conjugated to the iron oxide nanoparticles, and magnetically triggered release of active TGF-ß was achieved.


Assuntos
Carbodi-Imidas/química , Nanopartículas Metálicas/química , Nanoconjugados/química , Fator de Crescimento Transformador beta/química , Liberação Controlada de Fármacos , Compostos Férricos/química , Campos Magnéticos , Succinimidas/química , Fator de Crescimento Transformador beta/administração & dosagem
2.
Vet Surg ; 47(5): 722-728, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29697147

RESUMO

OBJECTIVE: To determine the ability of a polyacrylic acid-silicone radiolucent self-retaining gradual occlusion device (PAS-OD) to attenuate congenital extrahepatic portosystemic shunts (EHPSS) in dogs. STUDY DESIGN: Prospective clinical trial. ANIMALS: Six client-owned dogs with single, congenital EHPSS. METHODS: Serum bile acids (SBA), abdominal ultrasonography, and computed tomographic angiography (CTA) were performed preoperatively and at 4 and 8 weeks postoperatively. Each dog was treated for EHPSS by placement of a PAS-OD. RESULTS: PAS-OD were placed without complication an average of 4.3 seconds (range, 3-7) after isolation of the shunt. Median surgical time was 38.5 minutes (range, 28-84) including concurrent procedures. All dogs recovered from surgery without complications. SBA were normal in 5 of 6 dogs at 4 and 8 weeks after surgery. The shunt was completely attenuated in 2 of 6 dogs at 4 weeks and in 4 of 6 dogs at 8 weeks, without evidence of acquired shunt formation in any dog. The size and velocity of the portal vasculature were improved in 5 of 6 dogs according to 8-week postoperative CTA and ultrasonography results, respectively. The remaining dog had a persistently decreased portal vasculature size but a normal velocity according to 8-week postoperative CTA and ultrasound results, respectively. CONCLUSION: The PAS-OD led to complete attenuation in 4 of 6 dogs and partial attenuation with mild residual flow of 2 EHPSS over an 8-week period in dogs. CLINICAL SIGNIFICANCE: The PAS-OD is a new option for gradual occlusion of congenital EHPSS over 8 weeks.


Assuntos
Doenças do Cão/cirurgia , Sistema Porta/anormalidades , Silicones , Procedimentos Cirúrgicos Vasculares/instrumentação , Animais , Materiais Biocompatíveis , Doenças do Cão/congênito , Doenças do Cão/diagnóstico por imagem , Cães , Feminino , Masculino , Sistema Porta/cirurgia , Complicações Pós-Operatórias/veterinária , Estudos Prospectivos , Resultado do Tratamento
3.
Int J Mol Sci ; 14(9): 17501-10, 2013 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-24065092

RESUMO

Feraheme, is a recently FDA-cleared superparamagnetic iron oxide nanoparticle (SPION)-based MRI contrast agent that is also employed in the treatment of iron deficiency anemia. Feraheme nanoparticles have a hydrodynamic diameter of 30 nm and consist of iron oxide crystallites complexed with a low molecular weight, semi-synthetic carbohydrate. These features are attractive for other potential biomedical applications such as magnetic fluid hyperthermia (MFH), since the carboxylated polymer coating affords functionalization of the particle surface and the size allows for accumulation in highly vascularized tumors via the enhanced permeability and retention effect. This work presents morphological and magnetic characterization of Feraheme by transmission electron microscopy (TEM), Energy dispersive X-ray spectroscopy (EDX), and superconducting quantum interference device (SQUID) magnetometry. Additionally, the results of an initial evaluation of the suitability of Feraheme for MFH applications are described, and the data indicate the particles possess promising properties for this application.


Assuntos
Óxido Ferroso-Férrico/química , Nanopartículas de Magnetita/química , Meios de Contraste/química , Humanos , Hipertermia Induzida , Magnetometria , Microscopia Eletrônica de Transmissão , Neoplasias/terapia , Tamanho da Partícula , Espectrometria por Raios X
4.
Artigo em Inglês | MEDLINE | ID: mdl-36793495

RESUMO

Mosquitoes can impact military operational readiness by transmission of disease-causing pathogens or through secondary effects, e.g., annoyance and bites. The focus of this research was to determine if an array of novel controlled release passive devices (CRPD) utilizing the spatial repellent, transfluthrin (TF), as the active ingredient could prevent entry of mosquitoes into military tents for up to 4 weeks. The TF-charged CRPDs were spaced along six strands of monofilament and hung across the tent entrance. Efficacy was evaluated with caged Aedes aegypti to indicate knockdown/mortality effects, and four species of free-flying mosquitoes, Ae. aegypti, Aedes taeniorhynchus, Anopheles quadrimaculatus and Culex quinquefasciatus, to indicate repellent effects. Bioassay cages containing Ae. aegypti were hung vertically at 0.5, 1.0 and 1.5 â€‹m above ground level at designated locations inside of the tents. Knockdown/mortality counts were made every 15 min for the first hour, then at 2, 4 and 24 h post-exposure. Free fliers were recaptured in BG traps operated from 4 to 24 h post-exposure. Knockdown/mortality was gradual until 4 h post-exposure. This increased to near 100% by 24 h in the treated tent but was < 2% in the control tent. There was a significant reduction in the recapture rates of all free-flying species in the treated tent compared with the control tent. Results indicate that TF-charged CRPDs can significantly reduce the numbers of mosquitoes entering military tents and that the four species were affected similarly by the TF. The needs for additional research are discussed.

5.
Circulation ; 124(20): 2243-52, 2011 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-22007074

RESUMO

BACKGROUND: Up to 5% of the population may have a brain aneurysm. If the brain aneurysm ruptures, there is >50% mortality, and more than one third of survivors are dependent. Brain aneurysms detected before rupture can be treated to prevent rupture, or ruptured aneurysms can be treated to prevent rerupture. Endovascular coiling of brain aneurysms is the treatment of choice for some aneurysms; however, up to one quarter of aneurysms may recur. The coiled aneurysms that do not recur are characterized by inflammatory intra-aneurysmal tissue healing; therefore, we studied the biology of this process, specifically the role of monocyte chemotactic protein-1 (MCP-1), a cytokine known for tissue healing. METHODS AND RESULTS: We created coils with a 50:50 poly-dl-lactic glycolic acid (PLGA) coating that released MCP-1 at 3 different doses (100 µg/mL, 1 mg/mL, and 10 mg/mL) and performed a dose-response study for effect on intra-aneurysmal tissue healing in a murine carotid aneurysm model. We then demonstrated that MCP-1 (100 µg/mL)-releasing coils promote significantly greater aneurysm tissue in-growth than bare platinum or PLGA-only coils. We show that MCP-1 recruits the migration of fibroblasts, macrophages, smooth muscle cells, and endothelial cells in vitro in cell migration assays and in vivo in murine carotid aneurysms. Using gfp(+) bone marrow-transplant chimeric mice, we demonstrate that the MCP-1-recruited fibroblasts and macrophages are derived from the bone marrow. We demonstrate that this MCP-1-mediated vascular inflammatory repair occurs via a macrophage inflammatory protein (MIP)-1α- and MIP-2-dependent pathway. MCP-1 released from coiled murine aneurysms causes significant upregulation of MIP-1α and MIP-2 expression by cytokine array assay. Blocking MIP-1α and MIP-2 with antagonist antibody causes a significant decrease in MCP-1-mediated intra-aneurysmal tissue healing. CONCLUSION: Our findings suggest that MCP-1 has a critical role in promoting inflammatory intra-aneurysmal tissue healing in an MIP-1α- and MIP-2-dependent pathway.


Assuntos
Dissecação da Artéria Carótida Interna/metabolismo , Dissecação da Artéria Carótida Interna/patologia , Quimiocina CCL2/administração & dosagem , Quimiocina CCL3/fisiologia , Quimiocina CXCL2/fisiologia , Modelos Animais de Doenças , Mediadores da Inflamação/fisiologia , Transdução de Sinais/fisiologia , Animais , Dissecação da Artéria Carótida Interna/tratamento farmacológico , Quimiocina CCL2/metabolismo , Relação Dose-Resposta a Droga , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Cicatrização/fisiologia
6.
J Mater Sci Mater Med ; 23(8): 2037-46, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22710955

RESUMO

Infusate backflow or leak-back along the cannula track can occur during intraparenchymal infusions resulting in non-specific targeting of therapeutic agents. The occurrence of backflow depends on several variables including cannula radius, infusate flow rate, and tip location. In this study, polymer coatings that swell in situ were developed and tested with in vitro hydrogel experiments for backflow reduction. Coatings were applied to the external cannula surface in a dual layer arrangement with a poly(vinyl alcohol) outer layer atop an inner poly(ethylene oxide) and alginate layer. Once these coated cannulas were inserted and allotted an 8-10 min waiting period for hydration, backflow during infusions of 4.0 µl of a macromolecular tracer (Evans Blue labeled albumin) was reduced significantly under flow rates of 0.3-0.6 µl/min, allowing for more effective distribution within targeted regions. Polymer coating thicknesses before and after hydrations were 0.035 and 0.370 mm, respectively. Also, backflow data was fit to a model to estimate the effective local compressive stress caused by the hydrated polymers. After withdrawal of the cannula from the insertion site, the hydrated polymer coatings remained within the cavity left in the hydrogel tissue phantom and formed a seal at the infusion site that prevented further backflow during needle withdrawal. Ex vivo infusions in excised porcine brain tissues also showed significant backflow reduction while also demonstrating the ability to leave a polymer seal in the tissue cavity after cannula removal. Thus, application of these polymers as needle or cannula coatings offers a potentially simple method to improve targeting for local drug delivery.


Assuntos
Química Encefálica , Catéteres , Materiais Revestidos Biocompatíveis/química , Polímeros/química , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Infusões Parenterais/instrumentação , Teste de Materiais , Suínos
7.
J Am Soc Nephrol ; 20(11): 2338-47, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19729441

RESUMO

The scarcity of transplant allografts for diseased organs has prompted efforts at tissue regeneration using seeded scaffolds, an approach hampered by the enormity of cell types and complex architectures. Our goal was to decellularize intact organs in a manner that retained the matrix signal for differentiating pluripotent cells. We decellularized intact rat kidneys in a manner that preserved the intricate architecture and seeded them with pluripotent murine embryonic stem cells antegrade through the artery or retrograde through the ureter. Primitive precursor cells populated and proliferated within the glomerular, vascular, and tubular structures. Cells lost their embryonic appearance and expressed immunohistochemical markers for differentiation. Cells not in contact with the basement membrane matrix became apoptotic, thereby forming lumens. These observations suggest that the extracellular matrix can direct regeneration of the kidney, and studies using seeded scaffolds may help define differentiation pathways.


Assuntos
Diferenciação Celular , Proliferação de Células , Células-Tronco Embrionárias/citologia , Rim , Alicerces Teciduais , Animais , Células Cultivadas , Masculino , Ratos , Ratos Sprague-Dawley
8.
Materials (Basel) ; 13(16)2020 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-32824815

RESUMO

The effect of pH changes on the chemical durability of dental glass-ceramic materials was evaluated using weight loss and ion release levels. The hypothesis that increased pH changes will exhibit greater corrosion was investigated. The ion concentration was analyzed using inductively coupled plasma atomic emission spectrometer (ICP). The surface compositions were investigated using X-ray photoelectron spectroscopy (XPS). The surface morphologies were examined using scanning electron microscopy (SEM). Dental glass-ceramics were tested in constant immersion, 3-day cycling, and 1-day cycling with pH 10, pH 2, and pH 7 for 3, 15, and 30 days. The 1-d cycling group demonstrated the highest levels of weight loss compared with 3-d cycling and constant immersion. For the ion release, Si4+ and Ca2+ had the highest rates of release in 1-d cycling, whereas the Al3+ release rate with constant pH 2 was highest. The alteration/passivation layer that was formed on the surface of disks possibly prevented further dissolution of pH 10 corroded disks. XPS analysis demonstrated different surface compositions of corroded disks in pH 10 and pH 2. Si4+, K+, Na+, Al3+, and Ca2+ were detected on the surface of corroded pH 10 disks, whereas a Si4+ and P5+-rich surface formed on corroded pH 2 disks. SEM results demonstrated rougher surfaces for corroded disks in cycling conditions and pH 2 constant immersion. In conclusion, increased pH changes significantly promote the corrosion of dental glass-ceramic materials.

9.
J Med Entomol ; 57(1): 17-24, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31586442

RESUMO

Testing behavioral response to insecticidal volatiles requires modifications to the existing designs of olfactometers. To create a testing apparatus in which there is no chemical memory to confound tests, we detail the technical aspects of a new tool with design influences from other olfactometry tools. In addition, this new tool was used to evaluate a novel formulation of metofluthrin for use as an outdoor residual treatment. After sourcing materials to prioritize glass and metal construction, a modular wind tunnel was developed that hybridizes wind tunnel and olfactometer specifications. Volatile contaminants were removed by strong ultraviolet light within the chamber before and between trials. Repellent trials were conducted with an experimental formulation of metofluthrin and a commercial formulation of esfenvalerate, prallethrin, and piperonyl butoxide (Onslaught Fast Cap) against Aedes albopictus (Skuse). Toxicant vapors were delivered with attractants from a lure with behavioral responses scored 20 min post-exposure. Upwind attraction to the attractant lure and the Onslaught Fast Cap plus lure resulted in 90 and 75% capture, respectively. In contrast, metofluthrin vapors resulted in less than 10% attraction, while also causing repellency, disorientation, knockdown, and mortality effects. Our findings demonstrated that an inert modular wind tunnel was functional for mitigating toxic secondary exposures of spatial repellents amidst complex behavioral analysis in mosquitoes. The resulting observations with formulated metofluthrin positively reinforce the merit of transitioning metofluthrin into expanded roles in mosquito management.


Assuntos
Aedes , Quimiotaxia , Ciclopropanos , Fluorbenzenos , Inseticidas , Aedes/fisiologia , Animais , Aprendizagem da Esquiva , Olfatometria
10.
ChemistrySelect ; 4(31): 9185-9189, 2019 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-32149184

RESUMO

The formation and characterization of positively surface charged TiN surfaces were investigated for improving dental implant survival. Surface nitrogen atoms of a traditional TiN implant were converted to a positive charge by a quaternization reaction which greatly increased the antibacterial efficiency. Ti, TiN, and quaternized TiN samples were incubated with human patient subgingival bacteria for 4 hours at 37°C in an anaerobic environment with an approximate 40% reduction in counts on the quaternized surface over traditional Ti and TiN. The samples were challenged with Streptococcus Mutans and fluorescent imaging confirmed significant reduction in the quaternized TiN over the traditional Ti and TiN. Contact angle measurement and X-Ray Photoelectron Spectroscopy (XPS) were utilized to confirm the surface chemistry changes. The XPS results found the charged quaternized nitrogen peak at 399.75 eV that is unique to the quaternized sample.

11.
Artigo em Inglês | MEDLINE | ID: mdl-31035536

RESUMO

Mosquitoes continue to be a major threat to global health, and the ability to reliably monitor, catch, and kill mosquitoes via passive traps is of great importance. Global, low-cost, and easy-to-use outdoor devices are needed to augment existing efforts in mosquito control that combat the spread of disease, such as Zika. Thus, we have developed a modular, portable, non-powered (passive), self-contained, and field-deployable device suitable for releasing volatiles with a wide range of applications such as attracting, repelling, and killing mosquitoes. This unique device relies on a novel nested wick and two-reservoir design that achieves a constant release of volatiles over several hundred hours. Devices loaded with one of either two compounds, geraniol or 1-methylpiperazine (MP), were tested in a controlled environment (32 °C and 70% relative humidity), and both compounds achieved a constant release from our devices at a rate of 2.4 mg/h and 47 mg/h, respectively. The liquid payload can be volatile attractants or repellants as well as mosquitocide-containing feeding solutions for capture and surveillance. This low-cost device can be utilized for both civilian and military mosquito control purposes, but it will be particularly important for protecting those in economically repressed environments, such as sub-Saharan Africa and Central and South America.


Assuntos
Monoterpenos Acíclicos , Repelentes de Insetos , Controle de Mosquitos/instrumentação , Mosquitos Vetores , Piperazinas , Infecção por Zika virus/prevenção & controle , Animais , Culicidae/virologia , Humanos , Zika virus/isolamento & purificação , Infecção por Zika virus/transmissão
12.
J Chromatogr A ; 1573: 156-160, 2018 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-30224281

RESUMO

A rapid thermal desorption-gas chromatography-electron ionization-mass spectrometry (TD-GC-EI-MS) method for airborne transfluthrin detection is studied. Active air sampling of 9 L over 1 h at 23 °C through a Tenax®-loaded tube resulted in efficient capture of airborne transfluthrin. Subsequent thermal desorption was employed to achieve an LOD of 2.6 ppqv (parts per quadrillion by volume). A minimum primary desorption temperature of 300 °C is necessary for optimal recovery of sample from the Tenax® adsorbent. The matrix effects of indoor air lead to an error of 10.9% and 10.5% recovery of sample (10 pg and 100 pg loaded tubes, respectively). The linear range was 74-74,000 ppqv with a correlation coefficient of 0.9981. Active air sampling of a novel passive release device revealed a ∼150 pg/L airborne concentration gradient over 1 m, providing spatial characterization of the device's performance. This efficient method allows for the remote collection of samples and rapid analysis of airborne transfluthrin from industrial applications, optimization studies of commercial products as well as domestic/household monitoring.


Assuntos
Poluentes Atmosféricos/análise , Ciclopropanos/análise , Monitoramento Ambiental/métodos , Fluorbenzenos/análise , Cromatografia Gasosa-Espectrometria de Massas , Monitoramento Ambiental/instrumentação , Polímeros/química
13.
J Pharm Sci ; 96(8): 2154-60, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17506513

RESUMO

The patient-to-patient variability in the dosing of sevelamer HCl for phosphate control led us to test whether the binder's transient exposure to acidic environments (such as the stomach) might alter the compound so as to change its subsequent binding capacity in the more alkaline small intestine. We hypothesized that an acid milieu could either increase the reactive sites (protonated amine groups) or make the polymer more hydrophilic (hydration and swelling allowing more phosphate to reach those sites). Eight hundred milligrams of Renagel tablets were exposed to pHs 1, 2.3, and 7 (n = 7 each acidity level) for 1 h. NaCl was added to keep ionic strength the same. Measured by atomic emission phosphate uptake after 3 h at pH 7 was, respectively, 3.13 +/- 0.21, 2.72 +/- 0.35, and 1.85 +/- 0.46 mequiv./g (p = 0.0006, pH 1 vs. pH 7). Semi-automated computerized image analysis was then performed to measure swelling of the particles. We constructed a glass continuous-flow cell that allowed stationary particles and real-time photography. Using digitized optical measurements there was no difference (p > 0.8) between the swelling after 1 h of pH 1 or 7 solutions (60.2 +/- 14.8% vs. 59.5 +/- 9.8% increase in diameter). Our findings support the importance of transient acid exposure in enhancing phosphate binding, due to increased protonated sites rather than by more swelling. Patients with acquired or pharmacologic achlorhydria would not benefit from this unexpected in vivo reaction. Possibly manufacturing sevelamer with a higher degree of protonation or administering it with appropriately acidic vehicles or beverages remains to be investigated.


Assuntos
Quelantes/metabolismo , Ácido Clorídrico/química , Fosfatos/metabolismo , Poliaminas/metabolismo , Adsorção , Ácido Gástrico/metabolismo , Humanos , Hidrogéis , Concentração de Íons de Hidrogênio , Concentração Osmolar , Sevelamer , Cloreto de Sódio/farmacologia , Fatores de Tempo
15.
Am J Vet Res ; 67(8): 1453-8, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16881861

RESUMO

OBJECTIVE: To evaluate manufacturing variability, diffusion of filling solutions, and maintenance of occlusion over time in 3 sizes of silicone hydraulic occluders (HOs). SAMPLE POPULATION: 2-, 5-, and 20-mm HOs (HO2, HO5, and HO20, respectively). PROCEDURES: Manufacturing variability was analyzed by comparing variation in internal luminal areas and filling volumes within each size group. Occluders were filled to 100% occlusion with air (n = 4), saline (0.9% NaCl) solution (4), or sodium hyaluronate (4) and submerged in simulated body fluid. Changes in luminal area and weight were recorded for 133 days to evaluate maintenance of occlusion. RESULTS: Considerable variability in uninflated luminal area and fill volumes was observed among the 3 sizes of HOs. Loss of occlusion developed in the first 12 hours in all air-filled HOs. Fluid-filled occluders were reliable in maintenance of occlusion after 133 days (99.99% for HO20, 99.59% for HO5, and 90.40% for HO2), although diffusion of saline solution and hyaluronate from all HOs was confirmed by detection of significant decreases in weight over time. There was no significant difference in weight loss between HOs filled with saline solution and HOs filled with sodium hyaluronate. CONCLUSIONS AND CLINICAL RELEVANCE: Saline solution or sodium hyaluronate may be used as a filling solution in the HOs tested. Maintenance of occlusion was best in the larger sizes. Saline solution or sodium hyaluronate should be used in future clinical investigations of HOs. Retrograde filling to remove air should be used when filling HOs with fluid.


Assuntos
Próteses e Implantes/veterinária , Silicones , Soluções , Animais , Difusão , Próteses e Implantes/normas , Fatores de Tempo
16.
Am J Vet Res ; 77(6): 653-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27227505

RESUMO

OBJECTIVE To evaluate the closure rate and completeness of closure for a silicone-polyacrylic acid gradual venous occlusion device placed around an intra-abdominal vein to simulate gradual occlusion of an extrahepatic portosystemic shunt. ANIMALS 3 purpose-bred cats and 2 purpose-bred dogs. PROCEDURES The device was surgically placed around an external (cats) or internal (dogs) iliac vein. Computed tomographic angiography was performed at the time of surgery and 2, 4, and 6 weeks after surgery. Ultrasonographic examinations of blood flow through the vein within the device were performed at the time of surgery and at weekly intervals thereafter. Dogs were euthanized 6 weeks after surgery, and the external iliac veins were harvested for histologic examination. RESULTS The prototype gradual venous occlusion device was successfully placed in all animals, and all animals recovered without complications following the placement procedure. The vessel was completely occluded in 2 cats by 6 weeks after surgery, as determined on the basis of results of CT and ultrasonography; there was incomplete occlusion with a luminal diameter of 1.5 mm in the other cat by 6 weeks after surgery. The vessel was completely occluded in both dogs by 6 weeks after surgery. Histologic examination of the external iliac veins obtained from the dogs revealed minimal inflammation of the vessel wall and no thrombus formation. CONCLUSIONS AND CLINICAL RELEVANCE The prototype device induced gradual attenuation of an intra-abdominal vessel over a 6-week period. This device may provide another option for gradual occlusion of extrahepatic portosystemic shunts.


Assuntos
Resinas Acrílicas , Gatos , Cães , Silicones , Procedimentos Cirúrgicos Vasculares/instrumentação , Animais , Materiais Biocompatíveis , Doenças do Gato/prevenção & controle , Doenças do Cão/prevenção & controle , Desenho de Equipamento , Hemodinâmica , Veia Cava Inferior
17.
Int J Cardiol ; 220: 149-54, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27379917

RESUMO

BACKGROUND: A new post-myocardial infarction (MI) therapy is injection of high-water-content polymeric biomaterial gels (hydrogels) into damaged myocardium to modulate cardiac negative remodeling and preserve heart function. METHODS: We investigated the therapeutic potential of a novel gelatinized alginate hydrogel with a unique microstructure of uniform capillary-like channels (termed Capgel). Shortly (48h) after induced anterior MI, Sprague Dawley rats received intramyocardial injection of Capgel directly into the antero-septal wall at the infarct border zone (n=12) or no injection (n=10, controls). Echocardiograms were performed at 48h (week 0) and 4weeks (week 4) to evaluate left ventricular function. RESULTS: Echocardiograms showed 27% improvement of left ventricular systolic function over time with gel injection: fractional shortening increased from 26±3% at week 0 to 33±2% at week 4 (p=0.001). Capgel was present at the injection site after 4weeks, but was minimal at 8weeks. The remaining gel was heavily populated by CD68(+) macrophages with CD206(+) clusters and blood vessels. An in vitro experiment was performed to assess Angiotensin-(1-7) released from Capgel. Angiotensin-(1-7) was released from the Capgel in a sustained manner for 90days. CONCLUSIONS: Use of Capgel, a degradable, bioactive hydrogel composed of gelatinized capillary-alginate gel, appears safe for intramyocardial injection, is associated with improved left ventricular function after MI in rats, and may provide a long-term supply of Angiotensin-(1-7).


Assuntos
Alginatos , Angiotensina I , Infarto do Miocárdio , Fragmentos de Peptídeos , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/efeitos dos fármacos , Alginatos/química , Alginatos/farmacologia , Angiotensina I/química , Angiotensina I/farmacologia , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Modelos Animais de Doenças , Ecocardiografia/métodos , Gelatina/farmacologia , Ácido Glucurônico/química , Ácido Glucurônico/farmacologia , Ácidos Hexurônicos/química , Ácidos Hexurônicos/farmacologia , Hidrogéis/farmacologia , Injeções Intralesionais/métodos , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/farmacologia , Ratos , Ratos Sprague-Dawley , Resultado do Tratamento
18.
J Nanosci Nanotechnol ; 5(6): 899-904, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16060150

RESUMO

We describe a novel technique of using fluorescent silica nanoparticles (FSNPs) to detect over-expressed folate receptors, as typical for certain malignancies (metastatic adenocarcinoma, pituitary adenoma and others). Using Stöber's method with some modification, 135 nm size FSNPs were synthesized by a hydrolysis and co-condensation reaction of tetraethylorthosilicate (TEOS), fluorescein labeled (3-aminopropyl)triethoxysilane (APTS) and a water-dispersible silane reagent, (3-trihydroxysilyl)propyl methylphosphonate (THPMP) in the presence of ammonium hydroxide catalyst. Folic acid (folate) was covalently attached to the amine modified FSNPs by a carbodiimide coupling reaction. The characterization of folate-FSNPs was performed using a variety of spectroscopic (UV-VIS and fluorescence), microscopic (transmission electron microscopy, TEM) and light scattering techniques. Folate conjugated FSNPs were then targeted to human squamous cancer cells (SCC-9). Laser scanning confocal images successfully demonstrated the labeling of SCC-9 cells and the efficacy of FSNP based detection system.


Assuntos
Biomarcadores Tumorais/metabolismo , Proteínas de Transporte/metabolismo , Fibroblastos/metabolismo , Fluoresceína-5-Isotiocianato , Ácido Fólico/química , Ácido Fólico/farmacocinética , Microscopia de Fluorescência/métodos , Neoplasias/metabolismo , Receptores de Superfície Celular/metabolismo , Linhagem Celular , Materiais Revestidos Biocompatíveis/química , Fibroblastos/citologia , Fluoresceína-5-Isotiocianato/química , Fluoresceína-5-Isotiocianato/farmacocinética , Corantes Fluorescentes , Receptores de Folato com Âncoras de GPI , Humanos , Teste de Materiais , Nanotubos/química , Nanotubos/ultraestrutura , Neoplasias/patologia , Tamanho da Partícula , Dióxido de Silício/química , Coloração e Rotulagem/métodos
19.
Organogenesis ; 11(2): 47-57, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26252820

RESUMO

Advances in organ regeneration have been facilitated by gentle decellularization protocols that maintain distinct tissue compartments, and thereby allow seeding of blood vessels with endothelial lineages separate from populations of the parenchyma with tissue-specific cells. We hypothesized that a reconstituted vasculature could serve as a novel platform for perfusing cells derived from a different organ: thus discordance of origin between the vascular and functional cells, leading to a hybrid repurposed organ. The need for a highly vascular bed is highlighted by tissue engineering approaches that involve transplantation of just cells, as attempted for insulin production to treat human diabetes. Those pancreatic islet cells present unique challenges since large numbers are needed to allow the cell-to-cell signaling required for viability and proper function; however, increasing their number is limited by inadequate perfusion and hypoxia. As proof of principle of the repurposed organ methodology we harnessed the vasculature of a kidney scaffold while seeding the collecting system with insulin-producing cells. Pig kidneys were decellularized by sequential detergent, enzymatic and rinsing steps. Maintenance of distinct vascular and collecting system compartments was demonstrated by both fluorescent 10 micron polystyrene microspheres and cell distributions in tissue sections. Sterilized acellular scaffolds underwent seeding separately via the artery (fibroblasts or endothelioma cells) and retrograde (murine ßTC-tet cells) up the ureter. After three-day bioreactor incubation, histology confirmed separation of cells in the vasculature from those in the collecting system. ßTC-tet clusters survived in tubules, glomerular Bowman's space, demonstrated insulin immunolabeling, and thereby supported the feasibility of kidney-to-pancreas repurposing.


Assuntos
Bioprótese , Rim/crescimento & desenvolvimento , Rins Artificiais , Pâncreas Artificial , Engenharia Tecidual/instrumentação , Alicerces Teciduais , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Reutilização de Equipamento , Rim/citologia , Camundongos , Suínos
20.
J Biomed Mater Res B Appl Biomater ; 70(2): 384-8, 2004 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-15264323

RESUMO

A novel oligomer was synthesized in different molecular masses and used as a primer in dentin bonding. The hypothesis was that an intermediate molecular mass would optimize the conflicting needs for diffusion into etched dentin (low M(w)) and high mechanical properties (high M(w)). The initial oligomer synthesized was tert butylmethacrylate-co-maleic anhydride, which was further reacted to add hyrdoxyethyl methacrylate (HEMA) across the anhydride. The oligomer was synthesized in a series of molecular masses from approximately 800-6000 amu. The oligomer with an average M(w) of approximately 1000 amu provided the highest bond strength (16 MPa), with both lower and higher molar mass oligomers producing lower bond strengths. A polynomial model was fitted to the data with an R(2) = 0.606, while a linear model only had an R(2) = 0.534. This implies that the graph of molar mass to bond strength has a maximum in the range of molar masses examined, and that an optimum molar mass can be found between 800 and 6000 amu.


Assuntos
Dentina/química , Anidridos Maleicos/química , Metacrilatos/química , Anidridos Maleicos/síntese química , Metacrilatos/síntese química , Peso Molecular , Resistência ao Cisalhamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA